# ANX: Quarterly Activities/Appendix 5B Cash Flow Report

Canonical Atlas analysis: https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3

Original source: https://www.asx.com.au/asx/v2/statistics/displayAnnouncement.do?display=pdf&idsId=03156966

Publisher: asx

Original announcement: 2026-10-25T22:39:00.000Z

Analysis by Minestarters Atlas

Atlas analysis published: 2026-10-25T23:31:18.598Z

Atlas analysis updated: 2026-10-25T23:31:18.598Z

- Company: Anax Metals Limited

- Ticker: ANX

- Exchange: ASX

- Region: Pilbara, Western Australia

- Primary commodity: Unavailable

- Secondary commodities: None reported

- Document categories: Drill results, Resource update, Other

- Extracted: 2026-10-25 23:18:31 UTC

Narrative sentiment: 0.80 · Bullish

## Minestarters Atlas summary

Anax Metals reported exceptional high-grade drill intercepts from its Mons Cupri deposit, including 85.9m at 2.89% CuEq, as part of its September 2026 quarterly activities. The company also announced a 24% increase in the Mons Cupri Mineral Resource to 6.32Mt at 1.38% CuEq, with 78% in the Measured and Indicated categories. Further progress includes advancing Front-End Engineering Design \(FEED\) for the sulphide concentrator and positive column testwork results supporting a heap leach feasibility study at the Whim Creek Project.

Reasoning: The company reported exceptional high-grade drill results and a significant increase in the Mons Cupri Mineral Resource, alongside positive metallurgical testwork and project development progress, indicating strong advancement for the Whim Creek Project.

- Positive factor: Exceptional high-grade drill intercepts at Mons Cupri, significantly exceeding project averages and peer benchmarks for VMS copper deposits.

- Positive factor: Substantial increase in Mons Cupri Mineral Resource \(24% tonnage, 20% contained CuEq metal\) with a high Measured and Indicated component \(78%\).

- Positive factor: Positive metallurgical column testwork results for copper and zinc extraction from lower-grade ores, supporting the heap leach strategy.

- Positive factor: Advancement of Front-End Engineering Design \(FEED\) and commencement of a heap leach feasibility study, indicating progress towards project development.

- Negative factor: Drill intercepts reported as downhole widths only, with true widths not determined, which may overstate actual thickness.

- Negative factor: The global resource update includes historical estimates for some deposits, and the new Mons Cupri resource has not yet been incorporated into the Ore Reserve.

- Negative factor: Metallurgical testwork is at the column test stage, not yet pilot scale, indicating further de-risking is required.

Facts used in scoring: 61

## Classification and evidence

No classification tags are available.

## Extracted facts

Stored fact records: 61. Some facts used in scoring do not have a stored record.

## Drill Results (55)

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-0)

Whim Creek · copper

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: copper
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 1.36
- Grade Unit: %
- Intercept: 85.9 m
- From: 34.6 m
- To: 120.5 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:34.6-120.5
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 2.89
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This is a strong, wide intercept with good copper equivalent grade, indicating significant mineralization, but the lack of true width information introduces some uncertainty.

- Positive factor: Significant intercept length of 85.9m at a strong copper equivalent grade of 2.89% CuEq, well above the VMS copper deposit average.

- Positive factor: High-grade copper and gold components contribute to the overall value.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 1.36

Context: 85.90

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-1)

Whim Creek · zinc

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: zinc
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 2.18
- Grade Unit: %
- Intercept: 85.9 m
- From: 34.6 m
- To: 120.5 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:34.6-120.5
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 2.89
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The zinc grade is a positive contributor to the overall polymetallic intercept, but the lack of true width information introduces some uncertainty.

- Positive factor: Good zinc grade over a significant intercept length, contributing to the polymetallic nature of the mineralization.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 2.18

Context: 85.90

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-2)

Whim Creek · lead

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: lead
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.79
- Grade Unit: %
- Intercept: 85.9 m
- From: 34.6 m
- To: 120.5 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:34.6-120.5
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 2.89
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The lead grade adds to the overall value of the polymetallic intercept, but the lack of true width information introduces some uncertainty.

- Positive factor: Lead grade contributes to the polymetallic nature of the mineralization over a significant intercept length.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.79

Context: 85.90

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-3)

Whim Creek · silver

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: silver
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 35.7
- Grade Unit: g/t
- Intercept: 85.9 m
- From: 34.6 m
- To: 120.5 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:34.6-120.5
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 2.89
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of the polymetallic intercept, but the lack of true width information introduces some uncertainty.

- Positive factor: Silver grade contributes to the polymetallic nature of the mineralization over a significant intercept length.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 35.7

Context: 85.90

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-4)

Whim Creek · gold

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: gold
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 1.05
- Grade Unit: g/t
- Intercept: 85.9 m
- From: 34.6 m
- To: 120.5 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:34.6-120.5
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 2.89
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The gold grade adds to the overall value of the polymetallic intercept, but the lack of true width information introduces some uncertainty.

- Positive factor: Gold grade contributes to the polymetallic nature of the mineralization over a significant intercept length.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 1.05

Context: 85.90

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-5)

Whim Creek · copper

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: copper
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 1.54
- Grade Unit: %
- Intercept: 4.7 m
- From: 34.6 m
- To: 39.3 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:34.6-39.3
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 8.34
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This sub-interval represents bonanza grades, particularly for zinc and lead, making it an exceptional result within the broader intercept.

