SLAM Exploration Completes Goodwin Dril Program Highlighted by New Discovery 2,000 Meters Northwest of Logan Zone and 1.53% Cu-Eq Over 14.45 Meters; New Slam President Hosting Exhibit at the 2026 New Orleans Investment Conference (NOIC)
Original announcement by jmn on
- Company
- SLAM Exploration Ltd.
- Ticker
- SXL
- Exchange
- TSXV
- Region
- New Brunswick
- Primary commodity
- Copper
- Secondary commodities
- Nickel, Cobalt
- Document categories
- Drill results, Other
- Extracted
- 2026-10-26 12:29:42 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
SLAM Exploration announced significant results from its 2026 diamond drilling program at the Goodwin Copper-Nickel-Cobalt Project in New Brunswick, highlighted by a new discovery 2,000 meters northwest of the Logan zone. Key intercepts include 14.45 meters grading 1.54% Cu-Eq in hole GW26-33 and 41.3 meters grading 0.76% Cu-Eq in hole GW26-29. The program involved 19 holes totaling 3,350 meters, with assays pending for 213 samples from the remaining holes, and the company's President will be attending upcoming investment conferences.
Reasoning: The announcement reports significant new drill results, including a new discovery that substantially extends the known mineralization at the Goodwin project. High-grade copper equivalent intercepts are a strong positive, and the company provides transparent details on its QA/QC and metal equivalent calculations. The primary negative is the lack of true width disclosure and cut-off grade.
Positive factors
- New discovery in hole GW26-36 extends mineralization 2,000 meters northwest of the Logan zone, indicating significant exploration potential.
- High-grade copper equivalent intercepts, including 14.45 meters at 1.54% Cu-Eq and 1.9 meters at 3.35% Cu-Eq, demonstrate strong mineralization.
- Transparent reporting of metal equivalent calculation, including metal prices and recovery assumptions.
- Comprehensive QA/QC procedures disclosed, including certified laboratory and Qualified Person sign-off.
Negative factors
- True widths of intercepts have not yet been determined, which may overstate actual thickness.
- No explicit cut-off grade disclosed for reporting intervals, limiting comparability.
- Some results were previously reported, reducing the novelty of those specific intercepts, though the compilation and new discovery are novel.
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 61

Classification and evidence
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Hole GW26-33 returned 1.9 core-meters of 3.35% Cu-Eq, which is an exceptional grade for copper equivalent.
Evidence · table
“3.35”
Context: 1.90
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: Hole GW26-36 opened a new area of sulphide mineralization two kilometers to the northwest of the Logan zone, indicating a significant step-out.
Evidence · text
“Hole GW26-36 opened a new area of sulphide mineralization two kilometers to the northwest of the Logan zone.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release mentions ALS Chemex laboratory, certified reference standards and blanks, and a Qualified Person (Mike Taylor, P.Geo.) approving the contents.
Evidence · text
“ALS Chemex laboratory (ALS) in Moncton. ALS will perform multi-element analysis using ME-ICP41. Quality control samples, comprising certified reference standards and blanks, were inserted at regular intervals in accordance with industry-standard protocols. Mike Taylor, P.Geo., Chairman of the Board of SLAM Exploration Ltd., is a qualified person as defined by National Instrument 43-101 and has approved the contents of this news release.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: The calculation for Cu-Eq 95% is explicitly provided, including metal prices and a 95% recovery rate.
Evidence · text
“Cu-Eq 95% = 0.95 × [Cu% + (Ni% × Ni price ÷ Cu price) + (Co% × Co price ÷ Cu price)]”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: The document states that lengths are core lengths and true widths have not yet been determined.
Evidence · text
“Lengths are core lengths; true widths have not yet been determined.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No explicit cut-off grade is stated for the reported drill intervals.
Evidence · text
“The table below highlights selected composited Cu-Eq 95% assay results received to date from the 2026 Goodwin drill program.”
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: The company is 'looking for the potential feeder zone to connect these mineral deposits at depth' and suggests the new discovery 'has the potential to be a lateral extension of the Logan zone'.
Evidence · text
“We are still looking for the potential feeder zone to connect these mineral deposits at depth. ... the new discovery has the potential to be a lateral extension of the Logan zone”
Extracted facts
Stored fact records: 61. Some facts used in scoring do not have a stored record.
Drill Results (61)
GW26-27Goodwin · copperGrade: 0.168Grade Unit: %Intercept: 37.5 mView all detailsHide details
Identity
- Hole ID
- GW26-27
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.168
- Grade Unit
- %
- Intercept
- 37.5 m
- From
- 37 m
- To
- 74.5 m
- Hole Depth
- 110 m
- Intercept Depth
- 37 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-27:37-74.5
- Mining Method
- unknown
Location
- Easting
- 697310
- Northing
- 5239345
- CRS
- NAD83 UTM Zone 19
- Elevation
- 393 m
- Azimuth
- 215 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.41
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent intercept is of weak grade and moderate width. While the metal equivalent calculation is transparent, the lack of true width and cut-off grade disclosure reduces confidence.
Positive factors
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.41”
Context: 37.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-27Goodwin · nickelGrade: 0.154Grade Unit: %Intercept: 37.5 mView all detailsHide details
Identity
- Hole ID
- GW26-27
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.154
- Grade Unit
- %
- Intercept
- 37.5 m
- From
- 37 m
- To
- 74.5 m
- Hole Depth
- 110 m
- Intercept Depth
- 37 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-27:37-74.5
- Mining Method
- unknown
Location
- Easting
- 697310
- Northing
- 5239345
- CRS
- NAD83 UTM Zone 19
- Elevation
- 393 m
- Azimuth
- 215 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel intercept is of weak grade and moderate width, contributing to the overall program results but not a highlight on its own. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.154”
Context: 37.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-27Goodwin · cobaltGrade: 0.034Grade Unit: %Intercept: 37.5 mView all detailsHide details
Identity
- Hole ID
- GW26-27
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.034
- Grade Unit
- %
- Intercept
- 37.5 m
- From
- 37 m
- To
- 74.5 m
- Hole Depth
- 110 m
- Intercept Depth
- 37 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-27:37-74.5
- Mining Method
- unknown
Location
- Easting
- 697310
- Northing
- 5239345
- CRS
- NAD83 UTM Zone 19
- Elevation
- 393 m
- Azimuth
- 215 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt intercept is of weak grade and moderate width, contributing to the overall program results but not a highlight on its own. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.034”
Context: 37.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-27Goodwin · copperGrade: 0.202Grade Unit: %Intercept: 16.9 mView all detailsHide details
Identity
- Hole ID
- GW26-27
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.202
- Grade Unit
- %
- Intercept
- 16.9 m
- From
- 57 m
- To
- 73.9 m
- Hole Depth
- 110 m
- Intercept Depth
- 37 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-27:57-73.9
- Mining Method
- unknown
Location
- Easting
- 697310
- Northing
- 5239345
- CRS
- NAD83 UTM Zone 19
- Elevation
- 393 m
- Azimuth
- 215 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.5
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent sub-interval is of moderate grade and moderate width. While the metal equivalent calculation is transparent, the lack of true width and cut-off grade disclosure reduces confidence.
