NorthWest Copper Corp. announced additional drilling results from its 100% owned Kwanika project in British Columbia, highlighting significant copper and gold intercepts in the North Pit Extension Zone. The 2026 drill program successfully extended higher-grade mineralization 50 metres north and confirmed additional mineralized intervals, indicating potential for open-pit resource expansion. The results include 61.9 metres of 0.37% Cu and 0.58 g/t Au (1.01% CuEq) from 39 metres.
Reasoning: New drill results from the 2026 program at Kwanika's North Pit Extension Zone successfully extended higher-grade mineralization 50 metres north and confirmed additional mineralized intervals, indicating potential for open-pit resource expansion. Several intercepts show exceptional copper equivalent grades, and true widths are estimated. The program also included infill drilling to improve geological understanding, and comprehensive QA/QC procedures were disclosed.
Positive factors
- Step-Out Extension
- True Width Disclosed
- QA/QC Disclosed
- Bonanza Intercepts
- Infill Drilling
Negative factors
- Cut-off Undisclosed
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 82

Classification and evidence
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: The document provides 'True Width Est. (m)' for all reported intercepts in Table 1.
Evidence · table
“True Width Est. (m)”
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: The release states that results 'extend interpreted higher-grade mineralization approximately 50 metres north' and 'extend mineralization beyond the areas defined by previous drilling'.
Evidence · text
“The results extend interpreted higher-grade mineralization approximately 50 metres north, confirm additional mineralized intervals near surface and at depth, and highlight opportunities for potential expansion of the open-pit mineral resource within the North Pit Extension.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The document includes a 'Quality Assurance / Quality Control' section detailing sample collection, external QA/QC program with blanks and standards, laboratory accreditation (ISO 17025), and re-assaying at a secondary laboratory.
Evidence · text
“Quality Assurance / Quality Control Drilling at Kwanika in 2026 was designed and supervised by NorthWest and implemented by InData Geoscience with assay QA/QC checks by Explore Geosolutions. Samples were collected, tracked and an external QA/QC program was implemented using coarse blanks and certified prepared blanks and standards to monitor analytical accuracy and precision. The samples were sealed on site and shipped to Activation Laboratories Ltd. (“Actlabs”) in Kamloops, BC. The laboratory’s internal quality control system complies with global certifications for quality ISO 17025. Drill core samples were analyzed using a combination of Actlabs multi-element 1F2 analysis for low level concentrations (4-Acid Digestion, ICP-OES) and the 8-4 Acid ICP-OES analysis for higher level concentrations (4-Acid Digestion, ICP-OES with automatic over limits for base metals and silver). Gold, platinum and palladium assaying was completed with 1C-OES method, using a 30-gram fire assay with ICP finish analysis. In addition, about 5% of the sample pulps are re-assayed at a secondary laboratory to confirm reproducibility and check for bias.”
QP/CP Signedpositive · Story-specific tag
Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.
Why it applies: The technical and scientific aspects of the news release have been reviewed, verified, and approved by Geoff Chinn, P.Geo., VP Business Development and Exploration for NorthWest, who is a qualified person as defined by National Instrument 43-101.
Evidence · text
“Technical and scientific aspects of this news release have been reviewed, verified, and approved by Geoff Chinn, P.Geo., VP Business Development and Exploration for NorthWest, who is a qualified person as defined by National Instrument 43-101 – Standards of Disclosure for Mineral Projects.”
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: The release mentions 'Infilled and extended multiple intervals' and 'reducing drill hole spacing to approximately 50 metres' which indicates infill drilling.
Evidence · text
“Infilled and extended multiple intervals of sub-parallel near-surface mineralization”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: The document does not explicitly state the cut-off grade used for compositing the reported drill intervals.
Evidence · text
“61.9 metres of 0.37% Cu and 0.58 g/t Au (1.01% CuEq) from 39.0 metres, including 34.5 metres of 0.49% Cu and 0.88 g/t Au (1.46% CuEq) from 42.0 metres.”
Extracted facts
Stored fact records: 82. Some facts used in scoring do not have a stored record.