- Positive factor: Exceptional high-grade copper equivalent of 8.34% CuEq over a moderate width, significantly contributing to the overall intercept value.

- Positive factor: High zinc and lead grades further enhance the value of this sub-interval.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 1.54

Context: 4.70

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The copper equivalent grade of 8.34% CuEq over 4.7m is exceptionally high for a VMS deposit.

Evidence · table

> 8.34

Context: 4.70

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-6)

Whim Creek · zinc

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: zinc
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 19.99
- Grade Unit: %
- Intercept: 4.7 m
- From: 34.6 m
- To: 39.3 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:34.6-39.3
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 8.34
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This high-grade zinc intercept is a key driver of the exceptional copper equivalent grade in this sub-interval.

- Positive factor: Exceptional high-grade zinc of 19.99% over 4.7m, significantly above the VMS zinc deposit average, contributing to the overall bonanza grade of the sub-interval.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 19.99

Context: 4.70

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The zinc grade of 19.99% over 4.7m is exceptionally high for a VMS deposit.

Evidence · table

> 19.99

Context: 4.70

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-7)

Whim Creek · lead

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: lead
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 9.07
- Grade Unit: %
- Intercept: 4.7 m
- From: 34.6 m
- To: 39.3 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:34.6-39.3
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 8.34
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This high-grade lead intercept is a key driver of the exceptional copper equivalent grade in this sub-interval.

- Positive factor: Exceptional high-grade lead of 9.07% over 4.7m, significantly above the VMS lead deposit average, contributing to the overall bonanza grade of the sub-interval.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 9.07

Context: 4.70

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The lead grade of 9.07% over 4.7m is exceptionally high for a VMS deposit.

Evidence · table

> 9.07

Context: 4.70

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-8)

Whim Creek · silver

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: silver
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 174.5
- Grade Unit: g/t
- Intercept: 4.7 m
- From: 34.6 m
- To: 39.3 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:34.6-39.3
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 8.34
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds significant value to this high-grade sub-interval, enhancing the polymetallic nature of the mineralization.

- Positive factor: Strong silver grade of 174.5 g/t over 4.7m, contributing to the overall bonanza grade of the sub-interval.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 174.5

Context: 4.70

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-9)

Whim Creek · gold

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: gold
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.54
- Grade Unit: g/t
- Intercept: 4.7 m
- From: 34.6 m
- To: 39.3 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:34.6-39.3
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 8.34
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The gold grade adds to the overall value of this high-grade sub-interval, enhancing the polymetallic nature of the mineralization.

- Positive factor: Gold grade contributes to the polymetallic nature of the mineralization within this high-grade sub-interval.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.54

Context: 4.70

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-10)

Whim Creek · copper

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: copper
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 4.74
- Grade Unit: %
- Intercept: 17.5 m
- From: 39.3 m
- To: 56.8 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:39.3-56.8
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 8.37
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This sub-interval represents bonanza grades with very high copper and gold, making it an exceptional result within the broader intercept.

- Positive factor: Exceptional high-grade copper equivalent of 8.37% CuEq over a significant width of 17.5m, indicating a very strong mineralized zone.

- Positive factor: High copper and gold grades are key contributors to this bonanza intercept.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 4.74

Context: 17.50

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The copper equivalent grade of 8.37% CuEq over 17.5m is exceptionally high for a VMS deposit.

Evidence · table

> 8.37

Context: 17.50

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-11)

Whim Creek · zinc

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: zinc
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.29
- Grade Unit: %
- Intercept: 17.5 m
- From: 39.3 m
- To: 56.8 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:39.3-56.8
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 8.37
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: While part of a high-grade intercept, the zinc grade itself is weak and does not significantly contribute to the overall value.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Zinc grade is relatively low for a VMS deposit, not a primary contributor to the high CuEq.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.29

Context: 17.50

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-12)

Whim Creek · lead

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: lead
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 17.5 m
- From: 39.3 m
- To: 56.8 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:39.3-56.8
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 8.37
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: While part of a high-grade intercept, the lead grade itself is weak and does not significantly contribute to the overall value.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Lead grade is relatively low for a VMS deposit, not a primary contributor to the high CuEq.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.12

Context: 17.50

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-13)

Whim Creek · silver

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: silver
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 47.3
- Grade Unit: g/t
- Intercept: 17.5 m
- From: 39.3 m
- To: 56.8 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:39.3-56.8
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 8.37
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of this high-grade sub-interval, enhancing the polymetallic nature of the mineralization.

- Positive factor: Silver grade contributes to the polymetallic nature of the mineralization within this high-grade sub-interval.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 47.3

Context: 17.50

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-14)

Whim Creek · gold

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: gold
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 4.75
- Grade Unit: g/t
- Intercept: 17.5 m
- From: 39.3 m
- To: 56.8 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:39.3-56.8
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 8.37
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This high-grade gold intercept is a key driver of the exceptional copper equivalent grade in this sub-interval.

- Positive factor: Exceptional high-grade gold of 4.75 g/t over 17.5m, significantly contributing to the overall bonanza grade of the sub-interval.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 4.75

Context: 17.50

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The gold grade of 4.75 g/t over 17.5m is exceptionally high for a VMS deposit.

