Viridian intersects 15m of 1.1% CuEq in 1.5km Step Out
Original announcement by cse on
- Company
- Viridian Metals Inc.
- Ticker
- VRDN
- Exchange
- CSE
- Region
- Labrador
- Primary commodity
- Copper
- Secondary commodities
- Nickel, Cobalt
- Document categories
- Drill results
- Extracted
- 2026-10-23 13:07:51 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Viridian Metals announced initial assay results from its southern step-out drilling program at the Kraken Main copper-nickel-cobalt project in Labrador, intersecting 40.8 metres at 0.63% CuEq, including 15.7 metres at 1.09% CuEq, in a 1.5 km step-out. These results confirm greater mineralized thicknesses and higher-grade zones than initially targeted, with mineralization remaining open along strike and down dip. The company anticipates further assay results from additional step-out holes and plans an updated Exploration Target in January 2027.
Reasoning: Viridian Metals reported strong drill results from a 1.5 km step-out at its Kraken Main project, intersecting significant widths (up to 40.8m) and high grades (up to 1.30% CuEq). These results substantially exceed previous exploration target thicknesses and indicate a larger, thicker, and higher-grade mineralized system with open-pit potential, significantly extending the known mineralization.
Positive factors
- Significant step-out extension (1.5 km) confirming mineralization continuity
- Intersected greater mineralized thicknesses (up to 40.8m) than initial exploration target (8.6m average)
- Identified higher-grade zones (up to 1.30% CuEq) within broader mineralization
- Near-surface mineralization with potential for open-pit development
- Mineralization remains open along strike and down dip, indicating significant expansion potential
- Comprehensive QA/QC disclosure and transparent compositing parameters
Negative factors
- True thickness of reported intervals is not yet known, potentially overstating actual width
- Metal equivalent calculations rely on assumptions for prices and recoveries which may differ from actuals
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 24

Extracted facts
Stored fact records: 24. Some facts used in scoring do not have a stored record.
Drill Results (24)
VKS25-024Kraken Main · copperGrade: 0.68Grade Unit: %Intercept: 50.15 mView all detailsHide details
Identity
- Hole ID
- VKS25-024
- Project
- Kraken Main
- Commodity
- copper
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.68
- Grade Unit
- %
- Intercept
- 50.15 m
- From
- 1 m
- To
- 51.15 m
- Hole Depth
- 51.15 m
- Intercept Depth
- 1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS25-024:1-51.15
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446090
- Northing
- 6020686
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 112 °
- Dip
- 72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.68
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported broad intercept with a good copper equivalent grade, providing context for the new results.
Positive factors
- Broad intercept width
- Good CuEq grade
Negative factors
- True width not known
- Historical result in this release
Evidence · table
“0.68”
Context: 50.15
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS25-024Kraken Main · copperGrade: 0.19Grade Unit: %Intercept: 50.15 mView all detailsHide details
Identity
- Hole ID
- VKS25-024
- Project
- Kraken Main
- Commodity
- copper
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.19
- Grade Unit
- %
- Intercept
- 50.15 m
- From
- 1 m
- To
- 51.15 m
- Hole Depth
- 51.15 m
- Intercept Depth
- 1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS25-024:1-51.15
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446090
- Northing
- 6020686
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 112 °
- Dip
- 72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported broad intercept with a moderate copper grade, contributing to the overall CuEq.
Positive factors
- Broad intercept width
Negative factors
- True width not known
- Historical result in this release
Evidence · table
“0.19”
Context: 50.15
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS25-024Kraken Main · nickelGrade: 0.26Grade Unit: %Intercept: 50.15 mView all detailsHide details
Identity
- Hole ID
- VKS25-024
- Project
- Kraken Main
- Commodity
- nickel
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.26
- Grade Unit
- %
- Intercept
- 50.15 m
- From
- 1 m
- To
- 51.15 m
- Hole Depth
- 51.15 m
- Intercept Depth
- 1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS25-024:1-51.15
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446090
- Northing
- 6020686
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 112 °
- Dip
- 72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported broad intercept with a moderate nickel grade, contributing to the overall CuEq.
Positive factors
- Broad intercept width
Negative factors
- True width not known
- Historical result in this release
Evidence · table
“0.26”
Context: 50.15
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS25-024Kraken Main · cobaltGrade: 0.04Grade Unit: %Intercept: 50.15 mView all detailsHide details
Identity
- Hole ID
- VKS25-024
- Project
- Kraken Main
- Commodity
- cobalt
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 50.15 m
- From
- 1 m
- To
- 51.15 m
- Hole Depth
- 51.15 m
- Intercept Depth
- 1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS25-024:1-51.15
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446090
- Northing
- 6020686
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 112 °
- Dip
- 72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported broad intercept with a moderate cobalt grade, contributing to the overall CuEq.
