Fireweed confirms high-grade Tom East zone

Original announcement by miningnewsnorth on

Company
Fireweed Metals Corp.
Ticker
Unavailable
Exchange
Unavailable
Region
Yukon
Primary commodity
Zinc
Secondary commodities
Lead, Silver, Germanium, Gallium
Document categories
Drill results, Resource update
Extracted
2026-10-29 21:20:18 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Fireweed Metals Corp. has reported high-grade zinc-lead-silver drill results from its Macpass project in the Yukon, specifically targeting the Tom East zone. The infill drilling confirmed mineralization continuity with notable intercepts, including a 17m true width at 5.73% Zn in hole TS26-007.

Reasoning: The release reports high-grade drill intercepts at the Tom East zone that confirm continuity and include significant true widths and high-grade sub-intervals.

Positive factors

  • High-grade zinc-lead-silver intercepts confirmed
  • True width disclosed for key intercepts
  • Continuity of mineralization confirmed via infill drilling
  • Presence of high-grade sub-intervals

Facts used in scoring: 12

Atlas analysis — Fireweed Metals Corp.: Fireweed confirms high-grade Tom East zone. 5.73 % over 17 m; 3.36 % over 19 m; 10.65 % over 3.8 m

Classification and evidence

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: Key intercepts in TS26-007 and TS26-005 explicitly state true width.

Evidence · text

“17 meters true width”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: The program is described as infill drilling at Tom East to test continuity.

Evidence · text

“infill drilling at Tom East”

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The sub-interval in TS26-007 (10.71% Zn, 25.27% Pb, 313 g/t Ag) is exceptionally high grade.

Evidence · text

“averaging 10.71% zinc, 25.27% lead, and 313 g/t silver”

Extracted facts

Stored fact records: 12. Some facts used in scoring do not have a stored record.

Drill Results (12)

TS26-007Macpass · zincGrade: 5.73Grade Unit: %Intercept: 17 mView all details
Link to this fact

Identity

Hole ID
TS26-007
Project
Macpass
Commodity
zinc
Region
canada_yt
Reported Region
canada_yt

Geometry

Grade
5.73
Grade Unit
%
Intercept
17 m
True Width
17 m
From
191.44 m
To
208.44 m
Intercept Depth
191.44 m

Classification

Program
resource
Sample Type
drill
Group ID
TS26-007:191.44-208.44

Location

Location
East Zone
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: High-grade zinc intercept with stated true width.

Positive factors

  • Strong zinc grade
  • True width disclosed

Evidence · text

“17 meters true width averaging 5.73% zinc, 10.87% lead, and 143.5 g/t silver from a depth of 191.44 meters in hole TS26-007”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

TS26-007Macpass · leadGrade: 10.87Grade Unit: %Intercept: 17 mView all details
Link to this fact

Identity

Hole ID
TS26-007
Project
Macpass
Commodity
lead
Region
canada_yt
Reported Region
canada_yt

Geometry

Grade
10.87
Grade Unit
%
Intercept
17 m
True Width
17 m
From
191.44 m
To
208.44 m
Intercept Depth
191.44 m

Classification

Program
resource
Sample Type
drill
Group ID
TS26-007:191.44-208.44

Location

Location
East Zone
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: High-grade lead intercept.

Positive factors

  • Strong lead grade

Evidence · text

“17 meters true width averaging 5.73% zinc, 10.87% lead, and 143.5 g/t silver from a depth of 191.44 meters in hole TS26-007”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

TS26-007Macpass · silverGrade: 143.5Grade Unit: g/tIntercept: 17 mView all details
Link to this fact

Identity

Hole ID
TS26-007
Project
Macpass
Commodity
silver
Region
canada_yt
Reported Region
canada_yt

Geometry

Grade
143.5
Grade Unit
g/t
Intercept
17 m
True Width
17 m
From
191.44 m
To
208.44 m
Intercept Depth
191.44 m

Classification

Program
resource
Sample Type
drill
Group ID
TS26-007:191.44-208.44

Location

Location
East Zone
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: High-grade silver intercept.

Positive factors

  • Strong silver grade

Evidence · text

“17 meters true width averaging 5.73% zinc, 10.87% lead, and 143.5 g/t silver from a depth of 191.44 meters in hole TS26-007”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

TS26-007Macpass · zincGrade: 10.71Grade Unit: %Intercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
TS26-007
Project
Macpass
Commodity
zinc
Region
canada_yt
Reported Region
canada_yt

Geometry

Grade
10.71
Grade Unit
%
Intercept
3.5 m
True Width
3.5 m

Classification

Program
resource
Sample Type
drill
Group ID
TS26-007:sub-interval

Location

Location
East Zone
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Very high grade sub-interval.

Positive factors

  • Bonanza grade zinc

Evidence · text

“including 3.5 meters true width averaging 10.71% zinc, 25.27% lead, and 313 g/t silver”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

TS26-007Macpass · leadGrade: 25.27Grade Unit: %Intercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
TS26-007
Project
Macpass
Commodity
lead
Region
canada_yt
Reported Region
canada_yt

Geometry

Grade
25.27
Grade Unit
%
Intercept
3.5 m
True Width
3.5 m

Classification

Program
resource
Sample Type
drill
Group ID
TS26-007:sub-interval

Location

Location
East Zone
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Very high grade sub-interval.

