REZ: Quarterly Activities/Appendix 5B Cash Flow Report
Original announcement by asx on
- Company
- Resources & Energy Group Limited
- Ticker
- REZ
- Exchange
- ASX
- Region
- Western Australia
- Primary commodity
- Unavailable
- Secondary commodities
- None reported
- Document categories
- Drill results, Other, Agreement transaction, Resource update
- Extracted
- 2026-10-29 00:18:12 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Resources & Energy Group Limited reported high-grade gold drill results from its Maranoa, Goodenough, and Gigante Grande projects in Western Australia. Key intercepts include 2 m at 15.84 g/t Au at Maranoa and 9 m at 3.97 g/t Au including 1 m at 25.5 g/t Au at Goodenough. The company also executed a long-form JV agreement for gold production at Maranoa and received a A$428,266 R&D Tax Incentive refund, ending the quarter with A$734,000 cash.
Reasoning: The report details new high-grade drill results from multiple projects, confirming and extending mineralization, which is a strong positive. The JV agreement for Maranoa production and a significant R&D refund also contribute positively. However, some results are apparent width only, and a historical re-sampled hole has QA/QC limitations. The resource estimates are restatements of prior announcements.
Positive factors
- High-grade gold intercepts reported from Maranoa and Goodenough projects, exceeding prior average grades.
- Confirmation of gold mineralization in new areas at Gigante Grande, supporting resource extension.
- Execution of a long-form JV agreement for gold production at Maranoa, with Rembrandt Mining funding 100% of capital.
- Receipt of a significant R&D Tax Incentive refund, improving cash position.
Negative factors
- Some drill intercepts are reported as apparent widths only, potentially overstating true thickness.
- Historical drillhole re-sampling at Goodenough lacks sufficient QA/QC for resource estimation.
- The resource estimates presented are historical and not new updates, with the oldest being from 2024.
Facts used in scoring: 59

Extracted facts
Stored fact records: 59. Some facts used in scoring do not have a stored record.
Drill Results (47)
26MRC042Maranoa · goldGrade: 15.84Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 26MRC042
- Project
- Maranoa
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 15.84
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 57 m
- To
- 59 m
- Intercept Depth
- 57 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- 26MRC042:57-59
- Mining Method
- open_pit
Location
- Dip
- -60 °
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 1
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: High-grade intercept from grade control drilling, indicating strong mineralization within the planned mining area. The grade is well above the project's average and resource grade, and the angled hole suggests a reasonable approximation of true width.
Positive factors
- Exceptional gold grade (15.84 g/t) significantly above project average and resource grade.
- Intercept is from grade control drilling, supporting mine planning and definition of mineralized zones.
- Angled hole, so intercept approximates true width.
Evidence · table
“15.84”
Context: 2
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The gold grade of 15.84 g/t is exceptional for an open pit gold deposit.
Evidence · table
“15.84”
Context: 2
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: The document states that intercepts in angled holes approximate true width, and this hole was angled.
Evidence · text
“Intercepts in angled holes approximate true width.”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drilling is described as 'grade control drilling' designed to inform mine planning and define mineralized zones.
Evidence · text
“The grade control drilling is designed to inform mine planning and the definition of mineralised zones under the joint venture”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay by SGS, Perth.
Evidence · text
“Assays by 50 g fire assay (SGS, Perth).”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 1.0 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts reported above a cut-off grade of 1.0 g/t Au, maximum 2 m internal dilution”
26MRC046Maranoa · goldGrade: 2.34Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26MRC046
- Project
- Maranoa
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 2.34
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 56 m
- To
- 57 m
- Intercept Depth
- 56 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- 26MRC046:56-57
- Mining Method
- open_pit
Location
- Dip
- -60 °
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 1
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, below the project's average and resource grade, but still contributes to grade control data. The angled hole suggests a reasonable approximation of true width.
Positive factors
- Intercept is from grade control drilling, supporting mine planning and definition of mineralized zones.
- Angled hole, so intercept approximates true width.
Negative factors
- Grade is below the project's average and resource grade.
Evidence · table
“2.34”
Context: 1
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: The document states that intercepts in angled holes approximate true width, and this hole was angled.
Evidence · text
“Intercepts in angled holes approximate true width.”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drilling is described as 'grade control drilling' designed to inform mine planning and define mineralized zones.
Evidence · text
“The grade control drilling is designed to inform mine planning and the definition of mineralised zones under the joint venture”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay by SGS, Perth.
Evidence · text
“Assays by 50 g fire assay (SGS, Perth).”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 1.0 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts reported above a cut-off grade of 1.0 g/t Au, maximum 2 m internal dilution”
26MRC050Maranoa · goldGrade: 3.25Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 26MRC050
- Project
- Maranoa
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 3.25
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 73 m
- To
- 75 m
- Intercept Depth
- 73 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- 26MRC050:73-75
- Mining Method
- open_pit
Location
- Dip
- -90 °
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 1
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, below the project's average and resource grade. The vertical orientation means the reported width is apparent and likely overstates true thickness.
Positive factors
- Intercept is from grade control drilling, supporting mine planning and definition of mineralized zones.
Negative factors
- Grade is below the project's average and resource grade.
- Vertical hole, so reported intercept is an apparent width approximately twice the true width.
Evidence · table
“3.25”
Context: 2
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states that holes 26MRC050 and 26MRC051 were drilled vertically and reported intercepts are apparent widths of approximately twice the true width.
Evidence · text
“Holes 26MRC050 and 26MRC051 were drilled vertically and reported intercepts are apparent widths of approximately twice the true width.”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drilling is described as 'grade control drilling' designed to inform mine planning and define mineralized zones.
Evidence · text
“The grade control drilling is designed to inform mine planning and the definition of mineralised zones under the joint venture”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay by SGS, Perth.
Evidence · text
“Assays by 50 g fire assay (SGS, Perth).”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 1.0 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts reported above a cut-off grade of 1.0 g/t Au, maximum 2 m internal dilution”
26MRC051Maranoa · goldGrade: 2.76Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- 26MRC051
- Project
- Maranoa
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 2.76
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 72 m
- To
- 76 m
- Intercept Depth
- 72 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- 26MRC051:72-76
- Mining Method
- open_pit
Location
- Dip
- -90 °
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 1
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a moderate width, below the project's average and resource grade. The vertical orientation means the reported width is apparent and likely overstates true thickness.
