IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Including 92.97 m of 0.39% Cu (0.67% CuEq) at Kismet, Freeze Project, Idaho USA
Original announcement by orestocks on
- Company
- IDEX Metals Corp.
- Ticker
- IDEX.V
- Exchange
- Unavailable
- Region
- Idaho
- Primary commodity
- Unavailable
- Secondary commodities
- None reported
- Document categories
- Drill results
- Extracted
- 2026-11-12 12:27:57 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
IDEX Metals reported initial 2026 drill assays from its Freeze Project in Idaho, highlighted by hole KSMT26012 at Kismet intersecting 92.97 m of 0.39% copper (0.67% CuEq), including a higher-grade zone of 25.40 m at 0.96% copper (1.38% CuEq) that extends mineralization to depth. The company also announced evidence of a magmatic-hydrothermal system at the new Shiver target, which, along with Kismet and Solstice, defines a nearly 3 km long mineralized corridor. Assays are pending for several other holes, including the Solstice discovery hole and the new Shiver intersection.
Reasoning: IDEX Metals reported strong initial 2026 drill results from the Kismet target, including a significant copper intercept that extends mineralization to depth. The company also identified a large 3 km mineralized corridor with evidence of a magmatic-hydrothermal system at a new target, Shiver, significantly expanding the project's exploration potential.
Positive factors
- High-grade copper intercept of 92.97 m at 0.39% Cu (0.67% CuEq) including 25.40 m at 0.96% Cu (1.38% CuEq) at Kismet.
- Extension of higher-grade copper mineralization to depth (220-300 m below surface) at Kismet.
- Discovery of a nearly 3 km long mineralized corridor linking Kismet, Solstice, and the new Shiver target.
- Evidence of a magmatic-hydrothermal system at the new Shiver target, indicating significant exploration potential.
- Significant tungsten intercepts, including 16.00 m of 1,322 ppm W (0.17% WO3) at Kismet.
- Potassic alteration associated with deeper copper mineralization at Kismet.
Negative factors
- True widths of reported intercepts are not yet known.
- Copper equivalent (CuEq) calculations assume 100% metallurgical recoveries, which have not been tested.
- Observations at Shiver and Solstice are preliminary visual logs, and assays are pending.
Facts used in scoring: 29

Classification and evidence
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: The document explicitly states that 'true widths are not yet known' for all reported intercepts.
Evidence · text
“Intervals are core lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release details QA/QC procedures including the use of certified reference materials, blanks, and field/pulp duplicates, and mentions AGAT Laboratories is an ISO 17025 accredited laboratory, with sign-off by a Qualified Person.
Evidence · text
“The Company's QA/QC program includes the insertion of certified reference materials, blanks and field and pulp duplicates into the sample stream, in addition to the laboratory's internal quality control. ... AGAT Laboratories in Calgary, Alberta, an ISO 17025 accredited laboratory ... David Hladky, P.Geo. ... is a "Qualified Person"”
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used.
Why it applies: The metal equivalent (CuEq) calculation assumes 100% metallurgical recoveries for all metals, which is explicitly stated as not having been tested.
Evidence · text
“Metallurgical recoveries of 100% are assumed to be equal for all metals; no metallurgical testwork has been completed on the Freeze Property.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: The cut-off grade for copper intercepts is stated as 0.10% Cu, and for tungsten as 100 ppm W.
Evidence · text
“Significant intercepts were calculated using a 0.10% Cu cut-off ... Intercepts were calculated using a 100 ppm W cut-off.”
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: The company is testing new targets like Shiver and extending mineralization at Kismet to depth, and planning follow-up drilling at Solstice and Shiver and first tests of the gaps between them.
Evidence · text
“KSMT26020, the first drill hole at the Shiver Target ... demonstrating an extension of higher-grade copper at Kismet to depth ... The Company is planning follow-up drilling at Shiver and Solstice and first tests of the untested ground between Kismet, Solstice and Shiver.”
Extracted facts
Stored fact records: 29. Some facts used in scoring do not have a stored record.
Drill Results (29)
KSMT26012Freeze · copperGrade: 0.37Grade Unit: %Intercept: 18 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 0.37
- Grade Unit
- %
- Intercept
- 18 m
- From
- 105 m
- To
- 123 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 105 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:105-123
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.42
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This is a moderate copper intercept from a shallower zone in KSMT26012, contributing to the overall mineralization profile at Kismet.