Positive factors
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.50”
Context: 16.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-27Goodwin · nickelGrade: 0.196Grade Unit: %Intercept: 16.9 mView all detailsHide details
Identity
- Hole ID
- GW26-27
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.196
- Grade Unit
- %
- Intercept
- 16.9 m
- From
- 57 m
- To
- 73.9 m
- Hole Depth
- 110 m
- Intercept Depth
- 37 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-27:57-73.9
- Mining Method
- unknown
Location
- Easting
- 697310
- Northing
- 5239345
- CRS
- NAD83 UTM Zone 19
- Elevation
- 393 m
- Azimuth
- 215 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel sub-interval is of weak grade and moderate width, contributing to the overall program results but not a highlight on its own. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.196”
Context: 16.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-27Goodwin · cobaltGrade: 0.042Grade Unit: %Intercept: 16.9 mView all detailsHide details
Identity
- Hole ID
- GW26-27
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.042
- Grade Unit
- %
- Intercept
- 16.9 m
- From
- 57 m
- To
- 73.9 m
- Hole Depth
- 110 m
- Intercept Depth
- 37 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-27:57-73.9
- Mining Method
- unknown
Location
- Easting
- 697310
- Northing
- 5239345
- CRS
- NAD83 UTM Zone 19
- Elevation
- 393 m
- Azimuth
- 215 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt sub-interval is of weak grade and moderate width, contributing to the overall program results but not a highlight on its own. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.042”
Context: 16.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-29Goodwin · copperGrade: 0.246Grade Unit: %Intercept: 41.3 mView all detailsHide details
Identity
- Hole ID
- GW26-29
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.246
- Grade Unit
- %
- Intercept
- 41.3 m
- From
- 18.7 m
- To
- 60 m
- Hole Depth
- 137 m
- Intercept Depth
- 18.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-29:18.7-60
- Mining Method
- unknown
Location
- Easting
- 697385
- Northing
- 5239268
- CRS
- NAD83 UTM Zone 19
- Elevation
- 395 m
- Azimuth
- 120 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.76
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent intercept is a strong result due to its significant width and moderate grade, contributing materially to the program. Transparency is good, but true width and cut-off grade are not disclosed.
Positive factors
- Intercept is of moderate grade and strong width (41.3m at 0.76% Cu-Eq).
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.76”
Context: 41.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-29Goodwin · nickelGrade: 0.312Grade Unit: %Intercept: 41.3 mView all detailsHide details
Identity
- Hole ID
- GW26-29
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.312
- Grade Unit
- %
- Intercept
- 41.3 m
- From
- 18.7 m
- To
- 60 m
- Hole Depth
- 137 m
- Intercept Depth
- 18.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-29:18.7-60
- Mining Method
- unknown
Location
- Easting
- 697385
- Northing
- 5239268
- CRS
- NAD83 UTM Zone 19
- Elevation
- 395 m
- Azimuth
- 120 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel intercept is of weak grade but good width, contributing to the overall program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.312”
Context: 41.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-29Goodwin · cobaltGrade: 0.081Grade Unit: %Intercept: 41.3 mView all detailsHide details
Identity
- Hole ID
- GW26-29
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.081
- Grade Unit
- %
- Intercept
- 41.3 m
- From
- 18.7 m
- To
- 60 m
- Hole Depth
- 137 m
- Intercept Depth
- 18.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-29:18.7-60
- Mining Method
- unknown
Location
- Easting
- 697385
- Northing
- 5239268
- CRS
- NAD83 UTM Zone 19
- Elevation
- 395 m
- Azimuth
- 120 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt intercept is of moderate grade and good width, contributing to the overall program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.081”
Context: 41.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-29Goodwin · copperGrade: 0.31Grade Unit: %Intercept: 29.85 mView all detailsHide details
Identity
- Hole ID
- GW26-29
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.31
- Grade Unit
- %
- Intercept
- 29.85 m
- From
- 18.7 m
- To
- 48.55 m
- Hole Depth
- 137 m
- Intercept Depth
- 18.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-29:18.7-48.55
- Mining Method
- unknown
Location
- Easting
- 697385
- Northing
- 5239268
- CRS
- NAD83 UTM Zone 19
- Elevation
- 395 m
- Azimuth
- 120 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.96
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent sub-interval is a strong result due to its significant width and strong grade, contributing materially to the program. Transparency is good, but true width and cut-off grade are not disclosed.
Positive factors
- Intercept is of strong grade and good width (29.85m at 0.96% Cu-Eq).
