First Atlantic Nickel & Cobalt Attends Critical Minerals Briefing on Capitol Hill, Highlighting New Cerium Refining Technology That Extracted 98% of the Nickel and 82% of the Cobalt From Pipestone XL Awaruite (Ni-Fe-Co Alloy) in 20 Minutes Without Smelting, in Columbia University Research Funded by the U.S. Department of Energy's ARPA-E MINER Program
Original announcement by globenewswire on
- Company
- First Atlantic Nickel & Cobalt Corp.
- Ticker
- FAN
- Exchange
- Unavailable
- Region
- Newfoundland and Labrador
- Primary commodity
- Nickel
- Secondary commodities
- Cobalt
- Document categories
- Metallurgy
- Extracted
- 2026-11-19 12:37:10 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
First Atlantic Nickel & Cobalt highlights peer-reviewed Columbia University research demonstrating a new cerium-based refining technology. The process extracted 98% of nickel and 82% of cobalt from Pipestone XL awaruite concentrate in just 20 minutes without requiring smelting or sulfuric acid pretreatment.
Reasoning: The announcement reports breakthrough laboratory-scale metallurgical results for a new refining technology that significantly improves nickel and cobalt extraction efficiency from the company's specific ore type (awaruite) compared to traditional sulfides.
Positive factors
- High nickel recovery (98%) in very short time (20 mins)
- Eliminates need for smelting and sulfuric acid pretreatment
- Closed-loop cerium recycling demonstrated
- Outperforms traditional nickel sulfide concentrates in extraction efficiency
Negative factors
- Results are from laboratory-scale batch tests
- Continuous operation and commercial scale not yet demonstrated
- Cerium losses and downstream recovery not yet demonstrated
Facts used in scoring: 8
Classification and evidence
High Recoverypositive
Recovery at or above the exceptional band for the commodity and processing route.
Why it applies: 98% nickel recovery is exceptional for the cerium refining process.
Evidence · text
“extracted 98% of the nickel and 82% of the cobalt”
Bench Scale Onlynegative
Only preliminary bench tests completed — no locked-cycle or pilot work.
Why it applies: The disclosure states these were batch tests at laboratory scale.
Evidence · text
“The tests were batch tests at laboratory scale.”
Mill Routeneutral
Processing via mill or concentrator (CIL, CIP, tank leach, flotation).
Why it applies: the document describes a flotation route ("flotation")
POX/BIOX Routeneutral
Pressure or bio-oxidation for refractory ore — high CAPEX and OPEX.
Why it applies: the document describes a pox_biox route ("roasting")
Multi-Domain Testedpositive
Variability across ore domains (oxide, transition, fresh) has been addressed.
Why it applies: 2 distinct composites were tested
Extracted facts
Stored fact records: 8. Some facts used in scoring do not have a stored record.
Metallurgical Results (8)
batch testsPipestone XL Nickel-Cobalt Alloy Project · nickelRecovery: 98 %View all detailsHide details
Identity
- Project
- Pipestone XL Nickel-Cobalt Alloy Project
- Commodity
- nickel
- Region
- canada_nl
- Reported Region
- Newfoundland and Labrador
- Ticker
- FAN
Test Work
- Program Status
- preliminary
- Test Type
- batch tests
- Processing Route
- cerium refining technology
- Sample
- Pipestone XL awaruite concentrate (AWC)
- Leach Time
- 0.333 hours
Recovery
- Recovery
- 98 %
Lab
- Laboratory
- Columbia University
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-11-19T00:00:00.000Z
Reasoning: Exceptional nickel recovery achieved in a very short timeframe using a novel process.
Positive factors
- 98% recovery is exceptional
- Extremely fast kinetics (20 mins)
Negative factors
- Laboratory scale only
Evidence · text
“extracted 98% of the nickel and 82% of the cobalt in 20 minutes from awaruite (Ni-Fe-Co alloy) concentrate”
Tags used in scoring
High Recoverypositive
Recovery at or above the exceptional band for the commodity and processing route.
Why it applies: 98% is at or above the exceptional band (90%)
batch testsPipestone XL Nickel-Cobalt Alloy Project · cobaltRecovery: 82 %View all detailsHide details
Identity
- Project
- Pipestone XL Nickel-Cobalt Alloy Project
- Commodity
- cobalt
- Region
- canada_nl
- Reported Region
- Newfoundland and Labrador
- Ticker
- FAN
Test Work
- Program Status
- preliminary
- Test Type
- batch tests
- Processing Route
- cerium refining technology
- Sample
- Pipestone XL awaruite concentrate (AWC)
- Leach Time
- 0.333 hours
Recovery
- Recovery
- 82 %
Lab
- Laboratory
- Columbia University
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-11-19T00:00:00.000Z
Reasoning: Significant cobalt recovery achieved in a novel, fast process.