Drill Results (82)
K-26-296Kwanika · copperGrade: 0.37Grade Unit: %Intercept: 61.9 mView all detailsHide details
Identity
- Hole ID
- K-26-296
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.37
- Grade Unit
- %
- Intercept
- 61.9 m
- True Width
- 54.7 m
- From
- 39 m
- To
- 100.9 m
- Hole Depth
- 141 m
- Intercept Depth
- 39 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-296:39-100.9
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351589
- Northing
- 6156455
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1012 m
- Azimuth
- 265 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.01
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Exceptional copper equivalent grade over a significant width, with true width estimated, extending mineralization in the North Pit Extension Zone. Supported by disclosed QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.37”
Context: 61.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 54.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-296Kwanika · copperGrade: 0.49Grade Unit: %Intercept: 34.5 mView all detailsHide details
Identity
- Hole ID
- K-26-296
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.49
- Grade Unit
- %
- Intercept
- 34.5 m
- True Width
- 30.5 m
- From
- 42 m
- To
- 76.5 m
- Hole Depth
- 141 m
- Intercept Depth
- 39 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-296:42-76.5
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351589
- Northing
- 6156455
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1012 m
- Azimuth
- 265 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.46
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Exceptional copper equivalent grade over a significant width, with true width estimated, as a sub-interval of a larger intercept. Supported by disclosed QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.49”
Context: 34.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 30.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-296Kwanika · copperGrade: 0.34Grade Unit: %Intercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- K-26-296
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.34
- Grade Unit
- %
- Intercept
- 5.5 m
- True Width
- 4.9 m
- From
- 135.5 m
- To
- 141 m
- Hole Depth
- 141 m
- Intercept Depth
- 39 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-296:135.5-141
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351589
- Northing
- 6156455
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1012 m
- Azimuth
- 265 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.6
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Moderate copper equivalent grade over a narrow width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.34”
Context: 5.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-302Kwanika · copperGrade: 0.46Grade Unit: %Intercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.46
- Grade Unit
- %
- Intercept
- 10.3 m
- True Width
- 9.3 m
- From
- 92 m
- To
- 102.3 m
- Hole Depth
- 231 m
- Intercept Depth
- 92 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-302:92-102.3
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351651
- Northing
- 6156453
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1014 m
- Azimuth
- 270 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.77
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Strong copper equivalent grade over a moderate width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.46”
Context: 10.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 9.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-302Kwanika · copperGrade: 0.21Grade Unit: %Intercept: 8.8 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.21
- Grade Unit
- %
- Intercept
- 8.8 m
- True Width
- 7.9 m
- From
- 133.8 m
- To
- 142.5 m
- Hole Depth
- 231 m
- Intercept Depth
- 92 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-302:133.8-142.5
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351651
- Northing
- 6156453
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1014 m
- Azimuth
- 270 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.92
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Exceptional copper equivalent grade over a moderate width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.21”
Context: 8.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-302Kwanika · copperGrade: 0.11Grade Unit: %Intercept: 30.3 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.11
- Grade Unit
- %
- Intercept
- 30.3 m
- True Width
- 27.5 m
- From
- 152.1 m
- To
- 182.4 m
- Hole Depth
- 231 m
- Intercept Depth
- 92 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-302:152.1-182.4
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351651
- Northing
- 6156453
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1014 m
- Azimuth
- 270 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.64
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Moderate copper equivalent grade over a strong width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.11”
Context: 30.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 27.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-302Kwanika · copperGrade: 0.21Grade Unit: %Intercept: 8.3 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.21
- Grade Unit
- %
- Intercept
- 8.3 m
- True Width
- 7.5 m
- From
- 190.4 m
- To
- 198.7 m
- Hole Depth
- 231 m
- Intercept Depth
- 92 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-302:190.4-198.7
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351651
- Northing
- 6156453
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1014 m
- Azimuth
- 270 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.69
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Moderate copper equivalent grade over a moderate width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.21”
Context: 8.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-302Kwanika · copperGrade: 0.29Grade Unit: %Intercept: 20 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.29
- Grade Unit
- %
- Intercept
- 20 m
- True Width
- 18.1 m
- From
- 211 m
- To
- 231 m
- Hole Depth
- 231 m
- Intercept Depth
- 92 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-302:211-231
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351651
- Northing
- 6156453
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1014 m
- Azimuth
- 270 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.57
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Exceptional copper equivalent grade over a strong width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.29”
Context: 20.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 18.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-305Kwanika · copperGrade: 0.7Grade Unit: %Intercept: 4 mView all detailsHide details
Identity
- Hole ID
- K-26-305
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.7
- Grade Unit
- %
- Intercept
- 4 m
- True Width
- 3.5 m
- From
- 43 m
- To
- 47 m
- Hole Depth
- 176 m
- Intercept Depth
- 43 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-305:43-47
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351501
- Northing
- 6156460
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1011 m
- Azimuth
- 270 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.33
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Exceptional copper equivalent grade over a narrow width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.70”
Context: 4.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-305Kwanika · copperGrade: 0.63Grade Unit: %Intercept: 14 mView all detailsHide details
Identity
- Hole ID
- K-26-305
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.63
- Grade Unit
- %
- Intercept
- 14 m
- True Width
- 12.1 m
- From
- 102 m
- To
- 116 m
- Hole Depth
- 176 m
- Intercept Depth
- 43 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-305:102-116
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351501
- Northing
- 6156460
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1011 m
- Azimuth
- 270 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.81
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Exceptional copper equivalent grade over a moderate width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.63”
Context: 14.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 12.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-337Kwanika · copperGrade: 0.3Grade Unit: %Intercept: 36 mView all detailsHide details
Identity
- Hole ID
- K-26-337
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 36 m
- True Width
- 32.6 m
- From
- 184 m
- To
- 220 m
- Hole Depth
- 261 m
- Intercept Depth
- 184 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-337:184-220