Positive factors
- Intercept is from grade control drilling, supporting mine planning and definition of mineralized zones.
Negative factors
- Grade is below the project's average and resource grade.
- Vertical hole, so reported intercept is an apparent width approximately twice the true width.
Evidence · table
“2.76”
Context: 4
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states that holes 26MRC050 and 26MRC051 were drilled vertically and reported intercepts are apparent widths of approximately twice the true width.
Evidence · text
“Holes 26MRC050 and 26MRC051 were drilled vertically and reported intercepts are apparent widths of approximately twice the true width.”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drilling is described as 'grade control drilling' designed to inform mine planning and define mineralized zones.
Evidence · text
“The grade control drilling is designed to inform mine planning and the definition of mineralised zones under the joint venture”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay by SGS, Perth.
Evidence · text
“Assays by 50 g fire assay (SGS, Perth).”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 1.0 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts reported above a cut-off grade of 1.0 g/t Au, maximum 2 m internal dilution”
26MRC051Maranoa · goldGrade: 10.38Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- 26MRC051
- Project
- Maranoa
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 10.38
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 81 m
- To
- 85 m
- Intercept Depth
- 81 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- 26MRC051:81-85
- Mining Method
- open_pit
Location
- Dip
- -90 °
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 1
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: High-grade intercept over a moderate width, significantly above the project's average and resource grade. The vertical orientation means the reported width is apparent and likely overstates true thickness, but the grade is still very strong.
Positive factors
- High gold grade (10.38 g/t) significantly above project average and resource grade.
- Intercept is from grade control drilling, supporting mine planning and definition of mineralized zones.
Negative factors
- Vertical hole, so reported intercept is an apparent width approximately twice the true width.
Evidence · table
“10.38”
Context: 4
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The gold grade of 10.38 g/t is exceptional for an open pit gold deposit.
Evidence · table
“10.38”
Context: 4
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states that holes 26MRC050 and 26MRC051 were drilled vertically and reported intercepts are apparent widths of approximately twice the true width.
Evidence · text
“Holes 26MRC050 and 26MRC051 were drilled vertically and reported intercepts are apparent widths of approximately twice the true width.”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drilling is described as 'grade control drilling' designed to inform mine planning and define mineralized zones.
Evidence · text
“The grade control drilling is designed to inform mine planning and the definition of mineralised zones under the joint venture”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay by SGS, Perth.
Evidence · text
“Assays by 50 g fire assay (SGS, Perth).”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 1.0 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts reported above a cut-off grade of 1.0 g/t Au, maximum 2 m internal dilution”
26GERC029Goodenough South · goldGrade: 2.64Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GERC029
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 2.64
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 42 m
- To
- 43 m
- Intercept Depth
- 42 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC029:42-43
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, above the project's average, contributing to resource verification and extension. The reported length is downhole, not true width.
Positive factors
- Grade is above the project's average grade of 1.596 g/t Au.
- Contributes to resource verification and extension.
Negative factors
- Narrow intercept width.
Evidence · table
“2.64”
Context: 1
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC029Goodenough South · goldGrade: 0.53Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GERC029
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.53
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 71 m
- To
- 72 m
- Intercept Depth
- 71 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC029:71-72
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a narrow width, at the cut-off, below the project's average. The reported length is downhole, not true width.
Positive factors
- Contributes to resource verification and extension.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au.
- Narrow intercept width.
Evidence · table
“0.53”
Context: 1
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC029Goodenough South · goldGrade: 1.02Grade Unit: g/tIntercept: 8 mView all detailsHide details
Identity
- Hole ID
- 26GERC029
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1.02
- Grade Unit
- g/t
- Intercept
- 8 m
- From
- 98 m
- To
- 106 m
- Intercept Depth
- 98 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC029:98-106
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a moderate width, below the project's average, but still contributes to resource verification. The reported length is downhole, not true width.
Positive factors
- Moderate intercept width.
- Contributes to resource verification and extension.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au.
Evidence · table
“1.02”
Context: 8
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC029Goodenough South · goldGrade: 1.83Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- 26GERC029
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1.83
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 101 m
- To
- 104 m
- Intercept Depth
- 101 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC029:101-104
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, above the project's average, contributing to resource verification and extension. The reported length is downhole, not true width.
Positive factors
- Grade is above the project's average grade of 1.596 g/t Au.
- Contributes to resource verification and extension.
Negative factors
- Narrow intercept width.
Evidence · table
“1.83”
Context: 3
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC030Goodenough South · goldGrade: 0.65Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 26GERC030
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.65
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 89 m
- To
- 91 m
- Intercept Depth
- 89 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC030:89-91
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a narrow width, at the cut-off, below the project's average. The reported length is downhole, not true width.
Positive factors
- Contributes to resource verification and extension.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au.
- Narrow intercept width.
Evidence · table
“0.65”
Context: 2
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC030Goodenough South · goldGrade: 0.8Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 26GERC030
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.8
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 108 m
- To
- 110 m
- Intercept Depth
- 108 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC030:108-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a narrow width, below the project's average. The reported length is downhole, not true width.
Positive factors
- Contributes to resource verification and extension.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au.
- Narrow intercept width.
Evidence · table
“0.80”
Context: 2
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC030Goodenough South · goldGrade: 1.39Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GERC030
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1.39
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 109 m
- To
- 110 m
- Intercept Depth
- 109 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC030:109-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, below the project's average, but still contributes to resource verification and extension. The reported length is downhole, not true width.
Positive factors
- Contributes to resource verification and extension.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au.
- Narrow intercept width.
Evidence · table
“1.39”
Context: 1
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC031Goodenough South · goldGrade: 0.59Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- 26GERC031
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.59
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 42 m
- To
- 45 m
- Intercept Depth
- 42 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC031:42-45
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a narrow width, at the cut-off, below the project's average. The reported length is downhole, not true width.
Positive factors
- Contributes to resource verification and extension.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au.
Evidence · table
“0.59”
Context: 3
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC031Goodenough South · goldGrade: 1.21Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GERC031
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1.21
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 44 m
- To
- 45 m
- Intercept Depth
- 44 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC031:44-45
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, below the project's average, but still contributes to resource verification and extension. The reported length is downhole, not true width.
