Rare Earths Americas Expands Homer-A Mineralized Zone by More Than 60% and Identifies Strongest Heavy Rare Earth Enrichment to Date

Original announcement by jmn on

Company
Rare Earths Americas, Inc.
Ticker
REA
Exchange
NYSE American
Region
Goiás, Brazil
Primary commodity
Rare earths
Secondary commodities
Niobium, Tantalum, Yttrium
Document categories
Drill results
Extracted
2026-11-11 12:20:37 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Rare Earths Americas announced new drill results from its Homer-A project in Goiás, Brazil, significantly expanding the known mineralized footprint by over 60% to 3.5 km². The drilling identified the strongest heavy rare earth enrichment to date, with dysprosium and terbium oxides making up to 8.7% of TREO+Sc in individual samples, and also confirmed polymetallic potential with niobium and tantalum. With only 12% of planned assays received, the company anticipates a strong pipeline of future results and targets a maiden mineral resource estimate in 2027.

Reasoning: The drill results demonstrate significant expansion of the Homer-A mineralized zone, with high-grade heavy rare earth enrichment, particularly dysprosium and terbium, and polymetallic potential with niobium and tantalum, all supported by robust QA/QC. The project remains open for further expansion, and a large number of assays are still pending, indicating strong future potential.

Positive factors

  • Mineralized footprint expanded by over 60% to 3.5 km², indicating significant growth.
  • Highest heavy rare earth enrichment (HREO, DyTb) to date, with individual samples reaching up to 8.7% DyTb of TREO+Sc.
  • Thick, higher-grade mineralized zones intersected close to surface, improving potential economics.
  • Polymetallic potential confirmed with significant niobium and tantalum mineralization alongside rare earths.
  • Strong pipeline of future results with assays pending for over 100 additional holes.
  • Detailed QA/QC procedures disclosed, including certified lab and QP sign-off, ensuring data reliability.
  • True width is approximated by downhole intervals due to vertical drilling and sub-horizontal geometry.

Negative factors

  • Only 12% of planned hole assays have been received, meaning the full extent of the program's success is yet to be determined.
  • The Qualified Person is an employee of a subsidiary, which may present a perceived conflict of interest.
  • Results are classified as 'Exploration Results' under S-K 1300 and do not yet constitute a formal Mineral Resource or Reserve.

Facts used in scoring: 70

Atlas analysis — Rare Earths Americas, Inc.: Rare Earths Americas Expands Homer-A Mineralized Zone by More Than 60% and Identifies Strongest Heavy Rare Earth Enrichment to Date. 2405 ppm over 12 m; 3184 ppm over 7 m; 2225 ppm over 10 m

Extracted facts

Stored fact records: 70. Some facts used in scoring do not have a stored record.

Drill Results (70)

RC-TGA-0009Homer · rare_earthsGrade: 1816Grade Unit: ppmIntercept: 7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
RC-TGA-0009
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
1816
Grade Unit
ppm
Intercept
7 m
True Width
7 m
From
27 m
To
34 m
Hole Depth
80 m
Intercept Depth
27 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0009:27-34
Mining Method
unknown

Location

Location
Interval 3
Easting
511098.3
Northing
8117403.4
Elevation
764.16 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-09-23T00:00:00.000Z

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept from a previously reported hole shows good grade and contributes to the overall understanding of the deposit, with new assays for the deeper portion.

Positive factors

  • Grade of 1816 ppm TREO+Sc is above the peer average (1147.711 ppm) and 75th percentile (1203 ppm).
  • True width is approximated by downhole interval.

Evidence · table

“1816”

Context: 7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0009Homer · rare_earthsGrade: 4050Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
RC-TGA-0009
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
4050
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
31 m
To
32 m
Hole Depth
80 m
Intercept Depth
27 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0009:31-32
Mining Method
unknown

Location

Location
Highest TREO
Easting
511098.3
Northing
8117403.4
Elevation
764.16 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-09-23T00:00:00.000Z

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This high-grade sub-interval from a previously reported hole demonstrates strong rare earth enrichment within the deposit.

Positive factors

  • High-grade intercept of 4050 ppm TREO+Sc, significantly above the peer 75th percentile.
  • True width is approximated by downhole interval.

Evidence · table

“4050”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · rare_earthsGrade: 3184Grade Unit: ppmIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
3184
Grade Unit
ppm
Intercept
7 m
True Width
7 m
From
29 m
To
36 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:29-36
Mining Method
unknown

Location

Location
Interval 1
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the expansion of the mineralized zone and shows good rare earth grades.

Positive factors

  • Strong grade of 3184 ppm TREO+Sc, well above the peer 75th percentile.
  • Good intercept length of 7 meters.
  • True width is approximated by downhole interval.

