REE: Quarterly Activities/Appendix 5B Cash Flow Report
Original announcement by asx on
- Company
- RareX Limited
- Ticker
- REE
- Exchange
- ASX
- Region
- Unavailable
- Primary commodity
- Unavailable
- Secondary commodities
- None reported
- Document categories
- Drill results, Metallurgy, Other
- Extracted
- 2026-10-30 08:29:10 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
RareX Limited reported a new copper sulphide discovery at its Khaleesi Project from a maiden RC drilling program, with pXRF readings indicating up to 0.57% Cu over 74m in hole KRC012. The company also announced the highest rare earth and phosphate recoveries to date from metallurgical testwork at its Cummins Range Project, along with viable extraction pathways for gallium and scandium. While these technical advancements are positive, the copper results are preliminary pXRF, and the company has an estimated 2.13 quarters of funding available.
Reasoning: The company reported a new copper discovery at its Khaleesi Project from a maiden drill program, with strong pXRF results, and confirmed high rare earth and phosphate recoveries at Cummins Range metallurgical testwork, alongside viable gallium and scandium extraction. However, the copper results are preliminary pXRF, and funding is limited.
Positive factors
- New copper discovery at Khaleesi Project with strong pXRF results from a maiden drill program.
- Maiden drilling validated the geological model at Khaleesi, confirming prospectivity.
- Highest rare earth and phosphate recoveries achieved to date from metallurgical testwork at Cummins Range.
- Viable gallium and strong scandium extraction pathways confirmed at Cummins Range, highlighting multi-element value.
Negative factors
- Copper results are preliminary pXRF values only; certified laboratory assays are pending.
- Metallurgical results are from an optimization-stage program, not final feasibility testwork.
- Limited funding runway with an estimated 2.13 quarters of funding available.
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 10

Classification and evidence
Mill Routeneutral
Processing via mill or concentrator (CIL, CIP, tank leach, flotation).
Why it applies: the document describes a flotation route ("flotation")
Gravity Routeneutral
Gravity separation forms a material part of the flowsheet.
Why it applies: the document describes a gravity route ("gravity")
Single Domain Onlynegative
Testing limited to one composite or domain — representativeness not established.
Why it applies: only one composite was tested
Extracted facts
Stored fact records: 10. Some facts used in scoring do not have a stored record.
Drill Results (6)
KRC012Khaleesi · copperGrade: 940Grade Unit: ppmIntercept: 74 mView all detailsHide details
Identity
- Hole ID
- KRC012
- Project
- Khaleesi
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REE
Geometry
- Grade
- 940
- Grade Unit
- ppm
- Intercept
- 74 m
- From
- 77 m
- To
- 151 m
- Intercept Depth
- 77 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- KRC012:77-151
Location
- Location
- Niobe Prospect
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- QP Signed
- No
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-30T00:00:00.000Z
Reasoning: Maiden drill program identified significant copper mineralization via pXRF, indicating a new exploration opportunity, but results are preliminary and assays are pending.
Positive factors
- New copper discovery in maiden drill program.
- Significant intercept length.
- Expands the Niobe exploration opportunity.
Negative factors
- Results are preliminary pXRF values, not certified assays.
- Assays are pending, introducing uncertainty.
- No true width stated.
Evidence · text
“Portable XRF analysis of the drill spoil showed 74m at 940ppm Cu from 77m”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The interval is given as downhole width (74m) with no true width or drill orientation disclosed.
Evidence · text
“74m at 940ppm Cu from 77m”
No QA/QC DisclosureRejected · negative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Reason: The release explicitly states that XRF results are preliminary field values and not equivalent to certified laboratory assays, and that laboratory assays are required.
Evidence · text
“Cautionary Statement: The XRF results reported in this announcement are preliminary field values only. They are not equivalent to certified laboratory assays and should not be considered a proxy for quantitative analysis. Certified laboratory assays are required to determine the actual grades and widths of the mineralisation. Laboratory assays are currently expected to be received in 4-6 weeks and will be reported as soon as they become available.”
Cut-off UndisclosedRejected · negative
High-grade interval reported without stating the cut-off grade used for compositing.
Reason: The pXRF results are reported without stating the cut-off grade used for compositing the 74m interval.
