# AUZ: Sconi overlooked scandium potential

Canonical Atlas analysis: https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e

Original source: https://www.asx.com.au/asx/v2/statistics/displayAnnouncement.do?display=pdf&idsId=03165468

Publisher: asx

Original announcement: 2026-11-12T22:50:00.000Z

Analysis by Minestarters Atlas

Atlas analysis published: 2026-11-12T23:16:24.243Z

Atlas analysis updated: 2026-11-12T23:16:24.243Z

- Company: Australian Mines Limited

- Ticker: AUZ

- Exchange: ASX

- Region: Queensland, Australia

- Primary commodity: Scandium

- Secondary commodities: None reported

- Document categories: Drill results

- Extracted: 2026-11-12 23:07:43 UTC

Narrative sentiment: 0.70 · Bullish

## Minestarters Atlas summary

Australian Mines Limited has re-evaluated historical drilling at its Sconi project in Queensland, identifying significant shallow scandium intersections on the Lucknow and Kokomo mining leases. This review, which focused on scandium rather than the historical nickel and cobalt targets, revealed high-grade intercepts such as 27 m at 883 ppm Sc from surface, including 21 m at 1,036 ppm Sc. The company plans to consider further drilling to test extensions and evaluate an updated Mineral Resource estimate focused on scandium.

Reasoning: A re-evaluation of historical drilling at the Sconi project revealed significant shallow, high-grade scandium intercepts on granted mining leases, such as 27 m at 883 ppm Sc from surface, which could lead to a new scandium-focused resource estimate and project development.

- Positive factor: High-grade scandium intercepts identified from historical data review

- Positive factor: Shallow mineralization, including from surface

- Positive factor: Located on granted mining leases \(Lucknow and Kokomo\)

- Positive factor: Existing historical metallurgical testwork for scandium oxide production

- Positive factor: Growing demand forecast for scandium in key industries

- Positive factor: Potential for an updated Mineral Resource estimate focused on scandium

- Negative factor: Results are from historical drilling, no new assays reported

- Negative factor: True widths of intercepts have not been established

- Negative factor: Further work \(drilling, data verification\) is required to assess continuity and scale

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 92

## Classification and evidence

No classification tags are available.

## Extracted facts

Stored fact records: 92. Some facts used in scoring do not have a stored record.

## Drill Results (92)

### LKRC099

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-0)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC099
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 883
- Grade Unit: ppm
- Intercept: 27 m
- From: 0 m
- To: 27 m
- Hole Depth: 27 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC099:0-27
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284839
- Northing: 7894920
- Elevation: 555.8 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant shallow, high-grade scandium intercept from surface was identified in historical drilling, indicating strong potential for further evaluation.

- Positive factor: High-grade scandium intercept \(883 ppm Sc\)

- Positive factor: Significant width \(27 m\)

- Positive factor: Starts from surface \(0 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> LKRC099 27 m at 883 ppm Sc from surface

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC099

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-1)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC099
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 1036
- Grade Unit: ppm
- Intercept: 21 m
- From: 6 m
- To: 27 m
- Hole Depth: 27 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC099:6-27
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284839
- Northing: 7894920
- Elevation: 555.8 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: An exceptionally high-grade scandium sub-interval within a broader shallow intercept highlights significant potential.

- Positive factor: Very high-grade scandium sub-interval \(1,036 ppm Sc\)

- Positive factor: Good width \(21 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> including 21 m at 1,036 ppm Sc from 6 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC099

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-2)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC099
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 1375
- Grade Unit: ppm
- Intercept: 10 m
- From: 17 m
- To: 27 m
- Hole Depth: 27 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC099:17-27
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284839
- Northing: 7894920
- Elevation: 555.8 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A bonanza-grade scandium sub-interval extending to the end of the hole suggests significant upside potential at depth.

- Positive factor: Bonanza-grade scandium sub-interval \(1,375 ppm Sc\)

- Positive factor: Good width \(10 m\)

- Positive factor: Extends to end of hole, indicating open mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> and 10 m at 1,375 ppm Sc from 17 m to end of hole

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC205

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-3)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC205
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 499
- Grade Unit: ppm
- Intercept: 15 m
- From: 0 m
- To: 15 m
- Hole Depth: 21 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC205:0-15
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284830
- Northing: 7894890
- Elevation: 556 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant shallow, high-grade scandium intercept from surface was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(499 ppm Sc\)

- Positive factor: Good width \(15 m\)

- Positive factor: Starts from surface \(0 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 15 m at 499 ppm Sc from surface

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC205

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-4)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC205
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 681
- Grade Unit: ppm
- Intercept: 9 m
- From: 6 m
- To: 15 m
- Hole Depth: 21 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC205:6-15
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284830
- Northing: 7894890
- Elevation: 556 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A very high-grade scandium sub-interval within a broader shallow intercept highlights strong potential.

- Positive factor: Very high-grade scandium sub-interval \(681 ppm Sc\)

- Positive factor: Good width \(9 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 9 m at 681 ppm Sc from 6 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC436

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-5)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC436
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 462
- Grade Unit: ppm
- Intercept: 23 m
- From: 5 m
- To: 28 m
- Hole Depth: 30 m
- Intercept Depth: 5 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC436:5-28
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284799.5
- Northing: 7894820.4
- Elevation: 552 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant shallow, high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(462 ppm Sc\)

- Positive factor: Good width \(23 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 23 m at 462 ppm Sc from 5 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC436

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-6)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC436
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 589
- Grade Unit: ppm
- Intercept: 15 m
- From: 8 m
- To: 23 m
- Hole Depth: 30 m
- Intercept Depth: 5 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC436:8-23
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284799.5
- Northing: 7894820.4
- Elevation: 552 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium sub-interval within a broader shallow intercept highlights strong potential.

