ANX: Quarterly Activities/Appendix 5B Cash Flow Report

Original announcement by asx on

Company
Anax Metals Limited
Ticker
ANX
Exchange
ASX
Region
Pilbara, Western Australia
Primary commodity
Unavailable
Secondary commodities
None reported
Document categories
Drill results, Resource update, Other
Extracted
2026-10-25 23:18:31 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Anax Metals reported exceptional high-grade drill intercepts from its Mons Cupri deposit, including 85.9m at 2.89% CuEq, as part of its September 2026 quarterly activities. The company also announced a 24% increase in the Mons Cupri Mineral Resource to 6.32Mt at 1.38% CuEq, with 78% in the Measured and Indicated categories. Further progress includes advancing Front-End Engineering Design (FEED) for the sulphide concentrator and positive column testwork results supporting a heap leach feasibility study at the Whim Creek Project.

Reasoning: The company reported exceptional high-grade drill results and a significant increase in the Mons Cupri Mineral Resource, alongside positive metallurgical testwork and project development progress, indicating strong advancement for the Whim Creek Project.

Positive factors

  • Exceptional high-grade drill intercepts at Mons Cupri, significantly exceeding project averages and peer benchmarks for VMS copper deposits.
  • Substantial increase in Mons Cupri Mineral Resource (24% tonnage, 20% contained CuEq metal) with a high Measured and Indicated component (78%).
  • Positive metallurgical column testwork results for copper and zinc extraction from lower-grade ores, supporting the heap leach strategy.
  • Advancement of Front-End Engineering Design (FEED) and commencement of a heap leach feasibility study, indicating progress towards project development.

Negative factors

  • Drill intercepts reported as downhole widths only, with true widths not determined, which may overstate actual thickness.
  • The global resource update includes historical estimates for some deposits, and the new Mons Cupri resource has not yet been incorporated into the Ore Reserve.
  • Metallurgical testwork is at the column test stage, not yet pilot scale, indicating further de-risking is required.

Facts used in scoring: 61

Atlas analysis — Anax Metals Limited: ANX: Quarterly Activities/Appendix 5B Cash Flow Report. 1.36 % over 85.9 m; measured 1500000 tonnes

Extracted facts

Stored fact records: 61. Some facts used in scoring do not have a stored record.

Drill Results (55)

26ANXDD001Whim Creek · copperGrade: 1.36Grade Unit: %Intercept: 85.9 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
copper
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
1.36
Grade Unit
%
Intercept
85.9 m
From
34.6 m
To
120.5 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:34.6-120.5
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
2.89
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This is a strong, wide intercept with good copper equivalent grade, indicating significant mineralization, but the lack of true width information introduces some uncertainty.

Positive factors

  • Significant intercept length of 85.9m at a strong copper equivalent grade of 2.89% CuEq, well above the VMS copper deposit average.
  • High-grade copper and gold components contribute to the overall value.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“1.36”

Context: 85.90

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · zincGrade: 2.18Grade Unit: %Intercept: 85.9 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
zinc
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
2.18
Grade Unit
%
Intercept
85.9 m
From
34.6 m
To
120.5 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:34.6-120.5
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
2.89
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The zinc grade is a positive contributor to the overall polymetallic intercept, but the lack of true width information introduces some uncertainty.

Positive factors

  • Good zinc grade over a significant intercept length, contributing to the polymetallic nature of the mineralization.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“2.18”

Context: 85.90

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · leadGrade: 0.79Grade Unit: %Intercept: 85.9 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
lead
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.79
Grade Unit
%
Intercept
85.9 m
From
34.6 m
To
120.5 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:34.6-120.5
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
2.89
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The lead grade adds to the overall value of the polymetallic intercept, but the lack of true width information introduces some uncertainty.

Positive factors

  • Lead grade contributes to the polymetallic nature of the mineralization over a significant intercept length.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.79”

Context: 85.90

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · silverGrade: 35.7Grade Unit: g/tIntercept: 85.9 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
silver
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
35.7
Grade Unit
g/t
Intercept
85.9 m
From
34.6 m
To
120.5 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:34.6-120.5
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
2.89
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of the polymetallic intercept, but the lack of true width information introduces some uncertainty.

Positive factors

  • Silver grade contributes to the polymetallic nature of the mineralization over a significant intercept length.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“35.7”

Context: 85.90

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · goldGrade: 1.05Grade Unit: g/tIntercept: 85.9 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
gold
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
1.05
Grade Unit
g/t
Intercept
85.9 m
From
34.6 m
To
120.5 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:34.6-120.5
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
2.89
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The gold grade adds to the overall value of the polymetallic intercept, but the lack of true width information introduces some uncertainty.

Positive factors

  • Gold grade contributes to the polymetallic nature of the mineralization over a significant intercept length.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“1.05”

Context: 85.90

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · copperGrade: 1.54Grade Unit: %Intercept: 4.7 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
copper
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
1.54
Grade Unit
%
Intercept
4.7 m
From
34.6 m
To
39.3 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:34.6-39.3
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
8.34
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This sub-interval represents bonanza grades, particularly for zinc and lead, making it an exceptional result within the broader intercept.

Positive factors

  • Exceptional high-grade copper equivalent of 8.34% CuEq over a moderate width, significantly contributing to the overall intercept value.
  • High zinc and lead grades further enhance the value of this sub-interval.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“1.54”

Context: 4.70

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The copper equivalent grade of 8.34% CuEq over 4.7m is exceptionally high for a VMS deposit.