Positive factors
- Contributes to resource verification and extension.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au.
- Narrow intercept width.
Evidence · table
“1.21”
Context: 1
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC031Goodenough South · goldGrade: 0.54Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GERC031
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.54
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 76 m
- To
- 77 m
- Intercept Depth
- 76 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC031:76-77
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a narrow width, at the cut-off, below the project's average. The reported length is downhole, not true width.
Positive factors
- Contributes to resource verification and extension.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au.
- Narrow intercept width.
Evidence · table
“0.54”
Context: 1
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC031Goodenough South · goldGrade: 0.66Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GERC031
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.66
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 118 m
- To
- 119 m
- Intercept Depth
- 118 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC031:118-119
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a narrow width, below the project's average. The reported length is downhole, not true width.
Positive factors
- Contributes to resource verification and extension.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au.
- Narrow intercept width.
Evidence · table
“0.66”
Context: 1
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC031Goodenough South · goldGrade: 0.63Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- 26GERC031
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.63
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 129 m
- To
- 133 m
- Intercept Depth
- 129 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC031:129-133
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a moderate width, below the project's average. The reported length is downhole, not true width.
Positive factors
- Contributes to resource verification and extension.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au.
Evidence · table
“0.63”
Context: 4
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC031Goodenough South · goldGrade: 1.61Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GERC031
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1.61
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 132 m
- To
- 133 m
- Intercept Depth
- 132 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC031:132-133
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, above the project's average, contributing to resource verification and extension. The reported length is downhole, not true width.
Positive factors
- Grade is above the project's average grade of 1.596 g/t Au.
- Contributes to resource verification and extension.
Negative factors
- Narrow intercept width.
Evidence · table
“1.61”
Context: 1
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC031Goodenough South · goldGrade: 3.97Grade Unit: g/tIntercept: 9 mView all detailsHide details
Identity
- Hole ID
- 26GERC031
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 3.97
- Grade Unit
- g/t
- Intercept
- 9 m
- From
- 141 m
- To
- 150 m
- Intercept Depth
- 141 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC031:141-150
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: High-grade intercept over a good width, significantly above the project's average, contributing to resource verification and extension. The reported length is downhole, not true width.
Positive factors
- High gold grade (3.97 g/t) significantly above project average.
- Good intercept width (9 m).
- Contributes to resource verification and extension.
Evidence · table
“3.97”
Context: 9
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The gold grade of 3.97 g/t over 9m is strong for an open pit gold deposit, especially with a high-grade sub-interval.
Evidence · table
“3.97”
Context: 9
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
Step-Out ExtensionRejected · positive
Mineralization extended beyond the previously known limit.
Reason: The drilling tested extensions to the west-northwest of the Goodenough Mineral Resource.
Evidence · text
“Most of the April 2026 drilling tested extensions to the west-northwest of the Goodenough Mineral Resource”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC031Goodenough South · goldGrade: 25.5Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GERC031
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 25.5
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 141 m
- To
- 142 m
- Intercept Depth
- 141 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC031:141-142
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Exceptional high-grade intercept, matching the project's best known, confirming strong mineralization. The reported length is downhole, not true width.
Positive factors
- Exceptional gold grade (25.5 g/t) matching the project's best known intercept.
- Contributes to resource verification and extension.
Negative factors
- Narrow intercept width.
Evidence · table
“25.5”
Context: 1
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The gold grade of 25.5 g/t is exceptional for an open pit gold deposit and matches the best grade in RAG comparables.
Evidence · table
“25.5”
Context: 1
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC031Goodenough South · goldGrade: 1.28Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 26GERC031
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1.28
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 148 m
- To
- 150 m
- Intercept Depth
- 148 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 26GERC031:148-150
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, below the project's average, but still contributes to resource verification and extension. The reported length is downhole, not true width.
Positive factors
- Contributes to resource verification and extension.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au.
- Narrow intercept width.
Evidence · table
“1.28”
Context: 2
Tags used in scoring
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au.
Evidence · text
“significant gold intercepts, April 2026 RC drilling (>0.5 g/t Au).”
26GERC034Goodenough South · goldGrade: 2.17Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 26GERC034
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 2.17
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 39 m
- To
- 41 m
- Intercept Depth
- 39 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GERC034:39-41
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, above the project's average, contributing to exploration for extensions. The reported length is downhole, not true width.
Positive factors
- Grade is above the project's average grade of 1.596 g/t Au.
- Contributes to testing for near-surface extensions of gold mineralization.
Negative factors
- Narrow intercept width.
Evidence · text
“2 m @ 2.17 g/t Au from 39 m”
Tags used in scoring
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
26GERC034Goodenough South · goldGrade: 3.18Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GERC034
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 3.18
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 40 m
- To
- 41 m
- Intercept Depth
- 40 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GERC034:40-41
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, above the project's average, contributing to exploration for extensions. The reported length is downhole, not true width.
Positive factors
- Grade is above the project's average grade of 1.596 g/t Au.
- Contributes to testing for near-surface extensions of gold mineralization.
Negative factors
- Narrow intercept width.
Evidence · text
“1 m @ 3.18 g/t Au”
Tags used in scoring
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
26GERC033Goodenough South · goldGrade: 0.73Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 26GERC033
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.73
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 6 m
- To
- 8 m
- Intercept Depth
- 6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GERC033:6-8
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a narrow width, below the project's average, contributing to exploration for extensions. The reported length is downhole, not true width.
Positive factors
- Contributes to testing for near-surface extensions of gold mineralization.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au.
- Narrow intercept width.
Evidence · text
“2 m @ 0.73 g/t Au from 6 m”
Tags used in scoring
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
26GERC035Goodenough South · goldGrade: 0.48Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- 26GERC035
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.48
- Grade Unit
- g/t
- Intercept
- 5 m
- From
- 30 m
- To
- 35 m
- Intercept Depth
- 30 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GERC035:30-35
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a moderate width, below the project's average and cut-off, contributing to exploration for extensions. The reported length is downhole, not true width.
Positive factors
- Moderate intercept width.
- Contributes to testing for near-surface extensions of gold mineralization.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au and below the stated cut-off for significant intercepts.