Evidence · table

“3184”

Context: 7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · niobiumGrade: 784Grade Unit: ppmIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
niobium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
784
Grade Unit
ppm
Intercept
7 m
True Width
7 m
From
29 m
To
36 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:29-36
Mining Method
unknown

Location

Location
Interval 1
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Niobium grade of 784 ppm is above the 700 ppm cut-off.
  • True width is approximated by downhole interval.

Evidence · table

“784”

Context: 7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · tantalumGrade: 43Grade Unit: ppmIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
tantalum
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
43
Grade Unit
ppm
Intercept
7 m
True Width
7 m
From
29 m
To
36 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:29-36
Mining Method
unknown

Location

Location
Interval 1
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Tantalum grade of 43 ppm is in line with previous best grades for the project.
  • True width is approximated by downhole interval.

Evidence · table

“43”

Context: 7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · rare_earthsGrade: 3895Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
3895
Grade Unit
ppm
Intercept
5 m
True Width
5 m
From
30 m
To
35 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:30-35
Mining Method
unknown

Location

Location
including
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This high-grade sub-interval demonstrates strong rare earth enrichment within the broader mineralized zone.

Positive factors

  • High-grade intercept of 3895 ppm TREO+Sc, significantly above the peer 75th percentile.
  • Good intercept length of 5 meters.
  • True width is approximated by downhole interval.

Evidence · table

“3895”

Context: 5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · niobiumGrade: 906Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
niobium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
906
Grade Unit
ppm
Intercept
5 m
True Width
5 m
From
30 m
To
35 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:30-35
Mining Method
unknown

Location

Location
including
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Niobium grade of 906 ppm is above the 700 ppm cut-off and contributes to polymetallic potential.
  • True width is approximated by downhole interval.

Evidence · table

“906”

Context: 5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · tantalumGrade: 52Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
tantalum
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
52
Grade Unit
ppm
Intercept
5 m
True Width
5 m
From
30 m
To
35 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:30-35
Mining Method
unknown

Location

Location
including
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Tantalum grade of 52 ppm is above previous best grades for the project, indicating good polymetallic potential.
  • True width is approximated by downhole interval.

Evidence · table

“52”

Context: 5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · rare_earthsGrade: 4493Grade Unit: ppmIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
4493
Grade Unit
ppm
Intercept
4 m
True Width
4 m
From
31 m
To
35 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:31-35
Mining Method
unknown

Location

Location
and incl.
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This high-grade sub-interval further demonstrates strong rare earth enrichment within the broader mineralized zone.

Positive factors

  • High-grade intercept of 4493 ppm TREO+Sc, significantly above the peer 75th percentile.
  • Good intercept length of 4 meters.
  • True width is approximated by downhole interval.

Evidence · table

“4493”

Context: 4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · niobiumGrade: 948Grade Unit: ppmIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
niobium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
948
Grade Unit
ppm
Intercept
4 m
True Width
4 m
From
31 m
To
35 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:31-35
Mining Method
unknown

Location

Location
and incl.
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Niobium grade of 948 ppm is above the 700 ppm cut-off and contributes to polymetallic potential.
  • True width is approximated by downhole interval.

Evidence · table

“948”

Context: 4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · tantalumGrade: 55Grade Unit: ppmIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
tantalum
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
55
Grade Unit
ppm
Intercept
4 m
True Width
4 m
From
31 m
To
35 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:31-35
Mining Method
unknown

Location

Location
and incl.
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Tantalum grade of 55 ppm is above previous best grades for the project, indicating good polymetallic potential.
  • True width is approximated by downhole interval.

Evidence · table

“55”

Context: 4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · rare_earthsGrade: 2530Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
2530
Grade Unit
ppm
Intercept
5 m
True Width
5 m
From
37 m
To
42 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:37-42
Mining Method
unknown

Location

Location
Interval 2
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the expansion of the mineralized zone and shows good rare earth grades.

Positive factors

  • Good grade of 2530 ppm TREO+Sc, above the peer 75th percentile.
  • Good intercept length of 5 meters.
  • True width is approximated by downhole interval.

Evidence · table

“2530”

Context: 5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · niobiumGrade: 795Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
niobium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
795
Grade Unit
ppm
Intercept
5 m
True Width
5 m
From
37 m
To
42 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:37-42
Mining Method
unknown

Location

Location
Interval 2
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Niobium grade of 795 ppm is above the 700 ppm cut-off.
  • True width is approximated by downhole interval.

Evidence · table

“795”

Context: 5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · tantalumGrade: 43Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
tantalum
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
43
Grade Unit
ppm
Intercept
5 m
True Width
5 m
From
37 m
To
42 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:37-42
Mining Method
unknown

Location

Location
Interval 2
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Tantalum grade of 43 ppm is in line with previous best grades for the project.
  • True width is approximated by downhole interval.

Evidence · table

“43”

Context: 5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · rare_earthsGrade: 3162Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
3162
Grade Unit
ppm
Intercept
3 m
True Width
3 m
From
38 m
To
41 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:38-41
Mining Method
unknown

Location

Location
including
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This high-grade sub-interval further demonstrates strong rare earth enrichment within the broader mineralized zone.