Positive factors
- Moderate copper grade for a porphyry deposit.
- Part of initial 2026 drill program.
Negative factors
- True width not known.
Evidence · text
“18.00 m of 0.37% Cu, 31 ppm Mo and 1.71 g/t Ag (0.42% CuEq) from 105.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · molybdenumGrade: 31Grade Unit: ppmIntercept: 18 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- molybdenum
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 31
- Grade Unit
- ppm
- Intercept
- 18 m
- From
- 105 m
- To
- 123 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 105 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:105-123
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This molybdenum intercept is low grade but contributes to the polymetallic nature of the mineralization.
Positive factors
- Molybdenum present as a byproduct.
Negative factors
- Low molybdenum grade.
Evidence · text
“18.00 m of 0.37% Cu, 31 ppm Mo and 1.71 g/t Ag (0.42% CuEq) from 105.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · silverGrade: 1.71Grade Unit: g/tIntercept: 18 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 1.71
- Grade Unit
- g/t
- Intercept
- 18 m
- From
- 105 m
- To
- 123 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 105 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:105-123
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This silver intercept is low grade but contributes to the polymetallic nature of the mineralization.
Positive factors
- Silver present as a byproduct.
Negative factors
- Low silver grade.
Evidence · text
“18.00 m of 0.37% Cu, 31 ppm Mo and 1.71 g/t Ag (0.42% CuEq) from 105.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · copperGrade: 0.39Grade Unit: %Intercept: 92.97 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 0.39
- Grade Unit
- %
- Intercept
- 92.97 m
- From
- 247.05 m
- To
- 340.02 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 247.05 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:247.05-340.02
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.67
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This is a highly material and novel copper intercept, representing the best grades of the 2026 program and extending mineralization to depth within a favorable geological setting.
Positive factors
- Strong copper grade and exceptional width for a porphyry deposit (GT = 36.26).
- Extends mineralization to depth (247.05 m downhole).
- Best copper grades of the 2026 program to date.
- Hosted in potassic-altered breccia, indicating a robust system.
Negative factors
- True width not known.
Evidence · text
“92.97 m of 0.39% Cu, 308 ppm Mo and 2.04 g/t Ag (0.67% CuEq) from 247.05 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · molybdenumGrade: 308Grade Unit: ppmIntercept: 92.97 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- molybdenum
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 308
- Grade Unit
- ppm
- Intercept
- 92.97 m
- From
- 247.05 m
- To
- 340.02 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 247.05 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:247.05-340.02
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This molybdenum intercept is a good byproduct credit within a significant copper zone, enhancing the overall value of the mineralization.
Positive factors
- Moderate molybdenum grade over a significant width.
- Contributes to the polymetallic nature of the intercept.
Evidence · text
“92.97 m of 0.39% Cu, 308 ppm Mo and 2.04 g/t Ag (0.67% CuEq) from 247.05 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · silverGrade: 2.04Grade Unit: g/tIntercept: 92.97 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 2.04
- Grade Unit
- g/t
- Intercept
- 92.97 m
- From
- 247.05 m
- To
- 340.02 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 247.05 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:247.05-340.02
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This silver intercept provides a byproduct credit within a significant copper zone, contributing to the overall polymetallic value.
Positive factors
- Silver present as a byproduct over a significant width.
Evidence · text
“92.97 m of 0.39% Cu, 308 ppm Mo and 2.04 g/t Ag (0.67% CuEq) from 247.05 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · copperGrade: 0.96Grade Unit: %Intercept: 25.4 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 0.96
- Grade Unit
- %
- Intercept
- 25.4 m
- From
- 247.05 m
- To
- 272.45 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 247.05 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:247.05-272.45
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.38
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This high-grade sub-interval significantly enhances the overall intercept, demonstrating strong copper mineralization at depth within a favorable geological setting.
Positive factors
- Exceptional copper grade and strong width for a porphyry deposit (GT = 24.38).
- Extends higher-grade copper to depth (220-300 m below surface).
- Hosted in potassic-altered breccia, indicating a robust system.
Negative factors
- True width not known.