Evidence · text
“Portable XRF analysis of the drill spoil showed 74m at 940ppm Cu from 77m”
KRC012Khaleesi · copperGrade: 5724Grade Unit: ppmView all detailsHide details
Identity
- Hole ID
- KRC012
- Project
- Khaleesi
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REE
Geometry
- Grade
- 5724
- Grade Unit
- ppm
Classification
- Program
- exploration
- Sample Type
- drill
Location
- Location
- Niobe Prospect
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- QP Signed
- No
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-30T00:00:00.000Z
Reasoning: Peak pXRF value indicates high-grade copper, but it's a preliminary field value and not a continuous intercept, with assays pending.
Positive factors
- Very high peak pXRF grade.
- Indicates potential for higher-grade zones within the discovery.
Negative factors
- Results are preliminary pXRF values, not certified assays.
- Assays are pending, introducing uncertainty.
- Peak value, not a continuous interval.
Evidence · text
“Indicative pXRF readings returned a peak of 5,724ppm Cu (0.57%)”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
No QA/QC DisclosureRejected · negative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Reason: The release explicitly states that XRF results are preliminary field values and not equivalent to certified laboratory assays, and that laboratory assays are required.
Evidence · text
“Cautionary Statement: The XRF results reported in this announcement are preliminary field values only. They are not equivalent to certified laboratory assays and should not be considered a proxy for quantitative analysis. Certified laboratory assays are required to determine the actual grades and widths of the mineralisation. Laboratory assays are currently expected to be received in 4-6 weeks and will be reported as soon as they become available.”
Cut-off UndisclosedRejected · negative
High-grade interval reported without stating the cut-off grade used for compositing.
Reason: The peak pXRF value is reported without stating the cut-off grade used for any associated interval.
Evidence · text
“Indicative pXRF readings returned a peak of 5,724ppm Cu (0.57%)”
KRC007Khaleesi · copperGrade: 960Grade Unit: ppmIntercept: 8 mView all detailsHide details
Identity
- Hole ID
- KRC007
- Project
- Khaleesi
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- REE
Geometry
- Grade
- 960
- Grade Unit
- ppm
- Intercept
- 8 m
Classification
- Program
- exploration
- Sample Type
- drill
Location
- Location
- Niobe Prospect
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- QP Signed
- No
- QA/QC Methods
- standards
Deleterious
- Deleterious Flag
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-30T00:00:00.000Z
Reasoning: Elevated copper identified via pXRF in another hole, supporting the prospectivity of the area, but results are preliminary and interval details are limited.
Positive factors
- Elevated copper identified in another hole, supporting prospectivity.
Negative factors
- Results are preliminary pXRF values, not certified assays.
- Assays are pending, introducing uncertainty.
- No from/to depth provided for the interval.
Evidence · text
“Drill hole KRC007, 900m to the north-east, also had elevated copper, with 8m at 960ppm Cu.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: The interval is given as downhole width (8m) with no true width or drill orientation disclosed.
Evidence · text
“8m at 960ppm Cu”
No QA/QC DisclosureRejected · negative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Reason: The release explicitly states that XRF results are preliminary field values and not equivalent to certified laboratory assays, and that laboratory assays are required.
Evidence · text
“Cautionary Statement: The XRF results reported in this announcement are preliminary field values only. They are not equivalent to certified laboratory assays and should not be considered a proxy for quantitative analysis. Certified laboratory assays are required to determine the actual grades and widths of the mineralisation. Laboratory assays are currently expected to be received in 4-6 weeks and will be reported as soon as they become available.”
Cut-off UndisclosedRejected · negative
High-grade interval reported without stating the cut-off grade used for compositing.
Reason: The pXRF results are reported without stating the cut-off grade used for compositing the 8m interval.
Evidence · text
“8m at 960ppm Cu”
Fact 4Grade Unit: $A'000View all detailsHide details
Identity
- Ticker
- REE
Geometry
- Grade Unit
- $A'000
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-30T00:00:00.000Z
Reasoning: The company reported a net cash outflow from operating activities for the quarter.
Negative factors
- Significant cash outflow from operating activities.
Evidence · table
“(1,303)”
Context: (1,303)
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 5Grade Unit: $A'000View all detailsHide details
Identity
- Ticker
- REE
Geometry
- Grade Unit
- $A'000
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-30T00:00:00.000Z
Reasoning: The company reported its cash and cash equivalents at the end of the quarter.
Evidence · table
“2,780”
Context: 2,780
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 6Grade Unit: quartersView all detailsHide details
Identity
- Ticker
- REE
Geometry
- Grade Unit
- quarters
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-30T00:00:00.000Z
Reasoning: The company has a limited funding runway of just over two quarters, indicating potential need for future capital raises.
