Arizona Gold & Silver Extends High Grade Discovery on the Philadelphia Project, Arizona with Drill Intercept of 12.65 Metres at 5.22 g/t Gold
Original announcement by orestocks on
- Company
- Arizona Gold & Silver Inc.
- Ticker
- AZS
- Exchange
- Unavailable
- Region
- Arizona
- Primary commodity
- Gold
- Secondary commodities
- Silver
- Document categories
- Drill results
- Extracted
- 2026-11-18 12:21:23 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Arizona Gold & Silver has reported significant high-grade gold-silver drill results from the Philadelphia Project in Arizona. Notably, hole PC26-175 intersected 12.65 metres at 5.22 g/t gold, confirming the presence of a high-grade upflow zone.
Reasoning: Strong high-grade gold intercepts that confirm geological models and extend the discovery footprint.
Positive factors
- High-grade intercept of 5.22 g/t Au over 12.65 m
- Bonanza-style interval of 59.11 g/t Au
- Confirms interpreted upflow zone/plunge
- QA/QC disclosed with certified lab and QP sign-off
Facts used in scoring: 12

Classification and evidence
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: 0.91 m at 59.11 g/t gold is exceptionally high grade.
Evidence · text
“high-grade interval of 0.91 m at 59.11 g/t gold”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release mentions Skyline Assayers, ISO 9001, and use of standards and blanks.
Evidence · text
“The Company’s QA/QC program includes the regular insertion of certified reference materials and blanks”
Extracted facts
Stored fact records: 12. Some facts used in scoring do not have a stored record.
Drill Results (12)
PC26-175Philadelphia · goldGrade: 5.22Grade Unit: g/tIntercept: 12.65 mView all detailsHide details
Identity
- Hole ID
- PC26-175
- Project
- Philadelphia
- Commodity
- gold
- Region
- usa_az
- Reported Region
- usa_az
- Ticker
- AZS
Geometry
- Grade
- 5.22
- Grade Unit
- g/t
- Intercept
- 12.65 m
- From
- 483.26 m
- To
- 495.91 m
- Intercept Depth
- 483.26 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- PC26-175:483.26-495.91
- Mining Method
- underground
Location
- Location
- Perry Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Skyline Assayers & Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-18T00:00:00.000Z
Reasoning: High-grade intercept confirming upflow zone.
Positive factors
- Strong grade and width
Evidence · text
“PC26-175 intersected 12.65 m at 5.22 g/t gold and 21.4 g/t silver”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PC26-175Philadelphia · silverGrade: 21.4Grade Unit: g/tIntercept: 12.65 mView all detailsHide details
Identity
- Hole ID
- PC26-175
- Project
- Philadelphia
- Commodity
- silver
- Region
- usa_az
- Reported Region
- usa_az
- Ticker
- AZS
Geometry
- Grade
- 21.4
- Grade Unit
- g/t
- Intercept
- 12.65 m
- From
- 483.26 m
- To
- 495.91 m
- Intercept Depth
- 483.26 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- PC26-175:483.26-495.91
- Mining Method
- underground
Location
- Location
- Perry Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Skyline Assayers & Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-18T00:00:00.000Z
Reasoning: Silver credits accompanying high-grade gold.
Evidence · text
“12.65 m at 5.22 g/t gold and 21.4 g/t silver”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PC26-175Philadelphia · goldGrade: 46.7Grade Unit: g/tIntercept: 0.91 mView all detailsHide details
Identity
- Hole ID
- PC26-175
- Project
- Philadelphia
- Commodity
- gold
- Region
- usa_az
- Reported Region
- usa_az
- Ticker
- AZS
Geometry
- Grade
- 46.7
- Grade Unit
- g/t
- Intercept
- 0.91 m
- From
- 483.26 m
- To
- 484.17 m
- Intercept Depth
- 483.26 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- PC26-175:483.26-484.17
- Mining Method
- underground
Location
- Location
- Perry Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Skyline Assayers & Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-18T00:00:00.000Z
Reasoning: Extremely high grade interval.