Evidence · table

> 4.75

Context: 17.50

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-15)

Whim Creek · copper

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: copper
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 8.5 m
- From: 112 m
- To: 120.5 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:112-120.5
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This sub-interval shows moderate copper equivalent grade, primarily driven by zinc and silver, but the copper grade itself is weak.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Copper grade is low, but the overall CuEq is moderate due to other metals.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.15

Context: 8.50

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-16)

Whim Creek · zinc

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: zinc
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 5.13
- Grade Unit: %
- Intercept: 8.5 m
- From: 112 m
- To: 120.5 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:112-120.5
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This sub-interval shows a moderate zinc grade, which is a key contributor to the overall copper equivalent value.

- Positive factor: Moderate zinc grade over a reasonable width, contributing significantly to the copper equivalent grade.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 5.13

Context: 8.50

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-17)

Whim Creek · lead

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: lead
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 1.03
- Grade Unit: %
- Intercept: 8.5 m
- From: 112 m
- To: 120.5 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:112-120.5
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The lead grade adds to the overall value of this sub-interval, enhancing the polymetallic nature of the mineralization.

- Positive factor: Lead grade contributes to the polymetallic nature of the mineralization within this sub-interval.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 1.03

Context: 8.50

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-18)

Whim Creek · silver

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: silver
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 35.2
- Grade Unit: g/t
- Intercept: 8.5 m
- From: 112 m
- To: 120.5 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:112-120.5
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of this sub-interval, enhancing the polymetallic nature of the mineralization.

- Positive factor: Silver grade contributes to the polymetallic nature of the mineralization within this sub-interval.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 35.2

Context: 8.50

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-19)

Whim Creek · gold

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: gold
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 8.5 m
- From: 112 m
- To: 120.5 m
- Intercept Depth: 34.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:112-120.5
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The gold grade in this sub-interval is weak and has minimal impact on the overall copper equivalent value.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Gold grade is very low and does not significantly contribute to the overall CuEq grade.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.04

Context: 8.50

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-20)

Whim Creek · copper

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: copper
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.94
- Grade Unit: %
- Intercept: 18.55 m
- From: 145.45 m
- To: 164 m
- Intercept Depth: 145.45 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:145.45-164
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.06
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This separate intercept shows moderate copper equivalent mineralization, extending the known zone, but lacks true width information.

- Positive factor: Moderate copper equivalent grade over a good width, indicating continued mineralization at depth.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.94

Context: 18.55

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-21)

Whim Creek · zinc

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: zinc
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 18.55 m
- From: 145.45 m
- To: 164 m
- Intercept Depth: 145.45 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:145.45-164
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.06
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The zinc grade in this intercept is weak and has minimal impact on the overall copper equivalent value.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Zinc grade is very low and does not significantly contribute to the overall CuEq grade.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.07

Context: 18.55

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-22)

Whim Creek · lead

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: lead
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 18.55 m
- From: 145.45 m
- To: 164 m
- Intercept Depth: 145.45 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:145.45-164
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.06
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The lead grade in this intercept is weak and has minimal impact on the overall copper equivalent value.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Lead grade is very low and does not significantly contribute to the overall CuEq grade.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.02

Context: 18.55

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-23)

Whim Creek · silver

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: silver
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 3.7
- Grade Unit: g/t
- Intercept: 18.55 m
- From: 145.45 m
- To: 164 m
- Intercept Depth: 145.45 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:145.45-164
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.06
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The silver grade in this intercept is weak and has minimal impact on the overall copper equivalent value.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Silver grade is low and does not significantly contribute to the overall CuEq grade.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 3.7

Context: 18.55

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD001

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-24)

Whim Creek · gold

#### Identity

- Hole ID: 26ANXDD001
- Project: Whim Creek
- Commodity: gold
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.09
- Grade Unit: g/t
- Intercept: 18.55 m
- From: 145.45 m
- To: 164 m
- Intercept Depth: 145.45 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD001:145.45-164
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.06
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The gold grade in this intercept is weak and has minimal impact on the overall copper equivalent value.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Gold grade is very low and does not significantly contribute to the overall CuEq grade.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.09

Context: 18.55

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD002

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-25)

Whim Creek · copper

Historical result

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD002
- Project: Whim Creek
- Commodity: copper
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 13 m
- From: 169 m
- To: 182 m
- Intercept Depth: 169 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD002:169-182
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 0.81
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This intercept shows very weak copper mineralization, contributing minimally to the overall copper equivalent grade.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Very low copper grade, indicating poor mineralization for this commodity.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.01

Context: 13.00

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD002

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-26)

Whim Creek · zinc

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD002
- Project: Whim Creek
- Commodity: zinc
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 2.3
- Grade Unit: %
- Intercept: 13 m
- From: 169 m
- To: 182 m
- Intercept Depth: 169 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD002:169-182
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 0.81
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This intercept shows a moderate zinc grade, which is a key contributor to the overall copper equivalent value.

- Positive factor: Moderate zinc grade over a reasonable width, contributing to the overall copper equivalent grade.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 2.30

Context: 13.00

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD002

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-27)

Whim Creek · lead

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD002
- Project: Whim Creek
- Commodity: lead
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.75
- Grade Unit: %
- Intercept: 13 m
- From: 169 m
- To: 182 m
- Intercept Depth: 169 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD002:169-182
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 0.81
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The lead grade adds to the overall value of this intercept, enhancing the polymetallic nature of the mineralization.

