Awalé Connects Charger 1 and Charger 2 – Extending Gold Mineralization Across 300 Metres of Strike, Including 8.7 g/t Gold over 25 Metres and 7.0 g/t Gold over 28 Metres
Original announcement by prospectors_exchange on
- Company
- Awalé Resources Limited
- Ticker
- ARIC
- Exchange
- Unavailable
- Region
- Côte d’Ivoire
- Primary commodity
- Unavailable
- Secondary commodities
- None reported
- Document categories
- Drill results
- Extracted
- 2026-10-27 13:05:09 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Awalé Resources announced new step-out diamond drilling results at its Odienné Project, successfully connecting the Charger 1 and Charger 2 zones. The drilling extended high-grade gold mineralization across 300 metres of strike and 400 metres vertically, with estimated true widths up to 34 metres, and remains open at depth. Key intercepts include 8.7 g/t gold over 25 metres and 7.0 g/t gold over 28 metres, supporting continued growth potential.
Reasoning: The step-out drilling successfully connected Charger 1 and Charger 2, extending high-grade gold mineralization over a significant strike length and depth with notable intercepts like 8.7 g/t gold over 25 metres and 7.0 g/t gold over 28 metres, indicating strong growth potential for the project.
Positive factors
- High-grade gold intercepts
- Significant width of mineralization
- Extension of mineralization along strike (300m) and vertically (400m)
- Merging of Charger 1 and Charger 2 zones
- Mineralization remains open at depth and down-plunge
- True widths estimated up to 34m
- QA/QC procedures disclosed
- Certified laboratory used
- Qualified Person sign-off
- Compositing parameters disclosed
Facts used in scoring: 160

Extracted facts
Stored fact records: 160. Some facts used in scoring do not have a stored record.
Drill Results (160)
CHDD0027Charger · goldGrade: 1.14Grade Unit: g/tIntercept: 3.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.14
- Grade Unit
- g/t
- Intercept
- 3.5 m
- True Width
- 2.45 m
- From
- 19 m
- To
- 22.5 m
- Hole Depth
- 164.3 m
- Intercept Depth
- 19 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- CHDD0027:19-22.5
- Mining Method
- unknown
Location
- Easting
- 647879
- Northing
- 1032342
- Elevation
- 469.5 m
- Azimuth
- 313.1 °
- Dip
- -56 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t Au
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Moderate gold grade over a narrow width, contributing to overall mineralization extension.
Evidence · table
“1.14”
Context: 3.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
CHDD0027Charger · copperGrade: 0.01Grade Unit: %Intercept: 3.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 3.5 m
- True Width
- 2.45 m
- From
- 19 m
- To
- 22.5 m
- Hole Depth
- 164.3 m
- Intercept Depth
- 19 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- CHDD0027:19-22.5
- Mining Method
- unknown
Location
- Easting
- 647879
- Northing
- 1032342
- Elevation
- 469.5 m
- Azimuth
- 313.1 °
- Dip
- -56 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t Au
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Trace copper grade, not significant.
Evidence · table
“0.01”
Context: 3.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
CHDD0027Charger · silverGrade: 0.12Grade Unit: g/tIntercept: 3.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.12
- Grade Unit
- g/t
- Intercept
- 3.5 m
- True Width
- 2.45 m
- From
- 19 m
- To
- 22.5 m
- Hole Depth
- 164.3 m
- Intercept Depth
- 19 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- CHDD0027:19-22.5
- Mining Method
- unknown
Location
- Easting
- 647879
- Northing
- 1032342
- Elevation
- 469.5 m
- Azimuth
- 313.1 °
- Dip
- -56 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.5
- Cutoff Unit
- g/t Au
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Trace silver grade, not significant.
Evidence · table
“0.12”
Context: 3.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
CHDD0027Charger · molybdenumGrade: 2Grade Unit: ppmIntercept: 3.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 2
- Grade Unit
- ppm
- Intercept
- 3.5 m
- From
- 19 m
- To
- 22.5 m
- Intercept Depth
- 19 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:19-22.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 2 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“2”
Context: CHDD0027
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 6.45Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 6.45
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 51.5 m
- To
- 52 m
- Intercept Depth
- 51.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:51.5-52
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 6.45 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.2 g/t·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 6.45 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.45”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 51.5 m
- To
- 52 m
- Intercept Depth
- 51.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:51.5-52
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.24Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.24
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 51.5 m
- To
- 52 m
- Intercept Depth
- 51.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:51.5-52
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.24 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.24 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.24”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 2Grade Unit: ppmIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 2
- Grade Unit
- ppm
- Intercept
- 0.5 m
- From
- 51.5 m
- To
- 52 m
- Intercept Depth
- 51.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:51.5-52
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 2 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“2”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 1.65Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.65
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 60.5 m
- To
- 61.5 m
- Intercept Depth
- 60.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:60.5-61.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.65 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.6 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.65”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.02Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 1 m
- From
- 60.5 m
- To
- 61.5 m
- Intercept Depth
- 60.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:60.5-61.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.02 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.23Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 60.5 m
- To
- 61.5 m
- Intercept Depth
- 60.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:60.5-61.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.23 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.2 g/t·m is below.