- Positive factor: High-grade scandium sub-interval \(589 ppm Sc\)

- Positive factor: Good width \(15 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 15 m at 589 ppm Sc from 8 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC206

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-7)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC206
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 455
- Grade Unit: ppm
- Intercept: 14 m
- From: 5 m
- To: 19 m
- Hole Depth: 30 m
- Intercept Depth: 5 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC206:5-19
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284840
- Northing: 7894899
- Elevation: 556 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant shallow, high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(455 ppm Sc\)

- Positive factor: Good width \(14 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 14 m at 455 ppm Sc from 5 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC206

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-8)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC206
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 586
- Grade Unit: ppm
- Intercept: 8 m
- From: 6 m
- To: 14 m
- Hole Depth: 30 m
- Intercept Depth: 5 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC206:6-14
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284840
- Northing: 7894899
- Elevation: 556 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium sub-interval within a broader shallow intercept highlights strong potential.

- Positive factor: High-grade scandium sub-interval \(586 ppm Sc\)

- Positive factor: Good width \(8 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 8 m at 586 ppm Sc from 6 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC217

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-9)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC217
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 453
- Grade Unit: ppm
- Intercept: 20 m
- From: 3 m
- To: 23 m
- Hole Depth: 27 m
- Intercept Depth: 3 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC217:3-23
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284762
- Northing: 7894779
- Elevation: 546.9 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant shallow, high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(453 ppm Sc\)

- Positive factor: Good width \(20 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 20 m at 453 ppm Sc from 3 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC217

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-10)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC217
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 574
- Grade Unit: ppm
- Intercept: 13 m
- From: 9 m
- To: 22 m
- Hole Depth: 27 m
- Intercept Depth: 3 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC217:9-22
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284762
- Northing: 7894779
- Elevation: 546.9 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium sub-interval within a broader shallow intercept highlights strong potential.

- Positive factor: High-grade scandium sub-interval \(574 ppm Sc\)

- Positive factor: Good width \(13 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 13 m at 574 ppm Sc from 9 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC076

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-11)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC076
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 452
- Grade Unit: ppm
- Intercept: 18 m
- From: 12 m
- To: 30 m
- Hole Depth: 36 m
- Intercept Depth: 12 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC076:12-30
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284819
- Northing: 7894958
- Elevation: 555.6 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(452 ppm Sc\)

- Positive factor: Good width \(18 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 18 m at 452 ppm Sc from 12 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC076

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-12)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC076
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 503
- Grade Unit: ppm
- Intercept: 14 m
- From: 16 m
- To: 30 m
- Hole Depth: 36 m
- Intercept Depth: 12 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC076:16-30
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284819
- Northing: 7894958
- Elevation: 555.6 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium sub-interval within a broader intercept highlights strong potential.

- Positive factor: High-grade scandium sub-interval \(503 ppm Sc\)

- Positive factor: Good width \(14 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 14 m at 503 ppm Sc from 16 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1013

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-13)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1013
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 462
- Grade Unit: ppm
- Intercept: 11 m
- From: 14 m
- To: 25 m
- Hole Depth: 25 m
- Intercept Depth: 14 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1013:14-25
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307453
- Northing: 7948295
- Elevation: 604.5 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(462 ppm Sc\)

- Positive factor: Good width \(11 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 11 m at 462 ppm Sc from 14 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1013

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-14)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1013
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 634
- Grade Unit: ppm
- Intercept: 4 m
- From: 21 m
- To: 25 m
- Hole Depth: 25 m
- Intercept Depth: 14 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1013:21-25
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307453
- Northing: 7948295
- Elevation: 604.5 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A very high-grade scandium sub-interval within a broader intercept highlights strong potential.

- Positive factor: Very high-grade scandium sub-interval \(634 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 4 m at 634 ppm Sc from 21 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1020

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-15)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1020
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 453
- Grade Unit: ppm
- Intercept: 21 m
- From: 4 m
- To: 25 m
- Hole Depth: 31 m
- Intercept Depth: 4 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1020:4-25
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307413
- Northing: 7948230
- Elevation: 608 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant shallow, high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(453 ppm Sc\)

- Positive factor: Good width \(21 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 21 m at 453 ppm Sc from 4 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1020

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-16)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1020
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 573
- Grade Unit: ppm
- Intercept: 12 m
- From: 13 m
- To: 25 m
- Hole Depth: 31 m
- Intercept Depth: 4 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1020:13-25
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307413
- Northing: 7948230
- Elevation: 608 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium sub-interval within a broader shallow intercept highlights strong potential.

