KOB: Koba Commences Drilling to Test Tin-Tungsten Targets
Original announcement by asx on
- Company
- Koba Resources Limited
- Ticker
- KOB
- Exchange
- ASX
- Region
- North Queensland
- Primary commodity
- Unavailable
- Secondary commodities
- None reported
- Document categories
- Other, Drill results
- Extracted
- 2026-10-28 22:19:19 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Koba Resources has commenced a 3,000m drilling program across three prospects in North Queensland: the Kitchener Trend, the Jiminy Prospect, and the Gilmore Tin Mine. The program aims to test new targets at Stannary Hills and follow up on recent high-grade tin intersections at the Mt Garnet Tin-Tungsten Project.
Reasoning: The company has commenced a 3,000m drilling program targeting high-priority tin-tungsten prospects, including maiden drilling at Jiminy and follow-up at Gilmore.
Positive factors
- commencement of drilling at high-priority targets
- maiden drilling at Jiminy Prospect
- follow-up drilling at high-grade Gilmore Tin Mine
Facts used in scoring: 12

Classification and evidence
Infill Drillingneutral · Story-specific tag
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: The program includes follow-up drilling at the Gilmore Tin Mine to target extensions of previously intersected mineralisation.
Evidence · text
“undertake its initial follow-up drilling to target extensions of the thick, high-grade tin mineralisation intersected in hole MGRC011”
Step-Out Extensionpositive · Story-specific tag
Mineralization extended beyond the previously known limit.
Why it applies: The program includes maiden drilling at the Jiminy Prospect and testing for extensions at the Gilmore Tin Mine.
Evidence · text
“commences testing for mineralisation beneath the extensive surface anomalies”
Extracted facts
Stored fact records: 12. Some facts used in scoring do not have a stored record.
Drill Results (12)
MGRC011Mt Garnet · tinGrade: 1.2Grade Unit: %Intercept: 29 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MGRC011
- Project
- Mt Garnet
- Commodity
- tin
- Region
- australia_qld
- Reported Region
- australia_qld
- Ticker
- KOB
Geometry
- Grade
- 1.2
- Grade Unit
- %
- Intercept
- 29 m
- From
- 111 m
- To
- 140 m
- Intercept Depth
- 111 m
Classification
- Sample Type
- drill
- Group ID
- MGRC011:111-140
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-10-14T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: High-grade tin intercept reported in a recent announcement (Oct 2026).
Positive factors
- thick high-grade intersection
Evidence · text
“29m @ 1.2% Sn”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MGRC011Mt Garnet · copperGrade: 0.36Grade Unit: %Intercept: 29 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MGRC011
- Project
- Mt Garnet
- Commodity
- copper
- Region
- australia_qld
- Reported Region
- australia_qld
- Ticker
- KOB
Geometry
- Grade
- 0.36
- Grade Unit
- %
- Intercept
- 29 m
- From
- 111 m
- To
- 140 m
- Intercept Depth
- 111 m
Classification
- Sample Type
- drill
- Group ID
- MGRC011:111-140
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-10-14T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Copper byproduct grade in a recent high-grade tin intercept.
Evidence · text
“0.36% Cu”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MGRC011Mt Garnet · tungstenGrade: 0.017Grade Unit: %Intercept: 29 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MGRC011
- Project
- Mt Garnet
- Commodity
- tungsten
- Region
- australia_qld
- Reported Region
- australia_qld
- Ticker
- KOB
Geometry
- Grade
- 0.017
- Grade Unit
- %
- Intercept
- 29 m
- From
- 111 m
- To
- 140 m
- Intercept Depth
- 111 m
Classification
- Sample Type
- drill
- Group ID
- MGRC011:111-140
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-10-14T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Trace tungsten grade in a recent high-grade tin intercept.
Evidence · text
“0.017% WO3”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MGRC011Mt Garnet · silverGrade: 22Grade Unit: g/tIntercept: 29 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MGRC011
- Project
- Mt Garnet
- Commodity
- silver
- Region
- australia_qld
- Reported Region
- australia_qld
- Ticker
- KOB
Geometry
- Grade
- 22
- Grade Unit
- g/t
- Intercept
- 29 m
- From
- 111 m
- To
- 140 m
- Intercept Depth
- 111 m
Classification
- Sample Type
- drill
- Group ID
- MGRC011:111-140
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-10-14T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Silver byproduct grade in a recent high-grade tin intercept.
Evidence · text
“22 g/t Ag”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MGRC011Mt Garnet · tinGrade: 2Grade Unit: %Intercept: 15 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MGRC011
- Project
- Mt Garnet
- Commodity
- tin
- Region
- australia_qld
- Reported Region
- australia_qld
- Ticker
- KOB
Geometry
- Grade
- 2
- Grade Unit
- %
- Intercept
- 15 m
- From
- 117 m
- To
- 132 m
- Intercept Depth
- 117 m
Classification
- Sample Type
- drill
- Group ID
- MGRC011:117-132
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-10-14T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: High-grade sub-interval within the 29m intercept.