Negative factors
- 0.23 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.23”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 2Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 2
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 60.5 m
- To
- 61.5 m
- Intercept Depth
- 60.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:60.5-61.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 2 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“2”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 1.1Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.1
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 69.5 m
- To
- 70 m
- Intercept Depth
- 69.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:69.5-70
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.1 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.10”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.02Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 69.5 m
- To
- 70 m
- Intercept Depth
- 69.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:69.5-70
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.02 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.22Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.22
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 69.5 m
- To
- 70 m
- Intercept Depth
- 69.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:69.5-70
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.22 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.22 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.22”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 2Grade Unit: ppmIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 2
- Grade Unit
- ppm
- Intercept
- 0.5 m
- From
- 69.5 m
- To
- 70 m
- Intercept Depth
- 69.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:69.5-70
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 2 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“2”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 1.1Grade Unit: g/tIntercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.1
- Grade Unit
- g/t
- Intercept
- 2.5 m
- From
- 78 m
- To
- 80.5 m
- Intercept Depth
- 78 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:78-80.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.1 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.8 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.10”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.01Grade Unit: %Intercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 2.5 m
- From
- 78 m
- To
- 80.5 m
- Intercept Depth
- 78 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:78-80.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.09Grade Unit: g/tIntercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 2.5 m
- From
- 78 m
- To
- 80.5 m
- Intercept Depth
- 78 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:78-80.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.2 g/t·m is below.
Negative factors
- 0.09 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 2Grade Unit: ppmIntercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 2
- Grade Unit
- ppm
- Intercept
- 2.5 m
- From
- 78 m
- To
- 80.5 m
- Intercept Depth
- 78 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:78-80.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 2 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“2”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 4.48Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 4.48
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 80 m
- To
- 80.5 m
- Intercept Depth
- 80 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:80-80.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 4.48 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.2 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 4.48 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“4.48”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.01Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 80 m
- To
- 80.5 m
- Intercept Depth
- 80 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:80-80.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.16Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.16
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 80 m
- To
- 80.5 m
- Intercept Depth
- 80 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:80-80.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.16 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.16 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.16”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 2Grade Unit: ppmIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 2
- Grade Unit
- ppm
- Intercept
- 0.5 m
- From
- 80 m
- To
- 80.5 m
- Intercept Depth
- 80 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:80-80.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 2 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“2”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 3.79Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 3.79
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 114 m
- To
- 115 m
- Intercept Depth
- 114 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:114-115
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 3.79 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.8 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 3.79 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.79”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.01Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 1 m
- From
- 114 m
- To
- 115 m
- Intercept Depth
- 114 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:114-115
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.21Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 114 m
- To
- 115 m
- Intercept Depth
- 114 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:114-115
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.21 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.2 g/t·m is below.
Negative factors
- 0.21 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.21”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 2Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 2
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 114 m
- To
- 115 m
- Intercept Depth
- 114 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:114-115
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 2 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“2”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0028Charger · goldGrade: 0.81Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0028
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.81
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 96 m
- To
- 97 m
- Intercept Depth
- 96 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0028:96-97
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.81 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.81”
Context: CHDD0028
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0028Charger · copperGrade: 0.01Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0028
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 1 m
- From
- 96 m
- To
- 97 m
- Intercept Depth
- 96 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0028:96-97
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: CHDD0028
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0028Charger · silverGrade: 0.09Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0028
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 96 m
- To
- 97 m
- Intercept Depth
- 96 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0028:96-97
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.09 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: CHDD0028
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0028Charger · molybdenumGrade: 3Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0028
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 3
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 96 m
- To
- 97 m
- Intercept Depth
- 96 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0028:96-97
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 3 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“3”
Context: CHDD0028
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 0.8Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.8
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 130 m
- To
- 131 m
- Intercept Depth
- 130 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:130-131
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.8 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.80”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.01Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 1 m
- From
- 130 m
- To
- 131 m
- Intercept Depth
- 130 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:130-131
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.09Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 130 m
- To
- 131 m
- Intercept Depth
- 130 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:130-131
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.09 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 3Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 3
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 130 m
- To
- 131 m
- Intercept Depth
- 130 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:130-131
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 3 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“3”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0030Charger · goldGrade: 0.62Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0030
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.62
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 233 m
- To
- 234 m
- Intercept Depth
- 233 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0030:233-234
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.62 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.62”
Context: CHDD0030
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0030Charger · copperGrade: 0.55Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0030
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.55
- Grade Unit
- %
- Intercept
- 1 m
- From
- 233 m
- To
- 234 m
- Intercept Depth
- 233 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0030:233-234
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.55 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.6 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.55”
Context: CHDD0030
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0030Charger · silverGrade: 13.84Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0030
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 13.84
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 233 m
- To
- 234 m
- Intercept Depth
- 233 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0030:233-234
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 13.84 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 13.8 g/t·m is below.