- Positive factor: High-grade scandium sub-interval \(573 ppm Sc\)

- Positive factor: Good width \(12 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 12 m at 573 ppm Sc from 13 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-805

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-17)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-805
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 454
- Grade Unit: ppm
- Intercept: 35 m
- From: 18 m
- To: 53 m
- Hole Depth: 53 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-805:18-53
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307406
- Northing: 7948135
- Elevation: 602.7 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant broad, high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(454 ppm Sc\)

- Positive factor: Very good width \(35 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 35 m at 454 ppm Sc from 18 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-805

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-18)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-805
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 555
- Grade Unit: ppm
- Intercept: 15 m
- From: 38 m
- To: 53 m
- Hole Depth: 53 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-805:38-53
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307406
- Northing: 7948135
- Elevation: 602.7 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium sub-interval within a broader intercept highlights strong potential.

- Positive factor: High-grade scandium sub-interval \(555 ppm Sc\)

- Positive factor: Good width \(15 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 15 m at 555 ppm Sc from 38 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-828

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-19)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-828
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 464
- Grade Unit: ppm
- Intercept: 15 m
- From: 15 m
- To: 30 m
- Hole Depth: 40 m
- Intercept Depth: 15 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-828:15-30
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307619
- Northing: 7948903
- Elevation: 599.7 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(464 ppm Sc\)

- Positive factor: Good width \(15 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 15 m at 464 ppm Sc from 15 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-828

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-20)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-828
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 481
- Grade Unit: ppm
- Intercept: 14 m
- From: 15 m
- To: 29 m
- Hole Depth: 40 m
- Intercept Depth: 15 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-828:15-29
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307619
- Northing: 7948903
- Elevation: 599.7 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium sub-interval within a broader intercept highlights strong potential.

- Positive factor: High-grade scandium sub-interval \(481 ppm Sc\)

- Positive factor: Good width \(14 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 14 m at 481 ppm Sc from 15 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-249

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-21)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-249
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 413
- Grade Unit: ppm
- Intercept: 7 m
- From: 10 m
- To: 17 m
- Hole Depth: 30 m
- Intercept Depth: 10 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-249:10-17
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307637
- Northing: 7948902.1
- Elevation: 599.1 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(413 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 7 m at 413 ppm Sc from 10 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-249

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-22)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-249
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 467
- Grade Unit: ppm
- Intercept: 3 m
- From: 14 m
- To: 17 m
- Hole Depth: 30 m
- Intercept Depth: 10 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-249:14-17
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307637
- Northing: 7948902.1
- Elevation: 599.1 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium sub-interval within a broader intercept highlights strong potential.

- Positive factor: High-grade scandium sub-interval \(467 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 3 m at 467 ppm Sc from 14 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-861

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-23)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-861
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 464
- Grade Unit: ppm
- Intercept: 6 m
- From: 13 m
- To: 19 m
- Hole Depth: 31 m
- Intercept Depth: 13 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-861:13-19
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307414
- Northing: 7948184
- Elevation: 603.6 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(464 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 6 m at 464 ppm Sc from 13 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-861

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-24)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-861
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 458
- Grade Unit: ppm
- Intercept: 5 m
- From: 15 m
- To: 20 m
- Hole Depth: 31 m
- Intercept Depth: 13 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-861:15-20
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307414
- Northing: 7948184
- Elevation: 603.6 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(458 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · text

> 5 m at 458 ppm Sc from 15 m

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC099

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-25)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC099
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 954.46
- Grade Unit: ppm
- Intercept: 24 m
- From: 3 m
- To: 27 m
- Hole Depth: 27 m
- Intercept Depth: 3 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC099:3-27
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284839
- Northing: 7894920
- Elevation: 555.8 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A very high-grade and wide scandium intercept from shallow depths highlights strong potential.

- Positive factor: Very high-grade scandium intercept \(954.46 ppm Sc\)

- Positive factor: Significant width \(24 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 954.46

Context: 24

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1036

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-26)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1036
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 771
- Grade Unit: ppm
- Intercept: 1 m
- From: 13 m
- To: 14 m
- Hole Depth: 22 m
- Intercept Depth: 13 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1036:13-14
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307393
- Northing: 7948134
- Elevation: 604.1 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A very high-grade but narrow scandium intercept was identified in historical drilling, indicating localized high-grade potential.

- Positive factor: Very high-grade scandium intercept \(771 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: Narrow width \(1 m\)

- Negative factor: True width not established

Evidence · table

> 771.00

Context: 1

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC205

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-27)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC205
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 680.89
- Grade Unit: ppm
- Intercept: 9 m
- From: 6 m
- To: 15 m
- Hole Depth: 21 m
- Intercept Depth: 6 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC205:6-15
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284830
- Northing: 7894890
- Elevation: 556 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A very high-grade and wide scandium intercept from shallow depths highlights strong potential.

- Positive factor: Very high-grade scandium intercept \(680.89 ppm Sc\)

- Positive factor: Good width \(9 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 680.89

Context: 9

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1013

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-28)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1013
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 461.91
- Grade Unit: ppm
- Intercept: 11 m
- From: 14 m
- To: 25 m
- Hole Depth: 25 m
- Intercept Depth: 14 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1013:14-25
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307453
- Northing: 7948295
- Elevation: 604.5 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(461.91 ppm Sc\)

- Positive factor: Good width \(11 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 461.91

Context: 11

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC290

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-29)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC290
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 595.5
- Grade Unit: ppm
- Intercept: 2 m
- From: 14 m
- To: 16 m
- Hole Depth: 24 m
- Intercept Depth: 14 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC290:14-16
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284573
- Northing: 7893999
- Elevation: 551.3 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade but narrow scandium intercept was identified in historical drilling, indicating localized high-grade potential.