Positive factors

  • High-grade intercept of 3162 ppm TREO+Sc, well above the peer 75th percentile.
  • Good intercept length of 3 meters.
  • True width is approximated by downhole interval.

Evidence · table

“3162”

Context: 3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · niobiumGrade: 956Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
niobium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
956
Grade Unit
ppm
Intercept
3 m
True Width
3 m
From
38 m
To
41 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:38-41
Mining Method
unknown

Location

Location
including
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Niobium grade of 956 ppm is above the 700 ppm cut-off and contributes to polymetallic potential.
  • True width is approximated by downhole interval.

Evidence · table

“956”

Context: 3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · tantalumGrade: 54Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
tantalum
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
54
Grade Unit
ppm
Intercept
3 m
True Width
3 m
From
38 m
To
41 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:38-41
Mining Method
unknown

Location

Location
including
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Tantalum grade of 54 ppm is above previous best grades for the project, indicating good polymetallic potential.
  • True width is approximated by downhole interval.

Evidence · table

“54”

Context: 3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · rare_earthsGrade: 2225Grade Unit: ppmIntercept: 10 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
2225
Grade Unit
ppm
Intercept
10 m
True Width
10 m
From
89 m
To
99 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:89-99
Mining Method
unknown

Location

Location
Interval 3
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the expansion of the mineralized zone and shows good rare earth grades.

Positive factors

  • Good grade of 2225 ppm TREO+Sc, above the peer 75th percentile.
  • Significant intercept length of 10 meters.
  • True width is approximated by downhole interval.

Evidence · table

“2225”

Context: 10

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · niobiumGrade: 649Grade Unit: ppmIntercept: 10 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
niobium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
649
Grade Unit
ppm
Intercept
10 m
True Width
10 m
From
89 m
To
99 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:89-99
Mining Method
unknown

Location

Location
Interval 3
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, but the niobium grade is below the stated cut-off.

Positive factors

  • True width is approximated by downhole interval.

Negative factors

  • Niobium grade of 649 ppm is below the 700 ppm cut-off.

Evidence · table

“649”

Context: 10

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · tantalumGrade: 34Grade Unit: ppmIntercept: 10 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
tantalum
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
34
Grade Unit
ppm
Intercept
10 m
True Width
10 m
From
89 m
To
99 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:89-99
Mining Method
unknown

Location

Location
Interval 3
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • True width is approximated by downhole interval.

Evidence · table

“34”

Context: 10

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · rare_earthsGrade: 2581Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
2581
Grade Unit
ppm
Intercept
5 m
True Width
5 m
From
94 m
To
99 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:94-99
Mining Method
unknown

Location

Location
including
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This high-grade sub-interval further demonstrates strong rare earth enrichment within the broader mineralized zone.

Positive factors

  • Good grade of 2581 ppm TREO+Sc, above the peer 75th percentile.
  • Good intercept length of 5 meters.
  • True width is approximated by downhole interval.

Evidence · table

“2581”

Context: 5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · niobiumGrade: 745Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
niobium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
745
Grade Unit
ppm
Intercept
5 m
True Width
5 m
From
94 m
To
99 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:94-99
Mining Method
unknown

Location

Location
including
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Niobium grade of 745 ppm is above the 700 ppm cut-off.
  • True width is approximated by downhole interval.

Evidence · table

“745”

Context: 5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · tantalumGrade: 41Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
tantalum
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
41
Grade Unit
ppm
Intercept
5 m
True Width
5 m
From
94 m
To
99 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:94-99
Mining Method
unknown

Location

Location
including
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Tantalum grade of 41 ppm is in line with previous best grades for the project.
  • True width is approximated by downhole interval.

Evidence · table

“41”

Context: 5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · rare_earthsGrade: 2726Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
2726
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
96 m
To
98 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:96-98
Mining Method
unknown

Location

Location
and incl.
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This high-grade sub-interval further demonstrates strong rare earth enrichment within the broader mineralized zone.

Positive factors

  • Good grade of 2726 ppm TREO+Sc, above the peer 75th percentile.
  • True width is approximated by downhole interval.

Evidence · table

“2726”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · niobiumGrade: 849Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
niobium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
849
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
96 m
To
98 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:96-98
Mining Method
unknown

Location

Location
and incl.
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Niobium grade of 849 ppm is above the 700 ppm cut-off.
  • True width is approximated by downhole interval.

Evidence · table

“849”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · tantalumGrade: 48Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
tantalum
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
48
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
96 m
To
98 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:96-98
Mining Method
unknown

Location

Location
and incl.
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept indicates polymetallic potential alongside rare earths, contributing to overall project value.

Positive factors

  • Tantalum grade of 48 ppm is above previous best grades for the project, indicating good polymetallic potential.
  • True width is approximated by downhole interval.