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.96”
Context: 29.85
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-29Goodwin · nickelGrade: 0.394Grade Unit: %Intercept: 29.85 mView all detailsHide details
Identity
- Hole ID
- GW26-29
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.394
- Grade Unit
- %
- Intercept
- 29.85 m
- From
- 18.7 m
- To
- 48.55 m
- Hole Depth
- 137 m
- Intercept Depth
- 18.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-29:18.7-48.55
- Mining Method
- unknown
Location
- Easting
- 697385
- Northing
- 5239268
- CRS
- NAD83 UTM Zone 19
- Elevation
- 395 m
- Azimuth
- 120 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel sub-interval is of weak grade but good width, contributing to the overall program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.394”
Context: 29.85
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-29Goodwin · cobaltGrade: 0.101Grade Unit: %Intercept: 29.85 mView all detailsHide details
Identity
- Hole ID
- GW26-29
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.101
- Grade Unit
- %
- Intercept
- 29.85 m
- From
- 18.7 m
- To
- 48.55 m
- Hole Depth
- 137 m
- Intercept Depth
- 18.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-29:18.7-48.55
- Mining Method
- unknown
Location
- Easting
- 697385
- Northing
- 5239268
- CRS
- NAD83 UTM Zone 19
- Elevation
- 395 m
- Azimuth
- 120 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt sub-interval is of moderate grade and good width, contributing to the overall program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.101”
Context: 29.85
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-29Goodwin · copperGrade: 0.337Grade Unit: %Intercept: 22.8 mView all detailsHide details
Identity
- Hole ID
- GW26-29
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.337
- Grade Unit
- %
- Intercept
- 22.8 m
- From
- 22 m
- To
- 44.8 m
- Hole Depth
- 137 m
- Intercept Depth
- 18.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-29:22-44.8
- Mining Method
- unknown
Location
- Easting
- 697385
- Northing
- 5239268
- CRS
- NAD83 UTM Zone 19
- Elevation
- 395 m
- Azimuth
- 120 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.05
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent sub-interval is a strong result due to its significant width and strong grade, contributing materially to the program. Transparency is good, but true width and cut-off grade are not disclosed.
Positive factors
- Intercept is of strong grade and moderate width (22.8m at 1.05% Cu-Eq).
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“1.05”
Context: 22.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-29Goodwin · nickelGrade: 0.433Grade Unit: %Intercept: 22.8 mView all detailsHide details
Identity
- Hole ID
- GW26-29
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.433
- Grade Unit
- %
- Intercept
- 22.8 m
- From
- 22 m
- To
- 44.8 m
- Hole Depth
- 137 m
- Intercept Depth
- 18.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-29:22-44.8
- Mining Method
- unknown
Location
- Easting
- 697385
- Northing
- 5239268
- CRS
- NAD83 UTM Zone 19
- Elevation
- 395 m
- Azimuth
- 120 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel sub-interval is of weak grade but moderate width, contributing to the overall program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.433”
Context: 22.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-29Goodwin · cobaltGrade: 0.111Grade Unit: %Intercept: 22.8 mView all detailsHide details
Identity
- Hole ID
- GW26-29
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.111
- Grade Unit
- %
- Intercept
- 22.8 m
- From
- 22 m
- To
- 44.8 m
- Hole Depth
- 137 m
- Intercept Depth
- 18.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-29:22-44.8
- Mining Method
- unknown
Location
- Easting
- 697385
- Northing
- 5239268
- CRS
- NAD83 UTM Zone 19
- Elevation
- 395 m
- Azimuth
- 120 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt sub-interval is of moderate grade and moderate width, contributing to the overall program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.111”
Context: 22.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-29Goodwin · nickelGrade: 0.428Grade Unit: %Intercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- GW26-29
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.428
- Grade Unit
- %
- Intercept
- 2.1 m
- From
- 57.9 m
- To
- 60 m
- Hole Depth
- 137 m
- Intercept Depth
- 18.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-29:57.9-60
- Mining Method
- unknown
Location
- Easting
- 697385
- Northing
- 5239268
- CRS
- NAD83 UTM Zone 19
- Elevation
- 395 m
- Azimuth
- 120 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.05
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel sub-interval is of weak grade and narrow width, contributing to the overall program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.428”
Context: 2.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-29Goodwin · cobaltGrade: 0.114Grade Unit: %Intercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- GW26-29
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.114
- Grade Unit
- %
- Intercept
- 2.1 m
- From
- 57.9 m
- To
- 60 m
- Hole Depth
- 137 m
- Intercept Depth
- 18.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-29:57.9-60
- Mining Method
- unknown
Location
- Easting
- 697385
- Northing
- 5239268
- CRS
- NAD83 UTM Zone 19
- Elevation
- 395 m
- Azimuth
- 120 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.05
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt sub-interval is of moderate grade and narrow width, contributing to the overall program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.114”
Context: 2.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-30Goodwin · copperGrade: 0.092Grade Unit: %Intercept: 72 mView all detailsHide details
Identity
- Hole ID
- GW26-30
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.092
- Grade Unit
- %
- Intercept
- 72 m
- From
- 119 m
- To
- 191 m
- Hole Depth
- 221 m
- Intercept Depth
- 119 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-30:119-191
- Mining Method
- unknown
Location
- Easting
- 697670
- Northing
- 5238943
- CRS
- NAD83 UTM Zone 19
- Elevation
- 439 m
- Azimuth
- 150 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.19
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent intercept is of weak grade despite its significant width, limiting its overall materiality. Transparency is good, but true width and cut-off grade are not disclosed.
Positive factors
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Intercept is of weak grade despite significant width.
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.19”
Context: 72.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-30Goodwin · nickelGrade: 0.052Grade Unit: %Intercept: 72 mView all detailsHide details
Identity
- Hole ID
- GW26-30
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.052
- Grade Unit
- %
- Intercept
- 72 m
- From
- 119 m
- To
- 191 m
- Hole Depth
- 221 m
- Intercept Depth
- 119 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-30:119-191
- Mining Method
- unknown
Location
- Easting
- 697670
- Northing
- 5238943
- CRS
- NAD83 UTM Zone 19
- Elevation
- 439 m
- Azimuth
- 150 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel intercept is of weak grade despite its significant width, limiting its overall materiality. True width and cut-off grade are not disclosed.
Negative factors
- Intercept is of weak grade despite significant width.
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.052”
Context: 72.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-30Goodwin · cobaltGrade: 0.02Grade Unit: %Intercept: 72 mView all detailsHide details
Identity
- Hole ID
- GW26-30
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 72 m
- From
- 119 m
- To
- 191 m
- Hole Depth
- 221 m
- Intercept Depth
- 119 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-30:119-191
- Mining Method
- unknown
Location
- Easting
- 697670
- Northing
- 5238943
- CRS
- NAD83 UTM Zone 19
- Elevation
- 439 m
- Azimuth
- 150 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt intercept is of weak grade despite its significant width, limiting its overall materiality. True width and cut-off grade are not disclosed.
Negative factors
- Intercept is of weak grade despite significant width.