Evidence · text
“25.40 m of 0.96% Cu (1.38% CuEq)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · molybdenumGrade: 440Grade Unit: ppmIntercept: 25.4 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- molybdenum
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 440
- Grade Unit
- ppm
- Intercept
- 25.4 m
- From
- 247.05 m
- To
- 272.45 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 247.05 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:247.05-272.45
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This molybdenum intercept provides a significant byproduct credit within the high-grade copper zone, contributing positively to the overall economics.
Positive factors
- Strong molybdenum grade over a good width.
- Enhances the polymetallic value of the high-grade copper zone.
Evidence · text
“25.40 m of 0.96% Cu, 440 ppm Mo and 5.49 g/t Ag (1.38% CuEq)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · silverGrade: 5.49Grade Unit: g/tIntercept: 25.4 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 5.49
- Grade Unit
- g/t
- Intercept
- 25.4 m
- From
- 247.05 m
- To
- 272.45 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 247.05 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:247.05-272.45
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This silver intercept provides a good byproduct credit within the high-grade copper zone, contributing to the overall polymetallic value.
Positive factors
- Moderate silver grade over a good width.
- Provides byproduct credit within the high-grade copper zone.
Evidence · text
“25.40 m of 0.96% Cu, 440 ppm Mo and 5.49 g/t Ag (1.38% CuEq)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · copperGrade: 1.5Grade Unit: %Intercept: 6.97 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 1.5
- Grade Unit
- %
- Intercept
- 6.97 m
- From
- 247.05 m
- To
- 254.02 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 247.05 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:247.05-254.02
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 2
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This bonanza-grade sub-interval is extremely material, representing the highest copper grades and further confirming the presence of very high-grade mineralization at depth.
Positive factors
- Bonanza copper grade and moderate width for a porphyry deposit (GT = 10.46).
- Highest-grade copper interval reported in this release.
- Extends bonanza-grade copper to depth.
- Hosted in potassic-altered breccia, indicating a robust system.
Negative factors
- True width not known.
Evidence · text
“6.97 m of 1.50% Cu, 430 ppm Mo and 11.04 g/t Ag (2.00% CuEq)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · molybdenumGrade: 430Grade Unit: ppmIntercept: 6.97 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- molybdenum
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 430
- Grade Unit
- ppm
- Intercept
- 6.97 m
- From
- 247.05 m
- To
- 254.02 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 247.05 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:247.05-254.02
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This molybdenum intercept provides a strong byproduct credit within the bonanza-grade copper zone, enhancing the overall economics.
Positive factors
- Strong molybdenum grade within a bonanza-grade copper zone.
Evidence · text
“6.97 m of 1.50% Cu, 430 ppm Mo and 11.04 g/t Ag (2.00% CuEq)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · silverGrade: 11.04Grade Unit: g/tIntercept: 6.97 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 11.04
- Grade Unit
- g/t
- Intercept
- 6.97 m
- From
- 247.05 m
- To
- 254.02 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 247.05 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:247.05-254.02
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This silver intercept provides a strong byproduct credit within the bonanza-grade copper zone, contributing significantly to the overall polymetallic value.
Positive factors
- Strong silver grade within a bonanza-grade copper zone.
Evidence · text
“6.97 m of 1.50% Cu, 430 ppm Mo and 11.04 g/t Ag (2.00% CuEq)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · tungstenGrade: 526Grade Unit: ppmIntercept: 50.27 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- tungsten
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 526
- Grade Unit
- ppm
- Intercept
- 50.27 m
- From
- 255.73 m
- To
- 306 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 255.73 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:255.73-306
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 100
- Cutoff Unit
- ppm W
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This tungsten intercept provides a good byproduct credit over a substantial width, enhancing the overall polymetallic nature of the mineralization at Kismet.
Positive factors
- Moderate tungsten grade over a significant width.
- Overlaps with the main copper interval, indicating polymetallic potential.
Evidence · text
“50.27 m of 526 ppm W (0.066% WO3) from 255.73 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · tungstenGrade: 2044Grade Unit: ppmIntercept: 3.72 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- tungsten
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 2044
- Grade Unit
- ppm
- Intercept
- 3.72 m
- From
- 259.28 m
- To
- 263 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 259.28 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:259.28-263
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 100
- Cutoff Unit
- ppm W
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This high-grade tungsten intercept significantly enhances the polymetallic value of the highest-grade copper zone, indicating a valuable byproduct.
