American Tungsten Advances of the IMA Mine Project: New Vein Discovery, Strong In-fill Drill results and Ongoing PEA Development

Original announcement by orestocks on

Company
American Tungsten Corp.
Ticker
TUNG.V
Exchange
Unavailable
Region
Idaho
Primary commodity
Tungsten
Secondary commodities
Silver, Molybdenum, Copper, Lead, Zinc
Document categories
Drill results
Extracted
2026-10-29 11:43:09 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

American Tungsten Corp. reported positive drill results from its IMA Mine Project in Idaho, including the discovery of the new 360 portal vein with significant tungsten and silver intercepts. Infill and step-out drilling also yielded strong tungsten grades from the upper-Ima vein system, contributing to resource conversion and expansion efforts. The company is concurrently progressing engineering and metallurgical work for a Preliminary Economic Assessment, anticipated before year-end.

Reasoning: American Tungsten announced positive drill results from a new vein discovery and strong infill drilling at its IMA Mine Project, which supports resource expansion and conversion while advancing towards a Preliminary Economic Assessment.

Positive factors

  • New vein discovery (360 portal vein) with significant tungsten and silver intercepts
  • Strong infill drilling results supporting resource conversion and expansion
  • High-grade tungsten intercepts (up to 2.415% WO3)
  • True width estimates provided for reported intervals
  • QA/QC procedures disclosed and Qualified Person sign-off

Negative factors

  • One drill hole (AT26-51) was lost short of target depth with no significant intercepts

Facts used in scoring: 44

Atlas analysis — American Tungsten Corp.: American Tungsten Advances of the IMA Mine Project: New Vein Discovery, Strong In-fill Drill results and Ongoing PEA Development. 0.804 % over 5.60832 m; 0.536 % over 5.76072 m; 0.894 % over 3.3528 m

Extracted facts

Stored fact records: 44. Some facts used in scoring do not have a stored record.

Drill Results (44)

AT26-37IMA Mine · tungstenGrade: 2.415Grade Unit: %Intercept: 0.3048 mView all details
Link to this fact

Identity

Hole ID
AT26-37
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
2.415
Grade Unit
%
Intercept
0.3048 m
True Width
0.19 m
From
30.48 m
To
30.7848 m
Intercept Depth
30.48 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-37:30.48-30.7848
Mining Method
underground

Location

Location
Zero Level
Azimuth
350 °
Dip
30 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept shows an exceptional tungsten grade, contributing positively to the resource confidence in the Zero Level.

Positive factors

  • Exceptional tungsten grade (2.415% WO3)
  • True width estimated at 0.19m
  • Supports resource conversion in a known area

Evidence · table

“2.415”

Context: 1

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: The drilling on the Zero Level is part of the ongoing infill program to expand and delineate the vein system.

Evidence · text

“underground infill and step out drilling on the D level continues to expand and better delineate the upper-Ima vein system.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The grade of 2.415% WO3 is exceptionally high for tungsten mineralization.

Evidence · table

“2.415”

Context: 1

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 60-65% for AT26-37, providing better context for the intercept.

Evidence · text

“True width is estimated at 60-65% for AT26-37, 49 and 53.”
AT26-37IMA Mine · tungstenGrade: 0.371Grade Unit: %Intercept: 1.00584 mView all details
Link to this fact

Identity

Hole ID
AT26-37
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.371
Grade Unit
%
Intercept
1.00584 m
True Width
0.63 m
From
40.8432 m
To
41.84904 m
Intercept Depth
40.8432 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-37:40.8432-41.84904
Mining Method
underground

Location

Location
Zero Level
Azimuth
350 °
Dip
30 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept provides additional data for resource conversion in the Zero Level with a moderate tungsten grade.

Positive factors

  • Moderate tungsten grade (0.371% WO3)
  • True width estimated at 0.63m
  • Supports resource conversion

Evidence · table

“0.371”

Context: 3.3

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: The drilling on the Zero Level is part of the ongoing infill program to expand and delineate the vein system.

Evidence · text

“underground infill and step out drilling on the D level continues to expand and better delineate the upper-Ima vein system.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 60-65% for AT26-37, providing better context for the intercept.

Evidence · text

“True width is estimated at 60-65% for AT26-37, 49 and 53.”
AT26-46IMA Mine · tungstenGrade: 0.213Grade Unit: %Intercept: 1.3716 mView all details
Link to this fact

Identity

Hole ID
AT26-46
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.213
Grade Unit
%
Intercept
1.3716 m
True Width
1.13 m
From
8.8392 m
To
10.2108 m
Intercept Depth
8.8392 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-46:8.8392-10.2108
Mining Method
underground

Location

Location
D Level
Azimuth
64.7 °
Dip
-63.1 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept provides low-moderate grade tungsten mineralization in the footwall of the D Level vein system.

Positive factors

  • Low-moderate tungsten grade (0.213% WO3)
  • True width estimated at 1.13m
  • Contributes to understanding of D Level footwall

Evidence · table

“0.213”

Context: 4.5

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-46 was drilled to step out on previously reported intercepts, part of the infill program.