Evidence · table

“8.34”

Context: 4.70

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · zincGrade: 19.99Grade Unit: %Intercept: 4.7 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
zinc
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
19.99
Grade Unit
%
Intercept
4.7 m
From
34.6 m
To
39.3 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:34.6-39.3
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
8.34
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This high-grade zinc intercept is a key driver of the exceptional copper equivalent grade in this sub-interval.

Positive factors

  • Exceptional high-grade zinc of 19.99% over 4.7m, significantly above the VMS zinc deposit average, contributing to the overall bonanza grade of the sub-interval.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“19.99”

Context: 4.70

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The zinc grade of 19.99% over 4.7m is exceptionally high for a VMS deposit.

Evidence · table

“19.99”

Context: 4.70

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · leadGrade: 9.07Grade Unit: %Intercept: 4.7 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
lead
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
9.07
Grade Unit
%
Intercept
4.7 m
From
34.6 m
To
39.3 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:34.6-39.3
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
8.34
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This high-grade lead intercept is a key driver of the exceptional copper equivalent grade in this sub-interval.

Positive factors

  • Exceptional high-grade lead of 9.07% over 4.7m, significantly above the VMS lead deposit average, contributing to the overall bonanza grade of the sub-interval.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“9.07”

Context: 4.70

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The lead grade of 9.07% over 4.7m is exceptionally high for a VMS deposit.

Evidence · table

“9.07”

Context: 4.70

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · silverGrade: 174.5Grade Unit: g/tIntercept: 4.7 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
silver
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
174.5
Grade Unit
g/t
Intercept
4.7 m
From
34.6 m
To
39.3 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:34.6-39.3
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
8.34
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds significant value to this high-grade sub-interval, enhancing the polymetallic nature of the mineralization.

Positive factors

  • Strong silver grade of 174.5 g/t over 4.7m, contributing to the overall bonanza grade of the sub-interval.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“174.5”

Context: 4.70

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · goldGrade: 0.54Grade Unit: g/tIntercept: 4.7 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
gold
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.54
Grade Unit
g/t
Intercept
4.7 m
From
34.6 m
To
39.3 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:34.6-39.3
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
8.34
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The gold grade adds to the overall value of this high-grade sub-interval, enhancing the polymetallic nature of the mineralization.

Positive factors

  • Gold grade contributes to the polymetallic nature of the mineralization within this high-grade sub-interval.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.54”

Context: 4.70

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · copperGrade: 4.74Grade Unit: %Intercept: 17.5 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
copper
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
4.74
Grade Unit
%
Intercept
17.5 m
From
39.3 m
To
56.8 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:39.3-56.8
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
8.37
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This sub-interval represents bonanza grades with very high copper and gold, making it an exceptional result within the broader intercept.

Positive factors

  • Exceptional high-grade copper equivalent of 8.37% CuEq over a significant width of 17.5m, indicating a very strong mineralized zone.
  • High copper and gold grades are key contributors to this bonanza intercept.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“4.74”

Context: 17.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The copper equivalent grade of 8.37% CuEq over 17.5m is exceptionally high for a VMS deposit.

Evidence · table

“8.37”

Context: 17.50

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · zincGrade: 0.29Grade Unit: %Intercept: 17.5 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
zinc
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.29
Grade Unit
%
Intercept
17.5 m
From
39.3 m
To
56.8 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:39.3-56.8
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
8.37
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: While part of a high-grade intercept, the zinc grade itself is weak and does not significantly contribute to the overall value.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Zinc grade is relatively low for a VMS deposit, not a primary contributor to the high CuEq.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.29”

Context: 17.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · leadGrade: 0.12Grade Unit: %Intercept: 17.5 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
lead
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.12
Grade Unit
%
Intercept
17.5 m
From
39.3 m
To
56.8 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:39.3-56.8
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
8.37
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: While part of a high-grade intercept, the lead grade itself is weak and does not significantly contribute to the overall value.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Lead grade is relatively low for a VMS deposit, not a primary contributor to the high CuEq.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.12”

Context: 17.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · silverGrade: 47.3Grade Unit: g/tIntercept: 17.5 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
silver
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
47.3
Grade Unit
g/t
Intercept
17.5 m
From
39.3 m
To
56.8 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:39.3-56.8
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
8.37
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of this high-grade sub-interval, enhancing the polymetallic nature of the mineralization.

Positive factors

  • Silver grade contributes to the polymetallic nature of the mineralization within this high-grade sub-interval.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“47.3”

Context: 17.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · goldGrade: 4.75Grade Unit: g/tIntercept: 17.5 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
gold
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
4.75
Grade Unit
g/t
Intercept
17.5 m
From
39.3 m
To
56.8 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:39.3-56.8
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
8.37
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This high-grade gold intercept is a key driver of the exceptional copper equivalent grade in this sub-interval.

Positive factors

  • Exceptional high-grade gold of 4.75 g/t over 17.5m, significantly contributing to the overall bonanza grade of the sub-interval.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“4.75”

Context: 17.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The gold grade of 4.75 g/t over 17.5m is exceptionally high for a VMS deposit.