Positive factors
- Bonanza grade
Evidence · text
“high-grade interval of 0.91 m at 59.11 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PC26-175Philadelphia · goldGrade: 1.2Grade Unit: g/tIntercept: 100.58 mView all detailsHide details
Identity
- Hole ID
- PC26-175
- Project
- Philadelphia
- Commodity
- gold
- Region
- usa_az
- Reported Region
- usa_az
- Ticker
- AZS
Geometry
- Grade
- 1.2
- Grade Unit
- g/t
- Intercept
- 100.58 m
- From
- 413.61 m
- To
- 514.2 m
- Intercept Depth
- 413.61 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- PC26-175:413.61-514.2
- Mining Method
- underground
Location
- Location
- Perry Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Skyline Assayers & Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-18T00:00:00.000Z
Reasoning: Broad mineralized envelope.
Evidence · text
“100.58 metres at 1.20 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PC26-174Philadelphia · goldGrade: 0.64Grade Unit: g/tIntercept: 30.6 mView all detailsHide details
Identity
- Hole ID
- PC26-174
- Project
- Philadelphia
- Commodity
- gold
- Region
- usa_az
- Reported Region
- usa_az
- Ticker
- AZS
Geometry
- Grade
- 0.64
- Grade Unit
- g/t
- Intercept
- 30.6 m
- From
- 486.77 m
- To
- 517.37 m
- Intercept Depth
- 486.77 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- PC26-174:486.77-517.37
- Mining Method
- underground
Location
- Location
- Perry Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Skyline Assayers & Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-18T00:00:00.000Z
Reasoning: Lower grade intercept interpreted as peripheral.
Negative factors
- Weaker mineralization
Evidence · text
“PC26-174 intersected 30.60 m at 0.64 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PC26-175Philadelphia · silverGrade: 58.7Grade Unit: g/tIntercept: 0.91 mView all detailsHide details
Identity
- Hole ID
- PC26-175
- Project
- Philadelphia
- Commodity
- silver
- Region
- usa_az
- Reported Region
- usa_az
- Ticker
- AZS
Geometry
- Grade
- 58.7
- Grade Unit
- g/t
- Intercept
- 0.91 m
- From
- 483.26 m
- To
- 484.17 m
- Intercept Depth
- 483.26 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- PC26-175:483.26-484.17
- Mining Method
- underground
QA/QC
- Laboratory
- Skyline Assayers & Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-18T00:00:00.000Z
Reasoning: Expanded from assay table. 58.7 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 53.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“58.7”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
withinHigher grade mineralization is increasingly important as we push deeper into the · goldGrade: 2.01Grade Unit: g/tIntercept: 50.29 mView all detailsHide details
Identity
- Hole ID
- within
- Project
- Higher grade mineralization is increasingly important as we push deeper into the
- Commodity
- gold
- Region
- usa_az
- Reported Region
- usa_az
- Ticker
- AZS
Geometry
- Grade
- 2.01
- Grade Unit
- g/t
- Intercept
- 50.29 m
- From
- 447.14 m
- To
- 497.43 m
- Intercept Depth
- 447.14 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- within:447.14-497.43
- Mining Method
- underground
QA/QC
- Laboratory
- Skyline Assayers & Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-18T00:00:00.000Z
Reasoning: Expanded from assay table. 2.01 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 101.1 g/t·m is strong (grade alone is below; the better of the two is used).