Evidence · table

“48”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · rare_earthsGrade: 5413Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
5413
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
32 m
To
33 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:32-33
Mining Method
unknown

Location

Location
Highest TREO
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This highest TREO intercept demonstrates exceptional rare earth enrichment within the deposit.

Positive factors

  • Exceptional grade of 5413 ppm TREO+Sc, significantly above the peer 75th percentile.
  • True width is approximated by downhole interval.

Evidence · table

“5413”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · niobiumGrade: 1230Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
niobium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
1230
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
32 m
To
33 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:32-33
Mining Method
unknown

Location

Location
Highest TREO
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This high-grade niobium intercept further enhances the polymetallic potential of the project.

Positive factors

  • High niobium grade of 1230 ppm, exceeding previous best grades for the project.
  • True width is approximated by downhole interval.

Evidence · table

“1230”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0015Homer · tantalumGrade: 72Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0015
Project
Homer
Commodity
tantalum
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
72
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
32 m
To
33 m
Hole Depth
106 m
Intercept Depth
29 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0015:32-33
Mining Method
unknown

Location

Location
Highest TREO
Easting
511085.63
Northing
8116599.27
Elevation
759.76 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
700
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This highest tantalum intercept further enhances the polymetallic potential of the project.

Positive factors

  • Highest tantalum grade of 72 ppm reported at Homer-A to date, indicating strong polymetallic potential.
  • True width is approximated by downhole interval.

Evidence · table

“72”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0016Homer · rare_earthsGrade: 3373Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0016
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
3373
Grade Unit
ppm
Intercept
3 m
True Width
3 m
From
23 m
To
26 m
Hole Depth
109 m
Intercept Depth
23 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0016:23-26
Mining Method
unknown

Location

Location
Interval 1
Easting
512955.26
Northing
8116391.69
Elevation
784.31 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the expansion of the mineralized zone and shows good rare earth grades.

Positive factors

  • Strong grade of 3373 ppm TREO+Sc, well above the peer 75th percentile.
  • True width is approximated by downhole interval.

Evidence · table

“3373”

Context: 3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0016Homer · rare_earthsGrade: 4302Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0016
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
4302
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
24 m
To
26 m
Hole Depth
109 m
Intercept Depth
23 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0016:24-26
Mining Method
unknown

Location

Location
including
Easting
512955.26
Northing
8116391.69
Elevation
784.31 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This high-grade sub-interval demonstrates strong rare earth enrichment within the broader mineralized zone.

Positive factors

  • High-grade intercept of 4302 ppm TREO+Sc, significantly above the peer 75th percentile.
  • True width is approximated by downhole interval.

Evidence · table

“4302”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0016Homer · rare_earthsGrade: 1888Grade Unit: ppmIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0016
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
1888
Grade Unit
ppm
Intercept
4 m
True Width
4 m
From
27 m
To
31 m
Hole Depth
109 m
Intercept Depth
23 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0016:27-31
Mining Method
unknown

Location

Location
Interval 2
Easting
512955.26
Northing
8116391.69
Elevation
784.31 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the expansion of the mineralized zone and shows good rare earth grades.

Positive factors

  • Grade of 1888 ppm TREO+Sc is above the peer average and 75th percentile.
  • True width is approximated by downhole interval.

Evidence · table

“1888”

Context: 4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0016Homer · rare_earthsGrade: 5310Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0016
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
5310
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
25 m
To
26 m
Hole Depth
109 m
Intercept Depth
23 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0016:25-26
Mining Method
unknown

Location

Location
Highest TREO
Easting
512955.26
Northing
8116391.69
Elevation
784.31 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This highest TREO intercept demonstrates exceptional rare earth enrichment within the deposit.

Positive factors

  • Exceptional grade of 5310 ppm TREO+Sc, significantly above the peer 75th percentile.
  • True width is approximated by downhole interval.

Evidence · table

“5310”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0017Homer · rare_earthsGrade: 1451Grade Unit: ppmIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0017
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
1451
Grade Unit
ppm
Intercept
7 m
True Width
7 m
From
13 m
To
20 m
Hole Depth
120 m
Intercept Depth
13 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0017:13-20
Mining Method
unknown

Location

Location
Interval 1
Easting
513277.03
Northing
8115962.84
Elevation
777.67 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the expansion of the mineralized zone and shows good rare earth grades.

Positive factors

  • Grade of 1451 ppm TREO+Sc is above the peer average and 75th percentile.
  • Good intercept length of 7 meters.
  • True width is approximated by downhole interval.

Evidence · table

“1451”

Context: 7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0017Homer · yttriumGrade: 27Grade Unit: ppmIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0017
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
27
Grade Unit
ppm
Intercept
7 m
True Width
7 m
From
13 m
To
20 m
Hole Depth
120 m
Intercept Depth
13 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0017:13-20
Mining Method
unknown

Location

Location
Interval 1
Easting
513277.03
Northing
8115962.84
Elevation
777.67 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows yttrium presence but at a grade below the stated cut-off.

Positive factors

  • True width is approximated by downhole interval.

