HWK: Response to ASX Query Letter

Original announcement by asx on

Company
Hawk Resources Limited
Ticker
HWK
Exchange
ASX
Region
Western Australia
Primary commodity
Scandium
Secondary commodities
Copper
Document categories
Other, Drill results
Extracted
2026-11-02 10:12:59 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Hawk Resources Limited is responding to an ASX query letter regarding the accuracy of historical pXRF scandium results at the Olympus Scandium Project. The company admits that historical pXRF data was unreliable due to potential calcium/scandium peak overlaps and will henceforth rely solely on laboratory assays.

Reasoning: The document is a formal response to an ASX query regarding the reliability of historical pXRF data which significantly overstated scandium grades. The revelation that historical data was unreliable led to a massive share price collapse.

Positive factors

  • Compliance with ASX Listing Rules and JORC Code confirmed
  • Commitment to use only laboratory assays moving forward

Negative factors

  • Significant discrepancy between historical pXRF results and lab assays
  • Historical pXRF results found to be unreliable due to calcium/scandium peak overlap
  • 70% share price decrease following previous announcement of historical data
  • Lack of historical QA/QC, calibration, or sampling records

Facts used in scoring: 7

Atlas analysis — Hawk Resources Limited: HWK: Response to ASX Query Letter

Classification and evidence

No QA/QC Disclosurenegative · Story-specific tag

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: The company admitted no information on calibration, quality control, or verification of sampling was available for the historical pXRF results.

Evidence · text

“No historical samples or RAB drill chips, or records of the calibration of the pXRF analyser or the quality control procedures used, were available.”

Extracted facts

Stored fact records: 7. Some facts used in scoring do not have a stored record.

Drill Results (7)

Fact 1scandiumGrade: 4.78Grade Unit: ppmNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Commodity
scandium
Region
australia_wa
Reported Region
australia_wa
Ticker
HWK

Geometry

Grade
4.78
Grade Unit
ppm

Classification

Sample Type
drill
Group ID
A18557:0-0

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
standards

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
low_confidence
Historical
No

Dates

Event date
2026-11-02T00:00:00.000Z

Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.

Negative factors

  • Significant discrepancy from historical pXRF result (742.00 ppm)

Evidence · table

“4.78”

Context: A18557

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 2scandiumGrade: 4.65Grade Unit: ppmNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Commodity
scandium
Region
australia_wa
Reported Region
australia_wa
Ticker
HWK

Geometry

Grade
4.65
Grade Unit
ppm

Classification

Sample Type
drill
Group ID
A18558:0-0

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
standards

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
low_confidence
Historical
No

Dates

Event date
2026-11-02T00:00:00.000Z

Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.

Negative factors

  • Significant discrepancy from historical pXRF result (16.00 ppm)

Evidence · table

“4.65”

Context: A18558

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 3scandiumGrade: 10.35Grade Unit: ppmNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Commodity
scandium
Region
australia_wa
Reported Region
australia_wa
Ticker
HWK

Geometry

Grade
10.35
Grade Unit
ppm

Classification

Sample Type
drill
Group ID
A18560:0-0

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
standards

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
low_confidence
Historical
No

Dates

Event date
2026-11-02T00:00:00.000Z

Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.

Negative factors

  • Significant discrepancy from historical pXRF result (611.00 ppm)

Evidence · table

“10.35”

Context: A18560

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 4scandiumGrade: 3.73Grade Unit: ppmNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Commodity
scandium
Region
australia_wa
Reported Region
australia_wa
Ticker
HWK

Geometry

Grade
3.73
Grade Unit
ppm

Classification

Sample Type
drill
Group ID
A18559:0-0

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
standards

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
low_confidence
Historical
No

Dates

Event date
2026-11-02T00:00:00.000Z

Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.

Negative factors

  • Significant discrepancy from historical pXRF result (510.00 ppm)

Evidence · table

“3.73”

Context: A18559

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 5scandiumGrade: 8.75Grade Unit: ppmNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Commodity
scandium
Region
australia_wa
Reported Region
australia_wa
Ticker
HWK

Geometry

Grade
8.75
Grade Unit
ppm

Classification

Sample Type
drill
Group ID
A18561:0-0

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
standards

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
low_confidence
Historical
No

Dates

Event date
2026-11-02T00:00:00.000Z

Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.

Negative factors

  • Significant discrepancy from historical pXRF result (339.00 ppm)

Evidence · table

“8.75”

Context: A18561

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 6scandiumGrade: 10.55Grade Unit: ppmNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Commodity
scandium
Region
australia_wa
Reported Region
australia_wa
Ticker
HWK

Geometry

Grade
10.55
Grade Unit
ppm

Classification

Sample Type
drill
Group ID
A18562:0-0

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
standards

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
low_confidence
Historical
No

Dates

Event date
2026-11-02T00:00:00.000Z

Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.

Negative factors

  • Significant discrepancy from historical pXRF result (212.00 ppm)

Evidence · table

“10.55”

Context: A18562

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 7scandiumGrade: 4.88Grade Unit: ppmNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Commodity
scandium
Region
australia_wa
Reported Region
australia_wa
Ticker
HWK

Geometry

Grade
4.88
Grade Unit
ppm

Classification

Sample Type
drill
Group ID
A18563:0-0

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
standards

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
low_confidence
Historical
No

Dates

Event date
2026-11-02T00:00:00.000Z

Reasoning: Lab assay shows extremely low scandium compared to historical pXRF data.

Negative factors

  • Significant discrepancy from historical pXRF result (352.00 ppm)

Evidence · table

“4.88”

Context: A18563

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.