- Positive factor: High-grade scandium intercept \(595.5 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: Narrow width \(2 m\)

- Negative factor: True width not established

Evidence · table

> 595.50

Context: 2

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1045

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-30)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1045
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 592.5
- Grade Unit: ppm
- Intercept: 4 m
- From: 21 m
- To: 25 m
- Hole Depth: 31 m
- Intercept Depth: 21 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1045:21-25
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307455
- Northing: 7948266
- Elevation: 604.5 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(592.5 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 592.50

Context: 4

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1045

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-31)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1045
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 456.83
- Grade Unit: ppm
- Intercept: 6 m
- From: 21 m
- To: 27 m
- Hole Depth: 31 m
- Intercept Depth: 21 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1045:21-27
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307455
- Northing: 7948266
- Elevation: 604.5 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(456.83 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 456.83

Context: 6

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC289

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-32)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC289
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 589.5
- Grade Unit: ppm
- Intercept: 4 m
- From: 15 m
- To: 19 m
- Hole Depth: 24 m
- Intercept Depth: 15 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC289:15-19
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284605
- Northing: 7894000
- Elevation: 550.4 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(589.5 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 589.50

Context: 4

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC289

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-33)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC289
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 484.5
- Grade Unit: ppm
- Intercept: 6 m
- From: 13 m
- To: 19 m
- Hole Depth: 24 m
- Intercept Depth: 13 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC289:13-19
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284605
- Northing: 7894000
- Elevation: 550.4 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(484.5 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 484.50

Context: 6

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC436

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-34)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC436
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 588.87
- Grade Unit: ppm
- Intercept: 15 m
- From: 8 m
- To: 23 m
- Hole Depth: 30 m
- Intercept Depth: 8 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC436:8-23
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284799.5
- Northing: 7894820.4
- Elevation: 552 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade and wide scandium intercept from shallow depths highlights strong potential.

- Positive factor: High-grade scandium intercept \(588.87 ppm Sc\)

- Positive factor: Good width \(15 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 588.87

Context: 15

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC436

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-35)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC436
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 462.39
- Grade Unit: ppm
- Intercept: 23 m
- From: 5 m
- To: 28 m
- Hole Depth: 30 m
- Intercept Depth: 5 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC436:5-28
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284799.5
- Northing: 7894820.4
- Elevation: 552 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant shallow, high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(462.39 ppm Sc\)

- Positive factor: Good width \(23 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 462.39

Context: 23

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC206

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-36)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC206
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 586.12
- Grade Unit: ppm
- Intercept: 8 m
- From: 6 m
- To: 14 m
- Hole Depth: 30 m
- Intercept Depth: 6 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC206:6-14
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284840
- Northing: 7894899
- Elevation: 556 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade and wide scandium intercept from shallow depths highlights strong potential.

- Positive factor: High-grade scandium intercept \(586.12 ppm Sc\)

- Positive factor: Good width \(8 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 586.12

Context: 8

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC206

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-37)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC206
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 455.36
- Grade Unit: ppm
- Intercept: 14 m
- From: 5 m
- To: 19 m
- Hole Depth: 30 m
- Intercept Depth: 5 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC206:5-19
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284840
- Northing: 7894899
- Elevation: 556 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant shallow, high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(455.36 ppm Sc\)

- Positive factor: Good width \(14 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 455.36

Context: 14

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC294

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-38)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC294
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 575
- Grade Unit: ppm
- Intercept: 1 m
- From: 20 m
- To: 21 m
- Hole Depth: 36 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC294:20-21
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284839
- Northing: 7894860
- Elevation: 556.1 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade but narrow scandium intercept was identified in historical drilling, indicating localized high-grade potential.

- Positive factor: High-grade scandium intercept \(575 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: Narrow width \(1 m\)

- Negative factor: True width not established

Evidence · table

> 575.00

Context: 1

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC294

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-39)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC294
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 383.5
- Grade Unit: ppm
- Intercept: 4 m
- From: 10 m
- To: 14 m
- Hole Depth: 36 m
- Intercept Depth: 10 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC294:10-14
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284839
- Northing: 7894860
- Elevation: 556.1 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(383.5 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 383.50

Context: 4

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC217

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-40)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC217
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 574.15
- Grade Unit: ppm
- Intercept: 13 m
- From: 9 m
- To: 22 m
- Hole Depth: 27 m
- Intercept Depth: 9 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC217:9-22
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284762
- Northing: 7894779
- Elevation: 546.9 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade and wide scandium intercept from shallow depths highlights strong potential.

- Positive factor: High-grade scandium intercept \(574.15 ppm Sc\)

- Positive factor: Good width \(13 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 574.15

Context: 13

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC217

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-41)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC217
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 452.55
- Grade Unit: ppm
- Intercept: 20 m
- From: 3 m
- To: 23 m
- Hole Depth: 27 m
- Intercept Depth: 3 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC217:3-23
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284762
- Northing: 7894779
- Elevation: 546.9 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant shallow, high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(452.55 ppm Sc\)

- Positive factor: Good width \(20 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 452.55

Context: 20

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1020

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-42)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1020
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 572.67
- Grade Unit: ppm
- Intercept: 12 m
- From: 13 m
- To: 25 m
- Hole Depth: 31 m
- Intercept Depth: 13 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1020:13-25
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307413
- Northing: 7948230
- Elevation: 608 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade and wide scandium intercept from shallow depths highlights strong potential.