Evidence · table

“4.75”

Context: 17.50

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · copperGrade: 0.15Grade Unit: %Intercept: 8.5 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
copper
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.15
Grade Unit
%
Intercept
8.5 m
From
112 m
To
120.5 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:112-120.5
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.6
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This sub-interval shows moderate copper equivalent grade, primarily driven by zinc and silver, but the copper grade itself is weak.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Copper grade is low, but the overall CuEq is moderate due to other metals.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.15”

Context: 8.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · zincGrade: 5.13Grade Unit: %Intercept: 8.5 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
zinc
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
5.13
Grade Unit
%
Intercept
8.5 m
From
112 m
To
120.5 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:112-120.5
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.6
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This sub-interval shows a moderate zinc grade, which is a key contributor to the overall copper equivalent value.

Positive factors

  • Moderate zinc grade over a reasonable width, contributing significantly to the copper equivalent grade.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“5.13”

Context: 8.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · leadGrade: 1.03Grade Unit: %Intercept: 8.5 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
lead
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
1.03
Grade Unit
%
Intercept
8.5 m
From
112 m
To
120.5 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:112-120.5
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.6
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The lead grade adds to the overall value of this sub-interval, enhancing the polymetallic nature of the mineralization.

Positive factors

  • Lead grade contributes to the polymetallic nature of the mineralization within this sub-interval.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“1.03”

Context: 8.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · silverGrade: 35.2Grade Unit: g/tIntercept: 8.5 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
silver
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
35.2
Grade Unit
g/t
Intercept
8.5 m
From
112 m
To
120.5 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:112-120.5
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.6
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of this sub-interval, enhancing the polymetallic nature of the mineralization.

Positive factors

  • Silver grade contributes to the polymetallic nature of the mineralization within this sub-interval.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“35.2”

Context: 8.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · goldGrade: 0.04Grade Unit: g/tIntercept: 8.5 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
gold
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.04
Grade Unit
g/t
Intercept
8.5 m
From
112 m
To
120.5 m
Intercept Depth
34.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:112-120.5
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.6
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The gold grade in this sub-interval is weak and has minimal impact on the overall copper equivalent value.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Gold grade is very low and does not significantly contribute to the overall CuEq grade.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.04”

Context: 8.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · copperGrade: 0.94Grade Unit: %Intercept: 18.55 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
copper
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.94
Grade Unit
%
Intercept
18.55 m
From
145.45 m
To
164 m
Intercept Depth
145.45 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:145.45-164
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.06
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This separate intercept shows moderate copper equivalent mineralization, extending the known zone, but lacks true width information.

Positive factors

  • Moderate copper equivalent grade over a good width, indicating continued mineralization at depth.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.94”

Context: 18.55

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · zincGrade: 0.07Grade Unit: %Intercept: 18.55 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
zinc
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.07
Grade Unit
%
Intercept
18.55 m
From
145.45 m
To
164 m
Intercept Depth
145.45 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:145.45-164
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.06
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The zinc grade in this intercept is weak and has minimal impact on the overall copper equivalent value.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Zinc grade is very low and does not significantly contribute to the overall CuEq grade.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.07”

Context: 18.55

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · leadGrade: 0.02Grade Unit: %Intercept: 18.55 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
lead
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.02
Grade Unit
%
Intercept
18.55 m
From
145.45 m
To
164 m
Intercept Depth
145.45 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:145.45-164
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.06
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The lead grade in this intercept is weak and has minimal impact on the overall copper equivalent value.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Lead grade is very low and does not significantly contribute to the overall CuEq grade.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.02”

Context: 18.55

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · silverGrade: 3.7Grade Unit: g/tIntercept: 18.55 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
silver
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
3.7
Grade Unit
g/t
Intercept
18.55 m
From
145.45 m
To
164 m
Intercept Depth
145.45 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:145.45-164
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.06
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The silver grade in this intercept is weak and has minimal impact on the overall copper equivalent value.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Silver grade is low and does not significantly contribute to the overall CuEq grade.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“3.7”

Context: 18.55

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD001Whim Creek · goldGrade: 0.09Grade Unit: g/tIntercept: 18.55 mView all details
Link to this fact

Identity

Hole ID
26ANXDD001
Project
Whim Creek
Commodity
gold
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.09
Grade Unit
g/t
Intercept
18.55 m
From
145.45 m
To
164 m
Intercept Depth
145.45 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD001:145.45-164
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.06
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The gold grade in this intercept is weak and has minimal impact on the overall copper equivalent value.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Gold grade is very low and does not significantly contribute to the overall CuEq grade.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.09”

Context: 18.55

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD002Whim Creek · copperGrade: 0.01Grade Unit: %Intercept: 13 mHistorical resultNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD002
Project
Whim Creek
Commodity
copper
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.01
Grade Unit
%
Intercept
13 m
From
169 m
To
182 m
Intercept Depth
169 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD002:169-182
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This intercept shows very weak copper mineralization, contributing minimally to the overall copper equivalent grade.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Very low copper grade, indicating poor mineralization for this commodity.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.01”

Context: 13.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD002Whim Creek · zincGrade: 2.3Grade Unit: %Intercept: 13 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD002
Project
Whim Creek
Commodity
zinc
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
2.3
Grade Unit
%
Intercept
13 m
From
169 m
To
182 m
Intercept Depth
169 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD002:169-182
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This intercept shows a moderate zinc grade, which is a key contributor to the overall copper equivalent value.

Positive factors

  • Moderate zinc grade over a reasonable width, contributing to the overall copper equivalent grade.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“2.30”

Context: 13.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD002Whim Creek · leadGrade: 0.75Grade Unit: %Intercept: 13 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD002
Project
Whim Creek
Commodity
lead
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.75
Grade Unit
%
Intercept
13 m
From
169 m
To
182 m
Intercept Depth
169 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD002:169-182
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The lead grade adds to the overall value of this intercept, enhancing the polymetallic nature of the mineralization.