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.020”
Context: 72.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-30Goodwin · copperGrade: 0.146Grade Unit: %Intercept: 9.5 mView all detailsHide details
Identity
- Hole ID
- GW26-30
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.146
- Grade Unit
- %
- Intercept
- 9.5 m
- From
- 181.5 m
- To
- 191 m
- Hole Depth
- 221 m
- Intercept Depth
- 119 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-30:181.5-191
- Mining Method
- unknown
Location
- Easting
- 697670
- Northing
- 5238943
- CRS
- NAD83 UTM Zone 19
- Elevation
- 439 m
- Azimuth
- 150 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.31
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent sub-interval is of weak grade and moderate width. While the metal equivalent calculation is transparent, the lack of true width and cut-off grade disclosure reduces confidence.
Positive factors
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.31”
Context: 9.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-30Goodwin · nickelGrade: 0.097Grade Unit: %Intercept: 9.5 mView all detailsHide details
Identity
- Hole ID
- GW26-30
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.097
- Grade Unit
- %
- Intercept
- 9.5 m
- From
- 181.5 m
- To
- 191 m
- Hole Depth
- 221 m
- Intercept Depth
- 119 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-30:181.5-191
- Mining Method
- unknown
Location
- Easting
- 697670
- Northing
- 5238943
- CRS
- NAD83 UTM Zone 19
- Elevation
- 439 m
- Azimuth
- 150 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel sub-interval is of weak grade and moderate width, contributing to the overall program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.097”
Context: 9.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-30Goodwin · cobaltGrade: 0.027Grade Unit: %Intercept: 9.5 mView all detailsHide details
Identity
- Hole ID
- GW26-30
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.027
- Grade Unit
- %
- Intercept
- 9.5 m
- From
- 181.5 m
- To
- 191 m
- Hole Depth
- 221 m
- Intercept Depth
- 119 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-30:181.5-191
- Mining Method
- unknown
Location
- Easting
- 697670
- Northing
- 5238943
- CRS
- NAD83 UTM Zone 19
- Elevation
- 439 m
- Azimuth
- 150 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt sub-interval is of weak grade and moderate width, contributing to the overall program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.027”
Context: 9.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-32Goodwin · copperGrade: 0.15Grade Unit: %Intercept: 48 mView all detailsHide details
Identity
- Hole ID
- GW26-32
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.15
- Grade Unit
- %
- Intercept
- 48 m
- From
- 146 m
- To
- 194 m
- Hole Depth
- 317 m
- Intercept Depth
- 146 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-32:146-194
- Mining Method
- unknown
Location
- Easting
- 697852
- Northing
- 5238964
- CRS
- NAD83 UTM Zone 19
- Elevation
- 426 m
- Azimuth
- 220 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.32
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent intercept is of weak grade and strong width. While the metal equivalent calculation is transparent, the lack of true width and cut-off grade disclosure reduces confidence.
Positive factors
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.32”
Context: 48.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-32Goodwin · nickelGrade: 0.121Grade Unit: %Intercept: 48 mView all detailsHide details
Identity
- Hole ID
- GW26-32
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.121
- Grade Unit
- %
- Intercept
- 48 m
- From
- 146 m
- To
- 194 m
- Hole Depth
- 317 m
- Intercept Depth
- 146 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-32:146-194
- Mining Method
- unknown
Location
- Easting
- 697852
- Northing
- 5238964
- CRS
- NAD83 UTM Zone 19
- Elevation
- 426 m
- Azimuth
- 220 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel intercept is of weak grade and strong width, contributing to the overall program results but not a highlight on its own. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.121”
Context: 48.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-32Goodwin · cobaltGrade: 0.021Grade Unit: %Intercept: 48 mView all detailsHide details
Identity
- Hole ID
- GW26-32
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.021
- Grade Unit
- %
- Intercept
- 48 m
- From
- 146 m
- To
- 194 m
- Hole Depth
- 317 m
- Intercept Depth
- 146 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-32:146-194
- Mining Method
- unknown
Location
- Easting
- 697852
- Northing
- 5238964
- CRS
- NAD83 UTM Zone 19
- Elevation
- 426 m
- Azimuth
- 220 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt intercept is of weak grade and strong width, contributing to the overall program results but not a highlight on its own. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.021”
Context: 48.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-32Goodwin · copperGrade: 0.16Grade Unit: %Intercept: 35 mView all detailsHide details
Identity
- Hole ID
- GW26-32
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.16
- Grade Unit
- %
- Intercept
- 35 m
- From
- 156 m
- To
- 191 m
- Hole Depth
- 317 m
- Intercept Depth
- 146 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-32:156-191
- Mining Method
- unknown
Location
- Easting
- 697852
- Northing
- 5238964
- CRS
- NAD83 UTM Zone 19
- Elevation
- 426 m
- Azimuth
- 220 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.35
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent sub-interval is of weak grade and strong width. While the metal equivalent calculation is transparent, the lack of true width and cut-off grade disclosure reduces confidence.
Positive factors
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.35”
Context: 35.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-32Goodwin · nickelGrade: 0.132Grade Unit: %Intercept: 35 mView all detailsHide details
Identity
- Hole ID
- GW26-32
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.132
- Grade Unit
- %
- Intercept
- 35 m
- From
- 156 m
- To
- 191 m
- Hole Depth
- 317 m
- Intercept Depth
- 146 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-32:156-191
- Mining Method
- unknown
Location
- Easting
- 697852
- Northing
- 5238964
- CRS
- NAD83 UTM Zone 19
- Elevation
- 426 m
- Azimuth
- 220 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel sub-interval is of weak grade and strong width, contributing to the overall program results but not a highlight on its own. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.132”
Context: 35.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-32Goodwin · cobaltGrade: 0.023Grade Unit: %Intercept: 35 mView all detailsHide details
Identity
- Hole ID
- GW26-32
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.023
- Grade Unit
- %
- Intercept
- 35 m
- From
- 156 m
- To
- 191 m
- Hole Depth
- 317 m
- Intercept Depth
- 146 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-32:156-191
- Mining Method
- unknown
Location
- Easting
- 697852
- Northing
- 5238964
- CRS
- NAD83 UTM Zone 19
- Elevation
- 426 m
- Azimuth
- 220 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt sub-interval is of weak grade and strong width, contributing to the overall program results but not a highlight on its own. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.023”
Context: 35.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-32Goodwin · copperGrade: 0.139Grade Unit: %Intercept: 10 mView all detailsHide details
Identity
- Hole ID
- GW26-32
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.139
- Grade Unit
- %
- Intercept
- 10 m
- From
- 240 m
- To
- 250 m
- Hole Depth
- 317 m
- Intercept Depth
- 146 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-32:240-250
- Mining Method
- unknown
Location
- Easting
- 697852
- Northing
- 5238964
- CRS
- NAD83 UTM Zone 19
- Elevation
- 426 m
- Azimuth
- 220 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.38
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent intercept is of weak grade and moderate width. While the metal equivalent calculation is transparent, the lack of true width and cut-off grade disclosure reduces confidence.