- Positive factor: High-grade scandium intercept \(572.67 ppm Sc\)

- Positive factor: Good width \(12 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 572.67

Context: 12

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1020

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-43)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1020
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 452.86
- Grade Unit: ppm
- Intercept: 21 m
- From: 4 m
- To: 25 m
- Hole Depth: 31 m
- Intercept Depth: 4 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1020:4-25
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307413
- Northing: 7948230
- Elevation: 608 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant shallow, high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(452.86 ppm Sc\)

- Positive factor: Good width \(21 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 452.86

Context: 21

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-805

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-44)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-805
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 555.4
- Grade Unit: ppm
- Intercept: 15 m
- From: 38 m
- To: 53 m
- Hole Depth: 53 m
- Intercept Depth: 38 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-805:38-53
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307406
- Northing: 7948135
- Elevation: 602.7 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade and wide scandium intercept highlights strong potential.

- Positive factor: High-grade scandium intercept \(555.4 ppm Sc\)

- Positive factor: Good width \(15 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 555.40

Context: 15

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-805

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-45)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-805
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 454.06
- Grade Unit: ppm
- Intercept: 35 m
- From: 18 m
- To: 53 m
- Hole Depth: 53 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-805:18-53
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307406
- Northing: 7948135
- Elevation: 602.7 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant broad, high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(454.06 ppm Sc\)

- Positive factor: Very good width \(35 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 454.06

Context: 35

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKM1482

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-46)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKM1482
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 555.33
- Grade Unit: ppm
- Intercept: 3 m
- From: 20 m
- To: 23 m
- Hole Depth: 31 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKM1482:20-23
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284877
- Northing: 7895387
- Elevation: 549 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(555.33 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 555.33

Context: 3

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKM1482

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-47)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKM1482
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 481.75
- Grade Unit: ppm
- Intercept: 4 m
- From: 19 m
- To: 23 m
- Hole Depth: 31 m
- Intercept Depth: 19 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKM1482:19-23
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284877
- Northing: 7895387
- Elevation: 549 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(481.75 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 481.75

Context: 4

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1037

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-48)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1037
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 544.75
- Grade Unit: ppm
- Intercept: 4 m
- From: 3 m
- To: 7 m
- Hole Depth: 19 m
- Intercept Depth: 3 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1037:3-7
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307381
- Northing: 7948140
- Elevation: 604.7 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept from shallow depths highlights strong potential.

- Positive factor: High-grade scandium intercept \(544.75 ppm Sc\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 544.75

Context: 4

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1037

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-49)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1037
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 462.17
- Grade Unit: ppm
- Intercept: 6 m
- From: 3 m
- To: 9 m
- Hole Depth: 19 m
- Intercept Depth: 3 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1037:3-9
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307381
- Northing: 7948140
- Elevation: 604.7 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept from shallow depths was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(462.17 ppm Sc\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 462.17

Context: 6

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC151

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-50)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC151
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 544
- Grade Unit: ppm
- Intercept: 8 m
- From: 12 m
- To: 20 m
- Hole Depth: 24 m
- Intercept Depth: 12 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC151:12-20
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284693
- Northing: 7894234
- Elevation: 544.8 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade and wide scandium intercept highlights strong potential.

- Positive factor: High-grade scandium intercept \(544 ppm Sc\)

- Positive factor: Good width \(8 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 544.00

Context: 8

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC151

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-51)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC151
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 454.75
- Grade Unit: ppm
- Intercept: 12 m
- From: 9 m
- To: 21 m
- Hole Depth: 24 m
- Intercept Depth: 9 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC151:9-21
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284693
- Northing: 7894234
- Elevation: 544.8 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(454.75 ppm Sc\)

- Positive factor: Good width \(12 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 454.75

Context: 12

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-032

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-52)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-032
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 542
- Grade Unit: ppm
- Intercept: 2 m
- From: 22 m
- To: 24 m
- Hole Depth: 33 m
- Intercept Depth: 22 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-032:22-24
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307410.2
- Northing: 7948211.2
- Elevation: 606.4 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade but narrow scandium intercept was identified in historical drilling, indicating localized high-grade potential.

- Positive factor: High-grade scandium intercept \(542 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: Narrow width \(2 m\)

- Negative factor: True width not established

Evidence · table

> 542.00

Context: 2

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1023

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-53)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1023
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 530.75
- Grade Unit: ppm
- Intercept: 4 m
- From: 3 m
- To: 7 m
- Hole Depth: 25 m
- Intercept Depth: 3 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1023:3-7
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307390
- Northing: 7948202
- Elevation: 606.3 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept from shallow depths highlights strong potential.

- Positive factor: High-grade scandium intercept \(530.75 ppm Sc\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 530.75

Context: 4

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1043

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-54)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1043
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 513.33
- Grade Unit: ppm
- Intercept: 3 m
- From: 14 m
- To: 17 m
- Hole Depth: 25 m
- Intercept Depth: 14 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1043:14-17
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307473
- Northing: 7948320
- Elevation: 595.4 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(513.33 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 513.33

Context: 3

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC320

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-55)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC320
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 513
- Grade Unit: ppm
- Intercept: 2 m
- From: 7 m
- To: 9 m
- Hole Depth: 31 m
- Intercept Depth: 7 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC320:7-9
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284525.8
- Northing: 7893924.3
- Elevation: 549.4 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade but narrow scandium intercept from shallow depths highlights localized high-grade potential.