Positive factors
- Broad intercept width
Negative factors
- True width not known
- Historical result in this release
Evidence · table
“0.04”
Context: 50.15
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS25-024Kraken Main · copperGrade: 1.12Grade Unit: %Intercept: 18.8 mView all detailsHide details
Identity
- Hole ID
- VKS25-024
- Project
- Kraken Main
- Commodity
- copper
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 1.12
- Grade Unit
- %
- Intercept
- 18.8 m
- From
- 12.2 m
- To
- 31 m
- Hole Depth
- 51.15 m
- Intercept Depth
- 12.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS25-024:12.2-31
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446090
- Northing
- 6020686
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 112 °
- Dip
- 72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.12
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported high-grade sub-interval, demonstrating the potential for higher-grade zones within the broader mineralization.
Positive factors
- High CuEq grade
- Good intercept width
Negative factors
- True width not known
- Historical result in this release
Evidence · table
“1.12”
Context: 18.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS25-024Kraken Main · copperGrade: 0.33Grade Unit: %Intercept: 18.8 mView all detailsHide details
Identity
- Hole ID
- VKS25-024
- Project
- Kraken Main
- Commodity
- copper
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.33
- Grade Unit
- %
- Intercept
- 18.8 m
- From
- 12.2 m
- To
- 31 m
- Hole Depth
- 51.15 m
- Intercept Depth
- 12.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS25-024:12.2-31
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446090
- Northing
- 6020686
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 112 °
- Dip
- 72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported sub-interval with a good copper grade, contributing to the higher CuEq.
Positive factors
- Good intercept width
Negative factors
- True width not known
- Historical result in this release
Evidence · table
“0.33”
Context: 18.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS25-024Kraken Main · nickelGrade: 0.43Grade Unit: %Intercept: 18.8 mView all detailsHide details
Identity
- Hole ID
- VKS25-024
- Project
- Kraken Main
- Commodity
- nickel
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.43
- Grade Unit
- %
- Intercept
- 18.8 m
- From
- 12.2 m
- To
- 31 m
- Hole Depth
- 51.15 m
- Intercept Depth
- 12.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS25-024:12.2-31
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446090
- Northing
- 6020686
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 112 °
- Dip
- 72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported sub-interval with a good nickel grade, contributing to the higher CuEq.
Positive factors
- Good intercept width
Negative factors
- True width not known
- Historical result in this release
Evidence · table
“0.43”
Context: 18.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS25-024Kraken Main · cobaltGrade: 0.06Grade Unit: %Intercept: 18.8 mView all detailsHide details
Identity
- Hole ID
- VKS25-024
- Project
- Kraken Main
- Commodity
- cobalt
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 18.8 m
- From
- 12.2 m
- To
- 31 m
- Hole Depth
- 51.15 m
- Intercept Depth
- 12.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS25-024:12.2-31
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446090
- Northing
- 6020686
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 112 °
- Dip
- 72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported sub-interval with a good cobalt grade, contributing to the higher CuEq.
Positive factors
- Good intercept width
Negative factors
- True width not known
- Historical result in this release
Evidence · table
“0.06”
Context: 18.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS25-024Kraken Main · copperGrade: 1.28Grade Unit: %Intercept: 11.6 mView all detailsHide details
Identity
- Hole ID
- VKS25-024
- Project
- Kraken Main
- Commodity
- copper
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 1.28
- Grade Unit
- %
- Intercept
- 11.6 m
- From
- 19.4 m
- To
- 31 m
- Hole Depth
- 51.15 m
- Intercept Depth
- 19.4 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS25-024:19.4-31
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446090
- Northing
- 6020686
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 112 °
- Dip
- 72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.28
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported very high-grade sub-interval, highlighting the potential for bonanza grades within the system.
Positive factors
- Very high CuEq grade
- Good intercept width
Negative factors
- True width not known
- Historical result in this release
Evidence · table
“1.28”
Context: 11.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS25-024Kraken Main · copperGrade: 0.3Grade Unit: %Intercept: 11.6 mView all detailsHide details
Identity
- Hole ID
- VKS25-024
- Project
- Kraken Main
- Commodity
- copper
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 11.6 m
- From
- 19.4 m
- To
- 31 m
- Hole Depth
- 51.15 m
- Intercept Depth
- 19.4 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS25-024:19.4-31
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446090
- Northing
- 6020686
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 112 °
- Dip
- 72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported sub-interval with a good copper grade, contributing to the very high CuEq.