Positive factors
- Strong cobalt recovery alongside nickel
Negative factors
- Laboratory scale only
Evidence · text
“extracted 98% of the nickel and 82% of the cobalt in 20 minutes”
batch testsPipestone XL Nickel-Cobalt Alloy Project · nickelRecovery: 77 %View all detailsHide details
Identity
- Project
- Pipestone XL Nickel-Cobalt Alloy Project
- Commodity
- nickel
- Region
- canada_nl
- Reported Region
- Newfoundland and Labrador
- Ticker
- FAN
Test Work
- Program Status
- preliminary
- Test Type
- batch tests
- Processing Route
- cerium refining technology
- Sample
- Pipestone XL pre-flotation magnetic-only concentrate (AW-PF)
- Leach Time
- 0.333 hours
Recovery
- Recovery
- 77 %
Lab
- Laboratory
- Columbia University
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-11-19T00:00:00.000Z
Reasoning: Lower nickel recovery for the pre-flotation concentrate compared to the AWC.
Negative factors
- Lower recovery compared to AWC
Evidence · table
“77 %”
Context: Pipestone XL pre-flotation magnetic-only concentrate (AW-PF)
batch testsTamarack · nickelRecovery: 82.5 %View all detailsHide details
Identity
- Project
- Tamarack
- Commodity
- nickel
- Ticker
- FAN
Test Work
- Program Status
- preliminary
- Test Type
- batch tests
- Processing Route
- cerium refining technology
- Sample
- Tamarack sulfide concentrate 1 (SMSU-C)
- Leach Time
- 1 hours
Recovery
- Recovery
- 82.5 %
Lab
- Laboratory
- Columbia University
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-11-19T00:00:00.000Z
Reasoning: Standard sulfide concentrate shows lower efficiency and slower kinetics compared to the awaruite concentrate.
Negative factors
- Requires 3x more time than awaruite
- Lower recovery than awaruite
Evidence · table
“82.5%”
Context: Tamarack sulfide concentrate 1 (SMSU-C)
batch testsTamarack · nickelRecovery: 66.1 %View all detailsHide details
Identity
- Project
- Tamarack
- Commodity
- nickel
- Ticker
- FAN
Test Work
- Program Status
- preliminary
- Test Type
- batch tests
- Processing Route
- cerium refining technology
- Sample
- Tamarack sulfide concentrate 2 (CGO-C)
- Leach Time
- 1 hours
Recovery
- Recovery
- 66.1 %
Lab
- Laboratory
- Columbia University
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-11-19T00:00:00.000Z
Reasoning: Poor nickel recovery and slow kinetics for this sulfide sample.
Negative factors
- Low recovery
- Slow kinetics
Evidence · table
“66.1%”
Context: Tamarack sulfide concentrate 2 (CGO-C)
Tags used in scoring
Low Recoverynegative
Recovery below the weak band for the commodity and processing route.
Why it applies: 66.1% is below the weak band (75%)
batch testsTamarack · nickelRecovery: 70.5 %View all detailsHide details
Identity
- Project
- Tamarack
- Commodity
- nickel
- Ticker
- FAN
Test Work
- Program Status
- preliminary
- Test Type
- batch tests
- Processing Route
- cerium refining technology
- Sample
- Tamarack high-magnesium sulfide 1 (SMSU-HM)
- Leach Time
- 1 hours
Recovery
- Recovery
- 70.5 %
Lab
- Laboratory
- Columbia University
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-11-19T00:00:00.000Z
Reasoning: Moderate recovery but slow kinetics compared to awaruite.
Negative factors
- Slow kinetics
Evidence · table
“70.5%”
Context: Tamarack high-magnesium sulfide 1 (SMSU-HM)
Tags used in scoring
Low Recoverynegative
Recovery below the weak band for the commodity and processing route.
Why it applies: 70.5% is below the weak band (75%)
batch testsTamarack · nickelRecovery: 59 %View all detailsHide details
Identity
- Project
- Tamarack
- Commodity
- nickel
- Ticker
- FAN
Test Work
- Program Status
- preliminary
- Test Type
- batch tests
- Processing Route
- cerium refining technology
- Sample
- Tamarack high-magnesium sulfide 2 (CGO-HM)
- Leach Time
- 1 hours
Recovery
- Recovery
- 59 %
Lab
- Laboratory
- Columbia University
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-11-19T00:00:00.000Z
Reasoning: Low nickel recovery and slow kinetics for this high-magnesium sulfide sample.
Negative factors
- Low recovery
- Slow kinetics
Evidence · table
“59%”
Context: Tamarack high-magnesium sulfide 2 (CGO-HM)
Tags used in scoring
Low Recoverynegative
Recovery below the weak band for the commodity and processing route.
Why it applies: 59% is below the weak band (75%)
batch testsTamarack · nickelRecovery: 84 %View all detailsHide details
Identity
- Project
- Tamarack
- Commodity
- nickel
- Ticker
- FAN
Test Work
- Program Status
- preliminary
- Test Type
- batch tests
- Processing Route
- cerium refining technology
- Sample
- Tamarack high-magnesium sulfide 1 (SMSU-HM), acid pretreated
- Leach Time
- 1 hours
Recovery
- Recovery
- 84 %
Lab
- Laboratory
- Columbia University
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-11-19T00:00:00.000Z
Reasoning: Acid pretreatment improves recovery but adds a processing step and slow kinetics compared to awaruite.
Positive factors
- High recovery achieved with acid pretreatment
Negative factors
- Requires sulfuric acid pretreatment
- Slow kinetics
Evidence · table
“84%”
Context: Tamarack high-magnesium sulfide 1 (SMSU-HM), acid pretreated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.