- Positive factor: Lead grade contributes to the polymetallic nature of the mineralization within this intercept.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.75

Context: 13.00

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD002

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-28)

Whim Creek · silver

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD002
- Project: Whim Creek
- Commodity: silver
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 26.5
- Grade Unit: g/t
- Intercept: 13 m
- From: 169 m
- To: 182 m
- Intercept Depth: 169 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD002:169-182
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 0.81
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of this intercept, enhancing the polymetallic nature of the mineralization.

- Positive factor: Silver grade contributes to the polymetallic nature of the mineralization within this intercept.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 26.5

Context: 13.00

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD002

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-29)

Whim Creek · gold

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD002
- Project: Whim Creek
- Commodity: gold
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 13 m
- From: 169 m
- To: 182 m
- Intercept Depth: 169 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD002:169-182
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 0.81
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This intercept shows very weak gold mineralization, contributing minimally to the overall copper equivalent grade.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Very low gold grade, indicating poor mineralization for this commodity.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.04

Context: 13.00

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-30)

Whim Creek · copper

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: copper
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 1.59
- Grade Unit: %
- Intercept: 62.54 m
- From: 107.32 m
- To: 169.86 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:107.32-169.86
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 2.95
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This is a strong, wide intercept with good copper equivalent grade, indicating significant mineralization, but the lack of true width information introduces some uncertainty.

- Positive factor: Strong copper equivalent grade of 2.95% CuEq over a significant width of 62.54m, indicating a substantial mineralized zone.

- Positive factor: High gold grade contributes significantly to the overall value.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 1.59

Context: 62.54

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-31)

Whim Creek · zinc

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: zinc
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 1.13
- Grade Unit: %
- Intercept: 62.54 m
- From: 107.32 m
- To: 169.86 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:107.32-169.86
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 2.95
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The zinc grade is a positive contributor to the overall polymetallic intercept, but the lack of true width information introduces some uncertainty.

- Positive factor: Moderate zinc grade over a significant intercept length, contributing to the polymetallic nature of the mineralization.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 1.13

Context: 62.54

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-32)

Whim Creek · lead

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: lead
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.41
- Grade Unit: %
- Intercept: 62.54 m
- From: 107.32 m
- To: 169.86 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:107.32-169.86
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 2.95
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The lead grade adds to the overall value of the polymetallic intercept, but the lack of true width information introduces some uncertainty.

- Positive factor: Lead grade contributes to the polymetallic nature of the mineralization over a significant intercept length.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.41

Context: 62.54

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-33)

Whim Creek · silver

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: silver
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 16.1
- Grade Unit: g/t
- Intercept: 62.54 m
- From: 107.32 m
- To: 169.86 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:107.32-169.86
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 2.95
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of the polymetallic intercept, but the lack of true width information introduces some uncertainty.

- Positive factor: Silver grade contributes to the polymetallic nature of the mineralization over a significant intercept length.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 16.1

Context: 62.54

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-34)

Whim Creek · gold

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: gold
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 1.46
- Grade Unit: g/t
- Intercept: 62.54 m
- From: 107.32 m
- To: 169.86 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:107.32-169.86
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 2.95
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The gold grade is a positive contributor to the overall polymetallic intercept, but the lack of true width information introduces some uncertainty.

- Positive factor: Moderate gold grade over a significant intercept length, contributing to the overall copper equivalent grade.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 1.46

Context: 62.54

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-35)

Whim Creek · copper

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: copper
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 2.22
- Grade Unit: %
- Intercept: 5.04 m
- From: 107.32 m
- To: 112.36 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:107.32-112.36
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 5.46
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This sub-interval represents bonanza grades, particularly for zinc and lead, making it an exceptional result within the broader intercept.

- Positive factor: Exceptional high-grade copper equivalent of 5.46% CuEq over a narrow width, indicating a very strong mineralized zone.

- Positive factor: High zinc and lead grades are key contributors to this bonanza intercept.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 2.22

Context: 5.04

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The copper equivalent grade of 5.46% CuEq over 5.04m is exceptionally high for a VMS deposit.

Evidence · table

> 5.46

Context: 5.04

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-36)

Whim Creek · zinc

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: zinc
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 9.8
- Grade Unit: %
- Intercept: 5.04 m
- From: 107.32 m
- To: 112.36 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:107.32-112.36
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 5.46
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This high-grade zinc intercept is a key driver of the exceptional copper equivalent grade in this sub-interval.

- Positive factor: Strong zinc grade of 9.80% over 5.04m, significantly contributing to the overall bonanza grade of the sub-interval.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 9.80

Context: 5.04

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The zinc grade of 9.80% over 5.04m is strong for a VMS deposit.

Evidence · table

> 9.80

Context: 5.04

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-37)

Whim Creek · lead

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: lead
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 3.54
- Grade Unit: %
- Intercept: 5.04 m
- From: 107.32 m
- To: 112.36 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:107.32-112.36
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 5.46
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This high-grade lead intercept is a key driver of the exceptional copper equivalent grade in this sub-interval.

- Positive factor: Strong lead grade of 3.54% over 5.04m, significantly contributing to the overall bonanza grade of the sub-interval.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 3.54

Context: 5.04

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The lead grade of 3.54% over 5.04m is strong for a VMS deposit.

