HWK: Response to ASX Query Letter
Original announcement by asx on
- Company
- Hawk Resources Limited
- Ticker
- HWK
- Exchange
- ASX
- Region
- Western Australia
- Primary commodity
- Scandium
- Secondary commodities
- Copper
- Document categories
- Other, Drill results
- Extracted
- 2026-11-02 10:12:59 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Hawk Resources Limited is responding to an ASX query letter regarding the accuracy of historical pXRF scandium results at the Olympus Scandium Project. The company admits that historical pXRF data was unreliable due to potential calcium/scandium peak overlaps and will henceforth rely solely on laboratory assays.
Reasoning: The document is a formal response to an ASX query regarding the reliability of historical pXRF data which significantly overstated scandium grades. The revelation that historical data was unreliable led to a massive share price collapse.
Positive factors
- Compliance with ASX Listing Rules and JORC Code confirmed
- Commitment to use only laboratory assays moving forward
Negative factors
- Significant discrepancy between historical pXRF results and lab assays
- Historical pXRF results found to be unreliable due to calcium/scandium peak overlap
- 70% share price decrease following previous announcement of historical data
- Lack of historical QA/QC, calibration, or sampling records
Facts used in scoring: 7

Classification and evidence
No QA/QC Disclosurenegative · Story-specific tag
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: The company admitted no information on calibration, quality control, or verification of sampling was available for the historical pXRF results.
Evidence · text
“No historical samples or RAB drill chips, or records of the calibration of the pXRF analyser or the quality control procedures used, were available.”
Extracted facts
Stored fact records: 7. Some facts used in scoring do not have a stored record.
Drill Results (7)
Fact 1scandiumGrade: 4.78Grade Unit: ppmNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Commodity
- scandium
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- HWK
Geometry
- Grade
- 4.78
- Grade Unit
- ppm
Classification
- Sample Type
- drill
- Group ID
- A18557:0-0
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- low_confidence
- Historical
- No
Dates
- Event date
- 2026-11-02T00:00:00.000Z
Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.
Negative factors
- Significant discrepancy from historical pXRF result (742.00 ppm)
Evidence · table
“4.78”
Context: A18557
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 2scandiumGrade: 4.65Grade Unit: ppmNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Commodity
- scandium
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- HWK
Geometry
- Grade
- 4.65
- Grade Unit
- ppm
Classification
- Sample Type
- drill
- Group ID
- A18558:0-0
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- low_confidence
- Historical
- No
Dates
- Event date
- 2026-11-02T00:00:00.000Z
Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.
Negative factors
- Significant discrepancy from historical pXRF result (16.00 ppm)
Evidence · table
“4.65”
Context: A18558
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 3scandiumGrade: 10.35Grade Unit: ppmNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Commodity
- scandium
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- HWK
Geometry
- Grade
- 10.35
- Grade Unit
- ppm
Classification
- Sample Type
- drill
- Group ID
- A18560:0-0
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- low_confidence
- Historical
- No
Dates
- Event date
- 2026-11-02T00:00:00.000Z
Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.
Negative factors
- Significant discrepancy from historical pXRF result (611.00 ppm)
Evidence · table
“10.35”
Context: A18560
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 4scandiumGrade: 3.73Grade Unit: ppmNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Commodity
- scandium
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- HWK
Geometry
- Grade
- 3.73
- Grade Unit
- ppm
Classification
- Sample Type
- drill
- Group ID
- A18559:0-0
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- low_confidence
- Historical
- No
Dates
- Event date
- 2026-11-02T00:00:00.000Z
Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.
Negative factors
- Significant discrepancy from historical pXRF result (510.00 ppm)
Evidence · table
“3.73”
Context: A18559
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 5scandiumGrade: 8.75Grade Unit: ppmNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Commodity
- scandium
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- HWK
Geometry
- Grade
- 8.75
- Grade Unit
- ppm
Classification
- Sample Type
- drill
- Group ID
- A18561:0-0
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- low_confidence
- Historical
- No
Dates
- Event date
- 2026-11-02T00:00:00.000Z
Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.
Negative factors
- Significant discrepancy from historical pXRF result (339.00 ppm)
Evidence · table
“8.75”
Context: A18561
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 6scandiumGrade: 10.55Grade Unit: ppmNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Commodity
- scandium
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- HWK
Geometry
- Grade
- 10.55
- Grade Unit
- ppm
Classification
- Sample Type
- drill
- Group ID
- A18562:0-0
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- low_confidence
- Historical
- No
Dates
- Event date
- 2026-11-02T00:00:00.000Z
Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.
Negative factors
- Significant discrepancy from historical pXRF result (212.00 ppm)
Evidence · table
“10.55”
Context: A18562
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 7scandiumGrade: 4.88Grade Unit: ppmNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Commodity
- scandium
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- HWK
Geometry
- Grade
- 4.88
- Grade Unit
- ppm
Classification
- Sample Type
- drill
- Group ID
- A18563:0-0
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- low_confidence
- Historical
- No
Dates
- Event date
- 2026-11-02T00:00:00.000Z
Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.
Negative factors
- Significant discrepancy from historical pXRF result (352.00 ppm)
Evidence · table
“4.88”
Context: A18563
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.