Positive factors
- Strong tungsten grade over a narrow width.
- Coincides with the highest-grade copper in the hole, indicating high-value polymetallic mineralization.
Evidence · text
“3.72 m of 2,044 ppm W (0.26% WO3) from 259.28 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26012Freeze · molybdenumGrade: 225Grade Unit: ppmIntercept: 95.46 mView all detailsHide details
Identity
- Hole ID
- KSMT26012
- Project
- Freeze
- Commodity
- molybdenum
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 225
- Grade Unit
- ppm
- Intercept
- 95.46 m
- From
- 307.54 m
- To
- 403 m
- Hole Depth
- 502.62 m
- Intercept Depth
- 307.54 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26012:307.54-403
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 105 °
- Dip
- -64 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This broad molybdenum intercept indicates persistent mineralization at depth, suggesting a larger mineralized system.
Positive factors
- Moderate molybdenum grade over an exceptional width.
- Indicates continued mineralization below the main copper zone.
Evidence · text
“molybdenum remains elevated, averaging 225 ppm Mo over 95.46 m from 307.54 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26010Freeze · copperGrade: 0.23Grade Unit: %Intercept: 129.08 mView all detailsHide details
Identity
- Hole ID
- KSMT26010
- Project
- Freeze
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 0.23
- Grade Unit
- %
- Intercept
- 129.08 m
- From
- 101 m
- To
- 230.08 m
- Hole Depth
- 359.36 m
- Intercept Depth
- 101 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26010:101-230.08
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 50 °
- Dip
- -60 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.28
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This broad copper intercept demonstrates significant mineralization over a large interval, contributing positively to the overall resource potential at Kismet.
Positive factors
- Moderate copper grade over an exceptional width (GT = 29.69).
- Indicates broad mineralization at Kismet.
Negative factors
- True width not known.
Evidence · text
“129.08 m of 0.23% Cu (0.28% CuEq) from 101.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26010Freeze · copperGrade: 0.27Grade Unit: %Intercept: 68.08 mView all detailsHide details
Identity
- Hole ID
- KSMT26010
- Project
- Freeze
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 0.27
- Grade Unit
- %
- Intercept
- 68.08 m
- From
- 162 m
- To
- 230.08 m
- Hole Depth
- 359.36 m
- Intercept Depth
- 162 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26010:162-230.08
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 50 °
- Dip
- -60 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.37
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This sub-interval confirms broad copper mineralization with additional valuable byproducts, enhancing the overall prospectivity of Kismet.
Positive factors
- Moderate copper grade over a strong width (GT = 18.38).
- Includes molybdenum and tungsten, indicating polymetallic potential.
Negative factors
- True width not known.
Evidence · text
“68.08 m of 0.27% Cu, 104 ppm Mo and 406 ppm tungsten ("W") (0.37% CuEq) from 162.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26010Freeze · molybdenumGrade: 104Grade Unit: ppmIntercept: 68.08 mView all detailsHide details
Identity
- Hole ID
- KSMT26010
- Project
- Freeze
- Commodity
- molybdenum
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 104
- Grade Unit
- ppm
- Intercept
- 68.08 m
- From
- 162 m
- To
- 230.08 m
- Hole Depth
- 359.36 m
- Intercept Depth
- 162 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26010:162-230.08
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 50 °
- Dip
- -60 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This molybdenum intercept provides a byproduct credit within a significant copper zone, contributing to the polymetallic nature of the mineralization.
Positive factors
- Molybdenum present as a byproduct over a strong width.
Negative factors
- Low molybdenum grade.
Evidence · text
“68.08 m of 0.27% Cu, 104 ppm Mo and 406 ppm tungsten ("W") (0.37% CuEq) from 162.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26010Freeze · tungstenGrade: 406Grade Unit: ppmIntercept: 68.08 mView all detailsHide details
Identity
- Hole ID
- KSMT26010
- Project
- Freeze
- Commodity
- tungsten
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 406
- Grade Unit
- ppm
- Intercept
- 68.08 m
- From
- 162 m
- To
- 230.08 m
- Hole Depth
- 359.36 m
- Intercept Depth
- 162 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26010:162-230.08
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 50 °
- Dip
- -60 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This tungsten intercept provides a byproduct credit within a significant copper zone, contributing to the polymetallic nature of the mineralization.