Evidence · table

> 3.54

Context: 5.04

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-38)

Whim Creek · silver

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: silver
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 69.8
- Grade Unit: g/t
- Intercept: 5.04 m
- From: 107.32 m
- To: 112.36 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:107.32-112.36
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 5.46
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of this high-grade sub-interval, enhancing the polymetallic nature of the mineralization.

- Positive factor: Moderate silver grade over a narrow width, contributing to the overall bonanza grade of the sub-interval.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 69.8

Context: 5.04

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-39)

Whim Creek · gold

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: gold
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.49
- Grade Unit: g/t
- Intercept: 5.04 m
- From: 107.32 m
- To: 112.36 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:107.32-112.36
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 5.46
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The gold grade adds to the overall value of this high-grade sub-interval, enhancing the polymetallic nature of the mineralization.

- Positive factor: Gold grade contributes to the polymetallic nature of the mineralization within this high-grade sub-interval.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.49

Context: 5.04

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-40)

Whim Creek · copper

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: copper
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 2.62
- Grade Unit: %
- Intercept: 18.98 m
- From: 112.36 m
- To: 131.34 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:112.36-131.34
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 6.01
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This sub-interval represents bonanza grades with very high copper and gold, making it an exceptional result within the broader intercept.

- Positive factor: Exceptional high-grade copper equivalent of 6.01% CuEq over a significant width of 18.98m, indicating a very strong mineralized zone.

- Positive factor: High copper and gold grades are key contributors to this bonanza intercept.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 2.62

Context: 18.98

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The copper equivalent grade of 6.01% CuEq over 18.98m is exceptionally high for a VMS deposit.

Evidence · table

> 6.01

Context: 18.98

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-41)

Whim Creek · zinc

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: zinc
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.99
- Grade Unit: %
- Intercept: 18.98 m
- From: 112.36 m
- To: 131.34 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:112.36-131.34
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 6.01
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: While part of a high-grade intercept, the zinc grade itself is weak and does not significantly contribute to the overall value.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Zinc grade is relatively low for a VMS deposit, not a primary contributor to the high CuEq.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.99

Context: 18.98

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-42)

Whim Creek · lead

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: lead
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.38
- Grade Unit: %
- Intercept: 18.98 m
- From: 112.36 m
- To: 131.34 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:112.36-131.34
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 6.01
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: While part of a high-grade intercept, the lead grade itself is weak and does not significantly contribute to the overall value.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Lead grade is relatively low for a VMS deposit, not a primary contributor to the high CuEq.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.38

Context: 18.98

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-43)

Whim Creek · silver

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: silver
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 23.3
- Grade Unit: g/t
- Intercept: 18.98 m
- From: 112.36 m
- To: 131.34 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:112.36-131.34
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 6.01
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of this high-grade sub-interval, enhancing the polymetallic nature of the mineralization.

- Positive factor: Silver grade contributes to the polymetallic nature of the mineralization within this high-grade sub-interval.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 23.3

Context: 18.98

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD003

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-44)

Whim Creek · gold

Needs review: ungrounded

#### Identity

- Hole ID: 26ANXDD003
- Project: Whim Creek
- Commodity: gold
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 4.52
- Grade Unit: g/t
- Intercept: 18.98 m
- From: 112.36 m
- To: 131.34 m
- Intercept Depth: 107.32 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD003:112.36-131.34
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 6.01
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: ungrounded
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This high-grade gold intercept is a key driver of the exceptional copper equivalent grade in this sub-interval.

- Positive factor: Exceptional high-grade gold of 4.52 g/t over 18.98m, significantly contributing to the overall bonanza grade of the sub-interval.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 4.52

Context: 18.98

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The gold grade of 4.52 g/t over 18.98m is exceptionally high for a VMS deposit.

Evidence · table

> 4.52

Context: 18.98

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD004

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-45)

Whim Creek · copper

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: 26ANXDD004
- Project: Whim Creek
- Commodity: copper
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.29 m
- From: 110.79 m
- To: 111.08 m
- Intercept Depth: 110.79 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD004:110.79-111.08
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 3.48
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This is a very narrow intercept with a high copper equivalent grade, primarily driven by zinc and lead, but its limited width reduces its overall materiality.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Very narrow intercept length, limiting its overall significance.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.01

Context: 0.29

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD004

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-46)

Whim Creek · zinc

#### Identity

- Hole ID: 26ANXDD004
- Project: Whim Creek
- Commodity: zinc
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 6.34
- Grade Unit: %
- Intercept: 0.29 m
- From: 110.79 m
- To: 111.08 m
- Intercept Depth: 110.79 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD004:110.79-111.08
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 3.48
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This very narrow intercept shows a moderate zinc grade, which is a key contributor to the overall copper equivalent value, but its limited width reduces its overall materiality.

- Positive factor: Moderate zinc grade over a very narrow width, contributing significantly to the copper equivalent grade.

- Negative factor: Very narrow intercept length, limiting its overall significance.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 6.34

Context: 0.29

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD004

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-47)

Whim Creek · lead

#### Identity

- Hole ID: 26ANXDD004
- Project: Whim Creek
- Commodity: lead
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 11.15
- Grade Unit: %
- Intercept: 0.29 m
- From: 110.79 m
- To: 111.08 m
- Intercept Depth: 110.79 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD004:110.79-111.08
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 3.48
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This very narrow intercept shows an exceptional lead grade, which is a key driver of the overall copper equivalent value, but its limited width reduces its overall materiality.

