GBM: Broad High Grade Gold Intersected Outside Lone Sister MRE

Original announcement by asx on

Company
GBM Resources Limited
Ticker
GBM
Exchange
ASX
Region
Queensland
Primary commodity
Unavailable
Secondary commodities
None reported
Document categories
Drill results, Resource update
Extracted
2026-11-08 22:30:18 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

GBM Resources Limited announced excellent assay results from its Stage 2 drilling program at the Twin Hills Gold Project in Queensland. Highlights include a broad 50m at 2.01g/t gold from 246m in hole LSDH018, located entirely outside the current Lone Sister Mineral Resource Estimate (MRE), and further strong intersections at both Lone Sister and 309 deposits. These results are expected to support an improved resource classification and potential for resource growth and grade uplift in the upcoming MRE update.

Reasoning: The announcement reports excellent broad, high-grade gold intercepts, including significant mineralization outside the current MRE, which indicates strong potential for resource expansion and grade uplift. The drilling program also aims to improve resource classification, supported by robust QA/QC. The only minor negative is the lack of true width disclosure.

Positive factors

  • Broad high-grade gold intercepts, particularly 50m @ 2.01g/t Au, indicating significant mineralization.
  • Intercepts located entirely outside the current MRE, suggesting potential for resource expansion.
  • High-grade sub-intervals (e.g., 1m @ 16.95g/t Au) demonstrate strong mineralization within broader zones.
  • Drilling aims to improve resource confidence and increase Measured and Indicated categories, de-risking the project.
  • Comprehensive QA/QC procedures are disclosed, including certified labs and QP sign-off, enhancing data credibility.

Negative factors

  • True widths of intercepts are not known, which may overstate actual thickness.

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 73

Atlas analysis — GBM Resources Limited: GBM: Broad High Grade Gold Intersected Outside Lone Sister MRE. 2.01 g/t over 50 m; 2.96 g/t over 16 m; 1.28 g/t over 27 m

Extracted facts

Stored fact records: 73. Some facts used in scoring do not have a stored record.

Drill Results (73)

LSDH018Twin Hills · goldGrade: 2.01Grade Unit: g/tIntercept: 50 mView all details
Link to this fact

Identity

Hole ID
LSDH018
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
2.01
Grade Unit
g/t
Intercept
50 m
From
246 m
To
296 m
Hole Depth
447.1 m
Intercept Depth
246 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
LSDH018:246-296
Mining Method
mixed

Location

Location
Lone Sister
Easting
508197
Northing
7568210
CRS
MGA Zone 55 GDA94
Elevation
239 m
Azimuth
90 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is an excellent broad intercept with a strong grade, located outside the current MRE, indicating significant potential for resource expansion. The GT product is strong, and the grade is good for the deposit type and width.

Positive factors

  • Exceptional intercept length of 50m with a strong grade of 2.01 g/t Au.
  • Located entirely outside the current MRE, indicating significant potential for resource expansion.
  • High GT product (100.5 g/t*m) for a broad intercept, exceeding project average GT.
  • Grade is moderate for epithermal deposits but excellent given the width.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · text

“50m @ 2.01g/t Au from 246m (LSDH018), including:”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Step-Out ExtensionRejected · positive

Mineralization extended beyond the previously known limit.

Reason: The intercept is explicitly stated as being 'entirely outside the current Lone Sister MRE'.

Evidence · text

“entirely outside the current Lone Sister MRE”

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
LSDH018Twin Hills · goldGrade: 3.41Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
LSDH018
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
3.41
Grade Unit
g/t
Intercept
3 m
From
269 m
To
272 m
Hole Depth
447.1 m
Intercept Depth
246 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
LSDH018:269-272
Mining Method
mixed

Location

Location
Lone Sister
Easting
508197
Northing
7568210
CRS
MGA Zone 55 GDA94
Elevation
239 m
Azimuth
90 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong high-grade sub-interval within a broader zone, contributing positively to the overall intercept, but its narrow width limits its individual materiality.

Positive factors

  • High-grade sub-interval of 3.41 g/t Au, contributing to the overall broad intercept.
  • Grade is strong for epithermal deposits, indicating good mineralization.

Negative factors

  • Narrow intercept length of 3m.
  • True width is not known, which may overstate the actual thickness.

Evidence · text

“3m @ 3.41g/t Au from 269m”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
LSDH018Twin Hills · goldGrade: 4.2Grade Unit: g/tIntercept: 10 mView all details
Link to this fact

Identity

Hole ID
LSDH018
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
4.2
Grade Unit
g/t
Intercept
10 m
From
279 m
To
289 m
Hole Depth
447.1 m
Intercept Depth
246 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
LSDH018:279-289
Mining Method
mixed

Location

Location
Lone Sister
Easting
508197
Northing
7568210
CRS
MGA Zone 55 GDA94
Elevation
239 m
Azimuth
90 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong high-grade sub-interval within a broader zone, with a grade above the 75th percentile for epithermal deposits, indicating good mineralization and contributing positively to the overall intercept.

Positive factors

  • Strong high-grade sub-interval of 10m @ 4.20 g/t Au, significantly contributing to the overall broad intercept.
  • Grade is strong for epithermal deposits and above the 75th percentile for the deposit type.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · text

“10m @ 4.20g/t Au from 279m”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
LSDH018Twin Hills · goldGrade: 6.99Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
LSDH018
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
6.99
Grade Unit
g/t
Intercept
3 m
From
293 m
To
296 m
Hole Depth
447.1 m
Intercept Depth
246 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
LSDH018:293-296
Mining Method
mixed

Location

Location
Lone Sister
Easting
508197
Northing
7568210
CRS
MGA Zone 55 GDA94
Elevation
239 m
Azimuth
90 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong high-grade sub-interval within a broader zone, with a grade well above the 75th percentile for epithermal deposits, indicating good mineralization and contributing positively to the overall intercept.

