IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Including 92.97 m of 0.39% Cu (0.67% CuEq) at Kismet, Freeze Project, Idaho USA
Original announcement by jmn on
- Company
- IDEX Metals Corp.
- Ticker
- IDEX
- Exchange
- TSXV
- Region
- Idaho, USA
- Primary commodity
- Copper
- Secondary commodities
- Molybdenum, Silver, Tungsten
- Document categories
- Drill results, Other
- Extracted
- 2026-11-12 12:43:40 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
IDEX Metals has reported 2026 drill assays from the Kismet target, including a 92.97 m copper intercept at 0.39% Cu, demonstrating mineralization extension at depth. Additionally, the company reported visual evidence of a magmatic-hydrothermal system at the newly drilled Shiver target, suggesting a continuous 3 km mineralized corridor.
Reasoning: The release reports significant copper intercepts at depth at Kismet and visual evidence of a magmatic-hydrothermal system at the new Shiver target, extending the known mineralized corridor.
Positive factors
- extension of higher-grade copper at depth
- evidence of magmatic-hydrothermal system at new Shiver target
- mineralized corridor spanning nearly 3 km
- potassic alteration observed at depth
Negative factors
- assays pending for several holes
- visual observations at Shiver are not yet assay-validated
Facts used in scoring: 8

Classification and evidence
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release mentions AGAT Laboratories (ISO 17025 accredited) and specific QA/QC methods including blanks, standards, and duplicates.
Evidence · text
“Samples were shipped under chain of custody to AGAT Laboratories in Calgary, Alberta, an ISO 17025 accredited laboratory”
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: KSMT26012 demonstrates extension of higher-grade copper at Kismet to depth.
Evidence · text
“demonstrating an extension of higher-grade copper at Kismet to depth”
Extracted facts
Stored fact records: 8. Some facts used in scoring do not have a stored record.
Drill Results (8)
KSMT26012Freeze · copperGrade: 0.39Grade Unit: %Intercept: 92.97 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX
Geometry
- Grade
- 0.39
- Grade Unit
- %
- Intercept
- 92.97 m
- From
- 247.05 m
- To
- 340.02 m
- Intercept Depth
- 247.05 m
Classification
- Sample Type
- drill
- Group ID
- KSMT26012:247.05-340.02
- Mining Method
- unknown
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 0.67
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: Significant copper intercept at depth in a potassic-altered breccia.
Positive factors
- demonstrates extension of higher-grade copper at depth
Evidence · text
“92.97 m of 0.39% copper, 308 ppm molybdenum and 2.04 g/t silver, or 0.67% copper equivalent”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "
KSMT26012Freeze · molybdenumGrade: 308Grade Unit: ppmIntercept: 92.97 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- molybdenum
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX
Geometry
- Grade
- 308
- Grade Unit
- ppm
- Intercept
- 92.97 m
- From
- 247.05 m
- To
- 340.02 m
- Intercept Depth
- 247.05 m
Classification
- Sample Type
- drill
- Group ID
- KSMT26012:247.05-340.02
- Mining Method
- unknown
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: Molybdenum reported as part of a polymetallic intercept.
Evidence · text
“308 ppm molybdenum”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "
KSMT26012Freeze · silverGrade: 2.04Grade Unit: g/tIntercept: 92.97 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX
Geometry
- Grade
- 2.04
- Grade Unit
- g/t
- Intercept
- 92.97 m
- From
- 247.05 m
- To
- 340.02 m
- Intercept Depth
- 247.05 m
Classification
- Sample Type
- drill
- Group ID
- KSMT26012:247.05-340.02
- Mining Method
- unknown
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: Silver reported as part of a polymetallic intercept.
Evidence · text
“2.04 g/t silver”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "
KSMT26012Freeze · copperGrade: 0.96Grade Unit: %Intercept: 25.4 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX
Geometry
- Grade
- 0.96
- Grade Unit
- %
- Intercept
- 25.4 m
Classification
- Sample Type
- drill
- Group ID
- KSMT26012:sub-interval
- Mining Method
- unknown
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.38
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: Strong high-grade sub-interval within the main intercept.
Positive factors
- high-grade copper in potassic-altered breccia
Evidence · text
“25.40 m of 0.96% Cu (1.38% CuEq)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "
KSMT26012Freeze · copperGrade: 1.5Grade Unit: %Intercept: 6.97 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX
Geometry
- Grade
- 1.5
- Grade Unit
- %
- Intercept
- 6.97 m
Classification
- Sample Type
- drill
- Group ID
- KSMT26012:sub-sub-interval
- Mining Method
- unknown
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: High-grade core within the high-grade sub-interval.
Positive factors
- very high grade intercept
Evidence · text
“6.97 m of 1.50% Cu, 430 ppm Mo and 11.04 g/t Ag (2.00% CuEq)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "
KSMT26010Freeze · copperGrade: 0.23Grade Unit: %Intercept: 129.08 mView all detailsHide details
Identity
- Hole ID
- KSMT26010
- Project
- Freeze
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX
Geometry
- Grade
- 0.23
- Grade Unit
- %
- Intercept
- 129.08 m
- From
- 101 m
- To
- 229.08 m
- Intercept Depth
- 101 m
Classification
- Sample Type
- drill
- Group ID
- KSMT26010:101-229.08
- Mining Method
- unknown
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 0.28
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: Broad, lower-grade copper intercept.
Positive factors
- broad intercept
Evidence · text
“129.08 m of 0.23% Cu (0.28% CuEq) from 101.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "
KSMT26010Freeze · tungstenGrade: 1322Grade Unit: ppmIntercept: 16 mView all detailsHide details
Identity
- Hole ID
- KSMT26010
- Project
- Freeze
- Commodity
- tungsten
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX
Geometry
- Grade
- 1322
- Grade Unit
- ppm
- Intercept
- 16 m
- From
- 212 m
- To
- 228 m
- Intercept Depth
- 212 m
Classification
- Sample Type
- drill
- Group ID
- KSMT26010:212-228
- Mining Method
- unknown
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: Strong tungsten intercept reported in the 2026 program.
Positive factors
- high-grade tungsten intercept
Evidence · text
“16.00 m of 1,322 ppm W (0.17% WO3) from 212.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "
KSMT26010Freeze · tungstenGrade: 3104Grade Unit: ppmIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- KSMT26010
- Project
- Freeze
- Commodity
- tungsten
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX
Geometry
- Grade
- 3104
- Grade Unit
- ppm
- Intercept
- 5 m
- From
- 223 m
- To
- 228 m
- Intercept Depth
- 223 m
Classification
- Sample Type
- drill
- Group ID
- KSMT26010:223-228
- Mining Method
- unknown
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: Very high grade tungsten sub-interval.
Positive factors
- bonanza-style tungsten grade
Evidence · text
“5.00 m of 3,104 ppm W (0.39% WO3) from 223.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.