- Positive factor: Exceptional high-grade lead of 11.15% over a very narrow width, significantly contributing to the copper equivalent grade.

- Negative factor: Very narrow intercept length, limiting its overall significance.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 11.15

Context: 0.29

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The lead grade of 11.15% over 0.29m is exceptionally high for a VMS deposit.

Evidence · table

> 11.15

Context: 0.29

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD004

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-48)

Whim Creek · silver

#### Identity

- Hole ID: 26ANXDD004
- Project: Whim Creek
- Commodity: silver
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 112
- Grade Unit: g/t
- Intercept: 0.29 m
- From: 110.79 m
- To: 111.08 m
- Intercept Depth: 110.79 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD004:110.79-111.08
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 3.48
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This very narrow intercept shows a strong silver grade, which is a key contributor to the overall copper equivalent value, but its limited width reduces its overall materiality.

- Positive factor: Strong silver grade of 112.0 g/t over a very narrow width, contributing significantly to the copper equivalent grade.

- Negative factor: Very narrow intercept length, limiting its overall significance.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 112.0

Context: 0.29

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD004

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-49)

Whim Creek · gold

#### Identity

- Hole ID: 26ANXDD004
- Project: Whim Creek
- Commodity: gold
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 0.29 m
- From: 110.79 m
- To: 111.08 m
- Intercept Depth: 110.79 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD004:110.79-111.08
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 3.48
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This very narrow intercept shows very weak gold mineralization, contributing minimally to the overall copper equivalent grade.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Very low gold grade, indicating poor mineralization for this commodity.

- Negative factor: Very narrow intercept length, limiting its overall significance.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.05

Context: 0.29

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD004

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-50)

Whim Creek · copper

#### Identity

- Hole ID: 26ANXDD004
- Project: Whim Creek
- Commodity: copper
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.81
- Grade Unit: %
- Intercept: 1.59 m
- From: 326.25 m
- To: 327.84 m
- Intercept Depth: 326.25 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD004:326.25-327.84
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.23
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This narrow intercept shows moderate copper equivalent mineralization, extending the known zone, but lacks true width information and is of limited width.

- Positive factor: Moderate copper equivalent grade over a narrow width, indicating continued mineralization at depth.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Narrow intercept length, limiting its overall significance.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.81

Context: 1.59

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD004

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-51)

Whim Creek · zinc

#### Identity

- Hole ID: 26ANXDD004
- Project: Whim Creek
- Commodity: zinc
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 1.28
- Grade Unit: %
- Intercept: 1.59 m
- From: 326.25 m
- To: 327.84 m
- Intercept Depth: 326.25 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD004:326.25-327.84
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.23
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This narrow intercept shows a moderate zinc grade, which is a key contributor to the overall copper equivalent value, but its limited width reduces its overall materiality.

- Positive factor: Zinc grade contributes to the polymetallic nature of the mineralization within this intercept.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Narrow intercept length, limiting its overall significance.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 1.28

Context: 1.59

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD004

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-52)

Whim Creek · lead

#### Identity

- Hole ID: 26ANXDD004
- Project: Whim Creek
- Commodity: lead
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 1.59 m
- From: 326.25 m
- To: 327.84 m
- Intercept Depth: 326.25 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD004:326.25-327.84
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.23
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This narrow intercept shows a weak lead grade, which has minimal impact on the overall copper equivalent value.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Lead grade is low and does not significantly contribute to the overall CuEq grade.

- Negative factor: Narrow intercept length, limiting its overall significance.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.17

Context: 1.59

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD004

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-53)

Whim Creek · silver

#### Identity

- Hole ID: 26ANXDD004
- Project: Whim Creek
- Commodity: silver
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 12.6
- Grade Unit: g/t
- Intercept: 1.59 m
- From: 326.25 m
- To: 327.84 m
- Intercept Depth: 326.25 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD004:326.25-327.84
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.23
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This narrow intercept shows a weak silver grade, which has minimal impact on the overall copper equivalent value.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Silver grade is low and does not significantly contribute to the overall CuEq grade.

- Negative factor: Narrow intercept length, limiting its overall significance.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 12.6

Context: 1.59

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

### 26ANXDD004

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-drill-facts-54)

Whim Creek · gold

#### Identity

- Hole ID: 26ANXDD004
- Project: Whim Creek
- Commodity: gold
- Region: australia\_wa
- Reported Region: australia\_wa
- Ticker: ANX

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 1.59 m
- From: 326.25 m
- To: 327.84 m
- Intercept Depth: 326.25 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: 26ANXDD004:326.25-327.84
- Mining Method: open\_pit

#### Location

- Location: Mons Cupri
- Loc. Source: document

#### QA/QC

- QP Signed: Yes
- QA/QC Methods: standards

#### Metal Equivalent

- Metal Eq. Grade: 1.23
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq
- Dilution Disclosed: Yes
- Max Dilution: 3 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: This narrow intercept shows very weak gold mineralization, contributing minimally to the overall copper equivalent grade.

- Positive factor: Part of a new drilling campaign targeting extensions and infill.

- Negative factor: Very low gold grade, indicating poor mineralization for this commodity.

- Negative factor: Narrow intercept length, limiting its overall significance.

- Negative factor: True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

> 0.04

Context: 1.59

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

#### Rejected tags

**Apparent Width Only** — Rejected; excluded from scoring

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

> Widths are downhole; true widths have not been determined.