Evidence · text

“Hole AT26-46 was drilled down into the footwall of the D level vein system to step out on previously reported intercepts in AT26-20”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 75-90% for AT26-46, providing better context for the intercept.

Evidence · text

“True width is estimated at 75-90% for AT26-58S and 46.”
AT26-46IMA Mine · tungstenGrade: 0.235Grade Unit: %Intercept: 1.524 mView all details
Link to this fact

Identity

Hole ID
AT26-46
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.235
Grade Unit
%
Intercept
1.524 m
True Width
1.26 m
From
21.0312 m
To
22.5552 m
Intercept Depth
21.0312 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-46:21.0312-22.5552
Mining Method
underground

Location

Location
D Level
Azimuth
64.7 °
Dip
-63.1 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept provides low-moderate grade tungsten mineralization in the footwall of the D Level vein system.

Positive factors

  • Low-moderate tungsten grade (0.235% WO3)
  • True width estimated at 1.26m
  • Contributes to understanding of D Level footwall

Evidence · table

“0.235”

Context: 5

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-46 was drilled to step out on previously reported intercepts, part of the infill program.

Evidence · text

“Hole AT26-46 was drilled down into the footwall of the D level vein system to step out on previously reported intercepts in AT26-20”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 75-90% for AT26-46, providing better context for the intercept.

Evidence · text

“True width is estimated at 75-90% for AT26-58S and 46.”
AT26-46IMA Mine · tungstenGrade: 0.224Grade Unit: %Intercept: 1.524 mView all details
Link to this fact

Identity

Hole ID
AT26-46
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.224
Grade Unit
%
Intercept
1.524 m
True Width
1.26 m
From
39.3192 m
To
40.8432 m
Intercept Depth
39.3192 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-46:39.3192-40.8432
Mining Method
underground

Location

Location
D Level
Azimuth
64.7 °
Dip
-63.1 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept provides low-moderate grade tungsten mineralization in the footwall of the D Level vein system.

Positive factors

  • Low-moderate tungsten grade (0.224% WO3)
  • True width estimated at 1.26m
  • Contributes to understanding of D Level footwall

Evidence · table

“0.224”

Context: 5

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-46 was drilled to step out on previously reported intercepts, part of the infill program.

Evidence · text

“Hole AT26-46 was drilled down into the footwall of the D level vein system to step out on previously reported intercepts in AT26-20”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 75-90% for AT26-46, providing better context for the intercept.

Evidence · text

“True width is estimated at 75-90% for AT26-58S and 46.”
AT26-46IMA Mine · tungstenGrade: 0.159Grade Unit: %Intercept: 1.524 mView all details
Link to this fact

Identity

Hole ID
AT26-46
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.159
Grade Unit
%
Intercept
1.524 m
True Width
1.26 m
From
49.9872 m
To
51.5112 m
Intercept Depth
49.9872 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-46:49.9872-51.5112
Mining Method
underground

Location

Location
D Level
Azimuth
64.7 °
Dip
-63.1 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept provides low-grade tungsten mineralization in the footwall of the D Level vein system.

Positive factors

  • Low tungsten grade (0.159% WO3)
  • True width estimated at 1.26m
  • Contributes to understanding of D Level footwall

Evidence · table

“0.159”

Context: 5

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-46 was drilled to step out on previously reported intercepts, part of the infill program.

Evidence · text

“Hole AT26-46 was drilled down into the footwall of the D level vein system to step out on previously reported intercepts in AT26-20”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 75-90% for AT26-46, providing better context for the intercept.

Evidence · text

“True width is estimated at 75-90% for AT26-58S and 46.”
AT26-47SIMA Mine · tungstenGrade: 0.249Grade Unit: %Intercept: 4.572 mView all details
Link to this fact

Identity

Hole ID
AT26-47S
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.249
Grade Unit
%
Intercept
4.572 m
True Width
3.09 m
From
56.0832 m
To
60.6552 m
Intercept Depth
56.0832 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-47S:56.0832-60.6552
Mining Method
underground

Location

Location
360 Portal
Azimuth
300 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept confirms tungsten mineralization in the newly discovered 360 portal vein, adding to the project's exploration potential.

Positive factors

  • Moderate tungsten grade (0.249% WO3)
  • True width estimated at 3.09m
  • Part of new vein discovery (360 portal vein)

Evidence · table

“0.249”

Context: 15

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 65-70% for AT26-47S, providing better context for the intercept.

Evidence · text

“True width is estimated at 65-70% for AT26-47S, 52S and 55S.”

Step-Out ExtensionRejected · positive

Mineralization extended beyond the previously known limit.

Reason: This hole is part of the initial surface exploration holes that intercepted the newly identified 360 portal vein.