Negative factors
- 13.84 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“13.84”
Context: CHDD0030
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0030Charger · molybdenumGrade: 4Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0030
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 4
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 233 m
- To
- 234 m
- Intercept Depth
- 233 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0030:233-234
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 4 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“4”
Context: CHDD0030
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0033Charger · goldGrade: 0.57Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0033
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.57
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 3.5 m
- To
- 5 m
- Intercept Depth
- 3.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0033:3.5-5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.57 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.9 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.57”
Context: CHDD0033
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0033Charger · copperGrade: 0.02Grade Unit: %Intercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0033
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 1.5 m
- From
- 3.5 m
- To
- 5 m
- Intercept Depth
- 3.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0033:3.5-5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.02 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: CHDD0033
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0033Charger · silverGrade: 1.36Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0033
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.36
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 3.5 m
- To
- 5 m
- Intercept Depth
- 3.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0033:3.5-5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.36 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.0 g/t·m is below.
Negative factors
- 1.36 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.36”
Context: CHDD0033
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0033Charger · molybdenumGrade: 1Grade Unit: ppmIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0033
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1
- Grade Unit
- ppm
- Intercept
- 1.5 m
- From
- 3.5 m
- To
- 5 m
- Intercept Depth
- 3.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0033:3.5-5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 1 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“1”
Context: CHDD0033
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 1.34Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.34
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 9.5 m
- To
- 12.5 m
- Intercept Depth
- 9.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:9.5-12.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.34 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 4.0 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.34”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.02Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 3 m
- From
- 9.5 m
- To
- 12.5 m
- Intercept Depth
- 9.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:9.5-12.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.02 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.74Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.74
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 9.5 m
- To
- 12.5 m
- Intercept Depth
- 9.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:9.5-12.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.74 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.2 g/t·m is below.
Negative factors
- 0.74 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.74”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 1Grade Unit: ppmIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1
- Grade Unit
- ppm
- Intercept
- 3 m
- From
- 9.5 m
- To
- 12.5 m
- Intercept Depth
- 9.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:9.5-12.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 1 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“1”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0033Charger · goldGrade: 1.95Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0033
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.95
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 9.5 m
- To
- 11 m
- Intercept Depth
- 9.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0033:9.5-11
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.95 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.9 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.95”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0033Charger · copperGrade: 0.02Grade Unit: %Intercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0033
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 1.5 m
- From
- 9.5 m
- To
- 11 m
- Intercept Depth
- 9.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0033:9.5-11
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.02 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0033Charger · silverGrade: 0.93Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0033
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.93
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 9.5 m
- To
- 11 m
- Intercept Depth
- 9.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0033:9.5-11
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.93 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.4 g/t·m is below.
Negative factors
- 0.93 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.93”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0033Charger · molybdenumGrade: 1Grade Unit: ppmIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0033
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1
- Grade Unit
- ppm
- Intercept
- 1.5 m
- From
- 9.5 m
- To
- 11 m
- Intercept Depth
- 9.5 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0033:9.5-11
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 1 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“1”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 0.76Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.76
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 43 m
- To
- 43.5 m
- Intercept Depth
- 43 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:43-43.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.76 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.76”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.03Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 43 m
- To
- 43.5 m
- Intercept Depth
- 43 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:43-43.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.03 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.03 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.03”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 1.96Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.96
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 43 m
- To
- 43.5 m
- Intercept Depth
- 43 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:43-43.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.96 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.0 g/t·m is below.
Negative factors
- 1.96 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.96”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 91Grade Unit: ppmIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 91
- Grade Unit
- ppm
- Intercept
- 0.5 m
- From
- 43 m
- To
- 43.5 m
- Intercept Depth
- 43 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:43-43.5
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 91 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“91”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 0.63Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.63
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 52 m
- To
- 53 m
- Intercept Depth
- 52 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:52-53
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.63 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.63”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.11Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.11
- Grade Unit
- %
- Intercept
- 1 m
- From
- 52 m
- To
- 53 m
- Intercept Depth
- 52 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:52-53
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.11 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.11 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.11”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 1.47Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.47
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 52 m
- To
- 53 m
- Intercept Depth
- 52 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:52-53
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.47 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.5 g/t·m is below.