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

> CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.

**Cut-off Disclosed** — Rejected; excluded from scoring

Polarity: positive

Story-specific tag

Definition: Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

> Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.

## Resource Estimates (6)

### measured

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-resource-facts-55)

Whim Creek Project · copper

#### Identity

- Project: Whim Creek Project
- Commodity: copper
- Region: australia\_wa
- Reported Region: Pilbara, Western Australia
- Ticker: ANX

#### Resource scope

- Estimate type: resource
- Effective date: 2026-10-13T00:00:00.000Z
- Reporting standards: jorc
- QP Signed: Yes
- Resource group id: resource:6b833237bf55f08382ce
- Deposit or zone: Mons Cupri
- Mining method: combined
- Ownership percent: 80 %
- Resource basis: gross

#### Resource Data

- Category: measured
- Tonnes: 1500000
- Grade: 1.22
- Grade Unit: %
- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq

#### Prior Estimate

- Resource Date: 2026-08-25

#### Metal Equivalent

- Metal Eq. Grade: 2.03
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The Measured resource for copper at Mons Cupri is a strong positive, demonstrating high confidence in a portion of the deposit.

- Positive factor: High confidence Measured category for copper, indicating robust geological understanding.

- Positive factor: Good copper grade contributing to a strong copper equivalent grade.

- Positive factor: Part of a significant resource update with overall tonnage and contained metal growth.

Evidence · table

> 1.22

Context: 1.5

#### Tags used in scoring

**No Contained Metal**

Polarity: negative

Definition: Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained\_metal was not reported

**No QP/CP Disclosure**

Polarity: negative

Definition: No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

**PEA-Supporting**

Polarity: neutral

Definition: Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

**DFS-Supporting**

Polarity: neutral

Definition: Resource estimate prepared to support a Definitive Feasibility Study — requires high M&amp;I confidence.

Why it applies: the release names the study this estimate supports

### measured

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-resource-facts-56)

Whim Creek Project · zinc

#### Identity

- Project: Whim Creek Project
- Commodity: zinc
- Region: australia\_wa
- Reported Region: Pilbara, Western Australia
- Ticker: ANX

#### Resource scope

- Estimate type: resource
- Effective date: 2026-10-13T00:00:00.000Z
- Reporting standards: jorc
- QP Signed: Yes
- Resource group id: resource:6b833237bf55f08382ce
- Deposit or zone: Mons Cupri
- Mining method: combined
- Ownership percent: 80 %
- Resource basis: gross

#### Resource Data

- Category: measured
- Tonnes: 1500000
- Grade: 1.41
- Grade Unit: %
- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq

#### Prior Estimate

- Resource Date: 2026-08-25

#### Metal Equivalent

- Metal Eq. Grade: 2.03
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The Measured resource for zinc at Mons Cupri is a positive, demonstrating high confidence in a portion of the deposit.

- Positive factor: High confidence Measured category for zinc, indicating robust geological understanding.

- Positive factor: Good zinc grade contributing to the overall copper equivalent grade.

- Positive factor: Part of a significant resource update with overall tonnage and contained metal growth.

Evidence · table

> 1.41

Context: 1.5

#### Tags used in scoring

**No Contained Metal**

Polarity: negative

Definition: Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained\_metal was not reported

**No QP/CP Disclosure**

Polarity: negative

Definition: No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

**PEA-Supporting**

Polarity: neutral

Definition: Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

**DFS-Supporting**

Polarity: neutral

Definition: Resource estimate prepared to support a Definitive Feasibility Study — requires high M&amp;I confidence.

Why it applies: the release names the study this estimate supports

### measured

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-resource-facts-57)

Whim Creek Project · lead

#### Identity

- Project: Whim Creek Project
- Commodity: lead
- Region: australia\_wa
- Reported Region: Pilbara, Western Australia
- Ticker: ANX

#### Resource scope

- Estimate type: resource
- Effective date: 2026-10-13T00:00:00.000Z
- Reporting standards: jorc
- QP Signed: Yes
- Resource group id: resource:6b833237bf55f08382ce
- Deposit or zone: Mons Cupri
- Mining method: combined
- Ownership percent: 80 %
- Resource basis: gross

#### Resource Data

- Category: measured
- Tonnes: 1500000
- Grade: 0.57
- Grade Unit: %
- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq

#### Prior Estimate

- Resource Date: 2026-08-25

#### Metal Equivalent

- Metal Eq. Grade: 2.03
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The Measured resource for lead at Mons Cupri is a positive, demonstrating high confidence in a portion of the deposit.

- Positive factor: High confidence Measured category for lead, indicating robust geological understanding.

- Positive factor: Good lead grade contributing to the overall copper equivalent grade.

- Positive factor: Part of a significant resource update with overall tonnage and contained metal growth.

Evidence · table

> 0.57

Context: 1.5

#### Tags used in scoring

**No Contained Metal**

Polarity: negative

Definition: Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained\_metal was not reported

**No QP/CP Disclosure**

Polarity: negative

Definition: No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

**PEA-Supporting**

Polarity: neutral

Definition: Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

**DFS-Supporting**

Polarity: neutral

Definition: Resource estimate prepared to support a Definitive Feasibility Study — requires high M&amp;I confidence.