Positive factors

  • High-grade sub-interval of 6.99 g/t Au, contributing to the overall broad intercept.
  • Grade is strong for epithermal deposits and well above the 75th percentile for the deposit type.

Negative factors

  • Narrow intercept length of 3m.
  • True width is not known, which may overstate the actual thickness.

Evidence · text

“3m @ 6.99g/t Au from 293m”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
LSDH022Twin Hills · goldGrade: 2.96Grade Unit: g/tIntercept: 16 mView all details
Link to this fact

Identity

Hole ID
LSDH022
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
2.96
Grade Unit
g/t
Intercept
16 m
From
430 m
To
446 m
Hole Depth
500 m
Intercept Depth
430 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
LSDH022:430-446
Mining Method
mixed

Location

Location
Lone Sister
Easting
508608
Northing
7568384
CRS
MGA Zone 55 GDA94
Elevation
243 m
Azimuth
270 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong intercept with a good grade, located outside the current MRE, indicating potential for resource expansion. The grade is above the 75th percentile for epithermal deposits.

Positive factors

  • Strong intercept of 16m @ 2.96 g/t Au, indicating good mineralization.
  • Located outside the current MRE, suggesting potential for resource expansion.
  • Grade is strong for epithermal deposits and above the 75th percentile for the deposit type.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · text

“16m @ 2.96g/t Au from 430m (LSDH022 – outside MRE)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Step-Out ExtensionRejected · positive

Mineralization extended beyond the previously known limit.

Reason: The intercept is explicitly stated as being 'outside MRE'.

Evidence · text

“outside MRE”

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
LSDH022Twin Hills · goldGrade: 3.95Grade Unit: g/tIntercept: 6 mView all details
Link to this fact

Identity

Hole ID
LSDH022
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
3.95
Grade Unit
g/t
Intercept
6 m
From
433 m
To
439 m
Hole Depth
500 m
Intercept Depth
430 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
LSDH022:433-439
Mining Method
mixed

Location

Location
Lone Sister
Easting
508608
Northing
7568384
CRS
MGA Zone 55 GDA94
Elevation
243 m
Azimuth
270 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong high-grade sub-interval within a broader zone, with a grade above the 75th percentile for epithermal deposits, indicating good mineralization and contributing positively to the overall intercept.

Positive factors

  • Strong high-grade sub-interval of 6m @ 3.95 g/t Au, contributing to the overall intercept.
  • Grade is strong for epithermal deposits and above the 75th percentile for the deposit type.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · text

“6m @ 3.95g/t Au from 433m”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
LSDH022Twin Hills · goldGrade: 7Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
LSDH022
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
7
Grade Unit
g/t
Intercept
2 m
From
443 m
To
445 m
Hole Depth
500 m
Intercept Depth
430 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
LSDH022:443-445
Mining Method
mixed

Location

Location
Lone Sister
Easting
508608
Northing
7568384
CRS
MGA Zone 55 GDA94
Elevation
243 m
Azimuth
270 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong high-grade sub-interval within a broader zone, with a grade well above the 75th percentile for epithermal deposits, indicating good mineralization and contributing positively to the overall intercept.

Positive factors

  • High-grade sub-interval of 7.00 g/t Au, contributing to the overall intercept.
  • Grade is strong for epithermal deposits and well above the 75th percentile for the deposit type.

Negative factors

  • Narrow intercept length of 2m.
  • True width is not known, which may overstate the actual thickness.

Evidence · text

“2m @ 7.00g/t Au from 443m”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
LSDH014Twin Hills · goldGrade: 3.04Grade Unit: g/tIntercept: 10 mView all details
Link to this fact

Identity

Hole ID
LSDH014
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
3.04
Grade Unit
g/t
Intercept
10 m
From
323 m
To
333 m
Hole Depth
624.7 m
Intercept Depth
323 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
LSDH014:323-333
Mining Method
mixed

Location

Location
Lone Sister
Easting
508351
Northing
7568539
CRS
MGA Zone 55 GDA94
Elevation
240 m
Azimuth
175 °
Dip
-57 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong intercept with a good grade, above the 75th percentile for epithermal deposits, indicating good mineralization.

Positive factors

  • Strong intercept of 10m @ 3.04 g/t Au, indicating good mineralization.
  • Grade is strong for epithermal deposits and above the 75th percentile for the deposit type.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · text

“10m @ 3.04g/t Au from 323m (LSDH014)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
LSDH014Twin Hills · goldGrade: 16.95Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LSDH014
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
16.95
Grade Unit
g/t
Intercept
1 m
From
331 m
To
332 m
Hole Depth
624.7 m
Intercept Depth
323 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
LSDH014:331-332
Mining Method
mixed

Location

Location
Lone Sister
Easting
508351
Northing
7568539
CRS
MGA Zone 55 GDA94
Elevation
240 m
Azimuth
175 °
Dip
-57 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is an exceptional high-grade sub-interval, with a grade well above the average and 75th percentile for epithermal deposits, indicating bonanza-grade mineralization within the broader zone.

Positive factors

  • Exceptional high-grade sub-interval of 16.95 g/t Au, significantly contributing to the overall intercept.
  • Grade is exceptional for epithermal deposits and well above the average and 75th percentile for the deposit type.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · text

“1m @ 16.95g/t Au from 331m”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The grade of 16.95 g/t Au is well above the exceptional threshold for epithermal gold deposits (5 g/t).

Evidence · text

“1m @ 16.95g/t Au from 331m”

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH042Twin Hills · goldGrade: 1.28Grade Unit: g/tIntercept: 27 mView all details
Link to this fact

Identity

Hole ID
TNDH042
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.28
Grade Unit
g/t
Intercept
27 m
From
275 m
To
302 m
Hole Depth
390 m
Intercept Depth
275 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH042:275-302
Mining Method
mixed

Location

Location
309
Easting
505676
Northing
7575432
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
283 °
Dip
-54 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a good broad intercept with a moderate grade, located outside the current MRE, indicating potential for resource expansion.

