IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Including 92.97 m of 0.39% Cu (0.67% CuEq) at Kismet, Freeze Project, Idaho USA

Original announcement by jmn on

Company
IDEX Metals Corp.
Ticker
IDEX
Exchange
TSXV
Region
Idaho, USA
Primary commodity
Copper
Secondary commodities
Molybdenum, Silver, Tungsten
Document categories
Drill results, Other
Extracted
2026-11-12 12:43:40 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

IDEX Metals has reported 2026 drill assays from the Kismet target, including a 92.97 m copper intercept at 0.39% Cu, demonstrating mineralization extension at depth. Additionally, the company reported visual evidence of a magmatic-hydrothermal system at the newly drilled Shiver target, suggesting a continuous 3 km mineralized corridor.

Reasoning: The release reports significant copper intercepts at depth at Kismet and visual evidence of a magmatic-hydrothermal system at the new Shiver target, extending the known mineralized corridor.

Positive factors

  • extension of higher-grade copper at depth
  • evidence of magmatic-hydrothermal system at new Shiver target
  • mineralized corridor spanning nearly 3 km
  • potassic alteration observed at depth

Negative factors

  • assays pending for several holes
  • visual observations at Shiver are not yet assay-validated

Facts used in scoring: 8

Atlas analysis — IDEX Metals Corp.: IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Including 92.97 m of 0.39% Cu (0.67% CuEq) at Kismet, Freeze Project, Idaho USA. 0.39 % over 92.97 m; 0.23 % over 129.08 m; 0.96 % over 25.4 m

Classification and evidence

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release mentions AGAT Laboratories (ISO 17025 accredited) and specific QA/QC methods including blanks, standards, and duplicates.

Evidence · text

“Samples were shipped under chain of custody to AGAT Laboratories in Calgary, Alberta, an ISO 17025 accredited laboratory”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: KSMT26012 demonstrates extension of higher-grade copper at Kismet to depth.

Evidence · text

“demonstrating an extension of higher-grade copper at Kismet to depth”

Extracted facts

Stored fact records: 8. Some facts used in scoring do not have a stored record.

Drill Results (8)

KSMT26012Freeze · copperGrade: 0.39Grade Unit: %Intercept: 92.97 mView all details
Link to this fact

Identity

Hole ID
KSMT26012
Project
Freeze
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
IDEX

Geometry

Grade
0.39
Grade Unit
%
Intercept
92.97 m
From
247.05 m
To
340.02 m
Intercept Depth
247.05 m

Classification

Sample Type
drill
Group ID
KSMT26012:247.05-340.02
Mining Method
unknown

Location

Location
Kismet
CRS
NAD83 UTM Zone 11N
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.67
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-12T00:00:00.000Z

Reasoning: Significant copper intercept at depth in a potassic-altered breccia.

Positive factors

  • demonstrates extension of higher-grade copper at depth

Evidence · text

“92.97 m of 0.39% copper, 308 ppm molybdenum and 2.04 g/t silver, or 0.67% copper equivalent”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "

KSMT26012Freeze · molybdenumGrade: 308Grade Unit: ppmIntercept: 92.97 mView all details
Link to this fact

Identity

Hole ID
KSMT26012
Project
Freeze
Commodity
molybdenum
Region
usa_id
Reported Region
usa_id
Ticker
IDEX

Geometry

Grade
308
Grade Unit
ppm
Intercept
92.97 m
From
247.05 m
To
340.02 m
Intercept Depth
247.05 m

Classification

Sample Type
drill
Group ID
KSMT26012:247.05-340.02
Mining Method
unknown

Location

Location
Kismet
CRS
NAD83 UTM Zone 11N
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-12T00:00:00.000Z

Reasoning: Molybdenum reported as part of a polymetallic intercept.

Evidence · text

“308 ppm molybdenum”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "

KSMT26012Freeze · silverGrade: 2.04Grade Unit: g/tIntercept: 92.97 mView all details
Link to this fact

Identity

Hole ID
KSMT26012
Project
Freeze
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
IDEX

Geometry

Grade
2.04
Grade Unit
g/t
Intercept
92.97 m
From
247.05 m
To
340.02 m
Intercept Depth
247.05 m

Classification

Sample Type
drill
Group ID
KSMT26012:247.05-340.02
Mining Method
unknown

Location

Location
Kismet
CRS
NAD83 UTM Zone 11N
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-12T00:00:00.000Z

Reasoning: Silver reported as part of a polymetallic intercept.

