Union Power Metals Confirms Historical Manganese Mineralization in First Modern Drill Holes at Michalová, Slovakia
Original announcement by orestocks on
- Company
- Union Power Metals Corporation
- Ticker
- UPPR.CN
- Exchange
- Unavailable
- Region
- Slovakia
- Primary commodity
- Unavailable
- Secondary commodities
- None reported
- Document categories
- Other, Drill results
- Extracted
- 2026-11-17 12:36:01 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Union Power Metals announced that its first modern drill holes at the Michalová manganese project in Slovakia visually confirmed historical manganese mineralization. Twin holes V-13 and V-11 intersected near-surface manganese oxide mineralization at depths and thicknesses consistent with 1950s drilling records, providing initial confidence in the historical dataset. While core recovery was 100% through mineralized intervals, laboratory assay results for the new holes are pending, which will provide grade information and further validate the historical data.
Reasoning: Union Power Metals reported visual confirmation of manganese mineralization in its first modern drill holes, corroborating historical records, which is a positive step for data validation, but the lack of assay results for the new holes limits immediate economic assessment.
Positive factors
- Visual confirmation of manganese mineralization in new drill holes
- Mineralization intersected at depths and thicknesses consistent with historical records
- 100% core recovery through mineralized intervals
- First step in validating a large historical drill hole dataset
Negative factors
- Assay results for modern drill holes are pending, so no grade information is available
- Visual estimates are not a substitute for laboratory assays
- Historical data is unverified and not compliant with modern reporting standards (NI 43-101)
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 13

Classification and evidence
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: Historical sampling results from 1952-1955 are transcribed and presented for context, not as new assays or reinterpretation.
Evidence · text
“Table 2 – Historical sampling results, holes M-96 and M-114 (Czechoslovak state exploration, 1952–1955)”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: The historical data's sample preparation, analytical methods, and quality-control procedures are not fully documented, and for the new holes, QA/QC details will be provided with future assay results.
Evidence · text
“the sample preparation, analytical methods and quality-control procedures are not fully documented.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: The reported intervals for the new holes are drilled thicknesses, and true thickness is not yet known.
Evidence · text
“Intervals are drilled thicknesses in vertical holes; true thickness is not yet known.”
Extracted facts
Stored fact records: 13. Some facts used in scoring do not have a stored record.
Drill Results (13)
M-96Michalová · manganeseGrade: 1.63Grade Unit: %Intercept: 0.5 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- M-96
- Project
- Michalová
- Commodity
- manganese
- Region
- slovakia
- Reported Region
- slovakia
- Ticker
- UPPR.CN
Geometry
- Grade
- 1.63
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 3.15 m
- To
- 3.65 m
- Hole Depth
- 25.9 m
- Intercept Depth
- 3.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- M-96:3.15-3.65
QA/QC
- Laboratory
- state laboratories of the period
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- low_confidence
- Historical
- Yes
Dates
- Event date
- 2026-11-17T00:00:00.000Z
Reasoning: Historical manganese intercept from 1950s drilling, presented for context and not verified by modern standards, with low grade.
Negative factors
- Historical data, not verified by modern standards
- Low grade for manganese
- No QA/QC documentation
Evidence · table
“1.63”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
M-96Michalová · manganeseGrade: 1.21Grade Unit: %Intercept: 0.35 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- M-96
- Project
- Michalová
- Commodity
- manganese
- Region
- slovakia
- Reported Region
- slovakia
- Ticker
- UPPR.CN
Geometry
- Grade
- 1.21
- Grade Unit
- %
- Intercept
- 0.35 m
- From
- 3.65 m
- To
- 4 m
- Hole Depth
- 25.9 m
- Intercept Depth
- 3.65 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- M-96:3.65-4
QA/QC
- Laboratory
- state laboratories of the period
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- low_confidence
- Historical
- Yes
Dates
- Event date
- 2026-11-17T00:00:00.000Z
Reasoning: Historical manganese intercept from 1950s drilling, presented for context and not verified by modern standards, with low grade.
Negative factors
- Historical data, not verified by modern standards
- Low grade for manganese
- No QA/QC documentation
Evidence · table
“1.21”
Context: 0.35
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
M-96Michalová · manganeseGrade: 9.49Grade Unit: %Intercept: 0.5 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- M-96
- Project
- Michalová
- Commodity
- manganese
- Region
- slovakia
- Reported Region
- slovakia
- Ticker
- UPPR.CN
Geometry
- Grade
- 9.49
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 10.5 m
- To
- 11 m
- Hole Depth
- 25.9 m
- Intercept Depth
- 10.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- M-96:10.5-11
QA/QC
- Laboratory
- state laboratories of the period
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- low_confidence
- Historical
- Yes
Dates
- Event date
- 2026-11-17T00:00:00.000Z
Reasoning: Historical manganese intercept from 1950s drilling, presented for context and not verified by modern standards.