Negative factors
- 1.47 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.47”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 1Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 52 m
- To
- 53 m
- Intercept Depth
- 52 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:52-53
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 1 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“1”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0034Charger · goldGrade: 0.53Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0034
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.53
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 165 m
- To
- 166 m
- Intercept Depth
- 165 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0034:165-166
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.53 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.53”
Context: CHDD0034
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0034Charger · copperGrade: 0.01Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0034
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 1 m
- From
- 165 m
- To
- 166 m
- Intercept Depth
- 165 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0034:165-166
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: CHDD0034
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0034Charger · silverGrade: 0.22Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0034
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.22
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 165 m
- To
- 166 m
- Intercept Depth
- 165 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0034:165-166
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.22 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.2 g/t·m is below.
Negative factors
- 0.22 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.22”
Context: CHDD0034
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0034Charger · molybdenumGrade: 2Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0034
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 2
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 165 m
- To
- 166 m
- Intercept Depth
- 165 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0034:165-166
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 2 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“2”
Context: CHDD0034
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 3.07Grade Unit: g/tIntercept: 15 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 3.07
- Grade Unit
- g/t
- Intercept
- 15 m
- From
- 173 m
- To
- 188 m
- Intercept Depth
- 173 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:173-188
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 3.07 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 46.0 g/t·m is moderate (grade alone is strong; the better of the two is used).
Positive factors
- 3.07 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.07”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.01Grade Unit: %Intercept: 15 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 15 m
- From
- 173 m
- To
- 188 m
- Intercept Depth
- 173 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:173-188
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.37Grade Unit: g/tIntercept: 15 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.37
- Grade Unit
- g/t
- Intercept
- 15 m
- From
- 173 m
- To
- 188 m
- Intercept Depth
- 173 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:173-188
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.37 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.5 g/t·m is below.
Negative factors
- 0.37 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.37”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 3Grade Unit: ppmIntercept: 15 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 3
- Grade Unit
- ppm
- Intercept
- 15 m
- From
- 173 m
- To
- 188 m
- Intercept Depth
- 173 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:173-188
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 3 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“3”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0034Charger · goldGrade: 8.11Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- CHDD0034
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 8.11
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 174 m
- To
- 177 m
- Intercept Depth
- 174 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0034:174-177
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 8.11 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 24.3 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 8.11 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“8.11”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0034Charger · copperGrade: 0.01Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- CHDD0034
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 3 m
- From
- 174 m
- To
- 177 m
- Intercept Depth
- 174 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0034:174-177
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0034Charger · silverGrade: 0.58Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- CHDD0034
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.58
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 174 m
- To
- 177 m
- Intercept Depth
- 174 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0034:174-177
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.58 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.7 g/t·m is below.
Negative factors
- 0.58 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.58”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0034Charger · molybdenumGrade: 8Grade Unit: ppmIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- CHDD0034
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 8
- Grade Unit
- ppm
- Intercept
- 3 m
- From
- 174 m
- To
- 177 m
- Intercept Depth
- 174 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0034:174-177
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 8 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“8”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 0.55Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.55
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 195 m
- To
- 196 m
- Intercept Depth
- 195 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:195-196
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.55 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.55”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.04Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 1 m
- From
- 195 m
- To
- 196 m
- Intercept Depth
- 195 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:195-196
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.04 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.04 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.04”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.92Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.92
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 195 m
- To
- 196 m
- Intercept Depth
- 195 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:195-196
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.92 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.9 g/t·m is below.
Negative factors
- 0.92 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.92”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 2Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 2
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 195 m
- To
- 196 m
- Intercept Depth
- 195 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:195-196
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 2 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“2”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 0.97Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.97
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 232 m
- To
- 233 m
- Intercept Depth
- 232 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:232-233
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.97 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.0 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.97”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.01Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 1 m
- From
- 232 m
- To
- 233 m
- Intercept Depth
- 232 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:232-233
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.11Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.11
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 232 m
- To
- 233 m
- Intercept Depth
- 232 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:232-233
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.11 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.11 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.11”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 2Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 2
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 232 m
- To
- 233 m
- Intercept Depth
- 232 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:232-233
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 2 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“2”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0035Charger · goldGrade: 0.55Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0035
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.55
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 168 m
- To
- 169 m
- Intercept Depth
- 168 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0035:168-169
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.55 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.55”
Context: CHDD0035
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0035Charger · copperGrade: 0.01Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0035
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 1 m
- From
- 168 m
- To
- 169 m
- Intercept Depth
- 168 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0035:168-169
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: CHDD0035
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0035Charger · silverGrade: 0.15Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0035
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 168 m
- To
- 169 m
- Intercept Depth
- 168 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0035:168-169
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.15 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.15 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.15”
Context: CHDD0035
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0035Charger · molybdenumGrade: 4Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0035
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 4
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 168 m
- To
- 169 m
- Intercept Depth
- 168 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0035:168-169
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 4 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“4”
Context: CHDD0035
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 0.69Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.69
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 188 m
- To
- 189 m
- Intercept Depth
- 188 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:188-189
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.69 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.69”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.01Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 1 m
- From
- 188 m
- To
- 189 m
- Intercept Depth
- 188 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:188-189
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.31Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.31
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 188 m
- To
- 189 m
- Intercept Depth
- 188 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:188-189
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.31 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.3 g/t·m is below.