Positive factors
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.38”
Context: 10.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-32Goodwin · nickelGrade: 0.133Grade Unit: %Intercept: 10 mView all detailsHide details
Identity
- Hole ID
- GW26-32
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.133
- Grade Unit
- %
- Intercept
- 10 m
- From
- 240 m
- To
- 250 m
- Hole Depth
- 317 m
- Intercept Depth
- 146 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-32:240-250
- Mining Method
- unknown
Location
- Easting
- 697852
- Northing
- 5238964
- CRS
- NAD83 UTM Zone 19
- Elevation
- 426 m
- Azimuth
- 220 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel intercept is of weak grade and moderate width, contributing to the overall program results but not a highlight on its own. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.133”
Context: 10.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-32Goodwin · cobaltGrade: 0.044Grade Unit: %Intercept: 10 mView all detailsHide details
Identity
- Hole ID
- GW26-32
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.044
- Grade Unit
- %
- Intercept
- 10 m
- From
- 240 m
- To
- 250 m
- Hole Depth
- 317 m
- Intercept Depth
- 146 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-32:240-250
- Mining Method
- unknown
Location
- Easting
- 697852
- Northing
- 5238964
- CRS
- NAD83 UTM Zone 19
- Elevation
- 426 m
- Azimuth
- 220 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt intercept is of weak grade and moderate width, contributing to the overall program results but not a highlight on its own. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.044”
Context: 10.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-32Goodwin · copperGrade: 0.072Grade Unit: %Intercept: 26 mView all detailsHide details
Identity
- Hole ID
- GW26-32
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.072
- Grade Unit
- %
- Intercept
- 26 m
- From
- 284 m
- To
- 310 m
- Hole Depth
- 317 m
- Intercept Depth
- 146 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-32:284-310
- Mining Method
- unknown
Location
- Easting
- 697852
- Northing
- 5238964
- CRS
- NAD83 UTM Zone 19
- Elevation
- 426 m
- Azimuth
- 220 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.24
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent intercept is of weak grade despite its moderate width. While the metal equivalent calculation is transparent, the lack of true width and cut-off grade disclosure reduces confidence.
Positive factors
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Intercept is of weak grade despite moderate width.
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.24”
Context: 26.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-32Goodwin · nickelGrade: 0.081Grade Unit: %Intercept: 26 mView all detailsHide details
Identity
- Hole ID
- GW26-32
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.081
- Grade Unit
- %
- Intercept
- 26 m
- From
- 284 m
- To
- 310 m
- Hole Depth
- 317 m
- Intercept Depth
- 146 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-32:284-310
- Mining Method
- unknown
Location
- Easting
- 697852
- Northing
- 5238964
- CRS
- NAD83 UTM Zone 19
- Elevation
- 426 m
- Azimuth
- 220 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel intercept is of weak grade despite its moderate width, limiting its overall materiality. True width and cut-off grade are not disclosed.
Negative factors
- Intercept is of weak grade despite moderate width.
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.081”
Context: 26.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-32Goodwin · cobaltGrade: 0.035Grade Unit: %Intercept: 26 mView all detailsHide details
Identity
- Hole ID
- GW26-32
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.035
- Grade Unit
- %
- Intercept
- 26 m
- From
- 284 m
- To
- 310 m
- Hole Depth
- 317 m
- Intercept Depth
- 146 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-32:284-310
- Mining Method
- unknown
Location
- Easting
- 697852
- Northing
- 5238964
- CRS
- NAD83 UTM Zone 19
- Elevation
- 426 m
- Azimuth
- 220 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt intercept is of weak grade despite its moderate width, limiting its overall materiality. True width and cut-off grade are not disclosed.
Negative factors
- Intercept is of weak grade despite moderate width.
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.035”
Context: 26.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-33Goodwin · copperGrade: 0.663Grade Unit: %Intercept: 14.45 mView all detailsHide details
Identity
- Hole ID
- GW26-33
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.663
- Grade Unit
- %
- Intercept
- 14.45 m
- From
- 33.15 m
- To
- 47.6 m
- Hole Depth
- 233 m
- Intercept Depth
- 33.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-33:33.15-47.6
- Mining Method
- unknown
Location
- Easting
- 697210
- Northing
- 5238879
- CRS
- NAD83 UTM Zone 19
- Elevation
- 456 m
- Azimuth
- 333 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.54
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent intercept is a highly positive result due to its strong grade and moderate width, making it a highlight of the drill program. Transparency is good, but true width and cut-off grade are not disclosed.
Positive factors
- Intercept is of strong grade and moderate width (14.45m at 1.54% Cu-Eq), representing the highest-grade intercept of the season.
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“1.54”
Context: 14.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-33Goodwin · nickelGrade: 0.717Grade Unit: %Intercept: 14.45 mView all detailsHide details
Identity
- Hole ID
- GW26-33
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.717
- Grade Unit
- %
- Intercept
- 14.45 m
- From
- 33.15 m
- To
- 47.6 m
- Hole Depth
- 233 m
- Intercept Depth
- 33.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-33:33.15-47.6
- Mining Method
- unknown
Location
- Easting
- 697210
- Northing
- 5238879
- CRS
- NAD83 UTM Zone 19
- Elevation
- 456 m
- Azimuth
- 333 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel intercept is of moderate grade and moderate width, contributing positively to the program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.717”
Context: 14.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-33Goodwin · cobaltGrade: 0.059Grade Unit: %Intercept: 14.45 mView all detailsHide details
Identity
- Hole ID
- GW26-33
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.059
- Grade Unit
- %
- Intercept
- 14.45 m
- From
- 33.15 m
- To
- 47.6 m
- Hole Depth
- 233 m
- Intercept Depth
- 33.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-33:33.15-47.6
- Mining Method
- unknown
Location
- Easting
- 697210
- Northing
- 5238879
- CRS
- NAD83 UTM Zone 19
- Elevation
- 456 m
- Azimuth
- 333 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt intercept is of moderate grade and moderate width, contributing positively to the program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.059”
Context: 14.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-33Goodwin · copperGrade: 1.268Grade Unit: %Intercept: 1.9 mView all detailsHide details
Identity
- Hole ID
- GW26-33
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 1.268
- Grade Unit
- %
- Intercept
- 1.9 m
- From
- 33.15 m
- To
- 35.05 m
- Hole Depth
- 233 m
- Intercept Depth
- 33.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-33:33.15-35.05
- Mining Method
- unknown
Location
- Easting
- 697210
- Northing
- 5238879
- CRS
- NAD83 UTM Zone 19
- Elevation
- 456 m
- Azimuth
- 333 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.35
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent sub-interval is an exceptional result due to its high grade, making it a bonanza intercept. Transparency is good, but true width and cut-off grade are not disclosed.