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351708
- Northing
- 6156451
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1013 m
- Azimuth
- 270 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.56
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Moderate copper equivalent grade over a strong width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.30”
Context: 36.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 32.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-337Kwanika · copperGrade: 0.35Grade Unit: %Intercept: 8.3 mView all detailsHide details
Identity
- Hole ID
- K-26-337
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.35
- Grade Unit
- %
- Intercept
- 8.3 m
- True Width
- 7.5 m
- From
- 210 m
- To
- 218.3 m
- Hole Depth
- 261 m
- Intercept Depth
- 184 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-337:210-218.3
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351708
- Northing
- 6156451
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1013 m
- Azimuth
- 270 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.69
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Moderate copper equivalent grade over a moderate width, with true width estimated, as a sub-interval. Supported by disclosed QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.35”
Context: 8.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-343Kwanika · copperGrade: 0.31Grade Unit: %Intercept: 102 mView all detailsHide details
Identity
- Hole ID
- K-26-343
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.31
- Grade Unit
- %
- Intercept
- 102 m
- True Width
- 83.5 m
- From
- 209 m
- To
- 311 m
- Hole Depth
- 324 m
- Intercept Depth
- 209 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-343:209-311
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351708
- Northing
- 6156451
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1012 m
- Azimuth
- 270 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.6
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Moderate copper equivalent grade over a continuous width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.31”
Context: 102.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 83.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-343Kwanika · copperGrade: 0.62Grade Unit: %Intercept: 5.9 mView all detailsHide details
Identity
- Hole ID
- K-26-343
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.62
- Grade Unit
- %
- Intercept
- 5.9 m
- True Width
- 4.8 m
- From
- 222.1 m
- To
- 228 m
- Hole Depth
- 324 m
- Intercept Depth
- 209 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-343:222.1-228
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351708
- Northing
- 6156451
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1012 m
- Azimuth
- 270 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.22
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Exceptional copper equivalent grade over a narrow width, with true width estimated, as a sub-interval. Supported by disclosed QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.62”
Context: 5.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-343Kwanika · copperGrade: 0.37Grade Unit: %Intercept: 20.5 mView all detailsHide details
Identity
- Hole ID
- K-26-343
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.37
- Grade Unit
- %
- Intercept
- 20.5 m
- True Width
- 16.8 m
- From
- 274.5 m
- To
- 295 m
- Hole Depth
- 324 m
- Intercept Depth
- 209 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-343:274.5-295
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351708
- Northing
- 6156451
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1012 m
- Azimuth
- 270 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.76
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Strong copper equivalent grade over a strong width, with true width estimated, as a sub-interval. Supported by disclosed QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.37”
Context: 20.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 16.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-343Kwanika · copperGrade: 0.3Grade Unit: %Intercept: 7.5 mView all detailsHide details
Identity
- Hole ID
- K-26-343
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 7.5 m
- True Width
- 6.1 m
- From
- 303.5 m
- To
- 311 m
- Hole Depth
- 324 m
- Intercept Depth
- 209 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-343:303.5-311
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351708
- Northing
- 6156451
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1012 m
- Azimuth
- 270 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.86
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Exceptional copper equivalent grade over a moderate width, with true width estimated, as a sub-interval. Supported by disclosed QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.30”
Context: 7.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-347Kwanika · copperGrade: 0.1Grade Unit: %Intercept: 4.1 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 4.1 m
- True Width
- 3.4 m
- From
- 78 m
- To
- 82.1 m
- Hole Depth
- 165 m
- Intercept Depth
- 78 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-347:78-82.1
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351536
- Northing
- 6156462
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1012 m
- Azimuth
- 265 °
- Dip
- -58 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.68
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Moderate copper equivalent grade over a narrow width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.10”
Context: 4.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-347Kwanika · copperGrade: 0.33Grade Unit: %Intercept: 6 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.33
- Grade Unit
- %
- Intercept
- 6 m
- True Width
- 5 m
- From
- 99 m
- To
- 105 m
- Hole Depth
- 165 m
- Intercept Depth
- 78 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-347:99-105
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351536
- Northing
- 6156462
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1012 m
- Azimuth
- 265 °
- Dip
- -58 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.48
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Moderate copper equivalent grade over a moderate width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.33”
Context: 6.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-347Kwanika · copperGrade: 0.27Grade Unit: %Intercept: 5 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.27
- Grade Unit
- %
- Intercept
- 5 m
- True Width
- 4.2 m
- From
- 111 m
- To
- 116 m
- Hole Depth
- 165 m
- Intercept Depth
- 78 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-347:111-116
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351536
- Northing
- 6156462
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1012 m
- Azimuth
- 265 °
- Dip
- -58 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.45
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Moderate copper equivalent grade over a narrow width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.27”
Context: 5.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-347Kwanika · copperGrade: 0.33Grade Unit: %Intercept: 12 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.33
- Grade Unit
- %
- Intercept
- 12 m
- True Width
- 10.1 m
- From
- 152 m
- To
- 164 m
- Hole Depth
- 165 m
- Intercept Depth
- 78 m
Classification
- Deposit Type
- porphyry
- Program
- mixed
- Sample Type
- drill
- Group ID
- K-26-347:152-164
- Mining Method
- open_pit
Location
- Location
- Pit N. Ext.
- Easting
- 351536
- Northing
- 6156462
- CRS
- UTM Zone 10N NAD83
- Elevation
- 1012 m
- Azimuth
- 265 °
- Dip
- -58 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.56
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Moderate copper equivalent grade over a moderate width, with true width estimated. Supported by disclosed QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.33”
Context: 12.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 10.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
K-26-296Kwanika · goldGrade: 0.58Grade Unit: g/tIntercept: 61.9 mView all detailsHide details
Identity
- Hole ID
- K-26-296
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.58
- Grade Unit
- g/t
- Intercept
- 61.9 m
- True Width
- 54.7 m
- From
- 39 m
- To
- 100.9 m
- Hole Depth
- 141 m
- Intercept Depth
- 39 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-296:39-100.9
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.01
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.58 g/t gold is strong against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 35.9 g/t·m is moderate (grade alone is strong; the better of the two is used).