Negative factors

  • Yttrium grade of 27 ppm is below the 400 ppm cut-off.

Evidence · table

“27”

Context: 7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0017Homer · rare_earthsGrade: 1393Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0017
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
1393
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
33 m
To
35 m
Hole Depth
120 m
Intercept Depth
13 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0017:33-35
Mining Method
unknown

Location

Location
Interval 2
Easting
513277.03
Northing
8115962.84
Elevation
777.67 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the expansion of the mineralized zone and shows good rare earth grades.

Positive factors

  • Grade of 1393 ppm TREO+Sc is above the peer average and 75th percentile.
  • True width is approximated by downhole interval.

Evidence · table

“1393”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0017Homer · yttriumGrade: 261Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0017
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
261
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
33 m
To
35 m
Hole Depth
120 m
Intercept Depth
13 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0017:33-35
Mining Method
unknown

Location

Location
Interval 2
Easting
513277.03
Northing
8115962.84
Elevation
777.67 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows yttrium presence but at a grade below the stated cut-off.

Positive factors

  • True width is approximated by downhole interval.

Negative factors

  • Yttrium grade of 261 ppm is below the 400 ppm cut-off.

Evidence · table

“261”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0017Homer · rare_earthsGrade: 2845Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0017
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
2845
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
13 m
To
14 m
Hole Depth
120 m
Intercept Depth
13 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0017:13-14
Mining Method
unknown

Location

Location
Highest TREO
Easting
513277.03
Northing
8115962.84
Elevation
777.67 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This highest TREO intercept demonstrates strong rare earth enrichment within the deposit.

Positive factors

  • High-grade intercept of 2845 ppm TREO+Sc, significantly above the peer 75th percentile.
  • True width is approximated by downhole interval.

Evidence · table

“2845”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0017Homer · yttriumGrade: 41Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0017
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
41
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
13 m
To
14 m
Hole Depth
120 m
Intercept Depth
13 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0017:13-14
Mining Method
unknown

Location

Location
Highest TREO
Easting
513277.03
Northing
8115962.84
Elevation
777.67 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows yttrium presence but at a grade below the stated cut-off.

Positive factors

  • True width is approximated by downhole interval.

Negative factors

  • Yttrium grade of 41 ppm is below the 400 ppm cut-off.

Evidence · table

“41”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0018Homer · rare_earthsGrade: 3370Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0018
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
3370
Grade Unit
ppm
Intercept
5 m
True Width
5 m
From
14 m
To
19 m
Hole Depth
120 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0018:14-19
Mining Method
unknown

Location

Location
Interval 1
Easting
513525.84
Northing
8115412.75
Elevation
766.65 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the expansion of the mineralized zone and shows good rare earth grades.

Positive factors

  • Strong grade of 3370 ppm TREO+Sc, well above the peer 75th percentile.
  • Good intercept length of 5 meters.
  • True width is approximated by downhole interval.

Evidence · table

“3370”

Context: 5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0018Homer · yttriumGrade: 1130Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0018
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
1130
Grade Unit
ppm
Intercept
5 m
True Width
5 m
From
14 m
To
19 m
Hole Depth
120 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0018:14-19
Mining Method
unknown

Location

Location
Interval 1
Easting
513525.84
Northing
8115412.75
Elevation
766.65 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows significant yttrium enrichment, contributing to the overall value of the rare earth assemblage.

Positive factors

  • High yttrium grade of 1130 ppm, well above the 400 ppm cut-off.
  • True width is approximated by downhole interval.

Evidence · table

“1130”

Context: 5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0018Homer · rare_earthsGrade: 5335Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0018
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
5335
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
17 m
To
19 m
Hole Depth
120 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0018:17-19
Mining Method
unknown

Location

Location
including
Easting
513525.84
Northing
8115412.75
Elevation
766.65 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This high-grade sub-interval demonstrates exceptional rare earth enrichment, particularly in heavy rare earths, which is a key positive for the project.

Positive factors

  • Exceptional grade of 5335 ppm TREO+Sc, significantly above the peer 75th percentile.
  • High HREO proportion (69.0%) and DyTb (6.6%), indicating strong heavy rare earth enrichment.
  • True width is approximated by downhole interval.

Evidence · table

“5335”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0018Homer · yttriumGrade: 2502Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0018
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
2502
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
17 m
To
19 m
Hole Depth
120 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0018:17-19
Mining Method
unknown

Location

Location
including
Easting
513525.84
Northing
8115412.75
Elevation
766.65 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows significant yttrium enrichment, contributing to the overall value of the rare earth assemblage.

Positive factors

  • High yttrium grade of 2502 ppm, significantly above the 400 ppm cut-off.
  • True width is approximated by downhole interval.

Evidence · table

“2502”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0018Homer · rare_earthsGrade: 1144Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0018
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
1144
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
66 m
To
68 m
Hole Depth
120 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0018:66-68
Mining Method
unknown

Location

Location
Interval 2
Easting
513525.84
Northing
8115412.75
Elevation
766.65 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the overall understanding of the mineralized zone.