Evidence · text

“Drilling results from initial surface exploration holes completed in the base of the canyon successfully intercepted a newly identified vein – the 360 portal vein.”
AT26-49IMA Mine · tungstenGrade: 1.322Grade Unit: %Intercept: 1.61544 mView all details
Link to this fact

Identity

Hole ID
AT26-49
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
1.322
Grade Unit
%
Intercept
1.61544 m
True Width
1.01 m
From
5.39496 m
To
7.0104 m
Intercept Depth
5.39496 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-49:5.39496-7.0104
Mining Method
underground

Location

Location
D Level
Azimuth
2.6 °
Dip
59 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept shows a strong tungsten grade, contributing to the expansion and delineation of the upper-Ima vein system on the D Level.

Positive factors

  • Strong tungsten grade (1.322% WO3)
  • True width estimated at 1.01m
  • Expands and delineates the upper-Ima vein system

Evidence · table

“1.322”

Context: 5.3

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-49 was designed to expand and step out from previous drilling, part of the infill program.

Evidence · text

“Drillholes AT26-49 and AT26-53 were upwardly inclined holes drilled to the north and west respectively from underground drill-stations DS3 and DS1 and were designed to expand and step out from previous drilling.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The grade of 1.322% WO3 is very high for tungsten mineralization.

Evidence · table

“1.322”

Context: 5.3

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 60-65% for AT26-49, providing better context for the intercept.

Evidence · text

“True width is estimated at 60-65% for AT26-37, 49 and 53.”
AT26-49IMA Mine · tungstenGrade: 0.804Grade Unit: %Intercept: 5.60832 mView all details
Link to this fact

Identity

Hole ID
AT26-49
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.804
Grade Unit
%
Intercept
5.60832 m
True Width
3.51 m
From
32.40024 m
To
38.00856 m
Intercept Depth
32.40024 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-49:32.40024-38.00856
Mining Method
underground

Location

Location
D Level
Azimuth
2.6 °
Dip
59 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept shows a strong tungsten grade over a good width, contributing to the expansion and delineation of the upper-Ima vein system on the D Level.

Positive factors

  • Strong tungsten grade (0.804% WO3) over a significant width
  • True width estimated at 3.51m
  • Expands and delineates the upper-Ima vein system

Evidence · table

“0.804”

Context: 18.4

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-49 was designed to expand and step out from previous drilling, part of the infill program.

Evidence · text

“Drillholes AT26-49 and AT26-53 were upwardly inclined holes drilled to the north and west respectively from underground drill-stations DS3 and DS1 and were designed to expand and step out from previous drilling.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 60-65% for AT26-49, providing better context for the intercept.

Evidence · text

“True width is estimated at 60-65% for AT26-37, 49 and 53.”
AT26-49IMA Mine · tungstenGrade: 0.135Grade Unit: %Intercept: 1.524 mView all details
Link to this fact

Identity

Hole ID
AT26-49
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.135
Grade Unit
%
Intercept
1.524 m
True Width
0.95 m
From
52.7304 m
To
54.2544 m
Intercept Depth
52.7304 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-49:52.7304-54.2544
Mining Method
underground

Location

Location
D Level
Azimuth
2.6 °
Dip
59 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept provides low-grade tungsten mineralization, contributing to the overall understanding of the vein system.

Positive factors

  • Low tungsten grade (0.135% WO3)
  • True width estimated at 0.95m
  • Contributes to understanding of vein system

Evidence · table

“0.135”

Context: 5

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-49 was designed to expand and step out from previous drilling, part of the infill program.

Evidence · text

“Drillholes AT26-49 and AT26-53 were upwardly inclined holes drilled to the north and west respectively from underground drill-stations DS3 and DS1 and were designed to expand and step out from previous drilling.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 60-65% for AT26-49, providing better context for the intercept.

Evidence · text

“True width is estimated at 60-65% for AT26-37, 49 and 53.”
AT26-49IMA Mine · tungstenGrade: 0.894Grade Unit: %Intercept: 3.3528 mView all details
Link to this fact

Identity

Hole ID
AT26-49
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.894
Grade Unit
%
Intercept
3.3528 m
True Width
2.09 m
From
68.58 m
To
71.9328 m
Intercept Depth
68.58 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-49:68.58-71.9328
Mining Method
underground

Location

Location
D Level
Azimuth
2.6 °
Dip
59 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept shows a strong tungsten grade, contributing to the expansion and delineation of the upper-Ima vein system on the D Level.

Positive factors

  • Strong tungsten grade (0.894% WO3)
  • True width estimated at 2.09m
  • Expands and delineates the upper-Ima vein system

Evidence · table

“0.894”

Context: 11

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-49 was designed to expand and step out from previous drilling, part of the infill program.

Evidence · text

“Drillholes AT26-49 and AT26-53 were upwardly inclined holes drilled to the north and west respectively from underground drill-stations DS3 and DS1 and were designed to expand and step out from previous drilling.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 60-65% for AT26-49, providing better context for the intercept.