Positive factors
- 0.58 g/t gold is strong on the porphyry deposit band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.58”
Context: K-26-296
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 54.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-296Kwanika · silverGrade: 1.55Grade Unit: g/tIntercept: 61.9 mView all detailsHide details
Identity
- Hole ID
- K-26-296
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 1.55
- Grade Unit
- g/t
- Intercept
- 61.9 m
- True Width
- 54.7 m
- From
- 39 m
- To
- 100.9 m
- Hole Depth
- 141 m
- Intercept Depth
- 39 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-296:39-100.9
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.01
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.55 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 95.9 g/t·m is below.
Negative factors
- 1.55 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.55”
Context: K-26-296
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 54.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-296Kwanika · palladiumGrade: 0.03Grade Unit: g/tIntercept: 61.9 mView all detailsHide details
Identity
- Hole ID
- K-26-296
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.03
- Grade Unit
- g/t
- Intercept
- 61.9 m
- True Width
- 54.7 m
- From
- 39 m
- To
- 100.9 m
- Hole Depth
- 141 m
- Intercept Depth
- 39 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-296:39-100.9
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.01
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.03 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.03”
Context: K-26-296
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 54.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-296Kwanika · goldGrade: 0.88Grade Unit: g/tIntercept: 34.5 mView all detailsHide details
Identity
- Hole ID
- K-26-296
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.88
- Grade Unit
- g/t
- Intercept
- 34.5 m
- True Width
- 30.5 m
- From
- 42 m
- To
- 76.5 m
- Hole Depth
- 141 m
- Intercept Depth
- 42 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-296:42-76.5
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.46
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.88 g/t gold is strong against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 30.4 g/t·m is moderate (grade alone is strong; the better of the two is used).
Positive factors
- 0.88 g/t gold is strong on the porphyry deposit band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.88”
Context: Including
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 30.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-296Kwanika · silverGrade: 1.85Grade Unit: g/tIntercept: 34.5 mView all detailsHide details
Identity
- Hole ID
- K-26-296
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 1.85
- Grade Unit
- g/t
- Intercept
- 34.5 m
- True Width
- 30.5 m
- From
- 42 m
- To
- 76.5 m
- Hole Depth
- 141 m
- Intercept Depth
- 42 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-296:42-76.5
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.46
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.85 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 63.8 g/t·m is below.
Negative factors
- 1.85 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.85”
Context: Including
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 30.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-296Kwanika · palladiumGrade: 0.04Grade Unit: g/tIntercept: 34.5 mView all detailsHide details
Identity
- Hole ID
- K-26-296
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.04
- Grade Unit
- g/t
- Intercept
- 34.5 m
- True Width
- 30.5 m
- From
- 42 m
- To
- 76.5 m
- Hole Depth
- 141 m
- Intercept Depth
- 42 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-296:42-76.5
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.46
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.04 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.04”
Context: Including
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 30.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-296Kwanika · goldGrade: 0.23Grade Unit: g/tIntercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- K-26-296
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 5.5 m
- True Width
- 4.9 m
- From
- 135.5 m
- To
- 141 m
- Hole Depth
- 141 m
- Intercept Depth
- 135.5 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-296:135.5-141
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.6
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.23 g/t gold is weak against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 1.3 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.23”
Context: K-26-296
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-296Kwanika · silverGrade: 1.56Grade Unit: g/tIntercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- K-26-296
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 1.56
- Grade Unit
- g/t
- Intercept
- 5.5 m
- True Width
- 4.9 m
- From
- 135.5 m
- To
- 141 m
- Hole Depth
- 141 m
- Intercept Depth
- 135.5 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-296:135.5-141
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.6
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.56 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.6 g/t·m is below.
Negative factors
- 1.56 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.56”
Context: K-26-296
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-296Kwanika · palladiumGrade: 0Grade Unit: g/tIntercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- K-26-296
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 5.5 m
- True Width
- 4.9 m
- From
- 135.5 m
- To
- 141 m
- Hole Depth
- 141 m
- Intercept Depth
- 135.5 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-296:135.5-141
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.6
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.00”
Context: K-26-296
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · goldGrade: 0.27Grade Unit: g/tIntercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 10.3 m
- True Width
- 9.3 m
- From
- 92 m
- To
- 102.3 m
- Hole Depth
- 231 m
- Intercept Depth
- 92 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:92-102.3
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.77
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.27 g/t gold is weak against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 2.8 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.27”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 9.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · silverGrade: 1.61Grade Unit: g/tIntercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 1.61
- Grade Unit
- g/t
- Intercept
- 10.3 m
- True Width
- 9.3 m
- From
- 92 m
- To
- 102.3 m
- Hole Depth
- 231 m
- Intercept Depth
- 92 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:92-102.3
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.77
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.61 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 16.6 g/t·m is below.
Negative factors
- 1.61 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.61”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 9.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · palladiumGrade: 0Grade Unit: g/tIntercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 10.3 m
- True Width
- 9.3 m
- From
- 92 m
- To
- 102.3 m
- Hole Depth
- 231 m
- Intercept Depth
- 92 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:92-102.3
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.77
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.00”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 9.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · goldGrade: 0.65Grade Unit: g/tIntercept: 8.8 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.65
- Grade Unit
- g/t
- Intercept
- 8.8 m
- True Width
- 7.9 m
- From
- 133.8 m
- To
- 142.5 m
- Hole Depth
- 231 m
- Intercept Depth
- 133.8 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:133.8-142.5
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.92
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.65 g/t gold is strong against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 5.7 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 0.65 g/t gold is strong on the porphyry deposit band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.65”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · silverGrade: 0.86Grade Unit: g/tIntercept: 8.8 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.86
- Grade Unit
- g/t
- Intercept
- 8.8 m
- True Width
- 7.9 m
- From
- 133.8 m
- To
- 142.5 m
- Hole Depth
- 231 m
- Intercept Depth
- 133.8 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:133.8-142.5
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.92
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.86 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.6 g/t·m is below.