Negative factors
- 0.31 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.31”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 3Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 3
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 188 m
- To
- 189 m
- Intercept Depth
- 188 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:188-189
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 3 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“3”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0052Charger · goldGrade: 1.01Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0052
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.01
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 125 m
- To
- 126 m
- Intercept Depth
- 125 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0052:125-126
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.01 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.0 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.01”
Context: CHDD0052
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0052Charger · copperGrade: 0.01Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0052
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 1 m
- From
- 125 m
- To
- 126 m
- Intercept Depth
- 125 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0052:125-126
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: CHDD0052
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0052Charger · silverGrade: 0.27Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0052
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 125 m
- To
- 126 m
- Intercept Depth
- 125 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0052:125-126
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.27 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.3 g/t·m is below.
Negative factors
- 0.27 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.27”
Context: CHDD0052
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0052Charger · molybdenumGrade: 3Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0052
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 3
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 125 m
- To
- 126 m
- Intercept Depth
- 125 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0052:125-126
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 3 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“3”
Context: CHDD0052
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 7.03Grade Unit: g/tIntercept: 28 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 7.03
- Grade Unit
- g/t
- Intercept
- 28 m
- From
- 134 m
- To
- 162 m
- Intercept Depth
- 134 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:134-162
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 7.03 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 196.8 g/t·m is strong (grade alone is exceptional; the better of the two is used).
Positive factors
- 7.03 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“7.03”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0Grade Unit: g/tIntercept: 28 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 28 m
- From
- 134 m
- To
- 162 m
- Intercept Depth
- 134 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:134-162
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 0Grade Unit: ppmIntercept: 28 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- ppm
- Intercept
- 28 m
- From
- 134 m
- To
- 162 m
- Intercept Depth
- 134 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:134-162
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 0 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“0”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0052Charger · goldGrade: 9.02Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- CHDD0052
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 9.02
- Grade Unit
- g/t
- Intercept
- 20 m
- From
- 134 m
- To
- 154 m
- Intercept Depth
- 134 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0052:134-154
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 9.02 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 180.4 g/t·m is strong (grade alone is exceptional; the better of the two is used).
Positive factors
- 9.02 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“9.02”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0052Charger · silverGrade: 0Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- CHDD0052
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 20 m
- From
- 134 m
- To
- 154 m
- Intercept Depth
- 134 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0052:134-154
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0052Charger · molybdenumGrade: 0Grade Unit: ppmIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- CHDD0052
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- ppm
- Intercept
- 20 m
- From
- 134 m
- To
- 154 m
- Intercept Depth
- 134 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0052:134-154
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 0 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“0”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 3.89Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 3.89
- Grade Unit
- g/t
- Intercept
- 5 m
- From
- 166 m
- To
- 171 m
- Intercept Depth
- 166 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:166-171
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 3.89 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 19.4 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 3.89 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.89”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 5 m
- From
- 166 m
- To
- 171 m
- Intercept Depth
- 166 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:166-171
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 0Grade Unit: ppmIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- ppm
- Intercept
- 5 m
- From
- 166 m
- To
- 171 m
- Intercept Depth
- 166 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:166-171
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 0 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“0”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0052Charger · goldGrade: 12.99Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0052
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 12.99
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 169 m
- To
- 170 m
- Intercept Depth
- 169 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0052:169-170
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 12.99 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 13.0 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 12.99 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“12.99”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0052Charger · silverGrade: 0Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0052
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 169 m
- To
- 170 m
- Intercept Depth
- 169 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0052:169-170
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0052Charger · molybdenumGrade: 0Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0052
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 169 m
- To
- 170 m
- Intercept Depth
- 169 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0052:169-170
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 0 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“0”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 0.89Grade Unit: g/tIntercept: 14 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.89
- Grade Unit
- g/t
- Intercept
- 14 m
- From
- 175 m
- To
- 189 m
- Intercept Depth
- 175 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:175-189
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.89 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 12.5 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.89”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0Grade Unit: g/tIntercept: 14 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 14 m
- From
- 175 m
- To
- 189 m
- Intercept Depth
- 175 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:175-189
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 0Grade Unit: ppmIntercept: 14 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- ppm
- Intercept
- 14 m
- From
- 175 m
- To
- 189 m
- Intercept Depth
- 175 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:175-189
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 0 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“0”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 0.77Grade Unit: g/tIntercept: 13 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.77
- Grade Unit
- g/t
- Intercept
- 13 m
- From
- 199 m
- To
- 212 m
- Intercept Depth
- 199 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:199-212
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.77 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 10.0 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.77”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0Grade Unit: g/tIntercept: 13 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 13 m
- From
- 199 m
- To
- 212 m
- Intercept Depth
- 199 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:199-212
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 0Grade Unit: ppmIntercept: 13 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- ppm
- Intercept
- 13 m
- From
- 199 m
- To
- 212 m
- Intercept Depth
- 199 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:199-212
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 0 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“0”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 5.17Grade Unit: g/tIntercept: 17 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 5.17
- Grade Unit
- g/t
- Intercept
- 17 m
- From
- 223 m
- To
- 240 m
- Intercept Depth
- 223 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:223-240
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 5.17 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 87.9 g/t·m is moderate (grade alone is exceptional; the better of the two is used).