Positive factors

  • Broad intercept of 27m @ 1.28 g/t Au, indicating good mineralization.
  • Located outside the current MRE, suggesting potential for resource expansion.
  • Grade is moderate for epithermal deposits but good given the width.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · text

“27m @ 1.28g/t Au from 275m (TNDH042)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Step-Out ExtensionRejected · positive

Mineralization extended beyond the previously known limit.

Reason: The intercept is explicitly stated as being 'outside of the current MRE'.

Evidence · text

“outside of the current MRE”

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH042Twin Hills · goldGrade: 2Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
TNDH042
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
2
Grade Unit
g/t
Intercept
4 m
From
280 m
To
284 m
Hole Depth
390 m
Intercept Depth
275 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH042:280-284
Mining Method
mixed

Location

Location
309
Easting
505676
Northing
7575432
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
283 °
Dip
-54 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong high-grade sub-interval within a broader zone, indicating good mineralization and contributing positively to the overall intercept.

Positive factors

  • High-grade sub-interval of 4m @ 2.00 g/t Au, contributing to the overall broad intercept.
  • Grade is strong for epithermal deposits.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · text

“4m @ 2.00g/t Au from 280m”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH065Twin Hills · goldGrade: 1.53Grade Unit: g/tIntercept: 18 mView all details
Link to this fact

Identity

Hole ID
TNDH065
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.53
Grade Unit
g/t
Intercept
18 m
From
333 m
To
351 m
Hole Depth
550 m
Intercept Depth
333 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH065:333-351
Mining Method
mixed

Location

Location
309
Easting
505395
Northing
7575882
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
177 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a good broad intercept with a moderate grade, located outside the current MRE, indicating potential for resource expansion.

Positive factors

  • Broad intercept of 18m @ 1.53 g/t Au, indicating good mineralization.
  • Located outside the current MRE, suggesting potential for resource expansion.
  • Grade is moderate for epithermal deposits but good given the width.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · text

“18m @ 1.53g/t Au from 333m (TNDH065)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Step-Out ExtensionRejected · positive

Mineralization extended beyond the previously known limit.

Reason: The intercept is explicitly stated as being 'outside of the current MRE'.

Evidence · text

“outside of the current MRE”

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH065Twin Hills · goldGrade: 5.1Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
TNDH065
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
5.1
Grade Unit
g/t
Intercept
3 m
From
333 m
To
336 m
Hole Depth
550 m
Intercept Depth
333 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH065:333-336
Mining Method
mixed

Location

Location
309
Easting
505395
Northing
7575882
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
177 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is an exceptional high-grade sub-interval within a broader zone, with a grade well above the 75th percentile for epithermal deposits, indicating bonanza-grade mineralization and contributing positively to the overall intercept.

Positive factors

  • High-grade sub-interval of 3m @ 5.10 g/t Au, contributing to the overall broad intercept.
  • Grade is exceptional for epithermal deposits and well above the 75th percentile for the deposit type.

Negative factors

  • Narrow intercept length of 3m.
  • True width is not known, which may overstate the actual thickness.

Evidence · text

“3m @ 5.10g/t Au from 333m”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The grade of 5.10 g/t Au is at or above the exceptional threshold for epithermal gold deposits (5 g/t).

Evidence · text

“3m @ 5.10g/t Au from 333m”

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH059Twin Hills · goldGrade: 1.61Grade Unit: g/tIntercept: 13 mView all details
Link to this fact

Identity

Hole ID
TNDH059
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.61
Grade Unit
g/t
Intercept
13 m
From
313 m
To
326 m
Hole Depth
366.8 m
Intercept Depth
313 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH059:313-326
Mining Method
mixed

Location

Location
309
Easting
505507
Northing
7575399
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
9 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a good broad intercept with a moderate grade, located outside the current MRE, indicating potential for resource expansion.

Positive factors

  • Broad intercept of 13m @ 1.61 g/t Au, indicating good mineralization.
  • Located outside the current MRE, suggesting potential for resource expansion.
  • Grade is moderate for epithermal deposits but good given the width.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · text

“13m @ 1.61g/t Au from 313m (TNDH059)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Step-Out ExtensionRejected · positive

Mineralization extended beyond the previously known limit.

Reason: The intercept is explicitly stated as being 'outside of the current MRE'.

Evidence · text

“outside of the current MRE”

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH059Twin Hills · goldGrade: 3.42Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
TNDH059
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
3.42
Grade Unit
g/t
Intercept
4 m
From
318 m
To
322 m
Hole Depth
366.8 m
Intercept Depth
313 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH059:318-322
Mining Method
mixed

Location

Location
309
Easting
505507
Northing
7575399
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
9 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong high-grade sub-interval within a broader zone, with a grade above the 75th percentile for epithermal deposits, indicating good mineralization and contributing positively to the overall intercept.

Positive factors

  • Strong high-grade sub-interval of 4m @ 3.42 g/t Au, contributing to the overall broad intercept.
  • Grade is strong for epithermal deposits and above the 75th percentile for the deposit type.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · text

“4m @ 3.42g/t Au from 318m”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH064Twin Hills · goldGrade: 4.07Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
TNDH064
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
4.07
Grade Unit
g/t
Intercept
3 m
From
241 m
To
244 m
Hole Depth
573.3 m
Intercept Depth
241 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH064:241-244
Mining Method
mixed

Location

Location
309
Easting
505454
Northing
7575876
CRS
MGA Zone 55 GDA94
Elevation
252 m
Azimuth
190 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong high-grade intercept, located outside the current MRE, indicating potential for resource expansion. The grade is strong for epithermal deposits.

Positive factors

  • Strong high-grade intercept of 3m @ 4.07 g/t Au, indicating good mineralization.
  • Located outside the current MRE, suggesting potential for resource expansion.
  • Grade is strong for epithermal deposits and close to the 75th percentile for the deposit type.