Evidence · text
“5 m @ 0.48 g/t Au from 30 m”
Tags used in scoring
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
26GERC035Goodenough South · goldGrade: 1.67Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GERC035
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1.67
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 34 m
- To
- 35 m
- Intercept Depth
- 34 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GERC035:34-35
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, above the project's average, contributing to exploration for extensions. The reported length is downhole, not true width.
Positive factors
- Grade is above the project's average grade of 1.596 g/t Au.
- Contributes to testing for near-surface extensions of gold mineralization.
Negative factors
- Narrow intercept width.
Evidence · text
“1 m @ 1.67 g/t Au”
Tags used in scoring
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions assays by 50 g fire assay.
Evidence · text
“Assays by 50 g fire assay.”
Unknown1Goodenough South · goldGrade: 3.3Grade Unit: g/tIntercept: 5 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- Unknown1
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 3.3
- Grade Unit
- g/t
- Intercept
- 5 m
- From
- 72 m
- To
- 77 m
- Intercept Depth
- 72 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- Unknown1:72-77
- Mining Method
- open_pit
QA/QC
- QA/QC Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a moderate width from a re-sampled historical drillhole. While providing geological context, the lack of sufficient QA/QC limits its use for resource estimation and reduces confidence.
Positive factors
- Moderate grade over a moderate width, above the project's average.
- Provides geological information for interpretation and wireframing.
Negative factors
- No sufficient sample quality assurance for resource estimation.
- Historical data re-sampled, not new drilling.
Evidence · text
“5m @ 3.30 g/t Au from 72 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
No QA/QC DisclosureRejected · negative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Reason: The document explicitly states 'There is not sufficient sample quality assurance to use these assay results in a future Mineral Resource estimate'.
Evidence · text
“There is not sufficient sample quality assurance to use these assay results in a future Mineral Resource estimate”
Stale Data Re-releaseRejected · negative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Reason: The results are from a pre-2012 drillhole that was re-sampled, not new drilling.
Evidence · text
“Re-sampled pre-2012 drillhole returned 5 m @ 3.30 g/t Au”
Unknown1Goodenough South · goldGrade: 11.6Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- Unknown1
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 11.6
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 72 m
- To
- 73 m
- Intercept Depth
- 72 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- Unknown1:72-73
- Mining Method
- open_pit
QA/QC
- QA/QC Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: High-grade intercept over a narrow width from a re-sampled historical drillhole. While providing geological context, the lack of sufficient QA/QC limits its use for resource estimation and reduces confidence.
Positive factors
- High gold grade (11.6 g/t) significantly above project average.
- Provides geological information for interpretation and wireframing.
Negative factors
- Narrow intercept width.
- No sufficient sample quality assurance for resource estimation.
- Historical data re-sampled, not new drilling.
Evidence · text
“1 m @ 11.6 g/t Au”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The gold grade of 11.6 g/t is exceptional for an open pit gold deposit.
Evidence · text
“1 m @ 11.6 g/t Au”
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
No QA/QC DisclosureRejected · negative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Reason: The document explicitly states 'There is not sufficient sample quality assurance to use these assay results in a future Mineral Resource estimate'.
Evidence · text
“There is not sufficient sample quality assurance to use these assay results in a future Mineral Resource estimate”
Stale Data Re-releaseRejected · negative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Reason: The results are from a pre-2012 drillhole that was re-sampled, not new drilling.
Evidence · text
“Re-sampled pre-2012 drillhole returned 5 m @ 3.30 g/t Au”
Unknown1Goodenough South · goldGrade: 0.49Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- Unknown1
- Project
- Goodenough South
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.49
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 66 m
- To
- 68 m
- Intercept Depth
- 66 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- Unknown1:66-68
- Mining Method
- open_pit
QA/QC
- QA/QC Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a narrow width from a re-sampled historical drillhole. While providing geological context, the lack of sufficient QA/QC limits its use for resource estimation and reduces confidence.
Positive factors
- Provides geological information for interpretation and wireframing.
Negative factors
- Grade is below the project's average grade of 1.596 g/t Au and below the stated cut-off for significant intercepts.
- No sufficient sample quality assurance for resource estimation.
- Historical data re-sampled, not new drilling.
Evidence · text
“2 m @ 0.49 g/t Au from 66 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Goodenough drilling.
Evidence · text
“All intervals reported as downhole lengths.”
No QA/QC DisclosureRejected · negative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Reason: The document explicitly states 'There is not sufficient sample quality assurance to use these assay results in a future Mineral Resource estimate'.
Evidence · text
“There is not sufficient sample quality assurance to use these assay results in a future Mineral Resource estimate”
Stale Data Re-releaseRejected · negative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Reason: The results are from a pre-2012 drillhole that was re-sampled, not new drilling.
Evidence · text
“Re-sampling returned 5m @ 3.30 g/t Au from 72 m, including 1 m @ 11.6 g/t Au, and 2 m @ 0.49 g/t Au from 66 m.”
26GGRC045Gigante Grande · goldGrade: 0.6Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 26GGRC045
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.6
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 103 m
- To
- 105 m
- Intercept Depth
- 103 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GGRC045:103-105
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a narrow width, below the project's resource grade, but confirms mineralization in a new extension area. The reported length is downhole, not true width.
Positive factors
- Confirms gold mineralization in the Southern Extension area.
Negative factors
- Grade is below the project's resource grade of 0.91 g/t Au.
- Narrow intercept width.
Evidence · table
“0.60”
Context: 2
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC046Gigante Grande · goldGrade: 0.75Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GGRC046
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.75
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 45 m
- To
- 46 m
- Intercept Depth
- 45 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GGRC046:45-46
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a narrow width, below the project's resource grade, but confirms mineralization in a new extension area. The reported length is downhole, not true width.
Positive factors
- Confirms gold mineralization in the Southern Extension area.
Negative factors
- Grade is below the project's resource grade of 0.91 g/t Au.
- Narrow intercept width.
Evidence · table
“0.75”
Context: 1
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC046Gigante Grande · goldGrade: 1.03Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 26GGRC046
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1.03
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 68 m
- To
- 70 m
- Intercept Depth
- 68 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GGRC046:68-70
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, above the project's resource grade, confirming mineralization in a new extension area. The reported length is downhole, not true width.