Positive factors
- Intercept is of exceptional grade (3.35% Cu-Eq), representing a bonanza intercept.
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“3.35”
Context: 1.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-33Goodwin · nickelGrade: 1.684Grade Unit: %Intercept: 1.9 mView all detailsHide details
Identity
- Hole ID
- GW26-33
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 1.684
- Grade Unit
- %
- Intercept
- 1.9 m
- From
- 33.15 m
- To
- 35.05 m
- Hole Depth
- 233 m
- Intercept Depth
- 33.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-33:33.15-35.05
- Mining Method
- unknown
Location
- Easting
- 697210
- Northing
- 5238879
- CRS
- NAD83 UTM Zone 19
- Elevation
- 456 m
- Azimuth
- 333 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel sub-interval is of strong grade but narrow width, contributing positively to the program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“1.684”
Context: 1.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-33Goodwin · cobaltGrade: 0.136Grade Unit: %Intercept: 1.9 mView all detailsHide details
Identity
- Hole ID
- GW26-33
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.136
- Grade Unit
- %
- Intercept
- 1.9 m
- From
- 33.15 m
- To
- 35.05 m
- Hole Depth
- 233 m
- Intercept Depth
- 33.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-33:33.15-35.05
- Mining Method
- unknown
Location
- Easting
- 697210
- Northing
- 5238879
- CRS
- NAD83 UTM Zone 19
- Elevation
- 456 m
- Azimuth
- 333 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt sub-interval is of strong grade but narrow width, contributing positively to the program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.136”
Context: 1.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-33Goodwin · copperGrade: 1.061Grade Unit: %Intercept: 4.9 mView all detailsHide details
Identity
- Hole ID
- GW26-33
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 1.061
- Grade Unit
- %
- Intercept
- 4.9 m
- From
- 42.7 m
- To
- 47.6 m
- Hole Depth
- 233 m
- Intercept Depth
- 33.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-33:42.7-47.6
- Mining Method
- unknown
Location
- Easting
- 697210
- Northing
- 5238879
- CRS
- NAD83 UTM Zone 19
- Elevation
- 456 m
- Azimuth
- 333 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.52
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent sub-interval is an exceptional result due to its high grade, making it a bonanza intercept. Transparency is good, but true width and cut-off grade are not disclosed.
Positive factors
- Intercept is of exceptional grade (2.52% Cu-Eq), representing a bonanza intercept.
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“2.52”
Context: 4.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-33Goodwin · nickelGrade: 1.182Grade Unit: %Intercept: 4.9 mView all detailsHide details
Identity
- Hole ID
- GW26-33
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 1.182
- Grade Unit
- %
- Intercept
- 4.9 m
- From
- 42.7 m
- To
- 47.6 m
- Hole Depth
- 233 m
- Intercept Depth
- 33.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-33:42.7-47.6
- Mining Method
- unknown
Location
- Easting
- 697210
- Northing
- 5238879
- CRS
- NAD83 UTM Zone 19
- Elevation
- 456 m
- Azimuth
- 333 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel sub-interval is of strong grade but narrow width, contributing positively to the program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“1.182”
Context: 4.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-33Goodwin · cobaltGrade: 0.099Grade Unit: %Intercept: 4.9 mView all detailsHide details
Identity
- Hole ID
- GW26-33
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.099
- Grade Unit
- %
- Intercept
- 4.9 m
- From
- 42.7 m
- To
- 47.6 m
- Hole Depth
- 233 m
- Intercept Depth
- 33.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-33:42.7-47.6
- Mining Method
- unknown
Location
- Easting
- 697210
- Northing
- 5238879
- CRS
- NAD83 UTM Zone 19
- Elevation
- 456 m
- Azimuth
- 333 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt sub-interval is of moderate grade but narrow width, contributing positively to the program results. True width and cut-off grade are not disclosed.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.099”
Context: 4.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-36Goodwin · copperGrade: 0.136Grade Unit: %Intercept: 43.1 mView all detailsHide details
Identity
- Hole ID
- GW26-36
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.136
- Grade Unit
- %
- Intercept
- 43.1 m
- From
- 125.9 m
- To
- 169 m
- Hole Depth
- 212 m
- Intercept Depth
- 125.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-36:125.9-169
- Mining Method
- unknown
Location
- Easting
- 695878
- Northing
- 5240721
- CRS
- NAD83 UTM Zone 19
- Elevation
- 408 m
- Azimuth
- 225 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.44
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent intercept is a highly positive result due to its location within a new discovery area and its significant width, indicating strong step-out potential. Transparency is good, but true width and cut-off grade are not disclosed.
Positive factors
- Intercept is of moderate grade and strong width (43.1m at 0.44% Cu-Eq), representing a new discovery 2,000 meters northwest of the Logan zone.
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.44”
Context: 43.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-36Goodwin · nickelGrade: 0.203Grade Unit: %Intercept: 43.1 mView all detailsHide details
Identity
- Hole ID
- GW26-36
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.203
- Grade Unit
- %
- Intercept
- 43.1 m
- From
- 125.9 m
- To
- 169 m
- Hole Depth
- 212 m
- Intercept Depth
- 125.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-36:125.9-169
- Mining Method
- unknown
Location
- Easting
- 695878
- Northing
- 5240721
- CRS
- NAD83 UTM Zone 19
- Elevation
- 408 m
- Azimuth
- 225 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel intercept is significant due to its location within a new discovery area, indicating step-out potential, despite its weak grade. True width and cut-off grade are not disclosed.