Positive factors

  • Bonanza grade lead

Evidence · text

“including 3.5 meters true width averaging 10.71% zinc, 25.27% lead, and 313 g/t silver”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

TS26-007Macpass · silverGrade: 313Grade Unit: g/tIntercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
TS26-007
Project
Macpass
Commodity
silver
Region
canada_yt
Reported Region
canada_yt

Geometry

Grade
313
Grade Unit
g/t
Intercept
3.5 m
True Width
3.5 m

Classification

Program
resource
Sample Type
drill
Group ID
TS26-007:sub-interval

Location

Location
East Zone
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Very high grade sub-interval.

Positive factors

  • Bonanza grade silver

Evidence · text

“including 3.5 meters true width averaging 10.71% zinc, 25.27% lead, and 313 g/t silver”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

TS26-005Macpass · zincGrade: 3.36Grade Unit: %Intercept: 19 mView all details
Link to this fact

Identity

Hole ID
TS26-005
Project
Macpass
Commodity
zinc
Region
canada_yt
Reported Region
canada_yt

Geometry

Grade
3.36
Grade Unit
%
Intercept
19 m
True Width
19 m
From
163.17 m
To
182.17 m
Intercept Depth
163.17 m

Classification

Program
resource
Sample Type
drill
Group ID
TS26-005:163.17-182.17

Location

Location
East Zone
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Solid zinc intercept with stated true width.

Positive factors

  • Strong zinc grade
  • True width disclosed

Evidence · text

“19 meters true width averaging 3.36% zinc, 4.49% lead, and 61.4 g/t silver from 163.17 meters in TS26-005”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 19

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

TS26-005Macpass · leadGrade: 4.49Grade Unit: %Intercept: 19 mView all details
Link to this fact

Identity

Hole ID
TS26-005
Project
Macpass
Commodity
lead
Region
canada_yt
Reported Region
canada_yt

Geometry

Grade
4.49
Grade Unit
%
Intercept
19 m
True Width
19 m
From
163.17 m
To
182.17 m
Intercept Depth
163.17 m

Classification

Program
resource
Sample Type
drill
Group ID
TS26-005:163.17-182.17

Location

Location
East Zone
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Solid lead intercept.

Positive factors

  • Moderate lead grade

Evidence · text

“19 meters true width averaging 3.36% zinc, 4.49% lead, and 61.4 g/t silver from 163.17 meters in TS26-005”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 19

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

TS26-005Macpass · silverGrade: 61.4Grade Unit: g/tIntercept: 19 mView all details
Link to this fact

Identity

Hole ID
TS26-005
Project
Macpass
Commodity
silver
Region
canada_yt
Reported Region
canada_yt

Geometry

Grade
61.4
Grade Unit
g/t
Intercept
19 m
True Width
19 m
From
163.17 m
To
182.17 m
Intercept Depth
163.17 m

Classification

Program
resource
Sample Type
drill
Group ID
TS26-005:163.17-182.17

Location

Location
East Zone
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Solid silver intercept.

Positive factors

  • Moderate silver grade

Evidence · text

“19 meters true width averaging 3.36% zinc, 4.49% lead, and 61.4 g/t silver from 163.17 meters in TS26-005”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 19

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

TS26-005Macpass · zincGrade: 10.65Grade Unit: %Intercept: 3.8 mView all details
Link to this fact

Identity

Hole ID
TS26-005
Project
Macpass
Commodity
zinc
Region
canada_yt
Reported Region
canada_yt

Geometry

Grade
10.65
Grade Unit
%
Intercept
3.8 m
True Width
3.8 m

Classification

Program
resource
Sample Type
drill
Group ID
TS26-005:sub-interval

Location

Location
East Zone
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: High-grade sub-interval.

Positive factors

  • Strong zinc grade

Evidence · text

“including 3.8 meters true width averaging 10.65% zinc, 12.08% lead, and 173.8 g/t silver”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

TS26-005Macpass · leadGrade: 12.08Grade Unit: %Intercept: 3.8 mView all details
Link to this fact

Identity

Hole ID
TS26-005
Project
Macpass
Commodity
lead
Region
canada_yt
Reported Region
canada_yt

Geometry

Grade
12.08
Grade Unit
%
Intercept
3.8 m
True Width
3.8 m

Classification

Program
resource
Sample Type
drill
Group ID
TS26-005:sub-interval

Location

Location
East Zone
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: High-grade sub-interval.

Positive factors

  • Strong lead grade

Evidence · text

“including 3.8 meters true width averaging 10.65% zinc, 12.08% lead, and 173.8 g/t silver”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

TS26-005Macpass · silverGrade: 173.8Grade Unit: g/tIntercept: 3.8 mView all details
Link to this fact

Identity

Hole ID
TS26-005
Project
Macpass
Commodity
silver
Region
canada_yt
Reported Region
canada_yt

Geometry

Grade
173.8
Grade Unit
g/t
Intercept
3.8 m
True Width
3.8 m

Classification

Program
resource
Sample Type
drill
Group ID
TS26-005:sub-interval

Location

Location
East Zone
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QA/QC Methods
blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: High-grade sub-interval.

Positive factors

  • Strong silver grade

Evidence · text

“including 3.8 meters true width averaging 10.65% zinc, 12.08% lead, and 173.8 g/t silver”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.