Negative factors

  • Narrow intercept length of 3m.
  • True width is not known, which may overstate the actual thickness.

Evidence · text

“3m @ 4.07g/t Au from 241m (TNDH064)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Step-Out ExtensionRejected · positive

Mineralization extended beyond the previously known limit.

Reason: The intercept is explicitly stated as being 'outside of the current MRE'.

Evidence · text

“outside of the current MRE”

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH009Twin Hills · goldGrade: 0.67Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH009
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.67
Grade Unit
g/t
Intercept
1 m
From
218 m
To
219 m
Hole Depth
624.8 m
Intercept Depth
218 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH009:218-219
Mining Method
mixed

Location

Location
309
Easting
505031
Northing
7575682
CRS
MGA Zone 55 GDA94
Elevation
257 m
Azimuth
100 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own, but contributes to the overall dataset.

Negative factors

  • Low grade of 0.67 g/t Au, below the moderate threshold for epithermal deposits.
  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.67”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH009Twin Hills · goldGrade: 0.3Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
TNDH009
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
4 m
From
236 m
To
240 m
Hole Depth
624.8 m
Intercept Depth
218 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH009:236-240
Mining Method
mixed

Location

Location
309
Easting
505031
Northing
7575682
CRS
MGA Zone 55 GDA94
Elevation
257 m
Azimuth
100 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade intercept, below the weak threshold for epithermal deposits, and not particularly material.

Negative factors

  • Low grade of 0.3 g/t Au, below the weak threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.30”

Context: 4.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH010Twin Hills · goldGrade: 0.88Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TNDH010
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.88
Grade Unit
g/t
Intercept
2 m
From
88 m
To
90 m
Hole Depth
387.8 m
Intercept Depth
88 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH010:88-90
Mining Method
mixed

Location

Location
309
Easting
505301
Northing
7575717
CRS
MGA Zone 55 GDA94
Elevation
256 m
Azimuth
100 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Moderate grade of 0.88 g/t Au, but narrow intercept length of 2m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.88”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH013Twin Hills · goldGrade: 0.4Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH013
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.4
Grade Unit
g/t
Intercept
1 m
From
301 m
To
302 m
Hole Depth
423.5 m
Intercept Depth
301 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH013:301-302
Mining Method
mixed

Location

Location
309
Easting
505371
Northing
7575266
CRS
MGA Zone 55 GDA94
Elevation
254 m
Azimuth
9 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.4 g/t Au, at the weak threshold for epithermal deposits.
  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.40”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH023Twin Hills · goldGrade: 1.52Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH023
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.52
Grade Unit
g/t
Intercept
1 m
From
530 m
To
531 m
Hole Depth
600 m
Intercept Depth
530 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH023:530-531
Mining Method
mixed

Location

Location
309
Easting
505243
Northing
7575341
CRS
MGA Zone 55 GDA94
Elevation
255 m
Azimuth
8 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade, narrow intercept, which is not particularly material on its own.

Positive factors

  • Moderate grade of 1.52 g/t Au, above the moderate threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“1.52”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH024Twin Hills · goldGrade: 1.06Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH024
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.06
Grade Unit
g/t
Intercept
1 m
From
319 m
To
320 m
Hole Depth
436.2 m
Intercept Depth
319 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH024:319-320
Mining Method
mixed

Location

Location
309
Easting
505384
Northing
7575826
CRS
MGA Zone 55 GDA94
Elevation
254 m
Azimuth
97 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade, narrow intercept, which is not particularly material on its own.

Positive factors

  • Moderate grade of 1.06 g/t Au, at the moderate threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“1.06”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH024Twin Hills · goldGrade: 0.48Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH024
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.48
Grade Unit
g/t
Intercept
1 m
From
333 m
To
334 m
Hole Depth
436.2 m
Intercept Depth
319 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH024:333-334
Mining Method
mixed

Location

Location
309
Easting
505384
Northing
7575826
CRS
MGA Zone 55 GDA94
Elevation
254 m
Azimuth
97 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.48 g/t Au, at the weak threshold for epithermal deposits.
  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.48”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH025Twin Hills · goldGrade: 0.91Grade Unit: g/tIntercept: 6 mView all details
Link to this fact

Identity

Hole ID
TNDH025
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.91
Grade Unit
g/t
Intercept
6 m
From
289 m
To
295 m
Hole Depth
428.3 m
Intercept Depth
289 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH025:289-295
Mining Method
mixed

Location

Location
309
Easting
505357
Northing
7575302
CRS
MGA Zone 55 GDA94
Elevation
254 m
Azimuth
9 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade intercept, which is not particularly material on its own.

Negative factors

  • Moderate grade of 0.91 g/t Au, but below the moderate threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.91”

Context: 6.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH025Twin Hills · goldGrade: 2.14Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH025
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
2.14
Grade Unit
g/t
Intercept
1 m
From
292 m
To
293 m
Hole Depth
428.3 m
Intercept Depth
289 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH025:292-293
Mining Method
mixed

Location

Location
309
Easting
505357
Northing
7575302
CRS
MGA Zone 55 GDA94
Elevation
254 m
Azimuth
9 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong-grade, narrow intercept, which is not particularly material on its own, but contributes to the overall dataset.