Positive factors

  • Lead grade contributes to the polymetallic nature of the mineralization within this intercept.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.75”

Context: 13.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD002Whim Creek · silverGrade: 26.5Grade Unit: g/tIntercept: 13 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD002
Project
Whim Creek
Commodity
silver
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
26.5
Grade Unit
g/t
Intercept
13 m
From
169 m
To
182 m
Intercept Depth
169 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD002:169-182
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of this intercept, enhancing the polymetallic nature of the mineralization.

Positive factors

  • Silver grade contributes to the polymetallic nature of the mineralization within this intercept.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“26.5”

Context: 13.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD002Whim Creek · goldGrade: 0.04Grade Unit: g/tIntercept: 13 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD002
Project
Whim Creek
Commodity
gold
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.04
Grade Unit
g/t
Intercept
13 m
From
169 m
To
182 m
Intercept Depth
169 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD002:169-182
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This intercept shows very weak gold mineralization, contributing minimally to the overall copper equivalent grade.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Very low gold grade, indicating poor mineralization for this commodity.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.04”

Context: 13.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · copperGrade: 1.59Grade Unit: %Intercept: 62.54 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
copper
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
1.59
Grade Unit
%
Intercept
62.54 m
From
107.32 m
To
169.86 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:107.32-169.86
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
2.95
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This is a strong, wide intercept with good copper equivalent grade, indicating significant mineralization, but the lack of true width information introduces some uncertainty.

Positive factors

  • Strong copper equivalent grade of 2.95% CuEq over a significant width of 62.54m, indicating a substantial mineralized zone.
  • High gold grade contributes significantly to the overall value.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“1.59”

Context: 62.54

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · zincGrade: 1.13Grade Unit: %Intercept: 62.54 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
zinc
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
1.13
Grade Unit
%
Intercept
62.54 m
From
107.32 m
To
169.86 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:107.32-169.86
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
2.95
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The zinc grade is a positive contributor to the overall polymetallic intercept, but the lack of true width information introduces some uncertainty.

Positive factors

  • Moderate zinc grade over a significant intercept length, contributing to the polymetallic nature of the mineralization.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“1.13”

Context: 62.54

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · leadGrade: 0.41Grade Unit: %Intercept: 62.54 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
lead
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.41
Grade Unit
%
Intercept
62.54 m
From
107.32 m
To
169.86 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:107.32-169.86
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
2.95
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The lead grade adds to the overall value of the polymetallic intercept, but the lack of true width information introduces some uncertainty.

Positive factors

  • Lead grade contributes to the polymetallic nature of the mineralization over a significant intercept length.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.41”

Context: 62.54

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · silverGrade: 16.1Grade Unit: g/tIntercept: 62.54 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
silver
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
16.1
Grade Unit
g/t
Intercept
62.54 m
From
107.32 m
To
169.86 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:107.32-169.86
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
2.95
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of the polymetallic intercept, but the lack of true width information introduces some uncertainty.

Positive factors

  • Silver grade contributes to the polymetallic nature of the mineralization over a significant intercept length.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“16.1”

Context: 62.54

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · goldGrade: 1.46Grade Unit: g/tIntercept: 62.54 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
gold
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
1.46
Grade Unit
g/t
Intercept
62.54 m
From
107.32 m
To
169.86 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:107.32-169.86
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
2.95
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The gold grade is a positive contributor to the overall polymetallic intercept, but the lack of true width information introduces some uncertainty.

Positive factors

  • Moderate gold grade over a significant intercept length, contributing to the overall copper equivalent grade.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“1.46”

Context: 62.54

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · copperGrade: 2.22Grade Unit: %Intercept: 5.04 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
copper
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
2.22
Grade Unit
%
Intercept
5.04 m
From
107.32 m
To
112.36 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:107.32-112.36
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
5.46
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This sub-interval represents bonanza grades, particularly for zinc and lead, making it an exceptional result within the broader intercept.

Positive factors

  • Exceptional high-grade copper equivalent of 5.46% CuEq over a narrow width, indicating a very strong mineralized zone.
  • High zinc and lead grades are key contributors to this bonanza intercept.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“2.22”

Context: 5.04

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The copper equivalent grade of 5.46% CuEq over 5.04m is exceptionally high for a VMS deposit.

Evidence · table

“5.46”

Context: 5.04

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · zincGrade: 9.8Grade Unit: %Intercept: 5.04 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
zinc
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
9.8
Grade Unit
%
Intercept
5.04 m
From
107.32 m
To
112.36 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:107.32-112.36
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
5.46
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This high-grade zinc intercept is a key driver of the exceptional copper equivalent grade in this sub-interval.

Positive factors

  • Strong zinc grade of 9.80% over 5.04m, significantly contributing to the overall bonanza grade of the sub-interval.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“9.80”

Context: 5.04

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The zinc grade of 9.80% over 5.04m is strong for a VMS deposit.

Evidence · table

“9.80”

Context: 5.04

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · leadGrade: 3.54Grade Unit: %Intercept: 5.04 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
lead
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
3.54
Grade Unit
%
Intercept
5.04 m
From
107.32 m
To
112.36 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:107.32-112.36
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
5.46
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This high-grade lead intercept is a key driver of the exceptional copper equivalent grade in this sub-interval.

Positive factors

  • Strong lead grade of 3.54% over 5.04m, significantly contributing to the overall bonanza grade of the sub-interval.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“3.54”

Context: 5.04

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The lead grade of 3.54% over 5.04m is strong for a VMS deposit.