Negative factors
- 0.86 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.86”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · palladiumGrade: 0.02Grade Unit: g/tIntercept: 8.8 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 8.8 m
- True Width
- 7.9 m
- From
- 133.8 m
- To
- 142.5 m
- Hole Depth
- 231 m
- Intercept Depth
- 133.8 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:133.8-142.5
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.92
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.02 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.02”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · goldGrade: 0.49Grade Unit: g/tIntercept: 30.3 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.49
- Grade Unit
- g/t
- Intercept
- 30.3 m
- True Width
- 27.5 m
- From
- 152.1 m
- To
- 182.4 m
- Hole Depth
- 231 m
- Intercept Depth
- 152.1 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:152.1-182.4
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.64
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.49 g/t gold is moderate against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 14.8 g/t·m is weak (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.49”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 27.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · silverGrade: 0.49Grade Unit: g/tIntercept: 30.3 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.49
- Grade Unit
- g/t
- Intercept
- 30.3 m
- True Width
- 27.5 m
- From
- 152.1 m
- To
- 182.4 m
- Hole Depth
- 231 m
- Intercept Depth
- 152.1 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:152.1-182.4
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.64
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.49 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 14.8 g/t·m is below.
Negative factors
- 0.49 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.49”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 27.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · palladiumGrade: 0.02Grade Unit: g/tIntercept: 30.3 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 30.3 m
- True Width
- 27.5 m
- From
- 152.1 m
- To
- 182.4 m
- Hole Depth
- 231 m
- Intercept Depth
- 152.1 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:152.1-182.4
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.64
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.02 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.02”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 27.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · goldGrade: 0.45Grade Unit: g/tIntercept: 8.3 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.45
- Grade Unit
- g/t
- Intercept
- 8.3 m
- True Width
- 7.5 m
- From
- 190.4 m
- To
- 198.7 m
- Hole Depth
- 231 m
- Intercept Depth
- 190.4 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:190.4-198.7
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.69
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.45 g/t gold is moderate against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 3.7 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.45”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · silverGrade: 0.76Grade Unit: g/tIntercept: 8.3 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.76
- Grade Unit
- g/t
- Intercept
- 8.3 m
- True Width
- 7.5 m
- From
- 190.4 m
- To
- 198.7 m
- Hole Depth
- 231 m
- Intercept Depth
- 190.4 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:190.4-198.7
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.69
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.76 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.3 g/t·m is below.
Negative factors
- 0.76 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.76”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · palladiumGrade: 0.06Grade Unit: g/tIntercept: 8.3 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.06
- Grade Unit
- g/t
- Intercept
- 8.3 m
- True Width
- 7.5 m
- From
- 190.4 m
- To
- 198.7 m
- Hole Depth
- 231 m
- Intercept Depth
- 190.4 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:190.4-198.7
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.69
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.06 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.06”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · goldGrade: 1.18Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 1.18
- Grade Unit
- g/t
- Intercept
- 20 m
- True Width
- 18.1 m
- From
- 211 m
- To
- 231 m
- Hole Depth
- 231 m
- Intercept Depth
- 211 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:211-231
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.57
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.18 g/t gold is exceptional against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 23.6 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 1.18 g/t gold is exceptional on the porphyry deposit band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.18”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 18.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · silverGrade: 1.15Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 1.15
- Grade Unit
- g/t
- Intercept
- 20 m
- True Width
- 18.1 m
- From
- 211 m
- To
- 231 m
- Hole Depth
- 231 m
- Intercept Depth
- 211 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:211-231
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.57
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.15 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 23.0 g/t·m is below.
Negative factors
- 1.15 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.15”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 18.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-302Kwanika · palladiumGrade: 0.02Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- K-26-302
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 20 m
- True Width
- 18.1 m
- From
- 211 m
- To
- 231 m
- Hole Depth
- 231 m
- Intercept Depth
- 211 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-302:211-231
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.57
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.02 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.02”
Context: K-26-302
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 18.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-305Kwanika · goldGrade: 0.57Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- K-26-305
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.57
- Grade Unit
- g/t
- Intercept
- 4 m
- True Width
- 3.5 m
- From
- 43 m
- To
- 47 m
- Hole Depth
- 176 m
- Intercept Depth
- 43 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-305:43-47
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.33
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.57 g/t gold is strong against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 2.3 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 0.57 g/t gold is strong on the porphyry deposit band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.57”
Context: K-26-305
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-305Kwanika · silverGrade: 1.5Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- K-26-305
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 1.5
- Grade Unit
- g/t
- Intercept
- 4 m
- True Width
- 3.5 m
- From
- 43 m
- To
- 47 m
- Hole Depth
- 176 m
- Intercept Depth
- 43 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-305:43-47
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.33
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.0 g/t·m is below.