Positive factors
- Grade is above the project's resource grade of 0.91 g/t Au.
- Confirms gold mineralization in the Southern Extension area.
Negative factors
- Narrow intercept width.
Evidence · table
“1.03”
Context: 2
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC046Gigante Grande · goldGrade: 1.51Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 26GGRC046
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1.51
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 111 m
- To
- 113 m
- Intercept Depth
- 111 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GGRC046:111-113
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, above the project's resource grade, confirming mineralization in a new extension area. The reported length is downhole, not true width.
Positive factors
- Grade is above the project's resource grade of 0.91 g/t Au.
- Confirms gold mineralization in the Southern Extension area.
Negative factors
- Narrow intercept width.
Evidence · table
“1.51”
Context: 2
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC046Gigante Grande · goldGrade: 4.2Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 26GGRC046
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 4.2
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 152 m
- To
- 154 m
- Intercept Depth
- 152 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GGRC046:152-154
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: High-grade intercept over a narrow width, significantly above the project's resource grade, confirming mineralization in a new extension area. The reported length is downhole, not true width.
Positive factors
- High gold grade (4.20 g/t) significantly above project resource grade.
- Confirms gold mineralization in the Southern Extension area, supporting a new mining lease application.
Negative factors
- Narrow intercept width.
Evidence · table
“4.20”
Context: 2
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The gold grade of 4.20 g/t is strong for an open pit gold deposit, especially in an extension area.
Evidence · table
“4.20”
Context: 2
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
Step-Out ExtensionRejected · positive
Mineralization extended beyond the previously known limit.
Reason: The intercept is from the 'Southern Extension' area, approximately 1 km south of the existing resource, supporting a new mining lease application.
Evidence · text
“Gold mineralisation in the Southern Extension supports Mining Lease Application MLA29/437, in a location separate and distinct from the current Gigante Grande Mineral Resource.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC046Gigante Grande · goldGrade: 5.86Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GGRC046
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 5.86
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 152 m
- To
- 153 m
- Intercept Depth
- 152 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GGRC046:152-153
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Exceptional high-grade intercept over a narrow width, significantly above the project's resource grade, confirming mineralization in a new extension area. The reported length is downhole, not true width.
Positive factors
- Exceptional gold grade (5.86 g/t) significantly above project resource grade.
- Confirms gold mineralization in the Southern Extension area, supporting a new mining lease application.
Negative factors
- Narrow intercept width.
Evidence · table
“5.86”
Context: 1
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The gold grade of 5.86 g/t is exceptional for an open pit gold deposit, especially in an extension area.
Evidence · table
“5.86”
Context: 1
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
Step-Out ExtensionRejected · positive
Mineralization extended beyond the previously known limit.
Reason: The intercept is from the 'Southern Extension' area, approximately 1 km south of the existing resource, supporting a new mining lease application.
Evidence · text
“Gold mineralisation in the Southern Extension supports Mining Lease Application MLA29/437, in a location separate and distinct from the current Gigante Grande Mineral Resource.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC046Gigante Grande · goldGrade: 0.59Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GGRC046
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.59
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 158 m
- To
- 159 m
- Intercept Depth
- 158 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GGRC046:158-159
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a narrow width, below the project's resource grade, but confirms mineralization in a new extension area. The reported length is downhole, not true width.
Positive factors
- Confirms gold mineralization in the Southern Extension area.
Negative factors
- Grade is below the project's resource grade of 0.91 g/t Au.
- Narrow intercept width.
Evidence · table
“0.59”
Context: 1
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC046Gigante Grande · goldGrade: 0.56Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GGRC046
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.56
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 162 m
- To
- 163 m
- Intercept Depth
- 162 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GGRC046:162-163
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a narrow width, below the project's resource grade, but confirms mineralization in a new extension area. The reported length is downhole, not true width.
Positive factors
- Confirms gold mineralization in the Southern Extension area.
Negative factors
- Grade is below the project's resource grade of 0.91 g/t Au.
- Narrow intercept width.
Evidence · table
“0.56”
Context: 1
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC048Gigante Grande · goldGrade: 1.36Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GGRC048
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1.36
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 95 m
- To
- 96 m
- Intercept Depth
- 95 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 26GGRC048:95-96
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, above the project's resource grade, confirming mineralization in a new extension area. The reported length is downhole, not true width.
Positive factors
- Grade is above the project's resource grade of 0.91 g/t Au.
- Confirms gold mineralization in the Southern Extension area.
Negative factors
- Narrow intercept width.
Evidence · table
“1.36”
Context: 1
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC049Gigante Grande · goldGrade: 0.65Grade Unit: g/tIntercept: 18 mView all detailsHide details
Identity
- Hole ID
- 26GGRC049
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 0.65
- Grade Unit
- g/t
- Intercept
- 18 m
- From
- 34 m
- To
- 52 m
- Intercept Depth
- 34 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- 26GGRC049:34-52
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Weak grade over a strong width, below the project's resource grade, but confirms continuity of mineralization. The reported length is downhole, not true width.
Positive factors
- Strong intercept width (18 m).
- Confirms continuity of near-surface gold mineralization at the northern extent of the Mineral Resource.
Negative factors
- Grade is below the project's resource grade of 0.91 g/t Au.
Evidence · table
“0.65”
Context: 18
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drilling confirms the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.
Evidence · text
“The results confirm the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC049Gigante Grande · goldGrade: 1.1Grade Unit: g/tIntercept: 9 mView all detailsHide details
Identity
- Hole ID
- 26GGRC049
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1.1
- Grade Unit
- g/t
- Intercept
- 9 m
- From
- 36 m
- To
- 45 m
- Intercept Depth
- 36 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- 26GGRC049:36-45
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a good width, above the project's resource grade, confirming continuity of mineralization. The reported length is downhole, not true width.
Positive factors
- Moderate grade (1.10 g/t) above project resource grade.
- Good intercept width (9 m).
- Confirms continuity of near-surface gold mineralization at the northern extent of the Mineral Resource.
Evidence · table
“1.10”
Context: 9
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drilling confirms the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.
Evidence · text
“The results confirm the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC049Gigante Grande · goldGrade: 1.71Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- 26GGRC049
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1.71
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 41 m
- To
- 44 m
- Intercept Depth
- 41 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- 26GGRC049:41-44
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, above the project's resource grade, confirming continuity of mineralization. The reported length is downhole, not true width.