Evidence · text

“True width is estimated at 60-65% for AT26-37, 49 and 53.”
AT26-49IMA Mine · tungstenGrade: 0.627Grade Unit: %Intercept: 1.43256 mView all details
Link to this fact

Identity

Hole ID
AT26-49
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.627
Grade Unit
%
Intercept
1.43256 m
True Width
0.9 m
From
90.37224 m
To
91.8048 m
Intercept Depth
90.37224 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-49:90.37224-91.8048
Mining Method
underground

Location

Location
D Level
Azimuth
2.6 °
Dip
59 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept shows a strong tungsten grade, contributing to the expansion and delineation of the upper-Ima vein system on the D Level.

Positive factors

  • Strong tungsten grade (0.627% WO3)
  • True width estimated at 0.90m
  • Expands and delineates the upper-Ima vein system

Evidence · table

“0.627”

Context: 4.7

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-49 was designed to expand and step out from previous drilling, part of the infill program.

Evidence · text

“Drillholes AT26-49 and AT26-53 were upwardly inclined holes drilled to the north and west respectively from underground drill-stations DS3 and DS1 and were designed to expand and step out from previous drilling.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 60-65% for AT26-49, providing better context for the intercept.

Evidence · text

“True width is estimated at 60-65% for AT26-37, 49 and 53.”
AT26-49IMA Mine · tungstenGrade: 0.24Grade Unit: %Intercept: 2.1336 mView all details
Link to this fact

Identity

Hole ID
AT26-49
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.24
Grade Unit
%
Intercept
2.1336 m
True Width
1.33 m
From
108.5088 m
To
110.6424 m
Intercept Depth
108.5088 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-49:108.5088-110.6424
Mining Method
underground

Location

Location
D Level
Azimuth
2.6 °
Dip
59 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept provides moderate-grade tungsten mineralization, contributing to the overall understanding of the vein system.

Positive factors

  • Moderate tungsten grade (0.240% WO3)
  • True width estimated at 1.33m
  • Contributes to understanding of vein system

Evidence · table

“0.240”

Context: 7

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-49 was designed to expand and step out from previous drilling, part of the infill program.

Evidence · text

“Drillholes AT26-49 and AT26-53 were upwardly inclined holes drilled to the north and west respectively from underground drill-stations DS3 and DS1 and were designed to expand and step out from previous drilling.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 60-65% for AT26-49, providing better context for the intercept.

Evidence · text

“True width is estimated at 60-65% for AT26-37, 49 and 53.”
AT26-52SIMA Mine · tungstenGrade: 0.475Grade Unit: %Intercept: 1.524 mView all details
Link to this fact

Identity

Hole ID
AT26-52S
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.475
Grade Unit
%
Intercept
1.524 m
True Width
1.03 m
From
42.3672 m
To
43.8912 m
Intercept Depth
42.3672 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-52S:42.3672-43.8912
Mining Method
underground

Location

Location
360 Portal
Azimuth
229.1 °
Dip
-72.7 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept confirms strong tungsten mineralization in the newly discovered 360 portal vein, adding to the project's exploration potential.

Positive factors

  • Strong tungsten grade (0.475% WO3)
  • True width estimated at 1.03m
  • Part of new vein discovery (360 portal vein)

Evidence · table

“0.475”

Context: 5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 65-70% for AT26-52S, providing better context for the intercept.

Evidence · text

“True width is estimated at 65-70% for AT26-47S, 52S and 55S.”

Step-Out ExtensionRejected · positive

Mineralization extended beyond the previously known limit.

Reason: This hole is part of the initial surface exploration holes that intercepted the newly identified 360 portal vein.

Evidence · text

“Drilling results from initial surface exploration holes completed in the base of the canyon successfully intercepted a newly identified vein – the 360 portal vein.”
AT26-53IMA Mine · tungstenGrade: 0.238Grade Unit: %Intercept: 1.524 mView all details
Link to this fact

Identity

Hole ID
AT26-53
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.238
Grade Unit
%
Intercept
1.524 m
True Width
0.95 m
From
28.3464 m
To
29.8704 m
Intercept Depth
28.3464 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-53:28.3464-29.8704
Mining Method
underground

Location

Location
D Level
Azimuth
95.3 °
Dip
43.9 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept provides moderate-grade tungsten mineralization, contributing to the expansion and delineation of the upper-Ima vein system on the D Level.

Positive factors

  • Moderate tungsten grade (0.238% WO3)
  • True width estimated at 0.95m
  • Expands and delineates the upper-Ima vein system

Evidence · table

“0.238”

Context: 5

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-53 was designed to expand and step out from previous drilling, part of the infill program.

Evidence · text

“Drillholes AT26-49 and AT26-53 were upwardly inclined holes drilled to the north and west respectively from underground drill-stations DS3 and DS1 and were designed to expand and step out from previous drilling.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 60-65% for AT26-53, providing better context for the intercept.

Evidence · text

“True width is estimated at 60-65% for AT26-37, 49 and 53.”
AT26-53IMA Mine · tungstenGrade: 1.513Grade Unit: %Intercept: 1.524 mView all details
Link to this fact

Identity

Hole ID
AT26-53
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
1.513
Grade Unit
%
Intercept
1.524 m
True Width
0.95 m
From
55.776 m
To
57.3 m
Intercept Depth
55.776 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-53:55.776-57.3
Mining Method
underground

Location

Location
D Level
Azimuth
95.3 °
Dip
43.9 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept shows an exceptional tungsten grade, significantly contributing to the expansion and delineation of the upper-Ima vein system on the D Level.