Evidence · table

“3.54”

Context: 5.04

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · silverGrade: 69.8Grade Unit: g/tIntercept: 5.04 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
silver
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
69.8
Grade Unit
g/t
Intercept
5.04 m
From
107.32 m
To
112.36 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:107.32-112.36
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
5.46
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of this high-grade sub-interval, enhancing the polymetallic nature of the mineralization.

Positive factors

  • Moderate silver grade over a narrow width, contributing to the overall bonanza grade of the sub-interval.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“69.8”

Context: 5.04

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · goldGrade: 0.49Grade Unit: g/tIntercept: 5.04 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
gold
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.49
Grade Unit
g/t
Intercept
5.04 m
From
107.32 m
To
112.36 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:107.32-112.36
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
5.46
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The gold grade adds to the overall value of this high-grade sub-interval, enhancing the polymetallic nature of the mineralization.

Positive factors

  • Gold grade contributes to the polymetallic nature of the mineralization within this high-grade sub-interval.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.49”

Context: 5.04

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · copperGrade: 2.62Grade Unit: %Intercept: 18.98 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
copper
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
2.62
Grade Unit
%
Intercept
18.98 m
From
112.36 m
To
131.34 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:112.36-131.34
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
6.01
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This sub-interval represents bonanza grades with very high copper and gold, making it an exceptional result within the broader intercept.

Positive factors

  • Exceptional high-grade copper equivalent of 6.01% CuEq over a significant width of 18.98m, indicating a very strong mineralized zone.
  • High copper and gold grades are key contributors to this bonanza intercept.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“2.62”

Context: 18.98

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The copper equivalent grade of 6.01% CuEq over 18.98m is exceptionally high for a VMS deposit.

Evidence · table

“6.01”

Context: 18.98

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · zincGrade: 0.99Grade Unit: %Intercept: 18.98 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
zinc
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.99
Grade Unit
%
Intercept
18.98 m
From
112.36 m
To
131.34 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:112.36-131.34
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
6.01
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: While part of a high-grade intercept, the zinc grade itself is weak and does not significantly contribute to the overall value.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Zinc grade is relatively low for a VMS deposit, not a primary contributor to the high CuEq.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.99”

Context: 18.98

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · leadGrade: 0.38Grade Unit: %Intercept: 18.98 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
lead
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.38
Grade Unit
%
Intercept
18.98 m
From
112.36 m
To
131.34 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:112.36-131.34
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
6.01
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: While part of a high-grade intercept, the lead grade itself is weak and does not significantly contribute to the overall value.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Lead grade is relatively low for a VMS deposit, not a primary contributor to the high CuEq.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.38”

Context: 18.98

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · silverGrade: 23.3Grade Unit: g/tIntercept: 18.98 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
silver
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
23.3
Grade Unit
g/t
Intercept
18.98 m
From
112.36 m
To
131.34 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:112.36-131.34
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
6.01
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The silver grade adds to the overall value of this high-grade sub-interval, enhancing the polymetallic nature of the mineralization.

Positive factors

  • Silver grade contributes to the polymetallic nature of the mineralization within this high-grade sub-interval.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“23.3”

Context: 18.98

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD003Whim Creek · goldGrade: 4.52Grade Unit: g/tIntercept: 18.98 mNeeds review: ungroundedView all details
Link to this fact

Identity

Hole ID
26ANXDD003
Project
Whim Creek
Commodity
gold
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
4.52
Grade Unit
g/t
Intercept
18.98 m
From
112.36 m
To
131.34 m
Intercept Depth
107.32 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD003:112.36-131.34
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
6.01
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
ungrounded
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This high-grade gold intercept is a key driver of the exceptional copper equivalent grade in this sub-interval.

Positive factors

  • Exceptional high-grade gold of 4.52 g/t over 18.98m, significantly contributing to the overall bonanza grade of the sub-interval.

Negative factors

  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“4.52”

Context: 18.98

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The gold grade of 4.52 g/t over 18.98m is exceptionally high for a VMS deposit.

Evidence · table

“4.52”

Context: 18.98

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD004Whim Creek · copperGrade: 0.01Grade Unit: %Intercept: 0.29 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
26ANXDD004
Project
Whim Creek
Commodity
copper
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.01
Grade Unit
%
Intercept
0.29 m
From
110.79 m
To
111.08 m
Intercept Depth
110.79 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD004:110.79-111.08
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
3.48
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This is a very narrow intercept with a high copper equivalent grade, primarily driven by zinc and lead, but its limited width reduces its overall materiality.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Very narrow intercept length, limiting its overall significance.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.01”

Context: 0.29

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD004Whim Creek · zincGrade: 6.34Grade Unit: %Intercept: 0.29 mView all details
Link to this fact

Identity

Hole ID
26ANXDD004
Project
Whim Creek
Commodity
zinc
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
6.34
Grade Unit
%
Intercept
0.29 m
From
110.79 m
To
111.08 m
Intercept Depth
110.79 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD004:110.79-111.08
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
3.48
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This very narrow intercept shows a moderate zinc grade, which is a key contributor to the overall copper equivalent value, but its limited width reduces its overall materiality.

Positive factors

  • Moderate zinc grade over a very narrow width, contributing significantly to the copper equivalent grade.