- Positive factor: High-grade scandium intercept \(513 ppm Sc\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: Narrow width \(2 m\)

- Negative factor: True width not established

Evidence · table

> 513.00

Context: 2

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC017

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-56)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC017
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 511.75
- Grade Unit: ppm
- Intercept: 4 m
- From: 18 m
- To: 22 m
- Hole Depth: 27 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC017:18-22
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284723
- Northing: 7894157
- Elevation: 546 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(511.75 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 511.75

Context: 4

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC017

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-57)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC017
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 460.2
- Grade Unit: ppm
- Intercept: 5 m
- From: 18 m
- To: 23 m
- Hole Depth: 27 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC017:18-23
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284723
- Northing: 7894157
- Elevation: 546 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(460.2 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 460.20

Context: 5

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC355

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-58)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC355
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 505
- Grade Unit: ppm
- Intercept: 1 m
- From: 16 m
- To: 17 m
- Hole Depth: 27 m
- Intercept Depth: 16 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC355:16-17
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284599.6
- Northing: 7894343.6
- Elevation: 542.8 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade but narrow scandium intercept was identified in historical drilling, indicating localized high-grade potential.

- Positive factor: High-grade scandium intercept \(505 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: Narrow width \(1 m\)

- Negative factor: True width not established

Evidence · table

> 505.00

Context: 1

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC355

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-59)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC355
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 394.33
- Grade Unit: ppm
- Intercept: 3 m
- From: 12 m
- To: 15 m
- Hole Depth: 27 m
- Intercept Depth: 12 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC355:12-15
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284599.6
- Northing: 7894343.6
- Elevation: 542.8 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(394.33 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 394.33

Context: 3

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC076

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-60)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC076
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 502.57
- Grade Unit: ppm
- Intercept: 14 m
- From: 16 m
- To: 30 m
- Hole Depth: 36 m
- Intercept Depth: 16 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC076:16-30
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284819
- Northing: 7894958
- Elevation: 555.6 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade and wide scandium intercept highlights strong potential.

- Positive factor: High-grade scandium intercept \(502.57 ppm Sc\)

- Positive factor: Good width \(14 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 502.57

Context: 14

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC211

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-61)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC211
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 501.67
- Grade Unit: ppm
- Intercept: 12 m
- From: 12 m
- To: 24 m
- Hole Depth: 27 m
- Intercept Depth: 12 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC211:12-24
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284802
- Northing: 7894859
- Elevation: 555.2 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade and wide scandium intercept highlights strong potential.

- Positive factor: High-grade scandium intercept \(501.67 ppm Sc\)

- Positive factor: Good width \(12 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 501.67

Context: 12

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC211

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-62)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC211
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 453.14
- Grade Unit: ppm
- Intercept: 14 m
- From: 11 m
- To: 25 m
- Hole Depth: 27 m
- Intercept Depth: 11 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC211:11-25
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284802
- Northing: 7894859
- Elevation: 555.2 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(453.14 ppm Sc\)

- Positive factor: Good width \(14 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 453.14

Context: 14

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC088

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-63)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC088
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 501
- Grade Unit: ppm
- Intercept: 3 m
- From: 6 m
- To: 9 m
- Hole Depth: 15 m
- Intercept Depth: 6 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC088:6-9
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284818
- Northing: 7894936
- Elevation: 556 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept from shallow depths highlights strong potential.

- Positive factor: High-grade scandium intercept \(501 ppm Sc\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 501.00

Context: 3

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC330

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-64)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC330
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 499
- Grade Unit: ppm
- Intercept: 2 m
- From: 13 m
- To: 15 m
- Hole Depth: 21 m
- Intercept Depth: 13 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC330:13-15
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284488.3
- Northing: 7894047.1
- Elevation: 554.1 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade but narrow scandium intercept was identified in historical drilling, indicating localized high-grade potential.

- Positive factor: High-grade scandium intercept \(499 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: Narrow width \(2 m\)

- Negative factor: True width not established

Evidence · table

> 499.00

Context: 2

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC330

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-65)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC330
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 346
- Grade Unit: ppm
- Intercept: 4 m
- From: 8 m
- To: 12 m
- Hole Depth: 21 m
- Intercept Depth: 8 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC330:8-12
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284488.3
- Northing: 7894047.1
- Elevation: 554.1 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept from shallow depths was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(346 ppm Sc\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 346.00

Context: 4

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC196

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-66)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC196
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 497.5
- Grade Unit: ppm
- Intercept: 4 m
- From: 11 m
- To: 15 m
- Hole Depth: 21 m
- Intercept Depth: 11 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC196:11-15
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284801
- Northing: 7894921
- Elevation: 556 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(497.5 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 497.50

Context: 4

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC196

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-67)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC196
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 454
- Grade Unit: ppm
- Intercept: 5 m
- From: 11 m
- To: 16 m
- Hole Depth: 21 m
- Intercept Depth: 11 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC196:11-16
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284801
- Northing: 7894921
- Elevation: 556 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(454 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 454.00

Context: 5

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC223

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-68)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC223
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 494
- Grade Unit: ppm
- Intercept: 1 m
- From: 11 m
- To: 12 m
- Hole Depth: 24 m
- Intercept Depth: 11 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC223:11-12
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284760
- Northing: 7894697
- Elevation: 541.7 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade but narrow scandium intercept was identified in historical drilling, indicating localized high-grade potential.