Negative factors
- Limited funding runway of just over two quarters.
Evidence · table
“2.13”
Context: 2.13
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metallurgical Results (4)
flotationCummins Range · rare_earth_oxidesRecovery: 74.6 %Historical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Cummins Range
- Commodity
- rare_earth_oxides
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REE
Test Work
- Program Status
- optimization
- Test Type
- flotation
- Processing Route
- conventional flotation beneficiation
- Sample
- rougher recovery
Recovery
- Recovery
- 74.6 %
- Recovery Basis
- actual_test
- Conc. Grade
- 25.15
- Conc. Grade Unit
- %
Lab
- Laboratory
- SGS Lakefield
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-10-11T00:00:00.000Z
Dates
- Event date
- 2026-10-30T00:00:00.000Z
Reasoning: Confirmed highest rare earth recovery and significant grade upgrade, providing a strong basis for further optimization, although the specific recovery percentage was previously reported.
Positive factors
- Confirmed highest rare earth recovery achieved to date.
- Significant TREO upgrade (9.5x).
- Clear technical basis for further optimization identified (monazite liberation).
Negative factors
- Recovery percentage is consistent with previously reported results, indicating low novelty for this specific number.
Evidence · text
“SGS Lakefield testwork achieved a 9.5x TREO upgrade to 25.15% grade, with rougher recovery of up to 74.6%, substantially exceeding all prior Australian beneficiation results for this project.”
flotationCummins Range · phosphateHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Cummins Range
- Commodity
- phosphate
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REE
Test Work
- Program Status
- optimization
- Test Type
- flotation
- Processing Route
- conventional flotation beneficiation
Recovery
- Recovery Basis
- actual_test
Lab
- Laboratory
- SGS Lakefield
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-10-11T00:00:00.000Z
Dates
- Event date
- 2026-10-30T00:00:00.000Z
Reasoning: Confirmed highest phosphate recoveries to date through conventional flotation beneficiation, indicating positive progress in optimization, though the specific percentage is not detailed here.
Positive factors
- Confirmed highest phosphate recoveries achieved to date through conventional flotation beneficiation.
Negative factors
- Specific recovery percentage for phosphate is not explicitly stated in this section.
- Recovery is consistent with previously reported results, indicating low novelty for this specific program.
Evidence · text
“The program has delivered the highest rare earth and phosphate recoveries achieved to date”
extractionCummins Range · galliumHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Cummins Range
- Commodity
- gallium
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REE
Test Work
- Program Status
- optimization
- Test Type
- extraction
- Processing Route
- extraction
Recovery
- Recovery Basis
- actual_test
Lab
- Laboratory
- Gega Elements Pty Ltd
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-07-13T00:00:00.000Z
Dates
- Event date
- 2026-10-30T00:00:00.000Z
Reasoning: Confirmed a viable pathway for near-complete gallium extraction, adding significant value to the multi-element mineralization, consistent with prior reports.
Positive factors
- Confirmed viable pathway for near-complete gallium extraction.
- Highlights the potential value of multi-element mineralization.
Negative factors
- Specific recovery percentage for gallium is not explicitly stated as a number.
- Results are consistent with previously reported information, indicating low novelty.
Evidence · text
“Testwork also confirmed a viable extraction pathway for gallium, with Gega Elements achieving near-complete gallium extraction”
extractionCummins Range · scandiumRecovery: 89 %Historical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Cummins Range
- Commodity
- scandium
- Region
- australia_wa
- Reported Region
- Western Australia
- Ticker
- REE
Test Work
- Program Status
- optimization
- Test Type
- extraction
- Processing Route
- extraction
Recovery
- Recovery
- 89 %
- Recovery Basis
- actual_test
Lab
- Laboratory
- Gega Elements Pty Ltd
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-07-13T00:00:00.000Z
Dates
- Event date
- 2026-10-30T00:00:00.000Z
Reasoning: Confirmed strong scandium recovery, further enhancing the value proposition of the multi-element mineralization, consistent with prior reports.
Positive factors
- Confirmed strong scandium recovery.
- Highlights the potential value of multi-element mineralization.
Negative factors
- Recovery percentage is consistent with previously reported information, indicating low novelty.
Evidence · text
“strong scandium recovery of 89–93%”
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.