Positive factors

  • Grade of 1144 ppm TREO+Sc is in line with the peer average.
  • True width is approximated by downhole interval.

Evidence · table

“1144”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0018Homer · yttriumGrade: 137Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0018
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
137
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
66 m
To
68 m
Hole Depth
120 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0018:66-68
Mining Method
unknown

Location

Location
Interval 2
Easting
513525.84
Northing
8115412.75
Elevation
766.65 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows yttrium presence but at a grade below the stated cut-off.

Positive factors

  • True width is approximated by downhole interval.

Negative factors

  • Yttrium grade of 137 ppm is below the 400 ppm cut-off.

Evidence · table

“137”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0018Homer · rare_earthsGrade: 6746Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0018
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
6746
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
17 m
To
18 m
Hole Depth
120 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0018:17-18
Mining Method
unknown

Location

Location
Highest TREO
Easting
513525.84
Northing
8115412.75
Elevation
766.65 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This highest TREO intercept demonstrates exceptional rare earth enrichment, particularly in heavy rare earths, which is a key positive for the project.

Positive factors

  • Exceptional grade of 6746 ppm TREO+Sc, significantly above the peer 75th percentile.
  • Highest HREO proportion (75.0%) and DyTb (7.0%) to date, indicating very strong heavy rare earth enrichment.
  • True width is approximated by downhole interval.

Evidence · table

“6746”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0018Homer · yttriumGrade: 3480Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0018
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
3480
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
17 m
To
18 m
Hole Depth
120 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0018:17-18
Mining Method
unknown

Location

Location
Highest TREO
Easting
513525.84
Northing
8115412.75
Elevation
766.65 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows significant yttrium enrichment, contributing to the overall value of the rare earth assemblage.

Positive factors

  • High yttrium grade of 3480 ppm, significantly above the 400 ppm cut-off.
  • True width is approximated by downhole interval.

Evidence · table

“3480”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0019AHomer · rare_earthsGrade: 2173Grade Unit: ppmIntercept: 8 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0019A
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
2173
Grade Unit
ppm
Intercept
8 m
True Width
8 m
From
21 m
To
29 m
Hole Depth
120 m
Intercept Depth
21 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0019A:21-29
Mining Method
unknown

Location

Location
Interval 1
Easting
513535.85
Northing
8114987.57
Elevation
757.62 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the expansion of the mineralized zone and shows good rare earth grades with strong heavy rare earth enrichment.

Positive factors

  • Good grade of 2173 ppm TREO+Sc, above the peer 75th percentile.
  • Good intercept length of 8 meters.
  • High HREO proportion (53.1%) and DyTb (6.1%), indicating strong heavy rare earth enrichment.
  • True width is approximated by downhole interval.

Evidence · table

“2173”

Context: 8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0019AHomer · yttriumGrade: 727Grade Unit: ppmIntercept: 8 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0019A
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
727
Grade Unit
ppm
Intercept
8 m
True Width
8 m
From
21 m
To
29 m
Hole Depth
120 m
Intercept Depth
21 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0019A:21-29
Mining Method
unknown

Location

Location
Interval 1
Easting
513535.85
Northing
8114987.57
Elevation
757.62 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows significant yttrium enrichment, contributing to the overall value of the rare earth assemblage.

Positive factors

  • Yttrium grade of 727 ppm is above the 400 ppm cut-off.
  • True width is approximated by downhole interval.

Evidence · table

“727”

Context: 8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0019AHomer · rare_earthsGrade: 4402Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0019A
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
4402
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
24 m
To
26 m
Hole Depth
120 m
Intercept Depth
21 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0019A:24-26
Mining Method
unknown

Location

Location
including
Easting
513535.85
Northing
8114987.57
Elevation
757.62 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This high-grade sub-interval demonstrates exceptional rare earth enrichment, particularly in heavy rare earths, which is a key positive for the project.

Positive factors

  • Exceptional grade of 4402 ppm TREO+Sc, significantly above the peer 75th percentile.
  • Very high HREO proportion (71.3%) and DyTb (8.2%), indicating very strong heavy rare earth enrichment.
  • True width is approximated by downhole interval.

Evidence · table

“4402”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0019AHomer · yttriumGrade: 2001Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0019A
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
2001
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
24 m
To
26 m
Hole Depth
120 m
Intercept Depth
21 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0019A:24-26
Mining Method
unknown

Location

Location
including
Easting
513535.85
Northing
8114987.57
Elevation
757.62 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows significant yttrium enrichment, contributing to the overall value of the rare earth assemblage.

Positive factors

  • High yttrium grade of 2001 ppm, significantly above the 400 ppm cut-off.
  • True width is approximated by downhole interval.