Positive factors

  • Strong grade of 2.14 g/t Au, above the strong threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“2.14”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH025Twin Hills · goldGrade: 0.97Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TNDH025
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.97
Grade Unit
g/t
Intercept
2 m
From
307 m
To
309 m
Hole Depth
428.3 m
Intercept Depth
289 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH025:307-309
Mining Method
mixed

Location

Location
309
Easting
505357
Northing
7575302
CRS
MGA Zone 55 GDA94
Elevation
254 m
Azimuth
9 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Moderate grade of 0.97 g/t Au, but narrow intercept length of 2m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.97”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH033Twin Hills · goldGrade: 0.72Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
TNDH033
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.72
Grade Unit
g/t
Intercept
5 m
From
237 m
To
242 m
Hole Depth
436.8 m
Intercept Depth
237 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH033:237-242
Mining Method
mixed

Location

Location
309
Easting
505420
Northing
7575299
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
8 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.72 g/t Au, below the moderate threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.72”

Context: 5.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH033Twin Hills · goldGrade: 0.63Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
TNDH033
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.63
Grade Unit
g/t
Intercept
3 m
From
268 m
To
271 m
Hole Depth
436.8 m
Intercept Depth
237 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH033:268-271
Mining Method
mixed

Location

Location
309
Easting
505420
Northing
7575299
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
8 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.63 g/t Au, below the moderate threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.63”

Context: 3.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH033Twin Hills · goldGrade: 1.22Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
TNDH033
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.22
Grade Unit
g/t
Intercept
5 m
From
295 m
To
300 m
Hole Depth
436.8 m
Intercept Depth
237 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH033:295-300
Mining Method
mixed

Location

Location
309
Easting
505420
Northing
7575299
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
8 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade intercept, which is not particularly material on its own.

Positive factors

  • Moderate grade of 1.22 g/t Au, above the moderate threshold for epithermal deposits.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · table

“1.22”

Context: 5.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH033Twin Hills · goldGrade: 2.2Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TNDH033
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
2.2
Grade Unit
g/t
Intercept
2 m
From
297 m
To
299 m
Hole Depth
436.8 m
Intercept Depth
237 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH033:297-299
Mining Method
mixed

Location

Location
309
Easting
505420
Northing
7575299
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
8 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong-grade, narrow intercept, which is not particularly material on its own, but contributes to the overall dataset.

Positive factors

  • Strong grade of 2.2 g/t Au, above the strong threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 2m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“2.20”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH034Twin Hills · goldGrade: 0.6Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH034
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.6
Grade Unit
g/t
Intercept
1 m
From
254 m
To
255 m
Hole Depth
378.1 m
Intercept Depth
254 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH034:254-255
Mining Method
mixed

Location

Location
309
Easting
505547
Northing
7575328
CRS
MGA Zone 55 GDA94
Elevation
251 m
Azimuth
10 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.6 g/t Au, at the weak threshold for epithermal deposits.
  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.60”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH034Twin Hills · goldGrade: 3.73Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TNDH034
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
3.73
Grade Unit
g/t
Intercept
2 m
From
303 m
To
305 m
Hole Depth
378.1 m
Intercept Depth
254 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH034:303-305
Mining Method
mixed

Location

Location
309
Easting
505547
Northing
7575328
CRS
MGA Zone 55 GDA94
Elevation
251 m
Azimuth
10 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong-grade, narrow intercept, which is not particularly material on its own, but contributes to the overall dataset.

Positive factors

  • Strong grade of 3.73 g/t Au, above the strong threshold for epithermal deposits.

Negative factors

  • Narrow intercept length of 2m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“3.73”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH034Twin Hills · goldGrade: 6.42Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH034
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
6.42
Grade Unit
g/t
Intercept
1 m
From
304 m
To
305 m
Hole Depth
378.1 m
Intercept Depth
254 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH034:304-305
Mining Method
mixed

Location

Location
309
Easting
505547
Northing
7575328
CRS
MGA Zone 55 GDA94
Elevation
251 m
Azimuth
10 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is an exceptional-grade, narrow intercept, which is not particularly material on its own, but indicates bonanza-grade mineralization.

Positive factors

  • Exceptional grade of 6.42 g/t Au, above the exceptional threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“6.42”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The grade of 6.42 g/t Au is well above the exceptional threshold for epithermal gold deposits (5 g/t).

Evidence · table

“6.42”

Context: 1.0

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH036Twin Hills · goldGrade: 0.54Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
TNDH036
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.54
Grade Unit
g/t
Intercept
4 m
From
272 m
To
276 m
Hole Depth
452 m
Intercept Depth
272 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH036:272-276
Mining Method
mixed

Location

Location
309
Easting
505220
Northing
7575747
CRS
MGA Zone 55 GDA94
Elevation
256 m
Azimuth
98 °
Dip
-58 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.54 g/t Au, at the weak threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.54”

Context: 4.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH036Twin Hills · goldGrade: 1.14Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
TNDH036
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.14
Grade Unit
g/t
Intercept
7 m
From
292 m
To
299 m
Hole Depth
452 m
Intercept Depth
272 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH036:292-299
Mining Method
mixed

Location

Location
309
Easting
505220
Northing
7575747
CRS
MGA Zone 55 GDA94
Elevation
256 m
Azimuth
98 °
Dip
-58 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade intercept, which is not particularly material on its own.

Positive factors

  • Moderate grade of 1.14 g/t Au, above the moderate threshold for epithermal deposits.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · table

“1.14”

Context: 7.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH036Twin Hills · goldGrade: 6.09Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH036
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
6.09
Grade Unit
g/t
Intercept
1 m
From
298 m
To
299 m
Hole Depth
452 m
Intercept Depth
272 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH036:298-299
Mining Method
mixed

Location

Location
309
Easting
505220
Northing
7575747
CRS
MGA Zone 55 GDA94
Elevation
256 m
Azimuth
98 °
Dip
-58 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is an exceptional-grade, narrow intercept, which is not particularly material on its own, but indicates bonanza-grade mineralization.

Positive factors

  • Exceptional grade of 6.09 g/t Au, above the exceptional threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“6.09”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The grade of 6.09 g/t Au is well above the exceptional threshold for epithermal gold deposits (5 g/t).