- Positive factor: High-grade scandium intercept \(494 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: Narrow width \(1 m\)

- Negative factor: True width not established

Evidence · table

> 494.00

Context: 1

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC223

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-69)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC223
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 388.17
- Grade Unit: ppm
- Intercept: 6 m
- From: 8 m
- To: 14 m
- Hole Depth: 24 m
- Intercept Depth: 8 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC223:8-14
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284760
- Northing: 7894697
- Elevation: 541.7 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept from shallow depths was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(388.17 ppm Sc\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 388.17

Context: 6

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-1044

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-70)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-1044
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 492.25
- Grade Unit: ppm
- Intercept: 4 m
- From: 9 m
- To: 13 m
- Hole Depth: 25 m
- Intercept Depth: 9 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-1044:9-13
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307453
- Northing: 7948310
- Elevation: 603.9 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept from shallow depths highlights strong potential.

- Positive factor: High-grade scandium intercept \(492.25 ppm Sc\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 492.25

Context: 4

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC014

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-71)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC014
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 487.78
- Grade Unit: ppm
- Intercept: 9 m
- From: 12 m
- To: 21 m
- Hole Depth: 30 m
- Intercept Depth: 12 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC014:12-21
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284703
- Northing: 7894180
- Elevation: 545.9 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade and wide scandium intercept highlights strong potential.

- Positive factor: High-grade scandium intercept \(487.78 ppm Sc\)

- Positive factor: Good width \(9 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 487.78

Context: 9

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC014

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-72)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC014
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 466.8
- Grade Unit: ppm
- Intercept: 10 m
- From: 12 m
- To: 22 m
- Hole Depth: 30 m
- Intercept Depth: 12 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC014:12-22
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284703
- Northing: 7894180
- Elevation: 545.9 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(466.8 ppm Sc\)

- Positive factor: Good width \(10 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 466.80

Context: 10

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC282

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-73)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC282
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 486.4
- Grade Unit: ppm
- Intercept: 5 m
- From: 15 m
- To: 20 m
- Hole Depth: 24 m
- Intercept Depth: 15 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC282:15-20
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284519
- Northing: 7894042
- Elevation: 553.8 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(486.4 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 486.40

Context: 5

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC138

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-74)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC138
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 483
- Grade Unit: ppm
- Intercept: 5 m
- From: 14 m
- To: 19 m
- Hole Depth: 27 m
- Intercept Depth: 14 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC138:14-19
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284703
- Northing: 7894158
- Elevation: 546.3 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(483 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 483.00

Context: 5

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC138

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-75)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC138
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 451.67
- Grade Unit: ppm
- Intercept: 6 m
- From: 13 m
- To: 19 m
- Hole Depth: 27 m
- Intercept Depth: 13 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC138:13-19
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284703
- Northing: 7894158
- Elevation: 546.3 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(451.67 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 451.67

Context: 6

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-828

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-76)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-828
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 481.43
- Grade Unit: ppm
- Intercept: 14 m
- From: 15 m
- To: 29 m
- Hole Depth: 40 m
- Intercept Depth: 15 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-828:15-29
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307619
- Northing: 7948903
- Elevation: 599.7 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade and wide scandium intercept highlights strong potential.

- Positive factor: High-grade scandium intercept \(481.43 ppm Sc\)

- Positive factor: Good width \(14 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 481.43

Context: 14

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-828

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-77)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-828
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 464.27
- Grade Unit: ppm
- Intercept: 15 m
- From: 15 m
- To: 30 m
- Hole Depth: 40 m
- Intercept Depth: 15 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-828:15-30
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307619
- Northing: 7948903
- Elevation: 599.7 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(464.27 ppm Sc\)

- Positive factor: Good width \(15 m\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 464.27

Context: 15

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC150

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-78)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC150
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 478
- Grade Unit: ppm
- Intercept: 2 m
- From: 12 m
- To: 14 m
- Hole Depth: 24 m
- Intercept Depth: 12 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC150:12-14
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284663
- Northing: 7894243
- Elevation: 544 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade but narrow scandium intercept was identified in historical drilling, indicating localized high-grade potential.

- Positive factor: High-grade scandium intercept \(478 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: Narrow width \(2 m\)

- Negative factor: True width not established

Evidence · table

> 478.00

Context: 2

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC150

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-79)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC150
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 392.4
- Grade Unit: ppm
- Intercept: 5 m
- From: 11 m
- To: 16 m
- Hole Depth: 24 m
- Intercept Depth: 11 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC150:11-16
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284663
- Northing: 7894243
- Elevation: 544 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(392.4 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 392.40

Context: 5

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC423

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-80)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC423
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 470.71
- Grade Unit: ppm
- Intercept: 7 m
- From: 7 m
- To: 14 m
- Hole Depth: 36 m
- Intercept Depth: 7 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC423:7-14
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284760.6
- Northing: 7894743.3
- Elevation: 543.1 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept from shallow depths highlights strong potential.