Positive factors
- Tungsten present as a byproduct over a strong width.
Negative factors
- Low tungsten grade.
Evidence · text
“68.08 m of 0.27% Cu, 104 ppm Mo and 406 ppm tungsten ("W") (0.37% CuEq) from 162.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26010Freeze · tungstenGrade: 809Grade Unit: ppmIntercept: 29.51 mView all detailsHide details
Identity
- Hole ID
- KSMT26010
- Project
- Freeze
- Commodity
- tungsten
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 809
- Grade Unit
- ppm
- Intercept
- 29.51 m
- From
- 200.57 m
- To
- 230.08 m
- Hole Depth
- 359.36 m
- Intercept Depth
- 200.57 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26010:200.57-230.08
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 50 °
- Dip
- -60 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 100
- Cutoff Unit
- ppm W
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This significant tungsten intercept represents the highest grades of the program, indicating a valuable byproduct credit at Kismet.
Positive factors
- Strong tungsten grade over a good width.
- Highest tungsten grades of the 2026 program to date.
Evidence · text
“29.51 m of 809 ppm W (0.10% WO3) from 200.57 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26010Freeze · tungstenGrade: 1322Grade Unit: ppmIntercept: 16 mView all detailsHide details
Identity
- Hole ID
- KSMT26010
- Project
- Freeze
- Commodity
- tungsten
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 1322
- Grade Unit
- ppm
- Intercept
- 16 m
- From
- 212 m
- To
- 228 m
- Hole Depth
- 359.36 m
- Intercept Depth
- 212 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26010:212-228
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 50 °
- Dip
- -60 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 100
- Cutoff Unit
- ppm W
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This high-grade tungsten sub-interval further highlights the significant byproduct potential at Kismet.
Positive factors
- Strong tungsten grade over a moderate width.
- Part of the highest tungsten grades of the 2026 program.
Evidence · text
“16.00 m of 1,322 ppm W (0.17% WO3) from 212.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26010Freeze · tungstenGrade: 3104Grade Unit: ppmIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- KSMT26010
- Project
- Freeze
- Commodity
- tungsten
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 3104
- Grade Unit
- ppm
- Intercept
- 5 m
- From
- 223 m
- To
- 228 m
- Hole Depth
- 359.36 m
- Intercept Depth
- 223 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26010:223-228
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 50 °
- Dip
- -60 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 100
- Cutoff Unit
- ppm W
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This very high-grade tungsten sub-interval represents the best tungsten grade of the program, indicating significant byproduct value.
Positive factors
- Exceptional tungsten grade over a narrow width.
- Highest tungsten grade reported in this release.
Evidence · text
“5.00 m of 3,104 ppm W (0.39% WO3) from 223.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26010Freeze · tungstenGrade: 558Grade Unit: ppmIntercept: 31.99 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- KSMT26010
- Project
- Freeze
- Commodity
- tungsten
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 558
- Grade Unit
- ppm
- Intercept
- 31.99 m
- From
- 259 m
- To
- 290.99 m
- Hole Depth
- 359.36 m
- Intercept Depth
- 259 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26010:259-290.99
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 50 °
- Dip
- -60 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 100
- Cutoff Unit
- ppm W
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This broad tungsten intercept further confirms the presence of valuable tungsten mineralization at Kismet.
Positive factors
- Moderate tungsten grade over a significant width.
- Indicates consistent tungsten mineralization at Kismet.
Evidence · text
“31.99 m of 558 ppm W (0.07% WO3) from 259.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26009Freeze · copperGrade: 0.31Grade Unit: %Intercept: 4.91 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- KSMT26009
- Project
- Freeze
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 0.31
- Grade Unit
- %
- Intercept
- 4.91 m
- From
- 202.09 m
- To
- 207 m
- Hole Depth
- 240.49 m
- Intercept Depth
- 202.09 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26009:202.09-207
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 326 °
- Dip
- -56 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.35
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This is a narrow, moderate-grade copper intercept, contributing to the overall mineralization picture at Kismet but not a highlight.
Positive factors
- Moderate copper grade.
Negative factors
- Narrow intercept width.
- True width not known.