Positive factors
- 5.17 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“5.17”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0Grade Unit: %Intercept: 17 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 17 m
- From
- 223 m
- To
- 240 m
- Intercept Depth
- 223 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:223-240
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.1Grade Unit: g/tIntercept: 17 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 17 m
- From
- 223 m
- To
- 240 m
- Intercept Depth
- 223 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:223-240
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.7 g/t·m is below.
Negative factors
- 0.1 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 0Grade Unit: ppmIntercept: 17 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- ppm
- Intercept
- 17 m
- From
- 223 m
- To
- 240 m
- Intercept Depth
- 223 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:223-240
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 0 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“0”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0052Charger · goldGrade: 20.08Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- CHDD0052
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 20.08
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 233 m
- To
- 237 m
- Intercept Depth
- 233 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0052:233-237
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 20.08 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 80.3 g/t·m is moderate (grade alone is exceptional; the better of the two is used).
Positive factors
- 20.08 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“20.08”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0052Charger · silverGrade: 0Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- CHDD0052
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 233 m
- To
- 237 m
- Intercept Depth
- 233 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0052:233-237
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0052Charger · molybdenumGrade: 0Grade Unit: ppmIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- CHDD0052
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0
- Grade Unit
- ppm
- Intercept
- 4 m
- From
- 233 m
- To
- 237 m
- Intercept Depth
- 233 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0052:233-237
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 0 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“0”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 2.52Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 2.52
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 283 m
- To
- 284 m
- Intercept Depth
- 283 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:283-284
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 2.52 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.5 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 2.52 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.52”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.02Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 1 m
- From
- 283 m
- To
- 284 m
- Intercept Depth
- 283 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:283-284
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.02 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.54Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.54
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 283 m
- To
- 284 m
- Intercept Depth
- 283 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:283-284
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.54 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.5 g/t·m is below.
Negative factors
- 0.54 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.54”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 4Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 4
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 283 m
- To
- 284 m
- Intercept Depth
- 283 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:283-284
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 4 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“4”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 0.58Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.58
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 304 m
- To
- 305 m
- Intercept Depth
- 304 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:304-305
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.58 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.58”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.02Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 1 m
- From
- 304 m
- To
- 305 m
- Intercept Depth
- 304 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:304-305
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.02 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.35Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.35
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 304 m
- To
- 305 m
- Intercept Depth
- 304 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:304-305
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.35 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.3 g/t·m is below.
Negative factors
- 0.35 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.35”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 14Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 14
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 304 m
- To
- 305 m
- Intercept Depth
- 304 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:304-305
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 14 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“14”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 1.3Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.3
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 314 m
- To
- 316 m
- Intercept Depth
- 314 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:314-316
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.3 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.6 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.30”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.05Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.05
- Grade Unit
- %
- Intercept
- 2 m
- From
- 314 m
- To
- 316 m
- Intercept Depth
- 314 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:314-316
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.05 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.05 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.05”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 7.89Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 7.89
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 314 m
- To
- 316 m
- Intercept Depth
- 314 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:314-316
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 7.89 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 15.8 g/t·m is below.