Positive factors
- Intercept is part of a new discovery 2,000 meters northwest of the Logan zone, indicating significant step-out potential.
Negative factors
- Intercept is of weak grade despite significant width.
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.203”
Context: 43.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-36Goodwin · cobaltGrade: 0.041Grade Unit: %Intercept: 43.1 mView all detailsHide details
Identity
- Hole ID
- GW26-36
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.041
- Grade Unit
- %
- Intercept
- 43.1 m
- From
- 125.9 m
- To
- 169 m
- Hole Depth
- 212 m
- Intercept Depth
- 125.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-36:125.9-169
- Mining Method
- unknown
Location
- Easting
- 695878
- Northing
- 5240721
- CRS
- NAD83 UTM Zone 19
- Elevation
- 408 m
- Azimuth
- 225 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt intercept is significant due to its location within a new discovery area, indicating step-out potential, despite its weak grade. True width and cut-off grade are not disclosed.
Positive factors
- Intercept is part of a new discovery 2,000 meters northwest of the Logan zone, indicating significant step-out potential.
Negative factors
- Intercept is of weak grade despite significant width.
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.041”
Context: 43.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-36Goodwin · copperGrade: 0.136Grade Unit: %Intercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- GW26-36
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.136
- Grade Unit
- %
- Intercept
- 2.1 m
- From
- 126.5 m
- To
- 128.6 m
- Hole Depth
- 212 m
- Intercept Depth
- 125.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-36:126.5-128.6
- Mining Method
- unknown
Location
- Easting
- 695878
- Northing
- 5240721
- CRS
- NAD83 UTM Zone 19
- Elevation
- 408 m
- Azimuth
- 225 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.94
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent sub-interval is a strong result due to its grade and location within a new discovery area, despite its narrow width. Transparency is good, but true width and cut-off grade are not disclosed.
Positive factors
- Intercept is of strong grade, part of a new discovery 2,000 meters northwest of the Logan zone, indicating significant step-out potential.
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.94”
Context: 2.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-36Goodwin · nickelGrade: 0.509Grade Unit: %Intercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- GW26-36
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.509
- Grade Unit
- %
- Intercept
- 2.1 m
- From
- 126.5 m
- To
- 128.6 m
- Hole Depth
- 212 m
- Intercept Depth
- 125.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-36:126.5-128.6
- Mining Method
- unknown
Location
- Easting
- 695878
- Northing
- 5240721
- CRS
- NAD83 UTM Zone 19
- Elevation
- 408 m
- Azimuth
- 225 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel sub-interval is significant due to its location within a new discovery area, despite its moderate grade and narrow width. True width and cut-off grade are not disclosed.
Positive factors
- Intercept is part of a new discovery 2,000 meters northwest of the Logan zone, indicating significant step-out potential.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.509”
Context: 2.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-36Goodwin · cobaltGrade: 0.112Grade Unit: %Intercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- GW26-36
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.112
- Grade Unit
- %
- Intercept
- 2.1 m
- From
- 126.5 m
- To
- 128.6 m
- Hole Depth
- 212 m
- Intercept Depth
- 125.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-36:126.5-128.6
- Mining Method
- unknown
Location
- Easting
- 695878
- Northing
- 5240721
- CRS
- NAD83 UTM Zone 19
- Elevation
- 408 m
- Azimuth
- 225 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt sub-interval is significant due to its location within a new discovery area, despite its strong grade and narrow width. True width and cut-off grade are not disclosed.
Positive factors
- Intercept is part of a new discovery 2,000 meters northwest of the Logan zone, indicating significant step-out potential.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.112”
Context: 2.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-36Goodwin · copperGrade: 0.258Grade Unit: %Intercept: 7.7 mView all detailsHide details
Identity
- Hole ID
- GW26-36
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.258
- Grade Unit
- %
- Intercept
- 7.7 m
- From
- 134.3 m
- To
- 142 m
- Hole Depth
- 212 m
- Intercept Depth
- 125.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-36:134.3-142
- Mining Method
- unknown
Location
- Easting
- 695878
- Northing
- 5240721
- CRS
- NAD83 UTM Zone 19
- Elevation
- 408 m
- Azimuth
- 225 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.76
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent sub-interval is a strong result due to its grade, width, and location within a new discovery area, indicating step-out potential. Transparency is good, but true width and cut-off grade are not disclosed.
Positive factors
- Intercept is of moderate grade and moderate width (7.7m at 0.76% Cu-Eq), part of a new discovery 2,000 meters northwest of the Logan zone, indicating significant step-out potential.
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.76”
Context: 7.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-36Goodwin · nickelGrade: 0.334Grade Unit: %Intercept: 7.7 mView all detailsHide details
Identity
- Hole ID
- GW26-36
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.334
- Grade Unit
- %
- Intercept
- 7.7 m
- From
- 134.3 m
- To
- 142 m
- Hole Depth
- 212 m
- Intercept Depth
- 125.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-36:134.3-142
- Mining Method
- unknown
Location
- Easting
- 695878
- Northing
- 5240721
- CRS
- NAD83 UTM Zone 19
- Elevation
- 408 m
- Azimuth
- 225 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel sub-interval is significant due to its location within a new discovery area, despite its weak grade and moderate width. True width and cut-off grade are not disclosed.
Positive factors
- Intercept is part of a new discovery 2,000 meters northwest of the Logan zone, indicating significant step-out potential.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.334”
Context: 7.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-36Goodwin · cobaltGrade: 0.064Grade Unit: %Intercept: 7.7 mView all detailsHide details
Identity
- Hole ID
- GW26-36
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.064
- Grade Unit
- %
- Intercept
- 7.7 m
- From
- 134.3 m
- To
- 142 m
- Hole Depth
- 212 m
- Intercept Depth
- 125.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-36:134.3-142
- Mining Method
- unknown
Location
- Easting
- 695878
- Northing
- 5240721
- CRS
- NAD83 UTM Zone 19
- Elevation
- 408 m
- Azimuth
- 225 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt sub-interval is significant due to its location within a new discovery area, despite its moderate grade and moderate width. True width and cut-off grade are not disclosed.