Positive factors
- Moderate grade (1.71 g/t) above project resource grade.
- Confirms continuity of near-surface gold mineralization at the northern extent of the Mineral Resource.
Negative factors
- Narrow intercept width.
Evidence · table
“1.71”
Context: 3
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drilling confirms the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.
Evidence · text
“The results confirm the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC049Gigante Grande · goldGrade: 3.12Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GGRC049
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 3.12
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 98 m
- To
- 99 m
- Intercept Depth
- 98 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- 26GGRC049:98-99
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: High-grade intercept over a narrow width, significantly above the project's resource grade, confirming continuity of mineralization. The reported length is downhole, not true width.
Positive factors
- High gold grade (3.12 g/t) significantly above project resource grade.
- Confirms continuity of near-surface gold mineralization at the northern extent of the Mineral Resource.
Negative factors
- Narrow intercept width.
Evidence · table
“3.12”
Context: 1
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drilling confirms the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.
Evidence · text
“The results confirm the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC050Gigante Grande · goldGrade: 2.39Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 26GGRC050
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 2.39
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 41 m
- To
- 43 m
- Intercept Depth
- 41 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- 26GGRC050:41-43
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, significantly above the project's resource grade, confirming continuity of mineralization. The reported length is downhole, not true width.
Positive factors
- Moderate grade (2.39 g/t) significantly above project resource grade.
- Confirms continuity of near-surface gold mineralization at the northern extent of the Mineral Resource.
Negative factors
- Narrow intercept width.
Evidence · table
“2.39”
Context: 2
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drilling confirms the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.
Evidence · text
“The results confirm the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC050Gigante Grande · goldGrade: 4.28Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GGRC050
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 4.28
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 41 m
- To
- 42 m
- Intercept Depth
- 41 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- 26GGRC050:41-42
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: High-grade intercept over a narrow width, significantly above the project's resource grade, confirming continuity of mineralization. The reported length is downhole, not true width.
Positive factors
- High gold grade (4.28 g/t) significantly above project resource grade.
- Confirms continuity of near-surface gold mineralization at the northern extent of the Mineral Resource.
Negative factors
- Narrow intercept width.
Evidence · text
“1 m @ 4.28 g/t Au”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The gold grade of 4.28 g/t is strong for an open pit gold deposit.
Evidence · text
“1 m @ 4.28 g/t Au”
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drilling confirms the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.
Evidence · text
“The results confirm the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
26GGRC050Gigante Grande · goldGrade: 1.07Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 26GGRC050
- Project
- Gigante Grande
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1.07
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 60 m
- To
- 61 m
- Intercept Depth
- 60 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- 26GGRC050:60-61
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width, above the project's resource grade, confirming continuity of mineralization. The reported length is downhole, not true width.
Positive factors
- Grade is above the project's resource grade of 0.91 g/t Au.
- Confirms continuity of near-surface gold mineralization at the northern extent of the Mineral Resource.
Negative factors
- Narrow intercept width.
Evidence · table
“1.07”
Context: 1
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drilling confirms the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.
Evidence · text
“The results confirm the continuity of near-surface gold mineralisation at the northern extent of the Mineral Resource.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Compositing TransparentRejected · positive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Reason: The document specifies a cut-off grade of 0.5 g/t Au and a maximum internal dilution of 2 m.
Evidence · text
“Significant intercepts average >0.5 g/t Au, maximum internal dilution 2 m”
GGRC45Kota Paxi · goldGrade: 1Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- GGRC45
- Project
- Kota Paxi
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 1
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 77 m
- To
- 78 m
- Intercept Depth
- 77 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GGRC45:77-78
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width from a previously unreported drillhole, adding new information for exploration targets. The reported length is downhole, not true width.
Positive factors
- Moderate grade (1.00 g/t) from a previously unreported drillhole.
- Contributes to defining targets along the Gigante Grande Mineralised Trend.
Negative factors
- Narrow intercept width.
Evidence · text
“1 m @ 1.00 g/t Au from 77 m”
Tags used in scoring
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
GGRC45Kota Paxi · goldGrade: 2.07Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- GGRC45
- Project
- Kota Paxi
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REZ
Geometry
- Grade
- 2.07
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 87 m
- To
- 88 m
- Intercept Depth
- 87 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- GGRC45:87-88
- Mining Method
- open_pit
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Moderate grade over a narrow width from a previously unreported drillhole, adding new information for exploration targets. The reported length is downhole, not true width.
Positive factors
- Moderate grade (2.07 g/t) from a previously unreported drillhole.
- Contributes to defining targets along the Gigante Grande Mineralised Trend.
Negative factors
- Narrow intercept width.
Evidence · text
“1 m @ 2.07 g/t Au from 87 m”
Tags used in scoring
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The document states 'All intervals reported as downhole lengths' for Gigante Grande drilling.
Evidence · text
“All intervals reported as downhole lengths.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document mentions 50 g fire assay.
Evidence · text
“50 g fire assay.”
Resource Estimates (12)
indicatedEast Menzies Gold Project · goldTonnes: 1271000Grade: 1.38Grade Unit: g/tContained Metal: 56.4Contained Unit: kozHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- East Menzies Gold Project
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REZ
Resource scope
- Estimate type
- resource
- Reporting standards
- jorc
- QP Signed
- Yes
- Qualified person names
- Mr Phil Jankowski
- Resource group id
- resource:8fe418624fba375bef4a
- Deposit or zone
- Goodenough
Resource Data
- Category
- indicated
- Tonnes
- 1271000
- Grade
- 1.38
- Grade Unit
- g/t
- Contained Metal
- 56.4
- Contained Unit
- koz
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
Prior Estimate
- Resource Date
- 2026-03-24
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-03-24T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Restatement of a previously reported Indicated Mineral Resource for Goodenough, compliant with JORC. While providing a baseline, it offers no new information.
Positive factors
- Resource is in the Indicated category, providing reasonable geological confidence.
- Compliant with JORC Code 2012 Edition.
Negative factors
- This is a restatement of a prior estimate, not a new update.
- Effective date is over 6 months old.