Evidence · table

“6.09”

Context: 1.0

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH036Twin Hills · goldGrade: 0.43Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TNDH036
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.43
Grade Unit
g/t
Intercept
2 m
From
317 m
To
319 m
Hole Depth
452 m
Intercept Depth
272 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH036:317-319
Mining Method
mixed

Location

Location
309
Easting
505220
Northing
7575747
CRS
MGA Zone 55 GDA94
Elevation
256 m
Azimuth
98 °
Dip
-58 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.43 g/t Au, at the weak threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.43”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH037Twin Hills · goldGrade: 0.47Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH037
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.47
Grade Unit
g/t
Intercept
1 m
From
75 m
To
76 m
Hole Depth
367.4 m
Intercept Depth
75 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH037:75-76
Mining Method
mixed

Location

Location
309
Easting
505322
Northing
7575320
CRS
MGA Zone 55 GDA94
Elevation
255 m
Azimuth
11 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.47 g/t Au, at the weak threshold for epithermal deposits.
  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.47”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH037Twin Hills · goldGrade: 0.49Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH037
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.49
Grade Unit
g/t
Intercept
1 m
From
81 m
To
82 m
Hole Depth
367.4 m
Intercept Depth
75 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH037:81-82
Mining Method
mixed

Location

Location
309
Easting
505322
Northing
7575320
CRS
MGA Zone 55 GDA94
Elevation
255 m
Azimuth
11 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.49 g/t Au, at the weak threshold for epithermal deposits.
  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.49”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH037Twin Hills · goldGrade: 0.51Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
TNDH037
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.51
Grade Unit
g/t
Intercept
4 m
From
306 m
To
310 m
Hole Depth
367.4 m
Intercept Depth
75 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH037:306-310
Mining Method
mixed

Location

Location
309
Easting
505322
Northing
7575320
CRS
MGA Zone 55 GDA94
Elevation
255 m
Azimuth
11 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.51 g/t Au, at the weak threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.51”

Context: 4.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH042Twin Hills · goldGrade: 0.49Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TNDH042
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.49
Grade Unit
g/t
Intercept
2 m
From
190 m
To
192 m
Hole Depth
390 m
Intercept Depth
190 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH042:190-192
Mining Method
mixed

Location

Location
309
Easting
505676
Northing
7575432
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
283 °
Dip
-54 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.49 g/t Au, at the weak threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.49”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH042Twin Hills · goldGrade: 0.99Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH042
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.99
Grade Unit
g/t
Intercept
1 m
From
225 m
To
226 m
Hole Depth
390 m
Intercept Depth
190 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH042:225-226
Mining Method
mixed

Location

Location
309
Easting
505676
Northing
7575432
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
283 °
Dip
-54 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Moderate grade of 0.99 g/t Au, but narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.99”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH042Twin Hills · goldGrade: 0.57Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH042
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.57
Grade Unit
g/t
Intercept
1 m
From
240 m
To
241 m
Hole Depth
390 m
Intercept Depth
190 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH042:240-241
Mining Method
mixed

Location

Location
309
Easting
505676
Northing
7575432
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
283 °
Dip
-54 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.57 g/t Au, at the weak threshold for epithermal deposits.
  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.57”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH042Twin Hills · goldGrade: 1.19Grade Unit: g/tIntercept: 8 mView all details
Link to this fact

Identity

Hole ID
TNDH042
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.19
Grade Unit
g/t
Intercept
8 m
From
247 m
To
255 m
Hole Depth
390 m
Intercept Depth
190 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH042:247-255
Mining Method
mixed

Location

Location
309
Easting
505676
Northing
7575432
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
283 °
Dip
-54 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade intercept, which is not particularly material on its own.

Positive factors

  • Moderate grade of 1.19 g/t Au, above the moderate threshold for epithermal deposits.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · table

“1.19”

Context: 8.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH042Twin Hills · goldGrade: 2.99Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH042
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
2.99
Grade Unit
g/t
Intercept
1 m
From
247 m
To
248 m
Hole Depth
390 m
Intercept Depth
190 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH042:247-248
Mining Method
mixed

Location

Location
309
Easting
505676
Northing
7575432
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
283 °
Dip
-54 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong-grade, narrow intercept, which is not particularly material on its own, but contributes to the overall dataset.

Positive factors

  • Strong grade of 2.99 g/t Au, above the strong threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“2.99”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH042Twin Hills · goldGrade: 2Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH042
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
2
Grade Unit
g/t
Intercept
1 m
From
275 m
To
276 m
Hole Depth
390 m
Intercept Depth
190 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH042:275-276
Mining Method
mixed

Location

Location
309
Easting
505676
Northing
7575432
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
283 °
Dip
-54 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong-grade, narrow intercept, which is not particularly material on its own, but contributes to the overall dataset.

Positive factors

  • Strong grade of 2.00 g/t Au, at the strong threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“2.00”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH042Twin Hills · goldGrade: 2.03Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH042
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
2.03
Grade Unit
g/t
Intercept
1 m
From
296 m
To
297 m
Hole Depth
390 m
Intercept Depth
190 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH042:296-297
Mining Method
mixed

Location

Location
309
Easting
505676
Northing
7575432
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
283 °
Dip
-54 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong-grade, narrow intercept, which is not particularly material on its own, but contributes to the overall dataset.

Positive factors

  • Strong grade of 2.03 g/t Au, above the strong threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“2.03”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH042Twin Hills · goldGrade: 0.65Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
TNDH042
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.65
Grade Unit
g/t
Intercept
4 m
From
314 m
To
318 m
Hole Depth
390 m
Intercept Depth
190 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH042:314-318
Mining Method
mixed

Location

Location
309
Easting
505676
Northing
7575432
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
283 °
Dip
-54 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.65 g/t Au, below the moderate threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.65”

Context: 4.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH043Twin Hills · goldGrade: 0.91Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH043
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.91
Grade Unit
g/t
Intercept
1 m
From
112 m
To
113 m
Hole Depth
450.2 m
Intercept Depth
112 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH043:112-113
Mining Method
mixed

Location

Location
309
Easting
505610
Northing
7575944
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
189 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Moderate grade of 0.91 g/t Au, but narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.91”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH043Twin Hills · goldGrade: 1.23Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH043
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.23
Grade Unit
g/t
Intercept
1 m
From
198 m
To
199 m
Hole Depth
450.2 m
Intercept Depth
112 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH043:198-199
Mining Method
mixed

Location

Location
309
Easting
505610
Northing
7575944
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
189 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade, narrow intercept, which is not particularly material on its own.