Why it applies: the release names the study this estimate supports

### measured

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-resource-facts-58)

Whim Creek Project · silver

#### Identity

- Project: Whim Creek Project
- Commodity: silver
- Region: australia\_wa
- Reported Region: Pilbara, Western Australia
- Ticker: ANX

#### Resource scope

- Estimate type: resource
- Effective date: 2026-10-13T00:00:00.000Z
- Reporting standards: jorc
- QP Signed: Yes
- Resource group id: resource:6b833237bf55f08382ce
- Deposit or zone: Mons Cupri
- Mining method: combined
- Ownership percent: 80 %
- Resource basis: gross

#### Resource Data

- Category: measured
- Tonnes: 1500000
- Grade: 31
- Grade Unit: ppm
- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq

#### Prior Estimate

- Resource Date: 2026-08-25

#### Metal Equivalent

- Metal Eq. Grade: 2.03
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The Measured resource for silver at Mons Cupri is a positive, demonstrating high confidence in a portion of the deposit.

- Positive factor: High confidence Measured category for silver, indicating robust geological understanding.

- Positive factor: Good silver grade contributing to the overall copper equivalent grade.

- Positive factor: Part of a significant resource update with overall tonnage and contained metal growth.

Evidence · table

> 31

Context: 1.5

#### Tags used in scoring

**No Contained Metal**

Polarity: negative

Definition: Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained\_metal was not reported

**No QP/CP Disclosure**

Polarity: negative

Definition: No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

**PEA-Supporting**

Polarity: neutral

Definition: Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

**DFS-Supporting**

Polarity: neutral

Definition: Resource estimate prepared to support a Definitive Feasibility Study — requires high M&amp;I confidence.

Why it applies: the release names the study this estimate supports

### measured

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-resource-facts-59)

Whim Creek Project · gold

#### Identity

- Project: Whim Creek Project
- Commodity: gold
- Region: australia\_wa
- Reported Region: Pilbara, Western Australia
- Ticker: ANX

#### Resource scope

- Estimate type: resource
- Effective date: 2026-10-13T00:00:00.000Z
- Reporting standards: jorc
- QP Signed: Yes
- Resource group id: resource:6b833237bf55f08382ce
- Deposit or zone: Mons Cupri
- Mining method: combined
- Ownership percent: 80 %
- Resource basis: gross

#### Resource Data

- Category: measured
- Tonnes: 1500000
- Grade: 0.28
- Grade Unit: ppm
- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq

#### Prior Estimate

- Resource Date: 2026-08-25

#### Metal Equivalent

- Metal Eq. Grade: 2.03
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The Measured resource for gold at Mons Cupri is a positive, demonstrating high confidence in a portion of the deposit.

- Positive factor: High confidence Measured category for gold, indicating robust geological understanding.

- Positive factor: Good gold grade contributing to the overall copper equivalent grade.

- Positive factor: Part of a significant resource update with overall tonnage and contained metal growth.

Evidence · table

> 0.28

Context: 1.5

#### Tags used in scoring

**No Contained Metal**

Polarity: negative

Definition: Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained\_metal was not reported

**No QP/CP Disclosure**

Polarity: negative

Definition: No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

**PEA-Supporting**

Polarity: neutral

Definition: Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

**DFS-Supporting**

Polarity: neutral

Definition: Resource estimate prepared to support a Definitive Feasibility Study — requires high M&amp;I confidence.

Why it applies: the release names the study this estimate supports

### indicated

[Link to this fact](https://atlas-aws.minestarters.com/news/anx-quarterly-activities-appendix-5b-cash-flow-report--84d29e5e-a183-454b-b38b-85445400e5c3#fact-resource-facts-60)

Whim Creek Project · copper

#### Identity

- Project: Whim Creek Project
- Commodity: copper
- Region: australia\_wa
- Reported Region: Pilbara, Western Australia
- Ticker: ANX

#### Resource scope

- Estimate type: resource
- Effective date: 2026-10-13T00:00:00.000Z
- Reporting standards: jorc
- QP Signed: Yes
- Resource group id: resource:7a1080d86369e04b49bc
- Deposit or zone: Mons Cupri
- Mining method: combined
- Ownership percent: 80 %
- Resource basis: gross

#### Resource Data

- Category: indicated
- Tonnes: 3500000
- Grade: 0.75
- Grade Unit: %
- Cutoff Grade: 0.5
- Cutoff Unit: % CuEq

#### Prior Estimate

- Resource Date: 2026-08-25

#### Metal Equivalent

- Metal Eq. Grade: 1.27
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Historical: No

#### Dates

- Event date: 2026-10-25T00:00:00.000Z

Reasoning: The Indicated resource for copper at Mons Cupri is a positive, demonstrating good confidence in a significant portion of the deposit.

- Positive factor: Indicated category for copper, showing good geological confidence.

- Positive factor: Moderate copper grade contributing to the overall copper equivalent grade.

- Positive factor: Part of a significant resource update with overall tonnage and contained metal growth.

Evidence · table

> 0.75

Context: 3.5

#### Tags used in scoring

**No Contained Metal**

Polarity: negative

Definition: Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained\_metal was not reported

**No QP/CP Disclosure**

Polarity: negative

Definition: No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

**PEA-Supporting**

Polarity: neutral

Definition: Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

**DFS-Supporting**

Polarity: neutral

Definition: Resource estimate prepared to support a Definitive Feasibility Study — requires high M&amp;I confidence.

Why it applies: the release names the study this estimate supports

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.