Negative factors
- Historical data, not verified by modern standards
- No QA/QC documentation
Evidence · table
“9.49”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
M-96Michalová · manganeseGrade: 11.99Grade Unit: %Intercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- M-96
- Project
- Michalová
- Commodity
- manganese
- Region
- slovakia
- Reported Region
- slovakia
- Ticker
- UPPR.CN
Geometry
- Grade
- 11.99
- Grade Unit
- %
- Intercept
- 1 m
- From
- 11 m
- To
- 12 m
- Hole Depth
- 25.9 m
- Intercept Depth
- 11 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- M-96:11-12
QA/QC
- Laboratory
- state laboratories of the period
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- low_confidence
- Historical
- Yes
Dates
- Event date
- 2026-11-17T00:00:00.000Z
Reasoning: Historical manganese intercept from 1950s drilling, presented for context and not verified by modern standards.
Negative factors
- Historical data, not verified by modern standards
- No QA/QC documentation
Evidence · table
“11.99”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
M-96Michalová · manganeseGrade: 12.69Grade Unit: %Intercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- M-96
- Project
- Michalová
- Commodity
- manganese
- Region
- slovakia
- Reported Region
- slovakia
- Ticker
- UPPR.CN
Geometry
- Grade
- 12.69
- Grade Unit
- %
- Intercept
- 1 m
- From
- 12 m
- To
- 13 m
- Hole Depth
- 25.9 m
- Intercept Depth
- 12 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- M-96:12-13
QA/QC
- Laboratory
- state laboratories of the period
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- low_confidence
- Historical
- Yes
Dates
- Event date
- 2026-11-17T00:00:00.000Z
Reasoning: Historical manganese intercept from 1950s drilling, presented for context and not verified by modern standards.
Negative factors
- Historical data, not verified by modern standards
- No QA/QC documentation
Evidence · table
“12.69”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
M-96Michalová · manganeseGrade: 7.83Grade Unit: %Intercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- M-96
- Project
- Michalová
- Commodity
- manganese
- Region
- slovakia
- Reported Region
- slovakia
- Ticker
- UPPR.CN
Geometry
- Grade
- 7.83
- Grade Unit
- %
- Intercept
- 1 m
- From
- 13 m
- To
- 14 m
- Hole Depth
- 25.9 m
- Intercept Depth
- 13 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- M-96:13-14
QA/QC
- Laboratory
- state laboratories of the period
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- low_confidence
- Historical
- Yes
Dates
- Event date
- 2026-11-17T00:00:00.000Z
Reasoning: Historical manganese intercept from 1950s drilling, presented for context and not verified by modern standards.
Negative factors
- Historical data, not verified by modern standards
- No QA/QC documentation
Evidence · table
“7.83”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
M-96Michalová · manganeseGrade: 3.31Grade Unit: %Intercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- M-96
- Project
- Michalová
- Commodity
- manganese
- Region
- slovakia
- Reported Region
- slovakia
- Ticker
- UPPR.CN
Geometry
- Grade
- 3.31
- Grade Unit
- %
- Intercept
- 1 m
- From
- 14 m
- To
- 15 m
- Hole Depth
- 25.9 m
- Intercept Depth
- 14 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- M-96:14-15
QA/QC
- Laboratory
- state laboratories of the period
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- low_confidence
- Historical
- Yes
Dates
- Event date
- 2026-11-17T00:00:00.000Z
Reasoning: Historical manganese intercept from 1950s drilling, presented for context and not verified by modern standards, with low grade.
Negative factors
- Historical data, not verified by modern standards
- Low grade for manganese
- No QA/QC documentation
Evidence · table
“3.31”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
M-96Michalová · manganeseGrade: 9Grade Unit: %Intercept: 4.5 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- M-96
- Project
- Michalová
- Commodity
- manganese
- Region
- slovakia
- Reported Region
- slovakia
- Ticker
- UPPR.CN
Geometry
- Grade
- 9
- Grade Unit
- %
- Intercept
- 4.5 m
- From
- 10.5 m
- To
- 15 m
- Hole Depth
- 25.9 m
- Intercept Depth
- 10.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- M-96:10.5-15
QA/QC
- Laboratory
- state laboratories of the period
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- low_confidence
- Historical
- Yes
Dates
- Event date
- 2026-11-17T00:00:00.000Z
Reasoning: Historical composite manganese intercept from 1950s drilling, presented for context and not verified by modern standards.