Negative factors

  • Very narrow intercept length, limiting its overall significance.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“6.34”

Context: 0.29

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD004Whim Creek · leadGrade: 11.15Grade Unit: %Intercept: 0.29 mView all details
Link to this fact

Identity

Hole ID
26ANXDD004
Project
Whim Creek
Commodity
lead
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
11.15
Grade Unit
%
Intercept
0.29 m
From
110.79 m
To
111.08 m
Intercept Depth
110.79 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD004:110.79-111.08
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
3.48
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This very narrow intercept shows an exceptional lead grade, which is a key driver of the overall copper equivalent value, but its limited width reduces its overall materiality.

Positive factors

  • Exceptional high-grade lead of 11.15% over a very narrow width, significantly contributing to the copper equivalent grade.

Negative factors

  • Very narrow intercept length, limiting its overall significance.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“11.15”

Context: 0.29

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The lead grade of 11.15% over 0.29m is exceptionally high for a VMS deposit.

Evidence · table

“11.15”

Context: 0.29

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD004Whim Creek · silverGrade: 112Grade Unit: g/tIntercept: 0.29 mView all details
Link to this fact

Identity

Hole ID
26ANXDD004
Project
Whim Creek
Commodity
silver
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
112
Grade Unit
g/t
Intercept
0.29 m
From
110.79 m
To
111.08 m
Intercept Depth
110.79 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD004:110.79-111.08
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
3.48
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This very narrow intercept shows a strong silver grade, which is a key contributor to the overall copper equivalent value, but its limited width reduces its overall materiality.

Positive factors

  • Strong silver grade of 112.0 g/t over a very narrow width, contributing significantly to the copper equivalent grade.

Negative factors

  • Very narrow intercept length, limiting its overall significance.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“112.0”

Context: 0.29

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD004Whim Creek · goldGrade: 0.05Grade Unit: g/tIntercept: 0.29 mView all details
Link to this fact

Identity

Hole ID
26ANXDD004
Project
Whim Creek
Commodity
gold
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.05
Grade Unit
g/t
Intercept
0.29 m
From
110.79 m
To
111.08 m
Intercept Depth
110.79 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD004:110.79-111.08
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
3.48
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This very narrow intercept shows very weak gold mineralization, contributing minimally to the overall copper equivalent grade.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Very low gold grade, indicating poor mineralization for this commodity.
  • Very narrow intercept length, limiting its overall significance.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.05”

Context: 0.29

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD004Whim Creek · copperGrade: 0.81Grade Unit: %Intercept: 1.59 mView all details
Link to this fact

Identity

Hole ID
26ANXDD004
Project
Whim Creek
Commodity
copper
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.81
Grade Unit
%
Intercept
1.59 m
From
326.25 m
To
327.84 m
Intercept Depth
326.25 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD004:326.25-327.84
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.23
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This narrow intercept shows moderate copper equivalent mineralization, extending the known zone, but lacks true width information and is of limited width.

Positive factors

  • Moderate copper equivalent grade over a narrow width, indicating continued mineralization at depth.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Narrow intercept length, limiting its overall significance.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.81”

Context: 1.59

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD004Whim Creek · zincGrade: 1.28Grade Unit: %Intercept: 1.59 mView all details
Link to this fact

Identity

Hole ID
26ANXDD004
Project
Whim Creek
Commodity
zinc
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
1.28
Grade Unit
%
Intercept
1.59 m
From
326.25 m
To
327.84 m
Intercept Depth
326.25 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD004:326.25-327.84
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.23
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This narrow intercept shows a moderate zinc grade, which is a key contributor to the overall copper equivalent value, but its limited width reduces its overall materiality.

Positive factors

  • Zinc grade contributes to the polymetallic nature of the mineralization within this intercept.
  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Narrow intercept length, limiting its overall significance.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“1.28”

Context: 1.59

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD004Whim Creek · leadGrade: 0.17Grade Unit: %Intercept: 1.59 mView all details
Link to this fact

Identity

Hole ID
26ANXDD004
Project
Whim Creek
Commodity
lead
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.17
Grade Unit
%
Intercept
1.59 m
From
326.25 m
To
327.84 m
Intercept Depth
326.25 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD004:326.25-327.84
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.23
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This narrow intercept shows a weak lead grade, which has minimal impact on the overall copper equivalent value.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Lead grade is low and does not significantly contribute to the overall CuEq grade.
  • Narrow intercept length, limiting its overall significance.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.17”

Context: 1.59

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD004Whim Creek · silverGrade: 12.6Grade Unit: g/tIntercept: 1.59 mView all details
Link to this fact

Identity

Hole ID
26ANXDD004
Project
Whim Creek
Commodity
silver
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
12.6
Grade Unit
g/t
Intercept
1.59 m
From
326.25 m
To
327.84 m
Intercept Depth
326.25 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD004:326.25-327.84
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.23
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This narrow intercept shows a weak silver grade, which has minimal impact on the overall copper equivalent value.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Silver grade is low and does not significantly contribute to the overall CuEq grade.
  • Narrow intercept length, limiting its overall significance.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“12.6”

Context: 1.59

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”
26ANXDD004Whim Creek · goldGrade: 0.04Grade Unit: g/tIntercept: 1.59 mView all details
Link to this fact

Identity

Hole ID
26ANXDD004
Project
Whim Creek
Commodity
gold
Region
australia_wa
Reported Region
australia_wa
Ticker
ANX

Geometry

Grade
0.04
Grade Unit
g/t
Intercept
1.59 m
From
326.25 m
To
327.84 m
Intercept Depth
326.25 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
26ANXDD004:326.25-327.84
Mining Method
open_pit

Location

Location
Mons Cupri
Loc. Source
document

QA/QC

QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
1.23
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.5
Cutoff Unit
% CuEq
Dilution Disclosed
Yes
Max Dilution
3 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: This narrow intercept shows very weak gold mineralization, contributing minimally to the overall copper equivalent grade.