Negative factors
- 1.5 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.50”
Context: K-26-305
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-305Kwanika · palladiumGrade: 0.01Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- K-26-305
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 4 m
- True Width
- 3.5 m
- From
- 43 m
- To
- 47 m
- Hole Depth
- 176 m
- Intercept Depth
- 43 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-305:43-47
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.33
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.01 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.01”
Context: K-26-305
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-305Kwanika · goldGrade: 0.15Grade Unit: g/tIntercept: 14 mView all detailsHide details
Identity
- Hole ID
- K-26-305
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 14 m
- True Width
- 12.1 m
- From
- 102 m
- To
- 116 m
- Hole Depth
- 176 m
- Intercept Depth
- 102 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-305:102-116
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.81
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.15 g/t gold is weak against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 2.1 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.15”
Context: K-26-305
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 12.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-305Kwanika · silverGrade: 0.81Grade Unit: g/tIntercept: 14 mView all detailsHide details
Identity
- Hole ID
- K-26-305
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.81
- Grade Unit
- g/t
- Intercept
- 14 m
- True Width
- 12.1 m
- From
- 102 m
- To
- 116 m
- Hole Depth
- 176 m
- Intercept Depth
- 102 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-305:102-116
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.81
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.81 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.3 g/t·m is below.
Negative factors
- 0.81 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.81”
Context: K-26-305
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 12.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-305Kwanika · palladiumGrade: 0.01Grade Unit: g/tIntercept: 14 mView all detailsHide details
Identity
- Hole ID
- K-26-305
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 14 m
- True Width
- 12.1 m
- From
- 102 m
- To
- 116 m
- Hole Depth
- 176 m
- Intercept Depth
- 102 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-305:102-116
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.81
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.01 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.01”
Context: K-26-305
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 12.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-337Kwanika · goldGrade: 0.24Grade Unit: g/tIntercept: 36 mView all detailsHide details
Identity
- Hole ID
- K-26-337
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.24
- Grade Unit
- g/t
- Intercept
- 36 m
- True Width
- 32.6 m
- From
- 184 m
- To
- 220 m
- Hole Depth
- 261 m
- Intercept Depth
- 184 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-337:184-220
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.56
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.24 g/t gold is weak against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 8.6 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.24”
Context: K-26-337
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 32.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-337Kwanika · silverGrade: 0.31Grade Unit: g/tIntercept: 36 mView all detailsHide details
Identity
- Hole ID
- K-26-337
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.31
- Grade Unit
- g/t
- Intercept
- 36 m
- True Width
- 32.6 m
- From
- 184 m
- To
- 220 m
- Hole Depth
- 261 m
- Intercept Depth
- 184 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-337:184-220
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.56
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.31 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.2 g/t·m is below.
Negative factors
- 0.31 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.31”
Context: K-26-337
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 32.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-337Kwanika · palladiumGrade: 0.01Grade Unit: g/tIntercept: 36 mView all detailsHide details
Identity
- Hole ID
- K-26-337
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 36 m
- True Width
- 32.6 m
- From
- 184 m
- To
- 220 m
- Hole Depth
- 261 m
- Intercept Depth
- 184 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-337:184-220
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.56
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.01 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.01”
Context: K-26-337
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 32.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-337Kwanika · goldGrade: 0.31Grade Unit: g/tIntercept: 8.3 mView all detailsHide details
Identity
- Hole ID
- K-26-337
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.31
- Grade Unit
- g/t
- Intercept
- 8.3 m
- True Width
- 7.5 m
- From
- 210 m
- To
- 218.3 m
- Hole Depth
- 261 m
- Intercept Depth
- 210 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-337:210-218.3
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.69
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.31 g/t gold is moderate against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 2.6 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.31”
Context: Including
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-337Kwanika · silverGrade: 0.3Grade Unit: g/tIntercept: 8.3 mView all detailsHide details
Identity
- Hole ID
- K-26-337
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 8.3 m
- True Width
- 7.5 m
- From
- 210 m
- To
- 218.3 m
- Hole Depth
- 261 m
- Intercept Depth
- 210 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-337:210-218.3
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.69
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.5 g/t·m is below.
Negative factors
- 0.3 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.30”
Context: Including
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-337Kwanika · palladiumGrade: 0.01Grade Unit: g/tIntercept: 8.3 mView all detailsHide details
Identity
- Hole ID
- K-26-337
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 8.3 m
- True Width
- 7.5 m
- From
- 210 m
- To
- 218.3 m
- Hole Depth
- 261 m
- Intercept Depth
- 210 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-337:210-218.3
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.69
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.01 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.01”
Context: Including
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-343Kwanika · goldGrade: 0.27Grade Unit: g/tIntercept: 102 mView all detailsHide details
Identity
- Hole ID
- K-26-343
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 102 m
- True Width
- 83.5 m
- From
- 209 m
- To
- 311 m
- Hole Depth
- 324 m
- Intercept Depth
- 209 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-343:209-311
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.6
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.27 g/t gold is weak against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 27.5 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.27”
Context: K-26-343
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 83.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-343Kwanika · silverGrade: 0.29Grade Unit: g/tIntercept: 102 mView all detailsHide details
Identity
- Hole ID
- K-26-343
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.29
- Grade Unit
- g/t
- Intercept
- 102 m
- True Width
- 83.5 m
- From
- 209 m
- To
- 311 m
- Hole Depth
- 324 m
- Intercept Depth
- 209 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-343:209-311
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.6
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.29 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 29.6 g/t·m is below.