Evidence · text
“4.91 m of 0.31% Cu and 2.86 g/t Ag (0.35% CuEq) from 202.09 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26009Freeze · silverGrade: 2.86Grade Unit: g/tIntercept: 4.91 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- KSMT26009
- Project
- Freeze
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 2.86
- Grade Unit
- g/t
- Intercept
- 4.91 m
- From
- 202.09 m
- To
- 207 m
- Hole Depth
- 240.49 m
- Intercept Depth
- 202.09 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26009:202.09-207
- Mining Method
- open_pit
Location
- Location
- Kismet
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 326 °
- Dip
- -56 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This narrow silver intercept provides a minor byproduct credit within a narrow copper zone.
Positive factors
- Silver present as a byproduct.
Negative factors
- Low silver grade.
Evidence · text
“4.91 m of 0.31% Cu and 2.86 g/t Ag (0.35% CuEq) from 202.09 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26008Freeze · copperGrade: 0.14Grade Unit: %Intercept: 26.98 mView all detailsHide details
Identity
- Hole ID
- KSMT26008
- Project
- Freeze
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 0.14
- Grade Unit
- %
- Intercept
- 26.98 m
- From
- 241 m
- To
- 267.98 m
- Hole Depth
- 514.2 m
- Intercept Depth
- 241 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26008:241-267.98
- Mining Method
- open_pit
Location
- Location
- North Breccia
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 270 °
- Dip
- -60 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.15
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This intercept represents weak copper mineralization on the periphery of the system, consistent with the company's interpretation.
Positive factors
- Indicates peripheral mineralization.
Negative factors
- Weak copper grade for a porphyry deposit.
- True width not known.
Evidence · text
“26.98 m of 0.14% Cu (0.15% CuEq) from 241.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26011Freeze · copperGrade: 0.11Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- KSMT26011
- Project
- Freeze
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 0.11
- Grade Unit
- %
- Intercept
- 2 m
- From
- 60 m
- To
- 62 m
- Hole Depth
- 259.19 m
- Intercept Depth
- 60 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26011:60-62
- Mining Method
- open_pit
Location
- Location
- North Breccia
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 270 °
- Dip
- -60 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.17
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This is a very narrow, weak copper intercept, indicating peripheral mineralization at North Breccia.
Positive factors
- Indicates peripheral mineralization.
Negative factors
- Weak copper grade.
- Very narrow intercept width.
- True width not known.
Evidence · text
“2.00 m of 0.11% Cu, 73 ppm Mo and 0.34 g/t Ag (0.17% CuEq) from 60.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26011Freeze · molybdenumGrade: 73Grade Unit: ppmIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- KSMT26011
- Project
- Freeze
- Commodity
- molybdenum
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 73
- Grade Unit
- ppm
- Intercept
- 2 m
- From
- 60 m
- To
- 62 m
- Hole Depth
- 259.19 m
- Intercept Depth
- 60 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26011:60-62
- Mining Method
- open_pit
Location
- Location
- North Breccia
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 270 °
- Dip
- -60 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This very low-grade molybdenum intercept provides a minor byproduct credit within a narrow copper zone.
Positive factors
- Molybdenum present as a byproduct.
Negative factors
- Very low molybdenum grade.
Evidence · text
“2.00 m of 0.11% Cu, 73 ppm Mo and 0.34 g/t Ag (0.17% CuEq) from 60.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
KSMT26011Freeze · silverGrade: 0.34Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- KSMT26011
- Project
- Freeze
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- IDEX.V
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 60 m
- To
- 62 m
- Hole Depth
- 259.19 m
- Intercept Depth
- 60 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- KSMT26011:60-62
- Mining Method
- open_pit
Location
- Location
- North Breccia
- CRS
- NAD83 UTM Zone 11N
- Azimuth
- 270 °
- Dip
- -60 °
- Loc. Source
- document
QA/QC
- Laboratory
- AGAT Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.1
- Cutoff Unit
- % Cu
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-12T00:00:00.000Z
Reasoning: This very low-grade silver intercept provides a minor byproduct credit within a narrow copper zone.
Positive factors
- Silver present as a byproduct.
Negative factors
- Very low silver grade.
Evidence · text
“2.00 m of 0.11% Cu, 73 ppm Mo and 0.34 g/t Ag (0.17% CuEq) from 60.00 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "# IDEX Intersects Evidence of a Magmatic-Hydrothermal System at the Shiver Target and Reports Initial 2026 Assays, Inclu"
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.