Negative factors
- 7.89 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“7.89”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 368Grade Unit: ppmIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 368
- Grade Unit
- ppm
- Intercept
- 2 m
- From
- 314 m
- To
- 316 m
- Intercept Depth
- 314 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:314-316
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 368 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“368”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 0.83Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.83
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 341 m
- To
- 342 m
- Intercept Depth
- 341 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:341-342
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.83 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.83”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.01Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 1 m
- From
- 341 m
- To
- 342 m
- Intercept Depth
- 341 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:341-342
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.13Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.13
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 341 m
- To
- 342 m
- Intercept Depth
- 341 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:341-342
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.13 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.13 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.13”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 4Grade Unit: ppmIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 4
- Grade Unit
- ppm
- Intercept
- 1 m
- From
- 341 m
- To
- 342 m
- Intercept Depth
- 341 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:341-342
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 4 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“4”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 0.53Grade Unit: g/tIntercept: 1.38 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.53
- Grade Unit
- g/t
- Intercept
- 1.38 m
- From
- 349 m
- To
- 350.38 m
- Intercept Depth
- 349 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:349-350.38
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.53 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.53”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · copperGrade: 0.01Grade Unit: %Intercept: 1.38 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- copper
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 1.38 m
- From
- 349 m
- To
- 350.38 m
- Intercept Depth
- 349 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:349-350.38
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · silverGrade: 0.09Grade Unit: g/tIntercept: 1.38 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- silver
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 1.38 m
- From
- 349 m
- To
- 350.38 m
- Intercept Depth
- 349 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:349-350.38
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.09 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · molybdenumGrade: 2Grade Unit: ppmIntercept: 1.38 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- molybdenum
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 2
- Grade Unit
- ppm
- Intercept
- 1.38 m
- From
- 349 m
- To
- 350.38 m
- Intercept Depth
- 349 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:349-350.38
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table: 2 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for molybdenum; intercept not scored.
Evidence · table
“2”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0054Charger · goldGrade: 1.61Grade Unit: g/tIntercept: 13 mView all detailsHide details
Identity
- Hole ID
- CHDD0054
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.61
- Grade Unit
- g/t
- Intercept
- 13 m
- From
- 139 m
- To
- 152 m
- Intercept Depth
- 139 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0054:139-152
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.61 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 20.9 g/t·m is weak (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.61”
Context: CHDD0054
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 0.8Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.8
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 164 m
- To
- 166 m
- Intercept Depth
- 164 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:164-166
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.8 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.6 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.80”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 1.4Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.4
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 182 m
- To
- 183 m
- Intercept Depth
- 182 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:182-183
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.4 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.4 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.40”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0055Charger · goldGrade: 2Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- CHDD0055
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 2
- Grade Unit
- g/t
- Intercept
- 5 m
- From
- 154 m
- To
- 159 m
- Intercept Depth
- 154 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0055:154-159
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 2 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 10.0 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 2 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.00”
Context: CHDD0055
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 1.37Grade Unit: g/tIntercept: 11 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.37
- Grade Unit
- g/t
- Intercept
- 11 m
- From
- 166 m
- To
- 177 m
- Intercept Depth
- 166 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:166-177
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.37 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 15.1 g/t·m is weak (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.37”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0055Charger · goldGrade: 3.93Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0055
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 3.93
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 170 m
- To
- 171 m
- Intercept Depth
- 170 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0055:170-171
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 3.93 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.9 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 3.93 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.93”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andthe interpreted mineralized breccia and vein · goldGrade: 8.79Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- the interpreted mineralized breccia and vein
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 8.79
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 176 m
- To
- 177 m
- Intercept Depth
- 176 m
Classification
- Sample Type
- drill
- Group ID
- and:176-177
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 8.79 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 8.8 g/t·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 8.79 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“8.79”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0057Charger · goldGrade: 1.38Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0057
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.38
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 102 m
- To
- 103 m
- Intercept Depth
- 102 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0057:102-103
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.38 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.4 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.38”
Context: CHDD0057
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 0.77Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 0.77
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 136 m
- To
- 137 m
- Intercept Depth
- 136 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:136-137
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.77 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.77”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 1.97Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.97
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 187 m
- To
- 190 m
- Intercept Depth
- 187 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:187-190
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.97 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 5.9 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.97”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0057Charger · goldGrade: 1.97Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- CHDD0057
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 1.97
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 187 m
- To
- 190 m
- Intercept Depth
- 187 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0057:187-190
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 1.97 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 5.9 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.97”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0060the interpreted mineralized breccia and vein · goldGrade: 4.65Grade Unit: g/tIntercept: 49 mView all detailsHide details
Identity
- Hole ID
- CHDD0060
- Project
- the interpreted mineralized breccia and vein
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 4.65
- Grade Unit
- g/t
- Intercept
- 49 m
- From
- 119 m
- To
- 168 m
- Intercept Depth
- 119 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0060:119-168
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 4.65 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 227.9 g/t·m is strong.
Positive factors
- 4.65 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“4.65”
Context: CHDD0060
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0060the interpreted mineralized breccia and vein · goldGrade: 6.38Grade Unit: g/tIntercept: 33 mView all detailsHide details
Identity
- Hole ID
- CHDD0060
- Project
- the interpreted mineralized breccia and vein
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 6.38
- Grade Unit
- g/t
- Intercept
- 33 m
- From
- 135 m
- To
- 168 m
- Intercept Depth
- 135 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0060:135-168
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 6.38 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 210.5 g/t·m is strong (grade alone is exceptional; the better of the two is used).