Positive factors
- Good intercept width
Negative factors
- True width not known
- Historical result in this release
Evidence · table
“0.3”
Context: 11.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS25-024Kraken Main · nickelGrade: 0.5Grade Unit: %Intercept: 11.6 mView all detailsHide details
Identity
- Hole ID
- VKS25-024
- Project
- Kraken Main
- Commodity
- nickel
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.5
- Grade Unit
- %
- Intercept
- 11.6 m
- From
- 19.4 m
- To
- 31 m
- Hole Depth
- 51.15 m
- Intercept Depth
- 19.4 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS25-024:19.4-31
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446090
- Northing
- 6020686
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 112 °
- Dip
- 72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported sub-interval with a good nickel grade, contributing to the very high CuEq.
Positive factors
- Good intercept width
Negative factors
- True width not known
- Historical result in this release
Evidence · table
“0.5”
Context: 11.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS25-024Kraken Main · cobaltGrade: 0.07Grade Unit: %Intercept: 11.6 mView all detailsHide details
Identity
- Hole ID
- VKS25-024
- Project
- Kraken Main
- Commodity
- cobalt
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 11.6 m
- From
- 19.4 m
- To
- 31 m
- Hole Depth
- 51.15 m
- Intercept Depth
- 19.4 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS25-024:19.4-31
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446090
- Northing
- 6020686
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 112 °
- Dip
- 72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported sub-interval with a good cobalt grade, contributing to the very high CuEq.
Positive factors
- Good intercept width
Negative factors
- True width not known
- Historical result in this release
Evidence · table
“0.07”
Context: 11.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS26-052Kraken Main · copperGrade: 0.46Grade Unit: %Intercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- VKS26-052
- Project
- Kraken Main
- Commodity
- copper
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.46
- Grade Unit
- %
- Intercept
- 2.3 m
- From
- 0.7 m
- To
- 3 m
- Hole Depth
- 30.65 m
- Intercept Depth
- 0.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS26-052:0.7-3
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446028
- Northing
- 6020269
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 90 °
- Dip
- 73 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.46
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported narrow, near-surface intercept with a moderate CuEq grade.
Positive factors
- Near-surface intercept
Negative factors
- Narrow width
- True width not known
- Historical result in this release
Evidence · table
“0.46”
Context: 2.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS26-052Kraken Main · copperGrade: 0.07Grade Unit: %Intercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- VKS26-052
- Project
- Kraken Main
- Commodity
- copper
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 2.3 m
- From
- 0.7 m
- To
- 3 m
- Hole Depth
- 30.65 m
- Intercept Depth
- 0.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS26-052:0.7-3
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446028
- Northing
- 6020269
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 90 °
- Dip
- 73 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported narrow, near-surface intercept with a low copper grade.
Positive factors
- Near-surface intercept
Negative factors
- Narrow width
- True width not known
- Historical result in this release
Evidence · table
“0.07”
Context: 2.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS26-052Kraken Main · nickelGrade: 0.13Grade Unit: %Intercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- VKS26-052
- Project
- Kraken Main
- Commodity
- nickel
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.13
- Grade Unit
- %
- Intercept
- 2.3 m
- From
- 0.7 m
- To
- 3 m
- Hole Depth
- 30.65 m
- Intercept Depth
- 0.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS26-052:0.7-3
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446028
- Northing
- 6020269
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 90 °
- Dip
- 73 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported narrow, near-surface intercept with a low nickel grade.
Positive factors
- Near-surface intercept
Negative factors
- Narrow width
- True width not known
- Historical result in this release
Evidence · table
“0.13”
Context: 2.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS26-052Kraken Main · cobaltGrade: 0.03Grade Unit: %Intercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- VKS26-052
- Project
- Kraken Main
- Commodity
- cobalt
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 2.3 m
- From
- 0.7 m
- To
- 3 m
- Hole Depth
- 30.65 m
- Intercept Depth
- 0.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS26-052:0.7-3
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446028
- Northing
- 6020269
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 90 °
- Dip
- 73 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported narrow, near-surface intercept with a low cobalt grade.
Positive factors
- Near-surface intercept
Negative factors
- Narrow width
- True width not known
- Historical result in this release
Evidence · table
“0.03”
Context: 2.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS26-052Kraken Main · copperGrade: 0.18Grade Unit: %Intercept: 7.5 mView all detailsHide details
Identity
- Hole ID
- VKS26-052
- Project
- Kraken Main
- Commodity
- copper
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.18
- Grade Unit
- %
- Intercept
- 7.5 m
- From
- 7.5 m
- To
- 15 m
- Hole Depth
- 30.65 m
- Intercept Depth
- 7.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS26-052:7.5-15
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446028
- Northing
- 6020269
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 90 °
- Dip
- 73 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.18
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported narrow intercept with a low CuEq grade.
Negative factors
- Low grade
- True width not known
- Historical result in this release
Evidence · table
“0.18”
Context: 7.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS26-052Kraken Main · copperGrade: 0.06Grade Unit: %Intercept: 7.5 mView all detailsHide details
Identity
- Hole ID
- VKS26-052
- Project
- Kraken Main
- Commodity
- copper
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 7.5 m
- From
- 7.5 m
- To
- 15 m
- Hole Depth
- 30.65 m
- Intercept Depth
- 7.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS26-052:7.5-15
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446028
- Northing
- 6020269
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 90 °
- Dip
- 73 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported narrow intercept with a very low copper grade.
