Li-FT cuts high-grade lithium ahead of Quebec study

Original announcement by northernminer on

Company
Li-FT Power
Ticker
LIFT
Exchange
Unavailable
Region
Quebec
Primary commodity
Lithium
Secondary commodities
None reported
Document categories
Drill results, Resource update
Extracted
2026-11-17 16:47:00 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Li-FT Power has reported high-grade lithium oxide intercepts at its Adina project in Quebec, including 45 metres at 2.71% Li2O. These results are expected to support an upcoming resource update and preliminary economic assessment targeted for early 2027.

Reasoning: Strong lithium oxide grades reported in the Galinée zone, which are intended to support an upcoming resource update and economic study.

Positive factors

  • High-grade lithium intercepts reported
  • Drilling supports upcoming resource update and PEA
  • Strategic infrastructure potential at Renard

Negative factors

  • True widths not disclosed

Facts used in scoring: 5

Atlas analysis — Li-FT Power: Li-FT cuts high-grade lithium ahead of Quebec study. 2.71 % over 45 m; indicated 60500000 tonnes

Classification and evidence

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: All intervals are reported as downhole lengths with true thicknesses unknown.

Evidence · text

“All intervals are downhole lengths; true thicknesses are unknown.”

Resource Updateneutral

Revised estimate for an existing resource — compare to prior to assess progress.

Why it applies: The drilling results are intended to feed into an upcoming resource update.

Evidence · text

“The drilling will feed into a resource update and preliminary economic assessment targeted for early 2027.”

Extracted facts

Stored fact records: 5. Some facts used in scoring do not have a stored record.

Drill Results (3)

ALP0007Adina · lithiumGrade: 2.71Grade Unit: %Intercept: 45 mView all details
Link to this fact

Identity

Hole ID
ALP0007
Project
Adina
Commodity
lithium
Region
canada_qc
Reported Region
canada_qc
Ticker
LIFT

Geometry

Grade
2.71
Grade Unit
%
Intercept
45 m
From
164 m
To
209 m
Intercept Depth
164 m

Classification

Program
exploration
Sample Type
drill
Group ID
ALP0007:164-209

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-17T00:00:00.000Z

Reasoning: Significant high-grade lithium oxide intercept.

Positive factors

  • High grade intercept

Negative factors

  • Apparent width only

Evidence · text

“intersected 45 metres at 2.71% lithium oxide at its Adina project in Quebec... The interval began at 164 metres downhole in hole ALP0007”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

ALP0016Adina · lithiumGrade: 2.71Grade Unit: %Intercept: 25 mView all details
Link to this fact

Identity

Hole ID
ALP0016
Project
Adina
Commodity
lithium
Region
canada_qc
Reported Region
canada_qc
Ticker
LIFT

Geometry

Grade
2.71
Grade Unit
%
Intercept
25 m
From
185 m
To
210 m
Intercept Depth
185 m

Classification

Program
exploration
Sample Type
drill
Group ID
ALP0016:185-210

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-17T00:00:00.000Z

Reasoning: High-grade lithium oxide intercept.

Positive factors

  • High grade intercept

Negative factors

  • Apparent width only

Evidence · text

“25 metres at 2.71% lithium oxide from 185 metres in ALP0016”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

ALP0014Adina · lithiumGrade: 3.14Grade Unit: %Intercept: 12 mView all details
Link to this fact

Identity

Hole ID
ALP0014
Project
Adina
Commodity
lithium
Region
canada_qc
Reported Region
canada_qc
Ticker
LIFT

Geometry

Grade
3.14
Grade Unit
%
Intercept
12 m
From
185 m
To
197 m
Intercept Depth
185 m

Classification

Program
exploration
Sample Type
drill
Group ID
ALP0014:185-197

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-17T00:00:00.000Z

Reasoning: Very high grade lithium intercept.

Positive factors

  • Very high grade intercept

Negative factors

  • Apparent width only

Evidence · text

“12 metres at 3.14% from 185 metres in ALP0014”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Resource Estimates (2)

indicatedAdina · lithiumTonnes: 60500000Grade: 1.14Grade Unit: % lithium oxideContained Metal: 690000Contained Unit: tonnes of lithium oxideView all details
Link to this fact

Identity

Project
Adina
Commodity
lithium
Region
canada_qc
Reported Region
Quebec
Ticker
LIFT

Resource scope

Estimate type
resource
Resource group id
resource:064cc26f91313da1822d

Resource Data

Category
indicated
Tonnes
60500000
Grade
1.14
Grade Unit
% lithium oxide
Contained Metal
690000
Contained Unit
tonnes of lithium oxide

Prior Estimate

Resource Date
2026-05-07

Review

Needs Review
No
Historical
No

Dates

Event date
2026-11-17T00:00:00.000Z

Reasoning: Significant indicated resource base.

Positive factors

  • Large indicated resource

Evidence · text

“Adina’s current resource comprises 60.5 million indicated tonnes grading 1.14% lithium oxide, containing about 690,000 tonnes of lithium oxide”

Tags used in scoring

Indicated Resourcepositive

Reasonable geological confidence based on adequate drilling; continuity can be assumed. Basis for Probable Reserves.

Why it applies: category is "indicated"

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

No QP/CP Disclosurenegative

No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

Resource Updateneutral

Revised estimate for an existing resource — compare to prior to assess progress.

Why it applies: the release compares against a previous estimate

PEA-Supportingneutral

Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

inferredAdina · lithiumTonnes: 15900000Grade: 1.17Grade Unit: %Contained Metal: 186000Contained Unit: tView all details
Link to this fact

Identity

Project
Adina
Commodity
lithium
Region
canada_qc
Reported Region
Quebec
Ticker
LIFT

Resource scope

Estimate type
resource
Resource group id
resource:378e07dc5aa5e90d160c

Resource Data

Category
inferred
Tonnes
15900000
Grade
1.17
Grade Unit
%
Contained Metal
186000
Contained Unit
t

Prior Estimate

Resource Date
2026-05-07

Review

Needs Review
No
Historical
No

Dates

Event date
2026-11-17T00:00:00.000Z

Reasoning: Significant inferred resource component.

Positive factors

  • Substantial inferred resource

Negative factors

  • Inferred category

Evidence · text

“15.9 million inferred tonnes at 1.17%, containing about 186,000 tonnes”

Tags used in scoring

Inferred Resourcenegative

Speculative category — limited drilling, geological continuity assumed but not confirmed. Cannot support economic studies alone.

Why it applies: category is "inferred"

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

No QP/CP Disclosurenegative

No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

Resource Updateneutral

Revised estimate for an existing resource — compare to prior to assess progress.

Why it applies: the release compares against a previous estimate

PEA-Supportingneutral

Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.