Positive factors

  • Part of a new drilling campaign targeting extensions and infill.

Negative factors

  • Very low gold grade, indicating poor mineralization for this commodity.
  • Narrow intercept length, limiting its overall significance.
  • True width not determined, meaning the reported length may be an overestimation of actual thickness.

Evidence · table

“0.04”

Context: 1.59

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Apparent Width OnlyRejected · negative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Reason: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Widths are downhole; true widths have not been determined.”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The release discloses the CuEq formula and assumptions, indicating QA/QC procedures are in place.

Evidence · text

“CuEq formula and all assumptions are set out in the Copper Equivalent Calculation section following Table 3.”

Cut-off DisclosedRejected · positive · Story-specific tag

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Reason: The reporting basis includes a 0.50% CuEq lower cut-off.

Evidence · text

“Reporting basis: 0.50% CuEq lower cut-off and maximum 3m internal dilution.”

Resource Estimates (6)

measuredWhim Creek Project · copperTonnes: 1500000Grade: 1.22Grade Unit: %View all details
Link to this fact

Identity

Project
Whim Creek Project
Commodity
copper
Region
australia_wa
Reported Region
Pilbara, Western Australia
Ticker
ANX

Resource scope

Estimate type
resource
Effective date
2026-10-13T00:00:00.000Z
Reporting standards
jorc
QP Signed
Yes
Resource group id
resource:6b833237bf55f08382ce
Deposit or zone
Mons Cupri
Mining method
combined
Ownership percent
80 %
Resource basis
gross

Resource Data

Category
measured
Tonnes
1500000
Grade
1.22
Grade Unit
%
Cutoff Grade
0.5
Cutoff Unit
% CuEq

Prior Estimate

Resource Date
2026-08-25

Metal Equivalent

Metal Eq. Grade
2.03
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The Measured resource for copper at Mons Cupri is a strong positive, demonstrating high confidence in a portion of the deposit.

Positive factors

  • High confidence Measured category for copper, indicating robust geological understanding.
  • Good copper grade contributing to a strong copper equivalent grade.
  • Part of a significant resource update with overall tonnage and contained metal growth.

Evidence · table

“1.22”

Context: 1.5

Tags used in scoring

No Contained Metalnegative

Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained_metal was not reported

No QP/CP Disclosurenegative

No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

PEA-Supportingneutral

Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

DFS-Supportingneutral

Resource estimate prepared to support a Definitive Feasibility Study — requires high M&I confidence.

Why it applies: the release names the study this estimate supports

measuredWhim Creek Project · zincTonnes: 1500000Grade: 1.41Grade Unit: %View all details
Link to this fact

Identity

Project
Whim Creek Project
Commodity
zinc
Region
australia_wa
Reported Region
Pilbara, Western Australia
Ticker
ANX

Resource scope

Estimate type
resource
Effective date
2026-10-13T00:00:00.000Z
Reporting standards
jorc
QP Signed
Yes
Resource group id
resource:6b833237bf55f08382ce
Deposit or zone
Mons Cupri
Mining method
combined
Ownership percent
80 %
Resource basis
gross

Resource Data

Category
measured
Tonnes
1500000
Grade
1.41
Grade Unit
%
Cutoff Grade
0.5
Cutoff Unit
% CuEq

Prior Estimate

Resource Date
2026-08-25

Metal Equivalent

Metal Eq. Grade
2.03
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The Measured resource for zinc at Mons Cupri is a positive, demonstrating high confidence in a portion of the deposit.

Positive factors

  • High confidence Measured category for zinc, indicating robust geological understanding.
  • Good zinc grade contributing to the overall copper equivalent grade.
  • Part of a significant resource update with overall tonnage and contained metal growth.

Evidence · table

“1.41”

Context: 1.5

Tags used in scoring

No Contained Metalnegative

Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained_metal was not reported

No QP/CP Disclosurenegative

No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

PEA-Supportingneutral

Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

DFS-Supportingneutral

Resource estimate prepared to support a Definitive Feasibility Study — requires high M&I confidence.

Why it applies: the release names the study this estimate supports

measuredWhim Creek Project · leadTonnes: 1500000Grade: 0.57Grade Unit: %View all details
Link to this fact

Identity

Project
Whim Creek Project
Commodity
lead
Region
australia_wa
Reported Region
Pilbara, Western Australia
Ticker
ANX

Resource scope

Estimate type
resource
Effective date
2026-10-13T00:00:00.000Z
Reporting standards
jorc
QP Signed
Yes
Resource group id
resource:6b833237bf55f08382ce
Deposit or zone
Mons Cupri
Mining method
combined
Ownership percent
80 %
Resource basis
gross

Resource Data

Category
measured
Tonnes
1500000
Grade
0.57
Grade Unit
%
Cutoff Grade
0.5
Cutoff Unit
% CuEq

Prior Estimate

Resource Date
2026-08-25

Metal Equivalent

Metal Eq. Grade
2.03
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The Measured resource for lead at Mons Cupri is a positive, demonstrating high confidence in a portion of the deposit.