Positive factors

  • Moderate grade of 1.23 g/t Au, above the moderate threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“1.23”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH043Twin Hills · goldGrade: 0.86Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH043
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.86
Grade Unit
g/t
Intercept
1 m
From
258 m
To
259 m
Hole Depth
450.2 m
Intercept Depth
112 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH043:258-259
Mining Method
mixed

Location

Location
309
Easting
505610
Northing
7575944
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
189 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Moderate grade of 0.86 g/t Au, but narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.86”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH043Twin Hills · goldGrade: 3.99Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH043
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
3.99
Grade Unit
g/t
Intercept
1 m
From
325 m
To
326 m
Hole Depth
450.2 m
Intercept Depth
112 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH043:325-326
Mining Method
mixed

Location

Location
309
Easting
505610
Northing
7575944
CRS
MGA Zone 55 GDA94
Elevation
250 m
Azimuth
189 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong-grade, narrow intercept, which is not particularly material on its own, but contributes to the overall dataset.

Positive factors

  • Strong grade of 3.99 g/t Au, above the strong threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“3.99”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH044Twin Hills · goldGrade: 0.4Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH044
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.4
Grade Unit
g/t
Intercept
1 m
From
172 m
To
173 m
Hole Depth
262 m
Intercept Depth
172 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH044:172-173
Mining Method
mixed

Location

Location
309
Easting
505574
Northing
7575973
CRS
MGA Zone 55 GDA94
Elevation
245 m
Azimuth
190 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.4 g/t Au, at the weak threshold for epithermal deposits.
  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.40”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH044Twin Hills · goldGrade: 0.45Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TNDH044
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.45
Grade Unit
g/t
Intercept
2 m
From
195 m
To
197 m
Hole Depth
262 m
Intercept Depth
172 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH044:195-197
Mining Method
mixed

Location

Location
309
Easting
505574
Northing
7575973
CRS
MGA Zone 55 GDA94
Elevation
245 m
Azimuth
190 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.45 g/t Au, at the weak threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.45”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH044Twin Hills · goldGrade: 0.74Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
TNDH044
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.74
Grade Unit
g/t
Intercept
3 m
From
246 m
To
249 m
Hole Depth
262 m
Intercept Depth
172 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH044:246-249
Mining Method
mixed

Location

Location
309
Easting
505574
Northing
7575973
CRS
MGA Zone 55 GDA94
Elevation
245 m
Azimuth
190 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.74 g/t Au, below the moderate threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.74”

Context: 3.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH044Twin Hills · goldGrade: 0.63Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TNDH044
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.63
Grade Unit
g/t
Intercept
2 m
From
254 m
To
256 m
Hole Depth
262 m
Intercept Depth
172 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH044:254-256
Mining Method
mixed

Location

Location
309
Easting
505574
Northing
7575973
CRS
MGA Zone 55 GDA94
Elevation
245 m
Azimuth
190 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.63 g/t Au, below the moderate threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.63”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH047Twin Hills · goldGrade: 1.1Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH047
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.1
Grade Unit
g/t
Intercept
1 m
From
333 m
To
334 m
Hole Depth
334 m
Intercept Depth
333 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH047:333-334
Mining Method
mixed

Location

Location
309
Easting
505748
Northing
7575442
CRS
MGA Zone 55 GDA94
Elevation
249 m
Azimuth
280 °
Dip
-58 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade, narrow intercept, which is not particularly material on its own.

Positive factors

  • Moderate grade of 1.1 g/t Au, at the moderate threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“1.10”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH057Twin Hills · goldGrade: 0.6Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH057
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.6
Grade Unit
g/t
Intercept
1 m
From
304 m
To
305 m
Hole Depth
359.4 m
Intercept Depth
304 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH057:304-305
Mining Method
mixed

Location

Location
309
Easting
505236
Northing
7575539
CRS
MGA Zone 55 GDA94
Elevation
257 m
Azimuth
95 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.6 g/t Au, at the weak threshold for epithermal deposits.
  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.60”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH059Twin Hills · goldGrade: 0.52Grade Unit: g/tIntercept: 6 mView all details
Link to this fact

Identity

Hole ID
TNDH059
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.52
Grade Unit
g/t
Intercept
6 m
From
179 m
To
185 m
Hole Depth
366.8 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH059:179-185
Mining Method
mixed

Location

Location
309
Easting
505507
Northing
7575399
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
9 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.52 g/t Au, at the weak threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.52”

Context: 6.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH059Twin Hills · goldGrade: 2.74Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH059
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
2.74
Grade Unit
g/t
Intercept
1 m
From
205 m
To
206 m
Hole Depth
366.8 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH059:205-206
Mining Method
mixed

Location

Location
309
Easting
505507
Northing
7575399
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
9 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong-grade, narrow intercept, which is not particularly material on its own, but contributes to the overall dataset.

Positive factors

  • Strong grade of 2.74 g/t Au, above the strong threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“2.74”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH059Twin Hills · goldGrade: 0.48Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH059
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.48
Grade Unit
g/t
Intercept
1 m
From
212 m
To
213 m
Hole Depth
366.8 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH059:212-213
Mining Method
mixed

Location

Location
309
Easting
505507
Northing
7575399
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
9 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.48 g/t Au, at the weak threshold for epithermal deposits.
  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.48”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH059Twin Hills · goldGrade: 0.65Grade Unit: g/tIntercept: 19 mView all details
Link to this fact

Identity

Hole ID
TNDH059
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.65
Grade Unit
g/t
Intercept
19 m
From
218 m
To
237 m
Hole Depth
366.8 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH059:218-237
Mining Method
mixed

Location

Location
309
Easting
505507
Northing
7575399
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
9 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.65 g/t Au, below the moderate threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.65”

Context: 19.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH059Twin Hills · goldGrade: 1.61Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
TNDH059
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.61
Grade Unit
g/t
Intercept
3 m
From
229 m
To
232 m
Hole Depth
366.8 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH059:229-232
Mining Method
mixed

Location

Location
309
Easting
505507
Northing
7575399
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
9 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade, narrow intercept, which is not particularly material on its own, but contributes to the overall dataset.