Negative factors
- Historical data, not verified by modern standards
- No QA/QC documentation
Evidence · table
“9.0”
Context: 4.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
M-114Michalová · manganeseGrade: 18.33Grade Unit: %Intercept: 0.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- M-114
- Project
- Michalová
- Commodity
- manganese
- Region
- slovakia
- Reported Region
- slovakia
- Ticker
- UPPR.CN
Geometry
- Grade
- 18.33
- Grade Unit
- %
- Intercept
- 0.4 m
- From
- 8.6 m
- To
- 9 m
- Hole Depth
- 2.2 m
- Intercept Depth
- 8.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- M-114:8.6-9
QA/QC
- Laboratory
- state laboratories of the period
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- low_confidence
- Historical
- Yes
Dates
- Event date
- 2026-11-17T00:00:00.000Z
Reasoning: Historical manganese intercept from 1950s drilling, presented for context and not verified by modern standards.
Negative factors
- Historical data, not verified by modern standards
- No QA/QC documentation
Evidence · table
“18.33”
Context: 0.40
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
M-114Michalová · manganeseGrade: 9.02Grade Unit: %Intercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- M-114
- Project
- Michalová
- Commodity
- manganese
- Region
- slovakia
- Reported Region
- slovakia
- Ticker
- UPPR.CN
Geometry
- Grade
- 9.02
- Grade Unit
- %
- Intercept
- 1 m
- From
- 9 m
- To
- 10 m
- Hole Depth
- 2.2 m
- Intercept Depth
- 9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- M-114:9-10
QA/QC
- Laboratory
- state laboratories of the period
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- low_confidence
- Historical
- Yes
Dates
- Event date
- 2026-11-17T00:00:00.000Z
Reasoning: Historical manganese intercept from 1950s drilling, presented for context and not verified by modern standards.
Negative factors
- Historical data, not verified by modern standards
- No QA/QC documentation
Evidence · table
“9.02”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
M-114Michalová · manganeseGrade: 14.21Grade Unit: %Intercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- M-114
- Project
- Michalová
- Commodity
- manganese
- Region
- slovakia
- Reported Region
- slovakia
- Ticker
- UPPR.CN
Geometry
- Grade
- 14.21
- Grade Unit
- %
- Intercept
- 1 m
- From
- 10 m
- To
- 11 m
- Hole Depth
- 2.2 m
- Intercept Depth
- 10 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- M-114:10-11
QA/QC
- Laboratory
- state laboratories of the period
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- low_confidence
- Historical
- Yes
Dates
- Event date
- 2026-11-17T00:00:00.000Z
Reasoning: Historical manganese intercept from 1950s drilling, presented for context and not verified by modern standards.
Negative factors
- Historical data, not verified by modern standards
- No QA/QC documentation
Evidence · table
“14.21”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
M-114Michalová · manganeseGrade: 1.9Grade Unit: %Intercept: 0.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- M-114
- Project
- Michalová
- Commodity
- manganese
- Region
- slovakia
- Reported Region
- slovakia
- Ticker
- UPPR.CN
Geometry
- Grade
- 1.9
- Grade Unit
- %
- Intercept
- 0.4 m
- From
- 11 m
- To
- 11.4 m
- Hole Depth
- 2.2 m
- Intercept Depth
- 11 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- M-114:11-11.4
QA/QC
- Laboratory
- state laboratories of the period
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- low_confidence
- Historical
- Yes
Dates
- Event date
- 2026-11-17T00:00:00.000Z
Reasoning: Historical manganese intercept from 1950s drilling, presented for context and not verified by modern standards, with low grade.
Negative factors
- Historical data, not verified by modern standards
- Low grade for manganese
- No QA/QC documentation
Evidence · table
“1.90”
Context: 0.40
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
M-114Michalová · manganeseGrade: 11.2Grade Unit: %Intercept: 2.8 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- M-114
- Project
- Michalová
- Commodity
- manganese
- Region
- slovakia
- Reported Region
- slovakia
- Ticker
- UPPR.CN
Geometry
- Grade
- 11.2
- Grade Unit
- %
- Intercept
- 2.8 m
- From
- 8.6 m
- To
- 11.4 m
- Hole Depth
- 2.2 m
- Intercept Depth
- 8.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- M-114:8.6-11.4
QA/QC
- Laboratory
- state laboratories of the period
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- low_confidence
- Historical
- Yes
Dates
- Event date
- 2026-11-17T00:00:00.000Z
Reasoning: Historical composite manganese intercept from 1950s drilling, presented for context and not verified by modern standards.
Negative factors
- Historical data, not verified by modern standards
- No QA/QC documentation
Evidence · table
“11.2”
Context: 2.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.