Positive factors

  • High confidence Measured category for lead, indicating robust geological understanding.
  • Good lead grade contributing to the overall copper equivalent grade.
  • Part of a significant resource update with overall tonnage and contained metal growth.

Evidence · table

“0.57”

Context: 1.5

Tags used in scoring

No Contained Metalnegative

Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained_metal was not reported

No QP/CP Disclosurenegative

No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

PEA-Supportingneutral

Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

DFS-Supportingneutral

Resource estimate prepared to support a Definitive Feasibility Study — requires high M&I confidence.

Why it applies: the release names the study this estimate supports

measuredWhim Creek Project · silverTonnes: 1500000Grade: 31Grade Unit: ppmView all details
Link to this fact

Identity

Project
Whim Creek Project
Commodity
silver
Region
australia_wa
Reported Region
Pilbara, Western Australia
Ticker
ANX

Resource scope

Estimate type
resource
Effective date
2026-10-13T00:00:00.000Z
Reporting standards
jorc
QP Signed
Yes
Resource group id
resource:6b833237bf55f08382ce
Deposit or zone
Mons Cupri
Mining method
combined
Ownership percent
80 %
Resource basis
gross

Resource Data

Category
measured
Tonnes
1500000
Grade
31
Grade Unit
ppm
Cutoff Grade
0.5
Cutoff Unit
% CuEq

Prior Estimate

Resource Date
2026-08-25

Metal Equivalent

Metal Eq. Grade
2.03
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The Measured resource for silver at Mons Cupri is a positive, demonstrating high confidence in a portion of the deposit.

Positive factors

  • High confidence Measured category for silver, indicating robust geological understanding.
  • Good silver grade contributing to the overall copper equivalent grade.
  • Part of a significant resource update with overall tonnage and contained metal growth.

Evidence · table

“31”

Context: 1.5

Tags used in scoring

No Contained Metalnegative

Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained_metal was not reported

No QP/CP Disclosurenegative

No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

PEA-Supportingneutral

Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

DFS-Supportingneutral

Resource estimate prepared to support a Definitive Feasibility Study — requires high M&I confidence.

Why it applies: the release names the study this estimate supports

measuredWhim Creek Project · goldTonnes: 1500000Grade: 0.28Grade Unit: ppmView all details
Link to this fact

Identity

Project
Whim Creek Project
Commodity
gold
Region
australia_wa
Reported Region
Pilbara, Western Australia
Ticker
ANX

Resource scope

Estimate type
resource
Effective date
2026-10-13T00:00:00.000Z
Reporting standards
jorc
QP Signed
Yes
Resource group id
resource:6b833237bf55f08382ce
Deposit or zone
Mons Cupri
Mining method
combined
Ownership percent
80 %
Resource basis
gross

Resource Data

Category
measured
Tonnes
1500000
Grade
0.28
Grade Unit
ppm
Cutoff Grade
0.5
Cutoff Unit
% CuEq

Prior Estimate

Resource Date
2026-08-25

Metal Equivalent

Metal Eq. Grade
2.03
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The Measured resource for gold at Mons Cupri is a positive, demonstrating high confidence in a portion of the deposit.

Positive factors

  • High confidence Measured category for gold, indicating robust geological understanding.
  • Good gold grade contributing to the overall copper equivalent grade.
  • Part of a significant resource update with overall tonnage and contained metal growth.

Evidence · table

“0.28”

Context: 1.5

Tags used in scoring

No Contained Metalnegative

Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained_metal was not reported

No QP/CP Disclosurenegative

No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

PEA-Supportingneutral

Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

DFS-Supportingneutral

Resource estimate prepared to support a Definitive Feasibility Study — requires high M&I confidence.

Why it applies: the release names the study this estimate supports

indicatedWhim Creek Project · copperTonnes: 3500000Grade: 0.75Grade Unit: %View all details
Link to this fact

Identity

Project
Whim Creek Project
Commodity
copper
Region
australia_wa
Reported Region
Pilbara, Western Australia
Ticker
ANX

Resource scope

Estimate type
resource
Effective date
2026-10-13T00:00:00.000Z
Reporting standards
jorc
QP Signed
Yes
Resource group id
resource:7a1080d86369e04b49bc
Deposit or zone
Mons Cupri
Mining method
combined
Ownership percent
80 %
Resource basis
gross

Resource Data

Category
indicated
Tonnes
3500000
Grade
0.75
Grade Unit
%
Cutoff Grade
0.5
Cutoff Unit
% CuEq

Prior Estimate

Resource Date
2026-08-25

Metal Equivalent

Metal Eq. Grade
1.27
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Historical
No

Dates

Event date
2026-10-25T00:00:00.000Z

Reasoning: The Indicated resource for copper at Mons Cupri is a positive, demonstrating good confidence in a significant portion of the deposit.

Positive factors

  • Indicated category for copper, showing good geological confidence.
  • Moderate copper grade contributing to the overall copper equivalent grade.
  • Part of a significant resource update with overall tonnage and contained metal growth.

Evidence · table

“0.75”

Context: 3.5

Tags used in scoring

No Contained Metalnegative

Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained_metal was not reported

No QP/CP Disclosurenegative

No Qualified Person or Competent Person named — lower credibility for the estimate. A QP/CP should be a member of a recognized professional association with relevant experience.

Why it applies: no Qualified or Competent Person is named anywhere in the release

PEA-Supportingneutral

Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

DFS-Supportingneutral

Resource estimate prepared to support a Definitive Feasibility Study — requires high M&I confidence.

Why it applies: the release names the study this estimate supports

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.