Positive factors

  • Exceptional tungsten grade (1.513% WO3)
  • True width estimated at 0.95m
  • Expands and delineates the upper-Ima vein system

Evidence · table

“1.513”

Context: 5

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-53 was designed to expand and step out from previous drilling, part of the infill program.

Evidence · text

“Drillholes AT26-49 and AT26-53 were upwardly inclined holes drilled to the north and west respectively from underground drill-stations DS3 and DS1 and were designed to expand and step out from previous drilling.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The grade of 1.513% WO3 is exceptionally high for tungsten mineralization.

Evidence · table

“1.513”

Context: 5

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 60-65% for AT26-53, providing better context for the intercept.

Evidence · text

“True width is estimated at 60-65% for AT26-37, 49 and 53.”
AT26-53IMA Mine · tungstenGrade: 0.179Grade Unit: %Intercept: 1.524 mView all details
Link to this fact

Identity

Hole ID
AT26-53
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.179
Grade Unit
%
Intercept
1.524 m
True Width
0.95 m
From
75.5904 m
To
77.1144 m
Intercept Depth
75.5904 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-53:75.5904-77.1144
Mining Method
underground

Location

Location
D Level
Azimuth
95.3 °
Dip
43.9 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept provides low-grade tungsten mineralization, contributing to the overall understanding of the vein system.

Positive factors

  • Low tungsten grade (0.179% WO3)
  • True width estimated at 0.95m
  • Contributes to understanding of vein system

Evidence · table

“0.179”

Context: 5

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-53 was designed to expand and step out from previous drilling, part of the infill program.

Evidence · text

“Drillholes AT26-49 and AT26-53 were upwardly inclined holes drilled to the north and west respectively from underground drill-stations DS3 and DS1 and were designed to expand and step out from previous drilling.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 60-65% for AT26-53, providing better context for the intercept.

Evidence · text

“True width is estimated at 60-65% for AT26-37, 49 and 53.”
AT26-53IMA Mine · tungstenGrade: 0.121Grade Unit: %Intercept: 1.524 mView all details
Link to this fact

Identity

Hole ID
AT26-53
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.121
Grade Unit
%
Intercept
1.524 m
True Width
0.95 m
From
83.2104 m
To
84.7344 m
Intercept Depth
83.2104 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-53:83.2104-84.7344
Mining Method
underground

Location

Location
D Level
Azimuth
95.3 °
Dip
43.9 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept provides low-grade tungsten mineralization, contributing to the overall understanding of the vein system.

Positive factors

  • Low tungsten grade (0.121% WO3)
  • True width estimated at 0.95m
  • Contributes to understanding of vein system

Evidence · table

“0.121”

Context: 5

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Hole AT26-53 was designed to expand and step out from previous drilling, part of the infill program.

Evidence · text

“Drillholes AT26-49 and AT26-53 were upwardly inclined holes drilled to the north and west respectively from underground drill-stations DS3 and DS1 and were designed to expand and step out from previous drilling.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 60-65% for AT26-53, providing better context for the intercept.

Evidence · text

“True width is estimated at 60-65% for AT26-37, 49 and 53.”
AT26-55SIMA Mine · tungstenGrade: 0.131Grade Unit: %Intercept: 1.0668 mView all details
Link to this fact

Identity

Hole ID
AT26-55S
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.131
Grade Unit
%
Intercept
1.0668 m
True Width
0.72 m
From
62.1792 m
To
63.246 m
Intercept Depth
62.1792 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-55S:62.1792-63.246
Mining Method
underground

Location

Location
360 Portal
Azimuth
240 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept confirms tungsten mineralization in the newly discovered 360 portal vein, adding to the project's exploration potential.

Positive factors

  • Moderate tungsten grade (0.131% WO3)
  • True width estimated at 0.72m
  • Part of new vein discovery (360 portal vein)

Evidence · table

“0.131”

Context: 3.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 65-70% for AT26-55S, providing better context for the intercept.

Evidence · text

“True width is estimated at 65-70% for AT26-47S, 52S and 55S.”

Step-Out ExtensionRejected · positive

Mineralization extended beyond the previously known limit.

Reason: This hole is part of the initial surface exploration holes that intercepted the newly identified 360 portal vein.

Evidence · text

“Drilling results from initial surface exploration holes completed in the base of the canyon successfully intercepted a newly identified vein – the 360 portal vein.”
AT26-58SIMA Mine · tungstenGrade: 0.536Grade Unit: %Intercept: 5.76072 mView all details
Link to this fact

Identity

Hole ID
AT26-58S
Project
IMA Mine
Commodity
tungsten
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.536
Grade Unit
%
Intercept
5.76072 m
True Width
4.75 m
From
46.17744 m
To
51.87696 m
Intercept Depth
46.17744 m

Classification

Program
mixed
Sample Type
drill
Group ID
AT26-58S:46.17744-51.87696
Mining Method
underground

Location

Location
360 Portal
Azimuth
278.2 °
Dip
-52.7 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
% WO3

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: This intercept confirms strong tungsten mineralization over a significant width in the newly discovered 360 portal vein, adding substantial exploration potential.