Negative factors
- Very low grade
- True width not known
- Historical result in this release
Evidence · table
“0.06”
Context: 7.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS26-052Kraken Main · nickelGrade: 0.06Grade Unit: %Intercept: 7.5 mView all detailsHide details
Identity
- Hole ID
- VKS26-052
- Project
- Kraken Main
- Commodity
- nickel
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 7.5 m
- From
- 7.5 m
- To
- 15 m
- Hole Depth
- 30.65 m
- Intercept Depth
- 7.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS26-052:7.5-15
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446028
- Northing
- 6020269
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 90 °
- Dip
- 73 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported narrow intercept with a very low nickel grade.
Negative factors
- Very low grade
- True width not known
- Historical result in this release
Evidence · table
“0.06”
Context: 7.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS26-052Kraken Main · cobaltGrade: 0.01Grade Unit: %Intercept: 7.5 mView all detailsHide details
Identity
- Hole ID
- VKS26-052
- Project
- Kraken Main
- Commodity
- cobalt
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 7.5 m
- From
- 7.5 m
- To
- 15 m
- Hole Depth
- 30.65 m
- Intercept Depth
- 7.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS26-052:7.5-15
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446028
- Northing
- 6020269
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 90 °
- Dip
- 73 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported narrow intercept with a very low cobalt grade.
Negative factors
- Very low grade
- True width not known
- Historical result in this release
Evidence · table
“0.01”
Context: 7.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS26-052Kraken Main · copperGrade: 0.25Grade Unit: %Intercept: 1.7 mView all detailsHide details
Identity
- Hole ID
- VKS26-052
- Project
- Kraken Main
- Commodity
- copper
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.25
- Grade Unit
- %
- Intercept
- 1.7 m
- From
- 23 m
- To
- 24.7 m
- Hole Depth
- 30.65 m
- Intercept Depth
- 23 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS26-052:23-24.7
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446028
- Northing
- 6020269
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 90 °
- Dip
- 73 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.25
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported very narrow intercept with a low CuEq grade.
Negative factors
- Narrow width
- Low grade
- True width not known
- Historical result in this release
Evidence · table
“0.25”
Context: 1.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS26-052Kraken Main · copperGrade: 0.09Grade Unit: %Intercept: 1.7 mView all detailsHide details
Identity
- Hole ID
- VKS26-052
- Project
- Kraken Main
- Commodity
- copper
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.09
- Grade Unit
- %
- Intercept
- 1.7 m
- From
- 23 m
- To
- 24.7 m
- Hole Depth
- 30.65 m
- Intercept Depth
- 23 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS26-052:23-24.7
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446028
- Northing
- 6020269
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 90 °
- Dip
- 73 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported very narrow intercept with a very low copper grade.
Negative factors
- Very low grade
- True width not known
- Historical result in this release
Evidence · table
“0.09”
Context: 1.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS26-052Kraken Main · nickelGrade: 0.07Grade Unit: %Intercept: 1.7 mView all detailsHide details
Identity
- Hole ID
- VKS26-052
- Project
- Kraken Main
- Commodity
- nickel
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 1.7 m
- From
- 23 m
- To
- 24.7 m
- Hole Depth
- 30.65 m
- Intercept Depth
- 23 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS26-052:23-24.7
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446028
- Northing
- 6020269
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 90 °
- Dip
- 73 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported very narrow intercept with a very low nickel grade.
Negative factors
- Very low grade
- True width not known
- Historical result in this release
Evidence · table
“0.07”
Context: 1.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
VKS26-052Kraken Main · cobaltGrade: 0.02Grade Unit: %Intercept: 1.7 mView all detailsHide details
Identity
- Hole ID
- VKS26-052
- Project
- Kraken Main
- Commodity
- cobalt
- Region
- labrador
- Reported Region
- labrador
- Ticker
- VRDN
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 1.7 m
- From
- 23 m
- To
- 24.7 m
- Hole Depth
- 30.65 m
- Intercept Depth
- 23 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- VKS26-052:23-24.7
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 446028
- Northing
- 6020269
- CRS
- NAD83 / UTM Zone 20N
- Azimuth
- 90 °
- Dip
- 73 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % CuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 1.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-23T00:00:00.000Z
Reasoning: This is a previously reported very narrow intercept with a very low cobalt grade.
Negative factors
- Very low grade
- True width not known
- Historical result in this release
Evidence · table
“0.02”
Context: 1.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "Forward-looking information in this news release includes, but is not limited to, statements regarding: (i) the continua"
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.