Evidence · table
“1,271”
Context: Indicated
inferredEast Menzies Gold Project · goldTonnes: 87000Grade: 1.72Grade Unit: g/tContained Metal: 4.8Contained Unit: kozHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- East Menzies Gold Project
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REZ
Resource scope
- Estimate type
- resource
- Reporting standards
- jorc
- QP Signed
- Yes
- Qualified person names
- Mr Phil Jankowski
- Resource group id
- resource:85aa64a3d0ed3c468c9b
- Deposit or zone
- Goodenough
Resource Data
- Category
- inferred
- Tonnes
- 87000
- Grade
- 1.72
- Grade Unit
- g/t
- Contained Metal
- 4.8
- Contained Unit
- koz
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
Prior Estimate
- Resource Date
- 2026-03-24
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-03-24T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Restatement of a previously reported Inferred Mineral Resource for Goodenough, compliant with JORC. The Inferred category indicates lower confidence, and it offers no new information.
Positive factors
- Compliant with JORC Code 2012 Edition.
Negative factors
- Resource is in the Inferred category, indicating lower geological confidence.
- This is a restatement of a prior estimate, not a new update.
- Effective date is over 6 months old.
Evidence · table
“87”
Context: Inferred
GoodenoughEast Menzies Gold Project · goldTonnes: 1358000Grade: 1.4Grade Unit: g/tContained Metal: 61.2Contained Unit: kozHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- East Menzies Gold Project
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REZ
Resource scope
- Estimate type
- resource
- Reporting standards
- jorc
- QP Signed
- Yes
- Qualified person names
- Mr Phil Jankowski
- Resource group id
- resource:308027aa5366c43a9462
- Deposit or zone
- Goodenough
Resource Data
- Tonnes
- 1358000
- Grade
- 1.4
- Grade Unit
- g/t
- Contained Metal
- 61.2
- Contained Unit
- koz
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t
Prior Estimate
- Resource Date
- 2026-03-24
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-03-24T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Restatement of the total Mineral Resource for Goodenough, compliant with JORC. It provides an overview of the project's resource but no new information.
Positive factors
- Compliant with JORC Code 2012 Edition.
Negative factors
- This is a restatement of a prior estimate, not a new update.
- Effective date is over 6 months old.
Evidence · table
“1,358”
Context: Total
inferredEast Menzies Gold Project · goldTonnes: 1390000Grade: 0.91Grade Unit: g/tContained Metal: 40.7Contained Unit: kozHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- East Menzies Gold Project
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REZ
Resource scope
- Estimate type
- resource
- Reporting standards
- jorc
- QP Signed
- Yes
- Qualified person names
- Mr Phil Jankowski
- Resource group id
- resource:3e8b66169d9f69155758
- Deposit or zone
- Gigante Grande
Resource Data
- Category
- inferred
- Tonnes
- 1390000
- Grade
- 0.91
- Grade Unit
- g/t
- Contained Metal
- 40.7
- Contained Unit
- koz
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
Prior Estimate
- Resource Date
- 2025-09-23
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2025-09-23T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Restatement of a previously reported 100% Inferred Mineral Resource for Gigante Grande, compliant with JORC. The low confidence category and lack of new information limit its significance.
Positive factors
- Compliant with JORC Code 2012 Edition.
Negative factors
- Resource is 100% Inferred, indicating low geological confidence.
- This is a restatement of a prior estimate, not a new update.
- Effective date is over 1 year old.
Evidence · table
“1,390”
Context: Inferred
Gigante GrandeEast Menzies Gold Project · goldTonnes: 1390000Grade: 0.91Grade Unit: g/tContained Metal: 40.7Contained Unit: kozHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- East Menzies Gold Project
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REZ
Resource scope
- Estimate type
- resource
- Reporting standards
- jorc
- QP Signed
- Yes
- Qualified person names
- Mr Phil Jankowski
- Resource group id
- resource:8c66025c8e47e43395b9
- Deposit or zone
- Gigante Grande
Resource Data
- Tonnes
- 1390000
- Grade
- 0.91
- Grade Unit
- g/t
- Contained Metal
- 40.7
- Contained Unit
- koz
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
Prior Estimate
- Resource Date
- 2025-09-23
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2025-09-23T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Restatement of the total Mineral Resource for Gigante Grande, compliant with JORC. It provides an overview of the project's resource but no new information.
Positive factors
- Compliant with JORC Code 2012 Edition.
Negative factors
- This is a restatement of a prior estimate, not a new update.
- Effective date is over 1 year old.
Evidence · table
“1,390”
Context: Total
inferredEast Menzies Gold Project · goldTonnes: 41000Grade: 2.14Grade Unit: g/tContained Metal: 2.9Contained Unit: kozHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- East Menzies Gold Project
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REZ
Resource scope
- Estimate type
- resource
- Reporting standards
- jorc
- QP Signed
- Yes
- Qualified person names
- Mr Phil Jankowski
- Resource group id
- resource:5cc9c418fad0dac94c2a
- Deposit or zone
- Granny Venn
Resource Data
- Category
- inferred
- Tonnes
- 41000
- Grade
- 2.14
- Grade Unit
- g/t
- Contained Metal
- 2.9
- Contained Unit
- koz
- Cutoff Grade
- 1
- Cutoff Unit
- g/t
Prior Estimate
- Resource Date
- 2024
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Restatement of a previously reported 100% Inferred Mineral Resource for Granny Venn, compliant with JORC. The low confidence category and stale effective date limit its significance.
Positive factors
- Compliant with JORC Code 2012 Edition.
Negative factors
- Resource is 100% Inferred, indicating low geological confidence.
- This is a restatement of a prior estimate, not a new update.
- Effective date is over 2 years old, making it a stale estimate.
Evidence · table
“41”
Context: Inferred
Granny VennEast Menzies Gold Project · goldTonnes: 41000Grade: 2.14Grade Unit: g/tContained Metal: 2.9Contained Unit: kozHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- East Menzies Gold Project
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REZ
Resource scope
- Estimate type
- resource
- Reporting standards
- jorc
- QP Signed
- Yes
- Qualified person names
- Mr Phil Jankowski
- Resource group id
- resource:233606f9e829c5688f9f
- Deposit or zone
- Granny Venn
Resource Data
- Tonnes
- 41000
- Grade
- 2.14
- Grade Unit
- g/t
- Contained Metal
- 2.9
- Contained Unit
- koz
- Cutoff Grade
- 1
- Cutoff Unit
- g/t
Prior Estimate
- Resource Date
- 2024
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Restatement of the total Mineral Resource for Granny Venn, compliant with JORC. It provides an overview of the project's resource but no new information, and the estimate is stale.