Positive factors
- 2.01 g/t gold is strong on the underground mining band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.01”
Context: within
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
withinHigher grade mineralization is increasingly important as we push deeper into the · silverGrade: 11.1Grade Unit: g/tIntercept: 50.29 mView all detailsHide details
Identity
- Hole ID
- within
- Project
- Higher grade mineralization is increasingly important as we push deeper into the
- Commodity
- silver
- Region
- usa_az
- Reported Region
- usa_az
- Ticker
- AZS
Geometry
- Grade
- 11.1
- Grade Unit
- g/t
- Intercept
- 50.29 m
- From
- 447.14 m
- To
- 497.43 m
- Intercept Depth
- 447.14 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- within:447.14-497.43
- Mining Method
- underground
QA/QC
- Laboratory
- Skyline Assayers & Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-18T00:00:00.000Z
Reasoning: Expanded from assay table. 11.1 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 558.2 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“11.1”
Context: within
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
withinHigher grade mineralization is increasingly important as we push deeper into the · goldGrade: 1.2Grade Unit: g/tIntercept: 100.59 mView all detailsHide details
Identity
- Hole ID
- within
- Project
- Higher grade mineralization is increasingly important as we push deeper into the
- Commodity
- gold
- Region
- usa_az
- Reported Region
- usa_az
- Ticker
- AZS
Geometry
- Grade
- 1.2
- Grade Unit
- g/t
- Intercept
- 100.59 m
- From
- 413.61 m
- To
- 514.2 m
- Intercept Depth
- 413.61 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- within:413.61-514.2
- Mining Method
- underground
QA/QC
- Laboratory
- Skyline Assayers & Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-18T00:00:00.000Z
Reasoning: Expanded from assay table. 1.2 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 120.7 g/t·m is strong (grade alone is below; the better of the two is used).
Positive factors
- 1.2 g/t gold is strong on the underground mining band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.20”
Context: within
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
withinHigher grade mineralization is increasingly important as we push deeper into the · silverGrade: 6.8Grade Unit: g/tIntercept: 100.59 mView all detailsHide details
Identity
- Hole ID
- within
- Project
- Higher grade mineralization is increasingly important as we push deeper into the
- Commodity
- silver
- Region
- usa_az
- Reported Region
- usa_az
- Ticker
- AZS
Geometry
- Grade
- 6.8
- Grade Unit
- g/t
- Intercept
- 100.59 m
- From
- 413.61 m
- To
- 514.2 m
- Intercept Depth
- 413.61 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- within:413.61-514.2
- Mining Method
- underground
QA/QC
- Laboratory
- Skyline Assayers & Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-18T00:00:00.000Z
Reasoning: Expanded from assay table. 6.8 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 684.0 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.8”
Context: within
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PC26-174Philadelphia · goldGrade: 1.39Grade Unit: g/tIntercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- PC26-174
- Project
- Philadelphia
- Commodity
- gold
- Region
- usa_az
- Reported Region
- usa_az
- Ticker
- AZS
Geometry
- Grade
- 1.39
- Grade Unit
- g/t
- Intercept
- 6.1 m
- From
- 492.86 m
- To
- 498.96 m
- Intercept Depth
- 492.86 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- PC26-174:492.86-498.96
- Mining Method
- underground
QA/QC
- Laboratory
- Skyline Assayers & Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-18T00:00:00.000Z
Reasoning: Expanded from assay table. 1.39 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 8.5 g/t·m is below.
Negative factors
- 1.39 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.39”
Context: PC26-174
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PC26-174Philadelphia · silverGrade: 17.3Grade Unit: g/tIntercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- PC26-174
- Project
- Philadelphia
- Commodity
- silver
- Region
- usa_az
- Reported Region
- usa_az
- Ticker
- AZS
Geometry
- Grade
- 17.3
- Grade Unit
- g/t
- Intercept
- 6.1 m
- From
- 492.86 m
- To
- 498.96 m
- Intercept Depth
- 492.86 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- PC26-174:492.86-498.96
- Mining Method
- underground
QA/QC
- Laboratory
- Skyline Assayers & Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-18T00:00:00.000Z
Reasoning: Expanded from assay table. 17.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 105.5 g/t·m is below.
Negative factors
- 17.3 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“17.3”
Context: PC26-174
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.