Positive factors

  • Moderate grade of 1.61 g/t Au, above the moderate threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 3m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“1.61”

Context: 3.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH059Twin Hills · goldGrade: 1.19Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
TNDH059
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.19
Grade Unit
g/t
Intercept
7 m
From
246 m
To
253 m
Hole Depth
366.8 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH059:246-253
Mining Method
mixed

Location

Location
309
Easting
505507
Northing
7575399
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
9 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade intercept, which is not particularly material on its own.

Positive factors

  • Moderate grade of 1.19 g/t Au, above the moderate threshold for epithermal deposits.

Negative factors

  • True width is not known, which may overstate the actual thickness.

Evidence · table

“1.19”

Context: 7.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH059Twin Hills · goldGrade: 3.12Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH059
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
3.12
Grade Unit
g/t
Intercept
1 m
From
251 m
To
252 m
Hole Depth
366.8 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH059:251-252
Mining Method
mixed

Location

Location
309
Easting
505507
Northing
7575399
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
9 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
2
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a strong-grade, narrow intercept, which is not particularly material on its own, but contributes to the overall dataset.

Positive factors

  • Strong grade of 3.12 g/t Au, above the strong threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“3.12”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH059Twin Hills · goldGrade: 1.15Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH059
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.15
Grade Unit
g/t
Intercept
1 m
From
260 m
To
261 m
Hole Depth
366.8 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH059:260-261
Mining Method
mixed

Location

Location
309
Easting
505507
Northing
7575399
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
9 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade, narrow intercept, which is not particularly material on its own.

Positive factors

  • Moderate grade of 1.15 g/t Au, above the moderate threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“1.15”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH059Twin Hills · goldGrade: 0.61Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
TNDH059
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.61
Grade Unit
g/t
Intercept
4 m
From
288 m
To
292 m
Hole Depth
366.8 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH059:288-292
Mining Method
mixed

Location

Location
309
Easting
505507
Northing
7575399
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
9 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.61 g/t Au, below the moderate threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.61”

Context: 4.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH059Twin Hills · goldGrade: 0.41Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH059
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.41
Grade Unit
g/t
Intercept
1 m
From
307 m
To
308 m
Hole Depth
366.8 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH059:307-308
Mining Method
mixed

Location

Location
309
Easting
505507
Northing
7575399
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
9 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.41 g/t Au, at the weak threshold for epithermal deposits.
  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.41”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH059Twin Hills · goldGrade: 1.33Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH059
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
1.33
Grade Unit
g/t
Intercept
1 m
From
334 m
To
335 m
Hole Depth
366.8 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH059:334-335
Mining Method
mixed

Location

Location
309
Easting
505507
Northing
7575399
CRS
MGA Zone 55 GDA94
Elevation
253 m
Azimuth
9 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a moderate-grade, narrow intercept, which is not particularly material on its own.

Positive factors

  • Moderate grade of 1.33 g/t Au, above the moderate threshold for epithermal deposits.

Negative factors

  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“1.33”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH060Twin Hills · goldGrade: 0.61Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TNDH060
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.61
Grade Unit
g/t
Intercept
2 m
From
229 m
To
231 m
Hole Depth
360.4 m
Intercept Depth
229 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH060:229-231
Mining Method
mixed

Location

Location
309
Easting
505389
Northing
7575353
CRS
MGA Zone 55 GDA94
Elevation
254 m
Azimuth
10 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.61 g/t Au, below the moderate threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.61”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH060Twin Hills · goldGrade: 0.44Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TNDH060
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.44
Grade Unit
g/t
Intercept
1 m
From
247 m
To
248 m
Hole Depth
360.4 m
Intercept Depth
229 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH060:247-248
Mining Method
mixed

Location

Location
309
Easting
505389
Northing
7575353
CRS
MGA Zone 55 GDA94
Elevation
254 m
Azimuth
10 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade, narrow intercept, which is not particularly material on its own.

Negative factors

  • Low grade of 0.44 g/t Au, at the weak threshold for epithermal deposits.
  • Very narrow intercept length of 1m.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.44”

Context: 1.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH060Twin Hills · goldGrade: 0.36Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
TNDH060
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.36
Grade Unit
g/t
Intercept
4 m
From
257 m
To
261 m
Hole Depth
360.4 m
Intercept Depth
229 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH060:257-261
Mining Method
mixed

Location

Location
309
Easting
505389
Northing
7575353
CRS
MGA Zone 55 GDA94
Elevation
254 m
Azimuth
10 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Reasoning: This is a low-grade intercept, below the weak threshold for epithermal deposits, and not particularly material.

Negative factors

  • Low grade of 0.36 g/t Au, below the weak threshold for epithermal deposits.
  • True width is not known, which may overstate the actual thickness.

Evidence · table

“0.36”

Context: 4.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: The document explicitly states that 'true widths are not known'.

Evidence · text

“true widths are not known”
TNDH060Twin Hills · goldGrade: 0.59Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
TNDH060
Project
Twin Hills
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
GBM

Geometry

Grade
0.59
Grade Unit
g/t
Intercept
4 m
From
267 m
To
271 m
Hole Depth
360.4 m
Intercept Depth
229 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
TNDH060:267-271
Mining Method
mixed

Location

Location
309
Easting
505389
Northing
7575353
CRS
MGA Zone 55 GDA94
Elevation
254 m
Azimuth
10 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS and Intertek
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.4
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
4 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-11-08T00:00:00.000Z

Negative factors

  • Low grade of 0.59 g/t Au, at the weak threshold for epithermal deposits.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.