Negative factors
- 0.29 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.29”
Context: K-26-343
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 83.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-343Kwanika · palladiumGrade: 0.01Grade Unit: g/tIntercept: 102 mView all detailsHide details
Identity
- Hole ID
- K-26-343
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 102 m
- True Width
- 83.5 m
- From
- 209 m
- To
- 311 m
- Hole Depth
- 324 m
- Intercept Depth
- 209 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-343:209-311
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.6
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.01 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.01”
Context: K-26-343
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 83.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-343Kwanika · goldGrade: 0.56Grade Unit: g/tIntercept: 5.9 mView all detailsHide details
Identity
- Hole ID
- K-26-343
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.56
- Grade Unit
- g/t
- Intercept
- 5.9 m
- True Width
- 4.8 m
- From
- 222.1 m
- To
- 228 m
- Hole Depth
- 324 m
- Intercept Depth
- 222.1 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-343:222.1-228
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.22
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.56 g/t gold is strong against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 3.3 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 0.56 g/t gold is strong on the porphyry deposit band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.56”
Context: Including
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-343Kwanika · silverGrade: 0.33Grade Unit: g/tIntercept: 5.9 mView all detailsHide details
Identity
- Hole ID
- K-26-343
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.33
- Grade Unit
- g/t
- Intercept
- 5.9 m
- True Width
- 4.8 m
- From
- 222.1 m
- To
- 228 m
- Hole Depth
- 324 m
- Intercept Depth
- 222.1 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-343:222.1-228
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.22
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.33 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.9 g/t·m is below.
Negative factors
- 0.33 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.33”
Context: Including
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-343Kwanika · palladiumGrade: 0.01Grade Unit: g/tIntercept: 5.9 mView all detailsHide details
Identity
- Hole ID
- K-26-343
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 5.9 m
- True Width
- 4.8 m
- From
- 222.1 m
- To
- 228 m
- Hole Depth
- 324 m
- Intercept Depth
- 222.1 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-343:222.1-228
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.22
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.01 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.01”
Context: Including
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndKwanika · copperGrade: 0.37Grade Unit: %Intercept: 20.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.37
- Grade Unit
- %
- Intercept
- 20.5 m
- True Width
- 16.8 m
- From
- 274.5 m
- To
- 295 m
- Hole Depth
- 141 m
- Intercept Depth
- 274.5 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- And:274.5-295
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.76
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.37 % copper is moderate against the porphyry deposit band [0.8, 0.4, 0.25, 0.15] %. Grade×width 7.6 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.37”
Context: And
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 16.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndKwanika · goldGrade: 0.36Grade Unit: g/tIntercept: 20.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.36
- Grade Unit
- g/t
- Intercept
- 20.5 m
- True Width
- 16.8 m
- From
- 274.5 m
- To
- 295 m
- Hole Depth
- 141 m
- Intercept Depth
- 274.5 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- And:274.5-295
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.76
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.36 g/t gold is moderate against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 7.4 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.36”
Context: And
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 16.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndKwanika · silverGrade: 0.34Grade Unit: g/tIntercept: 20.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 20.5 m
- True Width
- 16.8 m
- From
- 274.5 m
- To
- 295 m
- Hole Depth
- 141 m
- Intercept Depth
- 274.5 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- And:274.5-295
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.76
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.34 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.0 g/t·m is below.
Negative factors
- 0.34 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.34”
Context: And
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 16.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndKwanika · palladiumGrade: 0.01Grade Unit: g/tIntercept: 20.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 20.5 m
- True Width
- 16.8 m
- From
- 274.5 m
- To
- 295 m
- Hole Depth
- 141 m
- Intercept Depth
- 274.5 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- And:274.5-295
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.76
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.01 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.01”
Context: And
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 16.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndKwanika · copperGrade: 0.3Grade Unit: %Intercept: 7.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Kwanika
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 7.5 m
- True Width
- 6.1 m
- From
- 303.5 m
- To
- 311 m
- Hole Depth
- 141 m
- Intercept Depth
- 303.5 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- And:303.5-311
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.86
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.3 % copper is moderate against the porphyry deposit band [0.8, 0.4, 0.25, 0.15] %. Grade×width 2.3 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.30”
Context: And
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndKwanika · goldGrade: 0.52Grade Unit: g/tIntercept: 7.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.52
- Grade Unit
- g/t
- Intercept
- 7.5 m
- True Width
- 6.1 m
- From
- 303.5 m
- To
- 311 m
- Hole Depth
- 141 m
- Intercept Depth
- 303.5 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- And:303.5-311
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.86
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.52 g/t gold is strong against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 3.9 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 0.52 g/t gold is strong on the porphyry deposit band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.52”
Context: And
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndKwanika · silverGrade: 0.36Grade Unit: g/tIntercept: 7.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.36
- Grade Unit
- g/t
- Intercept
- 7.5 m
- True Width
- 6.1 m
- From
- 303.5 m
- To
- 311 m
- Hole Depth
- 141 m
- Intercept Depth
- 303.5 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- And:303.5-311
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.86
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.36 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.7 g/t·m is below.