Evidence · text

“2.04 g/t silver”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "

KSMT26012Freeze · copperGrade: 0.96Grade Unit: %Intercept: 25.4 mView all details
Link to this fact

Identity

Hole ID
KSMT26012
Project
Freeze
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
IDEX

Geometry

Grade
0.96
Grade Unit
%
Intercept
25.4 m

Classification

Sample Type
drill
Group ID
KSMT26012:sub-interval
Mining Method
unknown

Location

Location
Kismet
CRS
NAD83 UTM Zone 11N
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.38
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-12T00:00:00.000Z

Reasoning: Strong high-grade sub-interval within the main intercept.

Positive factors

  • high-grade copper in potassic-altered breccia

Evidence · text

“25.40 m of 0.96% Cu (1.38% CuEq)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "

KSMT26012Freeze · copperGrade: 1.5Grade Unit: %Intercept: 6.97 mView all details
Link to this fact

Identity

Hole ID
KSMT26012
Project
Freeze
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
IDEX

Geometry

Grade
1.5
Grade Unit
%
Intercept
6.97 m

Classification

Sample Type
drill
Group ID
KSMT26012:sub-sub-interval
Mining Method
unknown

Location

Location
Kismet
CRS
NAD83 UTM Zone 11N
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-12T00:00:00.000Z

Reasoning: High-grade core within the high-grade sub-interval.

Positive factors

  • very high grade intercept

Evidence · text

“6.97 m of 1.50% Cu, 430 ppm Mo and 11.04 g/t Ag (2.00% CuEq)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "

KSMT26010Freeze · copperGrade: 0.23Grade Unit: %Intercept: 129.08 mView all details
Link to this fact

Identity

Hole ID
KSMT26010
Project
Freeze
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
IDEX

Geometry

Grade
0.23
Grade Unit
%
Intercept
129.08 m
From
101 m
To
229.08 m
Intercept Depth
101 m

Classification

Sample Type
drill
Group ID
KSMT26010:101-229.08
Mining Method
unknown

Location

Location
Kismet
CRS
NAD83 UTM Zone 11N
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.28
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-12T00:00:00.000Z

Reasoning: Broad, lower-grade copper intercept.

Positive factors

  • broad intercept

Evidence · text

“129.08 m of 0.23% Cu (0.28% CuEq) from 101.00 m”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "

KSMT26010Freeze · tungstenGrade: 1322Grade Unit: ppmIntercept: 16 mView all details
Link to this fact

Identity

Hole ID
KSMT26010
Project
Freeze
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
IDEX

Geometry

Grade
1322
Grade Unit
ppm
Intercept
16 m
From
212 m
To
228 m
Intercept Depth
212 m

Classification

Sample Type
drill
Group ID
KSMT26010:212-228
Mining Method
unknown

Location

Location
Kismet
CRS
NAD83 UTM Zone 11N
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-12T00:00:00.000Z

Reasoning: Strong tungsten intercept reported in the 2026 program.

Positive factors

  • high-grade tungsten intercept

Evidence · text

“16.00 m of 1,322 ppm W (0.17% WO3) from 212.00 m”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "

KSMT26010Freeze · tungstenGrade: 3104Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
KSMT26010
Project
Freeze
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
IDEX

Geometry

Grade
3104
Grade Unit
ppm
Intercept
5 m
From
223 m
To
228 m
Intercept Depth
223 m

Classification

Sample Type
drill
Group ID
KSMT26010:223-228
Mining Method
unknown

Location

Location
Kismet
CRS
NAD83 UTM Zone 11N
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-12T00:00:00.000Z

Reasoning: Very high grade tungsten sub-interval.

Positive factors

  • bonanza-style tungsten grade

Evidence · text

“5.00 m of 3,104 ppm W (0.39% WO3) from 223.00 m”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "IDEX Metals Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, "

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.