Evidence · table

“2001”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0019AHomer · rare_earthsGrade: 6452Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0019A
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
6452
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
25 m
To
26 m
Hole Depth
120 m
Intercept Depth
21 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0019A:25-26
Mining Method
unknown

Location

Location
Highest TREO
Easting
513535.85
Northing
8114987.57
Elevation
757.62 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This highest TREO intercept demonstrates exceptional rare earth enrichment, particularly in heavy rare earths, which is a key positive for the project.

Positive factors

  • Exceptional grade of 6452 ppm TREO+Sc, significantly above the peer 75th percentile.
  • Highest HREO proportion (76.9%) and DyTb (8.7%) to date, indicating very strong heavy rare earth enrichment.
  • True width is approximated by downhole interval.

Evidence · table

“6452”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0019AHomer · yttriumGrade: 3188Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0019A
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
3188
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
25 m
To
26 m
Hole Depth
120 m
Intercept Depth
21 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0019A:25-26
Mining Method
unknown

Location

Location
Highest TREO
Easting
513535.85
Northing
8114987.57
Elevation
757.62 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows significant yttrium enrichment, contributing to the overall value of the rare earth assemblage.

Positive factors

  • High yttrium grade of 3188 ppm, significantly above the 400 ppm cut-off.
  • True width is approximated by downhole interval.

Evidence · table

“3188”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · rare_earthsGrade: 2350Grade Unit: ppmIntercept: 9 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
2350
Grade Unit
ppm
Intercept
9 m
True Width
9 m
From
12 m
To
21 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:12-21
Mining Method
unknown

Location

Location
Interval 1
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the expansion of the mineralized zone and shows good rare earth grades.

Positive factors

  • Good grade of 2350 ppm TREO+Sc, above the peer 75th percentile.
  • Good intercept length of 9 meters.
  • True width is approximated by downhole interval.

Evidence · table

“2350”

Context: 9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · yttriumGrade: 63Grade Unit: ppmIntercept: 9 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
63
Grade Unit
ppm
Intercept
9 m
True Width
9 m
From
12 m
To
21 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:12-21
Mining Method
unknown

Location

Location
Interval 1
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows yttrium presence but at a grade below the stated cut-off.

Positive factors

  • True width is approximated by downhole interval.

Negative factors

  • Yttrium grade of 63 ppm is below the 400 ppm cut-off.

Evidence · table

“63”

Context: 9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · rare_earthsGrade: 4110Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
4110
Grade Unit
ppm
Intercept
3 m
True Width
3 m
From
16 m
To
19 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:16-19
Mining Method
unknown

Location

Location
including
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This high-grade sub-interval demonstrates strong rare earth enrichment within the broader mineralized zone.

Positive factors

  • High-grade intercept of 4110 ppm TREO+Sc, significantly above the peer 75th percentile.
  • True width is approximated by downhole interval.

Evidence · table

“4110”

Context: 3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · yttriumGrade: 72Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
72
Grade Unit
ppm
Intercept
3 m
True Width
3 m
From
16 m
To
19 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:16-19
Mining Method
unknown

Location

Location
including
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows yttrium presence but at a grade below the stated cut-off.

Positive factors

  • True width is approximated by downhole interval.

Negative factors

  • Yttrium grade of 72 ppm is below the 400 ppm cut-off.

Evidence · table

“72”

Context: 3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · rare_earthsGrade: 1373Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
1373
Grade Unit
ppm
Intercept
3 m
True Width
3 m
From
22 m
To
25 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:22-25
Mining Method
unknown

Location

Location
Interval 2
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the overall understanding of the mineralized zone.

Positive factors

  • Grade of 1373 ppm TREO+Sc is above the peer average.
  • True width is approximated by downhole interval.

Evidence · table

“1373”

Context: 3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · yttriumGrade: 131Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
131
Grade Unit
ppm
Intercept
3 m
True Width
3 m
From
22 m
To
25 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:22-25
Mining Method
unknown

Location

Location
Interval 2
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows yttrium presence but at a grade below the stated cut-off.

Positive factors

  • True width is approximated by downhole interval.

Negative factors

  • Yttrium grade of 131 ppm is below the 400 ppm cut-off.

Evidence · table

“131”

Context: 3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · rare_earthsGrade: 2710Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
2710
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
30 m
To
32 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:30-32
Mining Method
unknown

Location

Location
Interval 3
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the expansion of the mineralized zone and shows good rare earth grades with strong heavy rare earth enrichment.

Positive factors

  • Good grade of 2710 ppm TREO+Sc, above the peer 75th percentile.
  • High HREO proportion (60.1%) and DyTb (5.4%), indicating strong heavy rare earth enrichment.
  • True width is approximated by downhole interval.

Evidence · table

“2710”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · yttriumGrade: 1140Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
1140
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
30 m
To
32 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:30-32
Mining Method
unknown

Location

Location
Interval 3
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows significant yttrium enrichment, contributing to the overall value of the rare earth assemblage.

Positive factors

  • High yttrium grade of 1140 ppm, significantly above the 400 ppm cut-off.
  • True width is approximated by downhole interval.