Positive factors

  • Strong tungsten grade (0.536% WO3) over a significant width
  • True width estimated at 4.75m
  • Part of new vein discovery (360 portal vein)

Evidence · table

“0.536”

Context: 18.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

True Width DisclosedRejected · positive

Actual thickness perpendicular to structure is stated, not just downhole length.

Reason: True width is estimated at 75-90% for AT26-58S, providing better context for the intercept.

Evidence · text

“True width is estimated at 75-90% for AT26-58S and 46.”

Step-Out ExtensionRejected · positive

Mineralization extended beyond the previously known limit.

Reason: This hole is part of the initial surface exploration holes that intercepted the newly identified 360 portal vein.

Evidence · text

“Drilling results from initial surface exploration holes completed in the base of the canyon successfully intercepted a newly identified vein – the 360 portal vein.”
AT26-37IMA Mine · copperGrade: 0.175Grade Unit: %Intercept: 454 mView all details
Link to this fact

Identity

Hole ID
AT26-37
Project
IMA Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.175
Grade Unit
%
Intercept
454 m
From
100 m
To
101 m
Intercept Depth
100 m

Classification

Sample Type
drill
Group ID
AT26-37:100-101
Mining Method
underground

Location

Azimuth
350 °
Dip
30 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.175 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 79.4 %·m is moderate (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.175”

Context: AT26-37

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-37IMA Mine · leadGrade: 0.43Grade Unit: %Intercept: 454 mView all details
Link to this fact

Identity

Hole ID
AT26-37
Project
IMA Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.43
Grade Unit
%
Intercept
454 m
From
100 m
To
101 m
Intercept Depth
100 m

Classification

Sample Type
drill
Group ID
AT26-37:100-101
Mining Method
underground

Location

Azimuth
350 °
Dip
30 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.43 % lead is strong against the default band [10, 6, 3, 1] %. Grade×width 195.2 %·m is strong (grade alone is below; the better of the two is used).

Positive factors

  • 0.43 % lead is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.43”

Context: AT26-37

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-37IMA Mine · zincGrade: 0.47Grade Unit: %Intercept: 454 mView all details
Link to this fact

Identity

Hole ID
AT26-37
Project
IMA Mine
Commodity
zinc
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.47
Grade Unit
%
Intercept
454 m
From
100 m
To
101 m
Intercept Depth
100 m

Classification

Sample Type
drill
Group ID
AT26-37:100-101
Mining Method
underground

Location

Azimuth
350 °
Dip
30 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.47 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 213.4 %·m is strong (grade alone is below; the better of the two is used).

Positive factors

  • 0.47 % zinc is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.47”

Context: AT26-37

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-46IMA Mine · copperGrade: 0.027Grade Unit: %Intercept: 449 mView all details
Link to this fact

Identity

Hole ID
AT26-46
Project
IMA Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.027
Grade Unit
%
Intercept
449 m
From
29 m
To
33.5 m
Intercept Depth
29 m

Classification

Sample Type
drill
Group ID
AT26-46:29-33.5
Mining Method
underground

Location

Azimuth
64.7 °
Dip
-63.1 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.027 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 12.1 %·m is below.

Negative factors

  • 0.027 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.027”

Context: AT26-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-46IMA Mine · leadGrade: 0.02Grade Unit: %Intercept: 449 mView all details
Link to this fact

Identity

Hole ID
AT26-46
Project
IMA Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.02
Grade Unit
%
Intercept
449 m
From
29 m
To
33.5 m
Intercept Depth
29 m

Classification

Sample Type
drill
Group ID
AT26-46:29-33.5
Mining Method
underground

Location

Azimuth
64.7 °
Dip
-63.1 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 9.0 %·m is below.

Negative factors

  • 0.02 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: AT26-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-46IMA Mine · zincGrade: 0.02Grade Unit: %Intercept: 449 mView all details
Link to this fact

Identity

Hole ID
AT26-46
Project
IMA Mine
Commodity
zinc
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.02
Grade Unit
%
Intercept
449 m
From
29 m
To
33.5 m
Intercept Depth
29 m

Classification

Sample Type
drill
Group ID
AT26-46:29-33.5
Mining Method
underground

Location

Azimuth
64.7 °
Dip
-63.1 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 9.0 %·m is below.