Positive factors
- Intercept is part of a new discovery 2,000 meters northwest of the Logan zone, indicating significant step-out potential.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.064”
Context: 7.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-36Goodwin · copperGrade: 0.177Grade Unit: %Intercept: 12 mView all detailsHide details
Identity
- Hole ID
- GW26-36
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.177
- Grade Unit
- %
- Intercept
- 12 m
- From
- 157 m
- To
- 169 m
- Hole Depth
- 212 m
- Intercept Depth
- 125.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-36:157-169
- Mining Method
- unknown
Location
- Easting
- 695878
- Northing
- 5240721
- CRS
- NAD83 UTM Zone 19
- Elevation
- 408 m
- Azimuth
- 225 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.51
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This copper equivalent sub-interval is a strong result due to its grade, width, and location within a new discovery area, indicating step-out potential. Transparency is good, but true width and cut-off grade are not disclosed.
Positive factors
- Intercept is of moderate grade and moderate width (12.0m at 0.51% Cu-Eq), part of a new discovery 2,000 meters northwest of the Logan zone, indicating significant step-out potential.
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.51”
Context: 12.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-36Goodwin · nickelGrade: 0.218Grade Unit: %Intercept: 12 mView all detailsHide details
Identity
- Hole ID
- GW26-36
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.218
- Grade Unit
- %
- Intercept
- 12 m
- From
- 157 m
- To
- 169 m
- Hole Depth
- 212 m
- Intercept Depth
- 125.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-36:157-169
- Mining Method
- unknown
Location
- Easting
- 695878
- Northing
- 5240721
- CRS
- NAD83 UTM Zone 19
- Elevation
- 408 m
- Azimuth
- 225 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This nickel sub-interval is significant due to its location within a new discovery area, despite its weak grade and moderate width. True width and cut-off grade are not disclosed.
Positive factors
- Intercept is part of a new discovery 2,000 meters northwest of the Logan zone, indicating significant step-out potential.
Negative factors
- Intercept is of weak grade despite moderate width.
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.218”
Context: 12.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW26-36Goodwin · cobaltGrade: 0.044Grade Unit: %Intercept: 12 mView all detailsHide details
Identity
- Hole ID
- GW26-36
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.044
- Grade Unit
- %
- Intercept
- 12 m
- From
- 157 m
- To
- 169 m
- Hole Depth
- 212 m
- Intercept Depth
- 125.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GW26-36:157-169
- Mining Method
- unknown
Location
- Easting
- 695878
- Northing
- 5240721
- CRS
- NAD83 UTM Zone 19
- Elevation
- 408 m
- Azimuth
- 225 °
- Dip
- -80 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This cobalt sub-interval is significant due to its location within a new discovery area, despite its weak grade and moderate width. True width and cut-off grade are not disclosed.
Positive factors
- Intercept is part of a new discovery 2,000 meters northwest of the Logan zone, indicating significant step-out potential.
Negative factors
- Intercept is of weak grade despite moderate width.
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · table
“0.044”
Context: 12.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW25-19GoodwinIntercept: 56.35 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- GW25-19
- Project
- Goodwin
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Intercept
- 56.35 m
Classification
- Program
- exploration
- Sample Type
- drill
- Mining Method
- unknown
Location
- CRS
- NAD83 UTM Zone 19
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.93
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-01-23T00:00:00.000Z
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This historical copper equivalent sub-interval is a strong result due to its significant width and strong grade, providing context for the current program. Transparency is good, but true width and cut-off grade are not disclosed, and its historical nature reduces novelty.
Positive factors
- Intercept is of strong grade and continuous width (56.35m at 0.93% Cu-Eq).
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- This is a historical result from the 2025 campaign, re-reported for context.
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · text
“56.35 core-meter interval grading 0.93% Cu-Eq”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
GW25-17GoodwinIntercept: 37.5 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- GW25-17
- Project
- Goodwin
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Intercept
- 37.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Mining Method
- unknown
Location
- CRS
- NAD83 UTM Zone 19
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.01
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-01-23T00:00:00.000Z
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: This historical copper equivalent intercept is a strong result due to its significant width and strong grade, providing context for the current program. Transparency is good, but true width and cut-off grade are not disclosed, and its historical nature reduces novelty.
Positive factors
- Intercept is of strong grade and moderate width (37.5-core-meter interval grading 1.01% Cu-Eq).
- Metal equivalent assumptions are disclosed, providing transparency.
Negative factors
- This is a historical result from the 2025 campaign, re-reported for context.
- Apparent width only, true width not determined.
- Cut-off grade for interval reporting is not disclosed.
Evidence · text
“37.5-core-meter interval grading 1.01% Cu-Eq”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
andGoodwin · copperGrade: 0.339Grade Unit: %Intercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Goodwin
- Commodity
- copper
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.339
- Grade Unit
- %
- Intercept
- 2.1 m
- From
- 57.9 m
- To
- 60 m
- Intercept Depth
- 57.9 m
Classification
- Sample Type
- drill
- Group ID
- and:57.9-60
- Mining Method
- unknown
Location
- CRS
- NAD83 UTM Zone 19
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.339 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.7 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.339”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
andGoodwin · nickelGrade: 0.428Grade Unit: %Intercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Goodwin
- Commodity
- nickel
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.428
- Grade Unit
- %
- Intercept
- 2.1 m
- From
- 57.9 m
- To
- 60 m
- Intercept Depth
- 57.9 m
Classification
- Sample Type
- drill
- Group ID
- and:57.9-60
- Mining Method
- unknown
Location
- CRS
- NAD83 UTM Zone 19
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.428 % nickel is weak against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.428”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
andGoodwin · cobaltGrade: 0.114Grade Unit: %Intercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Goodwin
- Commodity
- cobalt
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- SXL
Geometry
- Grade
- 0.114
- Grade Unit
- %
- Intercept
- 2.1 m
- From
- 57.9 m
- To
- 60 m
- Intercept Depth
- 57.9 m
Classification
- Sample Type
- drill
- Group ID
- and:57.9-60
- Mining Method
- unknown
Location
- CRS
- NAD83 UTM Zone 19
QA/QC
- Laboratory
- ALS Chemex laboratory (ALS) in Moncton
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.114 % cobalt is weak against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.114”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "K2 Gold Extends Dragonfly Structure and Identifies Additional High-Grade Gold at Flores Target Zodiac Gold Identifies Ne"
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.