Positive factors
- Compliant with JORC Code 2012 Edition.
Negative factors
- This is a restatement of a prior estimate, not a new update.
- Effective date is over 2 years old, making it a stale estimate.
Evidence · table
“41”
Context: Total
inferredEast Menzies Gold Project · goldTonnes: 46000Grade: 5.7Grade Unit: g/tContained Metal: 8Contained Unit: kozHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- East Menzies Gold Project
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REZ
Resource scope
- Estimate type
- resource
- Reporting standards
- jorc
- QP Signed
- Yes
- Qualified person names
- Mr Phil Jankowski
- Resource group id
- resource:c28ddcdcdb83d0b36f23
- Deposit or zone
- Maranoa
Resource Data
- Category
- inferred
- Tonnes
- 46000
- Grade
- 5.7
- Grade Unit
- g/t
- Contained Metal
- 8
- Contained Unit
- koz
- Cutoff Grade
- 1
- Cutoff Unit
- g/t
Prior Estimate
- Resource Date
- 2024
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Restatement of a previously reported 100% Inferred Mineral Resource for Maranoa, compliant with JORC. While the grade is high, the low confidence category and stale effective date limit its significance.
Positive factors
- High grade (5.70 g/t Au) for an Inferred resource.
- Compliant with JORC Code 2012 Edition.
Negative factors
- Resource is 100% Inferred, indicating low geological confidence.
- This is a restatement of a prior estimate, not a new update.
- Effective date is over 2 years old, making it a stale estimate.
Evidence · table
“46”
Context: Inferred
MaranoaEast Menzies Gold Project · goldTonnes: 46000Grade: 5.7Grade Unit: g/tContained Metal: 8Contained Unit: kozHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- East Menzies Gold Project
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REZ
Resource scope
- Estimate type
- resource
- Reporting standards
- jorc
- QP Signed
- Yes
- Qualified person names
- Mr Phil Jankowski
- Resource group id
- resource:552c52d4698601973a85
- Deposit or zone
- Maranoa
Resource Data
- Tonnes
- 46000
- Grade
- 5.7
- Grade Unit
- g/t
- Contained Metal
- 8
- Contained Unit
- koz
- Cutoff Grade
- 1
- Cutoff Unit
- g/t
Prior Estimate
- Resource Date
- 2024
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Restatement of the total Mineral Resource for Maranoa, compliant with JORC. It provides an overview of the project's resource but no new information, and the estimate is stale.
Positive factors
- Compliant with JORC Code 2012 Edition.
Negative factors
- This is a restatement of a prior estimate, not a new update.
- Effective date is over 2 years old, making it a stale estimate.
Evidence · table
“46”
Context: Total
indicatedEast Menzies Gold Project · goldTonnes: 1271000Grade: 1.38Grade Unit: g/tContained Metal: 56.4Contained Unit: kozHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- East Menzies Gold Project
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REZ
Resource scope
- Estimate type
- resource
- Reporting standards
- jorc
- QP Signed
- Yes
- Qualified person names
- Mr Phil Jankowski
- Resource group id
- resource:b803c919a3925e43a77e
- Deposit or zone
- Total
Resource Data
- Category
- indicated
- Tonnes
- 1271000
- Grade
- 1.38
- Grade Unit
- g/t
- Contained Metal
- 56.4
- Contained Unit
- koz
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-03-24T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Restatement of the total Indicated Mineral Resource for the East Menzies Gold Project, compliant with JORC. While providing a project-level overview, it offers no new information.
Positive factors
- Resource is in the Indicated category, providing reasonable geological confidence.
- Compliant with JORC Code 2012 Edition.
Negative factors
- This is a restatement of a prior estimate, not a new update.
- Effective date is over 6 months old.
Evidence · table
“1,271”
Context: Total
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inferredEast Menzies Gold Project · goldTonnes: 1564000Grade: 1.12Grade Unit: g/tContained Metal: 56.4Contained Unit: kozHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- East Menzies Gold Project
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REZ
Resource scope
- Estimate type
- resource
- Reporting standards
- jorc
- QP Signed
- Yes
- Qualified person names
- Mr Phil Jankowski
- Resource group id
- resource:87b0d78249f6a0100d1f
- Deposit or zone
- Total
Resource Data
- Category
- inferred
- Tonnes
- 1564000
- Grade
- 1.12
- Grade Unit
- g/t
- Contained Metal
- 56.4
- Contained Unit
- koz
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-03-24T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Restatement of the total Inferred Mineral Resource for the East Menzies Gold Project, compliant with JORC. The low confidence category and lack of new information limit its significance.
Positive factors
- Compliant with JORC Code 2012 Edition.
Negative factors
- Resource is in the Inferred category, indicating lower geological confidence.
- This is a restatement of a prior estimate, not a new update.
- Effective date is over 6 months old.
Evidence · table
“1,564”
Context: Total
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TotalEast Menzies Gold Project · goldTonnes: 2835000Grade: 1.24Grade Unit: g/tContained Metal: 112.8Contained Unit: kozHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- East Menzies Gold Project
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REZ
Resource scope
- Estimate type
- resource
- Reporting standards
- jorc
- QP Signed
- Yes
- Qualified person names
- Mr Phil Jankowski
- Resource group id
- resource:c3ef7aec526098d83f96
- Deposit or zone
- Total
Resource Data
- Tonnes
- 2835000
- Grade
- 1.24
- Grade Unit
- g/t
- Contained Metal
- 112.8
- Contained Unit
- koz
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-03-24T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Restatement of the total Mineral Resource for the East Menzies Gold Project, compliant with JORC. It provides an overview of the project's resource but no new information.
Positive factors
- Compliant with JORC Code 2012 Edition.
Negative factors
- This is a restatement of a prior estimate, not a new update.
- Effective date is over 6 months old.
Evidence · table
“2,835”
Context: Total
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.