Negative factors

  • 0.02 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: AT26-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-47SIMA Mine · copperGrade: 0.112Grade Unit: %Intercept: 360 mView all details
Link to this fact

Identity

Hole ID
AT26-47S
Project
IMA Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.112
Grade Unit
%
Intercept
360 m
From
184 m
To
199 m
Intercept Depth
184 m

Classification

Sample Type
drill
Group ID
AT26-47S:184-199
Mining Method
underground

Location

Azimuth
300 °
Dip
-45 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.112 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 40.3 %·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.112”

Context: AT26-47S

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-47SIMA Mine · leadGrade: 0.09Grade Unit: %Intercept: 360 mView all details
Link to this fact

Identity

Hole ID
AT26-47S
Project
IMA Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.09
Grade Unit
%
Intercept
360 m
From
184 m
To
199 m
Intercept Depth
184 m

Classification

Sample Type
drill
Group ID
AT26-47S:184-199
Mining Method
underground

Location

Azimuth
300 °
Dip
-45 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % lead is moderate against the default band [10, 6, 3, 1] %. Grade×width 32.4 %·m is moderate (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.09”

Context: AT26-47S

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-47SIMA Mine · zincGrade: 0.21Grade Unit: %Intercept: 360 mView all details
Link to this fact

Identity

Hole ID
AT26-47S
Project
IMA Mine
Commodity
zinc
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.21
Grade Unit
%
Intercept
360 m
From
184 m
To
199 m
Intercept Depth
184 m

Classification

Sample Type
drill
Group ID
AT26-47S:184-199
Mining Method
underground

Location

Azimuth
300 °
Dip
-45 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.21 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 75.6 %·m is moderate (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.21”

Context: AT26-47S

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-49IMA Mine · copperGrade: 0.555Grade Unit: %Intercept: 411 mView all details
Link to this fact

Identity

Hole ID
AT26-49
Project
IMA Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.555
Grade Unit
%
Intercept
411 m
From
17.7 m
To
23 m
Intercept Depth
17.7 m

Classification

Sample Type
drill
Group ID
AT26-49:17.7-23
Mining Method
underground

Location

Azimuth
2.6 °
Dip
59 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.555 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 228.1 %·m is strong (grade alone is moderate; the better of the two is used).

Positive factors

  • 0.555 % copper is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.555”

Context: AT26-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-49IMA Mine · leadGrade: 0.47Grade Unit: %Intercept: 411 mView all details
Link to this fact

Identity

Hole ID
AT26-49
Project
IMA Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.47
Grade Unit
%
Intercept
411 m
From
17.7 m
To
23 m
Intercept Depth
17.7 m

Classification

Sample Type
drill
Group ID
AT26-49:17.7-23
Mining Method
underground

Location

Azimuth
2.6 °
Dip
59 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.47 % lead is strong against the default band [10, 6, 3, 1] %. Grade×width 193.2 %·m is strong (grade alone is below; the better of the two is used).

Positive factors

  • 0.47 % lead is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.47”

Context: AT26-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-49IMA Mine · zincGrade: 0.22Grade Unit: %Intercept: 411 mView all details
Link to this fact

Identity

Hole ID
AT26-49
Project
IMA Mine
Commodity
zinc
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.22
Grade Unit
%
Intercept
411 m
From
17.7 m
To
23 m
Intercept Depth
17.7 m

Classification

Sample Type
drill
Group ID
AT26-49:17.7-23
Mining Method
underground

Location

Azimuth
2.6 °
Dip
59 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.22 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 90.4 %·m is moderate (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.22”

Context: AT26-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-52SIMA Mine · copperGrade: 0.078Grade Unit: %Intercept: 512.5 mView all details
Link to this fact

Identity

Hole ID
AT26-52S
Project
IMA Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.078
Grade Unit
%
Intercept
512.5 m
From
139 m
To
144 m
Intercept Depth
139 m

Classification

Sample Type
drill
Group ID
AT26-52S:139-144
Mining Method
underground

Location

Azimuth
229.1 °
Dip
-72.7 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.078 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 40.0 %·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.078”

Context: AT26-52S

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-52SIMA Mine · leadGrade: 0.24Grade Unit: %Intercept: 512.5 mView all details
Link to this fact

Identity

Hole ID
AT26-52S
Project
IMA Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.24
Grade Unit
%
Intercept
512.5 m
From
139 m
To
144 m
Intercept Depth
139 m

Classification

Sample Type
drill
Group ID
AT26-52S:139-144
Mining Method
underground

Location

Azimuth
229.1 °
Dip
-72.7 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.24 % lead is strong against the default band [10, 6, 3, 1] %. Grade×width 123.0 %·m is strong (grade alone is below; the better of the two is used).

Positive factors

  • 0.24 % lead is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.24”

Context: AT26-52S

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-52SIMA Mine · zincGrade: 0.19Grade Unit: %Intercept: 512.5 mView all details
Link to this fact

Identity

Hole ID
AT26-52S
Project
IMA Mine
Commodity
zinc
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.19
Grade Unit
%
Intercept
512.5 m
From
139 m
To
144 m
Intercept Depth
139 m

Classification

Sample Type
drill
Group ID
AT26-52S:139-144
Mining Method
underground

Location

Azimuth
229.1 °
Dip
-72.7 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.19 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 97.4 %·m is moderate (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.19”

Context: AT26-52S

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-53IMA Mine · copperGrade: 0.033Grade Unit: %Intercept: 463 mView all details
Link to this fact

Identity

Hole ID
AT26-53
Project
IMA Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.033
Grade Unit
%
Intercept
463 m
From
93 m
To
98 m
Intercept Depth
93 m

Classification

Sample Type
drill
Group ID
AT26-53:93-98
Mining Method
underground

Location

Azimuth
95.3 °
Dip
43.9 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.033 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 15.3 %·m is below.