Negative factors
- 0.36 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.36”
Context: And
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndKwanika · palladiumGrade: 0.03Grade Unit: g/tIntercept: 7.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.03
- Grade Unit
- g/t
- Intercept
- 7.5 m
- True Width
- 6.1 m
- From
- 303.5 m
- To
- 311 m
- Hole Depth
- 141 m
- Intercept Depth
- 303.5 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- And:303.5-311
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.86
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.03 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.03”
Context: And
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-347Kwanika · goldGrade: 0.54Grade Unit: g/tIntercept: 4.1 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.54
- Grade Unit
- g/t
- Intercept
- 4.1 m
- True Width
- 3.4 m
- From
- 78 m
- To
- 82.1 m
- Hole Depth
- 165 m
- Intercept Depth
- 78 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-347:78-82.1
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.68
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.54 g/t gold is strong against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 2.2 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 0.54 g/t gold is strong on the porphyry deposit band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.54”
Context: K-26-347
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-347Kwanika · silverGrade: 0.49Grade Unit: g/tIntercept: 4.1 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.49
- Grade Unit
- g/t
- Intercept
- 4.1 m
- True Width
- 3.4 m
- From
- 78 m
- To
- 82.1 m
- Hole Depth
- 165 m
- Intercept Depth
- 78 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-347:78-82.1
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.68
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.49 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.0 g/t·m is below.
Negative factors
- 0.49 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.49”
Context: K-26-347
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-347Kwanika · palladiumGrade: 0Grade Unit: g/tIntercept: 4.1 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 4.1 m
- True Width
- 3.4 m
- From
- 78 m
- To
- 82.1 m
- Hole Depth
- 165 m
- Intercept Depth
- 78 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-347:78-82.1
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.68
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.00”
Context: K-26-347
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-347Kwanika · goldGrade: 0.13Grade Unit: g/tIntercept: 6 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.13
- Grade Unit
- g/t
- Intercept
- 6 m
- True Width
- 5 m
- From
- 99 m
- To
- 105 m
- Hole Depth
- 165 m
- Intercept Depth
- 99 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-347:99-105
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.48
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.13 g/t gold is below against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 0.8 g/t·m is below.
Negative factors
- 0.13 g/t gold is below the weak threshold (0.15 g/t) on the porphyry deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.13”
Context: K-26-347
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-347Kwanika · silverGrade: 1.32Grade Unit: g/tIntercept: 6 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 1.32
- Grade Unit
- g/t
- Intercept
- 6 m
- True Width
- 5 m
- From
- 99 m
- To
- 105 m
- Hole Depth
- 165 m
- Intercept Depth
- 99 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-347:99-105
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.48
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.32 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.9 g/t·m is below.
Negative factors
- 1.32 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.32”
Context: K-26-347
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-347Kwanika · palladiumGrade: 0Grade Unit: g/tIntercept: 6 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 6 m
- True Width
- 5 m
- From
- 99 m
- To
- 105 m
- Hole Depth
- 165 m
- Intercept Depth
- 99 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-347:99-105
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.48
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.00”
Context: K-26-347
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-347Kwanika · goldGrade: 0.16Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.16
- Grade Unit
- g/t
- Intercept
- 5 m
- True Width
- 4.2 m
- From
- 111 m
- To
- 116 m
- Hole Depth
- 165 m
- Intercept Depth
- 111 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-347:111-116
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.45
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.16 g/t gold is weak against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 0.8 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.16”
Context: K-26-347
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-347Kwanika · silverGrade: 1.45Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 1.45
- Grade Unit
- g/t
- Intercept
- 5 m
- True Width
- 4.2 m
- From
- 111 m
- To
- 116 m
- Hole Depth
- 165 m
- Intercept Depth
- 111 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-347:111-116
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.45
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.45 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.3 g/t·m is below.
Negative factors
- 1.45 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.45”
Context: K-26-347
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-347Kwanika · palladiumGrade: 0.01Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 5 m
- True Width
- 4.2 m
- From
- 111 m
- To
- 116 m
- Hole Depth
- 165 m
- Intercept Depth
- 111 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-347:111-116
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.45
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.01 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.01”
Context: K-26-347
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-347Kwanika · goldGrade: 0.2Grade Unit: g/tIntercept: 12 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 12 m
- True Width
- 10.1 m
- From
- 152 m
- To
- 164 m
- Hole Depth
- 165 m
- Intercept Depth
- 152 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-347:152-164
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.56
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.2 g/t gold is weak against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 2.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.20”
Context: K-26-347
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 10.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-347Kwanika · silverGrade: 1.71Grade Unit: g/tIntercept: 12 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 1.71
- Grade Unit
- g/t
- Intercept
- 12 m
- True Width
- 10.1 m
- From
- 152 m
- To
- 164 m
- Hole Depth
- 165 m
- Intercept Depth
- 152 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-347:152-164
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.56
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.71 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 20.5 g/t·m is below.
Negative factors
- 1.71 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.71”
Context: K-26-347
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 10.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
K-26-347Kwanika · palladiumGrade: 0.01Grade Unit: g/tIntercept: 12 mView all detailsHide details
Identity
- Hole ID
- K-26-347
- Project
- Kwanika
- Commodity
- palladium
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- NWST
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 12 m
- True Width
- 10.1 m
- From
- 152 m
- To
- 164 m
- Hole Depth
- 165 m
- Intercept Depth
- 152 m
Classification
- Deposit Type
- porphyry
- Sample Type
- drill
- Group ID
- K-26-347:152-164
- Mining Method
- open_pit
Location
- CRS
- UTM Zone 10N NAD83
QA/QC
- Laboratory
- Activation Laboratories Ltd. ("Actlabs")
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.56
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-11-11T00:00:00.000Z
Reasoning: Expanded from assay table: 0.01 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.01”
Context: K-26-347
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 10.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.