- Positive factor: High-grade scandium intercept \(470.71 ppm Sc\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 470.71

Context: 7

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC423

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-81)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC423
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 435.89
- Grade Unit: ppm
- Intercept: 9 m
- From: 5 m
- To: 14 m
- Hole Depth: 36 m
- Intercept Depth: 5 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC423:5-14
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284760.6
- Northing: 7894743.3
- Elevation: 543.1 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept from shallow depths was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(435.89 ppm Sc\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 435.89

Context: 9

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-249

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-82)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-249
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 412.86
- Grade Unit: ppm
- Intercept: 7 m
- From: 10 m
- To: 17 m
- Hole Depth: 30 m
- Intercept Depth: 10 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-249:10-17
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307637
- Northing: 7948902.1
- Elevation: 599.1 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(412.86 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 412.86

Context: 7

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC139

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-83)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC139
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 465.5
- Grade Unit: ppm
- Intercept: 4 m
- From: 17 m
- To: 21 m
- Hole Depth: 27 m
- Intercept Depth: 17 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC139:17-21
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284741
- Northing: 7894162
- Elevation: 546 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(465.5 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 465.50

Context: 4

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC139

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-84)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC139
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 418
- Grade Unit: ppm
- Intercept: 6 m
- From: 16 m
- To: 22 m
- Hole Depth: 27 m
- Intercept Depth: 16 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC139:16-22
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284741
- Northing: 7894162
- Elevation: 546 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(418 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 418.00

Context: 6

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC347

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-85)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC347
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 464.67
- Grade Unit: ppm
- Intercept: 3 m
- From: 17 m
- To: 20 m
- Hole Depth: 26 m
- Intercept Depth: 17 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC347:17-20
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284566.8
- Northing: 7894300
- Elevation: 543 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(464.67 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 464.67

Context: 3

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC347

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-86)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC347
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 417.33
- Grade Unit: ppm
- Intercept: 6 m
- From: 14 m
- To: 20 m
- Hole Depth: 26 m
- Intercept Depth: 14 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC347:14-20
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284566.8
- Northing: 7894300
- Elevation: 543 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(417.33 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 417.33

Context: 6

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-861

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-87)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-861
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 457.8
- Grade Unit: ppm
- Intercept: 5 m
- From: 15 m
- To: 20 m
- Hole Depth: 31 m
- Intercept Depth: 15 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-861:15-20
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307414
- Northing: 7948184
- Elevation: 603.6 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(457.8 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 457.80

Context: 5

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-284

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-88)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-284
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 464
- Grade Unit: ppm
- Intercept: 4 m
- From: 17 m
- To: 21 m
- Hole Depth: 46 m
- Intercept Depth: 17 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-284:17-21
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307079.8
- Northing: 7947402.8
- Elevation: 596.4 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A high-grade scandium intercept was identified in historical drilling, indicating strong potential.

- Positive factor: High-grade scandium intercept \(464 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 464.00

Context: 4

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### KK-284

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-89)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: KK-284
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 432.6
- Grade Unit: ppm
- Intercept: 5 m
- From: 16 m
- To: 21 m
- Hole Depth: 46 m
- Intercept Depth: 16 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: KK-284:16-21
- Mining Method: unknown

#### Location

- Location: Kokomo
- Easting: 307079.8
- Northing: 7947402.8
- Elevation: 596.4 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(432.6 ppm Sc\)

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 432.60

Context: 5

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC216

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-90)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC216
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 458.86
- Grade Unit: ppm
- Intercept: 7 m
- From: 10 m
- To: 17 m
- Hole Depth: 24 m
- Intercept Depth: 10 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC216:10-17
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284798
- Northing: 7894778
- Elevation: 547.4 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant high-grade scandium intercept from shallow depths was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(458.86 ppm Sc\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 458.86

Context: 7

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

### LKRC089

[Link to this fact](https://atlas-aws.minestarters.com/news/auz-sconi-overlooked-scandium-potential--d88b64e1-7a86-4a10-aa5b-5526ca837b9e#fact-drill-facts-91)

Sconi · scandium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: LKRC089
- Project: Sconi
- Commodity: scandium
- Region: australia\_qld
- Reported Region: australia\_qld
- Ticker: AUZ

#### Geometry

- Grade: 458.67
- Grade Unit: ppm
- Intercept: 9 m
- From: 3 m
- To: 12 m
- Hole Depth: 15 m
- Intercept Depth: 3 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: LKRC089:3-12
- Mining Method: unknown

#### Location

- Location: Lucknow
- Easting: 284840
- Northing: 7894936
- Elevation: 555 m
- Azimuth: 0 °
- Dip: -90 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- QP Signed: Yes

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Compositing

- Cutoff Grade: 300
- Cutoff Unit: ppm Sc

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-11-12T00:00:00.000Z

Reasoning: A significant shallow, high-grade scandium intercept was identified in historical drilling, indicating potential.

- Positive factor: High-grade scandium intercept \(458.67 ppm Sc\)

- Positive factor: Good width \(9 m\)

- Positive factor: Shallow mineralization

- Positive factor: Located on granted mining lease

- Negative factor: Historical data, no new assays

- Negative factor: True width not established

Evidence · table

> 458.67

Context: 9

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sconi lies approximately 220 km from Townsville, with major arterial roads and a telephone line within 1 km of the proje"

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.