Evidence · table

“1140”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · rare_earthsGrade: 1060Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
1060
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
54 m
To
56 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:54-56
Mining Method
unknown

Location

Location
Interval 4
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the overall understanding of the mineralized zone.

Positive factors

  • Grade of 1060 ppm TREO+Sc is above the 1000 ppm cut-off.
  • True width is approximated by downhole interval.

Evidence · table

“1060”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · yttriumGrade: 59Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
59
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
54 m
To
56 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:54-56
Mining Method
unknown

Location

Location
Interval 4
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows yttrium presence but at a grade below the stated cut-off.

Positive factors

  • True width is approximated by downhole interval.

Negative factors

  • Yttrium grade of 59 ppm is below the 400 ppm cut-off.

Evidence · table

“59”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · rare_earthsGrade: 1076Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
1076
Grade Unit
ppm
Intercept
3 m
True Width
3 m
From
106 m
To
109 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:106-109
Mining Method
unknown

Location

Location
Interval 5
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the overall understanding of the mineralized zone.

Positive factors

  • Grade of 1076 ppm TREO+Sc is above the 1000 ppm cut-off.
  • True width is approximated by downhole interval.

Evidence · table

“1076”

Context: 3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · yttriumGrade: 49Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
49
Grade Unit
ppm
Intercept
3 m
True Width
3 m
From
106 m
To
109 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:106-109
Mining Method
unknown

Location

Location
Interval 5
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows yttrium presence but at a grade below the stated cut-off.

Positive factors

  • True width is approximated by downhole interval.

Negative factors

  • Yttrium grade of 49 ppm is below the 400 ppm cut-off.

Evidence · table

“49”

Context: 3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · rare_earthsGrade: 4736Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
4736
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
17 m
To
18 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:17-18
Mining Method
unknown

Location

Location
Highest TREO
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This highest TREO intercept demonstrates strong rare earth enrichment within the deposit.

Positive factors

  • High-grade intercept of 4736 ppm TREO+Sc, significantly above the peer 75th percentile.
  • True width is approximated by downhole interval.

Evidence · table

“4736”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0020Homer · yttriumGrade: 79Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0020
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
79
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
17 m
To
18 m
Hole Depth
120 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0020:17-18
Mining Method
unknown

Location

Location
Highest TREO
Easting
513272.88
Northing
8115204.22
Elevation
765.64 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows yttrium presence but at a grade below the stated cut-off.

Positive factors

  • True width is approximated by downhole interval.

Negative factors

  • Yttrium grade of 79 ppm is below the 400 ppm cut-off.

Evidence · table

“79”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0021Homer · rare_earthsGrade: 1401Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0021
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
1401
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
19 m
To
21 m
Hole Depth
81 m
Intercept Depth
19 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0021:19-21
Mining Method
unknown

Location

Location
Interval 1
Easting
513097.06
Northing
8115401.42
Elevation
769.15 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept contributes to the expansion of the mineralized zone and shows good rare earth grades.

Positive factors

  • Grade of 1401 ppm TREO+Sc is above the peer average and 75th percentile.
  • True width is approximated by downhole interval.

Evidence · table

“1401”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0021Homer · yttriumGrade: 22Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0021
Project
Homer
Commodity
yttrium
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
22
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
19 m
To
21 m
Hole Depth
81 m
Intercept Depth
19 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0021:19-21
Mining Method
unknown

Location

Location
Interval 1
Easting
513097.06
Northing
8115401.42
Elevation
769.15 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
400
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Reasoning: This intercept shows yttrium presence but at a grade below the stated cut-off.

Positive factors

  • True width is approximated by downhole interval.

Negative factors

  • Yttrium grade of 22 ppm is below the 400 ppm cut-off.

Evidence · table

“22”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

RC-TGA-0021Homer · rare_earthsGrade: 2405Grade Unit: ppmIntercept: 12 mView all details
Link to this fact

Identity

Hole ID
RC-TGA-0021
Project
Homer
Commodity
rare_earths
Region
brazil
Reported Region
brazil
Ticker
REA

Geometry

Grade
2405
Grade Unit
ppm
Intercept
12 m
True Width
12 m
From
22 m
To
34 m
Hole Depth
81 m
Intercept Depth
19 m

Classification

Program
exploration
Sample Type
drill
Group ID
RC-TGA-0021:22-34
Mining Method
unknown

Location

Location
Interval 2
Easting
513097.06
Northing
8115401.42
Elevation
769.15 m
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-11T00:00:00.000Z

Positive factors

  • Good grade of 2405 ppm TREO+Sc, above the peer 75th percentile.
  • Significant intercept length of 12 meters.

Evidence · table

“2405”

Context: 12

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 12

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "MORE MINING NEWS Newcore Gold Drilling Intersects 2.16 g/t Gold over 37.0 Metres, Including 5.10 g/t Gold over 9.0 Metre"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.