Positive factors
- high-grade sub-interval
Evidence · text
“15m @ 2.0% Sn”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MGRC011Mt Garnet · copperGrade: 0.58Grade Unit: %Intercept: 15 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MGRC011
- Project
- Mt Garnet
- Commodity
- copper
- Region
- australia_qld
- Reported Region
- australia_qld
- Ticker
- KOB
Geometry
- Grade
- 0.58
- Grade Unit
- %
- Intercept
- 15 m
- From
- 117 m
- To
- 132 m
- Intercept Depth
- 117 m
Classification
- Sample Type
- drill
- Group ID
- MGRC011:117-132
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-10-14T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Copper byproduct grade in a high-grade sub-interval.
Evidence · text
“0.58% Cu”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MGRC011Mt Garnet · tungstenGrade: 0.02Grade Unit: %Intercept: 15 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MGRC011
- Project
- Mt Garnet
- Commodity
- tungsten
- Region
- australia_qld
- Reported Region
- australia_qld
- Ticker
- KOB
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 15 m
- From
- 117 m
- To
- 132 m
- Intercept Depth
- 117 m
Classification
- Sample Type
- drill
- Group ID
- MGRC011:117-132
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-10-14T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Trace tungsten grade in a high-grade sub-interval.
Evidence · text
“0.020% WO3”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MGRC011Mt Garnet · silverGrade: 33Grade Unit: g/tIntercept: 15 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MGRC011
- Project
- Mt Garnet
- Commodity
- silver
- Region
- australia_qld
- Reported Region
- australia_qld
- Ticker
- KOB
Geometry
- Grade
- 33
- Grade Unit
- g/t
- Intercept
- 15 m
- From
- 117 m
- To
- 132 m
- Intercept Depth
- 117 m
Classification
- Sample Type
- drill
- Group ID
- MGRC011:117-132
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-10-14T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Silver byproduct grade in a high-grade sub-interval.
Evidence · text
“33 g/t Ag”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MGRC011Mt Garnet · tinGrade: 6.3Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MGRC011
- Project
- Mt Garnet
- Commodity
- tin
- Region
- australia_qld
- Reported Region
- australia_qld
- Ticker
- KOB
Geometry
- Grade
- 6.3
- Grade Unit
- %
- Intercept
- 2 m
- From
- 126 m
- To
- 128 m
- Intercept Depth
- 126 m
Classification
- Sample Type
- drill
- Group ID
- MGRC011:126-128
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-10-14T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Very high grade sub-interval (6.3% Sn).
Positive factors
- bonanza grade sub-interval
Evidence · text
“2m @ 6.3% Sn”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MGRC011Mt Garnet · copperGrade: 0.44Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MGRC011
- Project
- Mt Garnet
- Commodity
- copper
- Region
- australia_qld
- Reported Region
- australia_qld
- Ticker
- KOB
Geometry
- Grade
- 0.44
- Grade Unit
- %
- Intercept
- 2 m
- From
- 126 m
- To
- 128 m
- Intercept Depth
- 126 m
Classification
- Sample Type
- drill
- Group ID
- MGRC011:126-128
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-10-14T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Copper byproduct grade in a high-grade sub-interval.
Evidence · text
“0.44% Cu”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MGRC011Mt Garnet · tungstenGrade: 0.017Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MGRC011
- Project
- Mt Garnet
- Commodity
- tungsten
- Region
- australia_qld
- Reported Region
- australia_qld
- Ticker
- KOB
Geometry
- Grade
- 0.017
- Grade Unit
- %
- Intercept
- 2 m
- From
- 126 m
- To
- 128 m
- Intercept Depth
- 126 m
Classification
- Sample Type
- drill
- Group ID
- MGRC011:126-128
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-10-14T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Trace tungsten grade in a high-grade sub-interval.
Evidence · text
“0.017% WO3”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MGRC011Mt Garnet · silverGrade: 26Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MGRC011
- Project
- Mt Garnet
- Commodity
- silver
- Region
- australia_qld
- Reported Region
- australia_qld
- Ticker
- KOB
Geometry
- Grade
- 26
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 126 m
- To
- 128 m
- Intercept Depth
- 126 m
Classification
- Sample Type
- drill
- Group ID
- MGRC011:126-128
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-10-14T00:00:00.000Z
Dates
- Event date
- 2026-10-28T00:00:00.000Z
Reasoning: Silver byproduct grade in a high-grade sub-interval.
Evidence · text
“26 g/t Ag”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.