Negative factors

  • 0.033 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.033”

Context: AT26-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-53IMA Mine · leadGrade: 0.01Grade Unit: %Intercept: 463 mView all details
Link to this fact

Identity

Hole ID
AT26-53
Project
IMA Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.01
Grade Unit
%
Intercept
463 m
From
93 m
To
98 m
Intercept Depth
93 m

Classification

Sample Type
drill
Group ID
AT26-53:93-98
Mining Method
underground

Location

Azimuth
95.3 °
Dip
43.9 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 4.6 %·m is below.

Negative factors

  • 0.01 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: AT26-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-53IMA Mine · zincGrade: 0.05Grade Unit: %Intercept: 463 mView all details
Link to this fact

Identity

Hole ID
AT26-53
Project
IMA Mine
Commodity
zinc
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.05
Grade Unit
%
Intercept
463 m
From
93 m
To
98 m
Intercept Depth
93 m

Classification

Sample Type
drill
Group ID
AT26-53:93-98
Mining Method
underground

Location

Azimuth
95.3 °
Dip
43.9 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 23.2 %·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.05”

Context: AT26-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-55SIMA Mine · copperGrade: 0.072Grade Unit: %Intercept: 368 mView all details
Link to this fact

Identity

Hole ID
AT26-55S
Project
IMA Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.072
Grade Unit
%
Intercept
368 m
From
204 m
To
207.5 m
Intercept Depth
204 m

Classification

Sample Type
drill
Group ID
AT26-55S:204-207.5
Mining Method
underground

Location

Azimuth
240 °
Dip
-45 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.072 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 26.5 %·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.072”

Context: AT26-55S

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-55SIMA Mine · leadGrade: 0.03Grade Unit: %Intercept: 368 mView all details
Link to this fact

Identity

Hole ID
AT26-55S
Project
IMA Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.03
Grade Unit
%
Intercept
368 m
From
204 m
To
207.5 m
Intercept Depth
204 m

Classification

Sample Type
drill
Group ID
AT26-55S:204-207.5
Mining Method
underground

Location

Azimuth
240 °
Dip
-45 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 11.0 %·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: AT26-55S

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-55SIMA Mine · zincGrade: 0.08Grade Unit: %Intercept: 368 mView all details
Link to this fact

Identity

Hole ID
AT26-55S
Project
IMA Mine
Commodity
zinc
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.08
Grade Unit
%
Intercept
368 m
From
204 m
To
207.5 m
Intercept Depth
204 m

Classification

Sample Type
drill
Group ID
AT26-55S:204-207.5
Mining Method
underground

Location

Azimuth
240 °
Dip
-45 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 29.4 %·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.08”

Context: AT26-55S

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-58SIMA Mine · copperGrade: 0.093Grade Unit: %Intercept: 599.5 mView all details
Link to this fact

Identity

Hole ID
AT26-58S
Project
IMA Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.093
Grade Unit
%
Intercept
599.5 m
From
151.3 m
To
170.2 m
Intercept Depth
151.3 m

Classification

Sample Type
drill
Group ID
AT26-58S:151.3-170.2
Mining Method
underground

Location

Azimuth
278.2 °
Dip
-52.7 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.093 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 55.8 %·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.093”

Context: AT26-58S

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-58SIMA Mine · leadGrade: 0.15Grade Unit: %Intercept: 599.5 mView all details
Link to this fact

Identity

Hole ID
AT26-58S
Project
IMA Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.15
Grade Unit
%
Intercept
599.5 m
From
151.3 m
To
170.2 m
Intercept Depth
151.3 m

Classification

Sample Type
drill
Group ID
AT26-58S:151.3-170.2
Mining Method
underground

Location

Azimuth
278.2 °
Dip
-52.7 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % lead is strong against the default band [10, 6, 3, 1] %. Grade×width 89.9 %·m is strong (grade alone is below; the better of the two is used).

Positive factors

  • 0.15 % lead is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.15”

Context: AT26-58S

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

AT26-58SIMA Mine · zincGrade: 0.38Grade Unit: %Intercept: 599.5 mView all details
Link to this fact

Identity

Hole ID
AT26-58S
Project
IMA Mine
Commodity
zinc
Region
usa_id
Reported Region
usa_id
Ticker
TUNG.V

Geometry

Grade
0.38
Grade Unit
%
Intercept
599.5 m
From
151.3 m
To
170.2 m
Intercept Depth
151.3 m

Classification

Sample Type
drill
Group ID
AT26-58S:151.3-170.2
Mining Method
underground

Location

Azimuth
278.2 °
Dip
-52.7 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.38 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 227.8 %·m is strong (grade alone is below; the better of the two is used).

Positive factors

  • 0.38 % zinc is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.38”

Context: AT26-58S

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.