Positive factors
- 6.38 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.38”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andthe interpreted mineralized breccia and vein · goldGrade: 10.41Grade Unit: g/tIntercept: 8 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- the interpreted mineralized breccia and vein
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 10.41
- Grade Unit
- g/t
- Intercept
- 8 m
- From
- 135 m
- To
- 143 m
- Intercept Depth
- 135 m
Classification
- Sample Type
- drill
- Group ID
- and:135-143
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 10.41 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 83.3 g/t·m is moderate (grade alone is exceptional; the better of the two is used).
Positive factors
- 10.41 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“10.41”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andthe interpreted mineralized breccia and vein · goldGrade: 40.43Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- the interpreted mineralized breccia and vein
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 40.43
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 135 m
- To
- 136 m
- Intercept Depth
- 135 m
Classification
- Sample Type
- drill
- Group ID
- and:135-136
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 40.43 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 40.4 g/t·m is moderate (grade alone is exceptional; the better of the two is used).
Positive factors
- 40.43 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“40.43”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0062the interpreted mineralized breccia and vein · goldGrade: 8.71Grade Unit: g/tIntercept: 25 mView all detailsHide details
Identity
- Hole ID
- CHDD0062
- Project
- the interpreted mineralized breccia and vein
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 8.71
- Grade Unit
- g/t
- Intercept
- 25 m
- From
- 138 m
- To
- 163 m
- Intercept Depth
- 138 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0062:138-163
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 8.71 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 217.8 g/t·m is strong (grade alone is exceptional; the better of the two is used).
Positive factors
- 8.71 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“8.71”
Context: CHDD0062
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0062the interpreted mineralized breccia and vein · goldGrade: 9.25Grade Unit: g/tIntercept: 19 mView all detailsHide details
Identity
- Hole ID
- CHDD0062
- Project
- the interpreted mineralized breccia and vein
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 9.25
- Grade Unit
- g/t
- Intercept
- 19 m
- From
- 138 m
- To
- 157 m
- Intercept Depth
- 138 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0062:138-157
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 9.25 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 175.8 g/t·m is strong (grade alone is exceptional; the better of the two is used).
Positive factors
- 9.25 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“9.25”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andthe interpreted mineralized breccia and vein · goldGrade: 36.51Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- the interpreted mineralized breccia and vein
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 36.51
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 138 m
- To
- 141 m
- Intercept Depth
- 138 m
Classification
- Sample Type
- drill
- Group ID
- and:138-141
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 36.51 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 109.5 g/t·m is strong (grade alone is exceptional; the better of the two is used).
Positive factors
- 36.51 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“36.51”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andthe interpreted mineralized breccia and vein · goldGrade: 35.43Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- the interpreted mineralized breccia and vein
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 35.43
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 162 m
- To
- 163 m
- Intercept Depth
- 162 m
Classification
- Sample Type
- drill
- Group ID
- and:162-163
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 35.43 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 35.4 g/t·m is moderate (grade alone is exceptional; the better of the two is used).
Positive factors
- 35.43 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“35.43”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 11.9Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 11.9
- Grade Unit
- g/t
- Intercept
- 5 m
- From
- 168 m
- To
- 173 m
- Intercept Depth
- 168 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:168-173
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 11.9 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 59.5 g/t·m is moderate (grade alone is exceptional; the better of the two is used).
Positive factors
- 11.9 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“11.90”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 8.13Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 8.13
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 190 m
- To
- 191 m
- Intercept Depth
- 190 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:190-191
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 8.13 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 8.1 g/t·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 8.13 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“8.13”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CHDD0027Charger · goldGrade: 3.17Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- CHDD0027
- Project
- Charger
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 3.17
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 214 m
- To
- 217 m
- Intercept Depth
- 214 m
Classification
- Sample Type
- drill
- Group ID
- CHDD0027:214-217
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 3.17 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 9.5 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 3.17 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.17”
Context: Table 1: Significant Intercepts from Dia
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andthe interpreted mineralized breccia and vein · goldGrade: 7.33Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- the interpreted mineralized breccia and vein
- Commodity
- gold
- Region
- côte d’ivoire
- Reported Region
- côte d’ivoire
- Ticker
- ARIC
Geometry
- Grade
- 7.33
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 214 m
- To
- 215 m
- Intercept Depth
- 214 m
Classification
- Sample Type
- drill
- Group ID
- and:214-215
- Mining Method
- unknown
QA/QC
- Laboratory
- Intertek Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-27T00:00:00.000Z
Reasoning: Expanded from assay table. 7.33 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 7.3 g/t·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 7.33 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“7.33”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.